Output data formatter for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Output Data Formatter (ODF) for the ESTAR (Electronically Scanned Thinned Array Radiometer) instrument has been designed and tested. It employs programmable logic devices to format and tag correlator data for transmission to Earth. After accepting 170 bits or correlator and error data in parallel, it appends an identification word and then serially passes the data to the Small Explorer Data System (SEDS) for transmission at a maximum rate of greater than 15 Mb/sec. Implemented with two reprogrammable field programmable gate arrays (FPGA's), each contained in a 132-pin plastic pin grid array (PGA) package, the design is cascadeable, fully testable, and low-power.

Chren, William A., Jr.↗

COBE Differential Microwave Radiometer (DMR) data processing techniques

The purpose of the Differential Microwave Radiometer (DMR) experiment on the Cosmic Background Explorer (COBE) satellite is to make whole-sky maps, at frequencies of 31.5, 53, and 90 GHz, of any departures of the Cosmic Microwave Background (CMB) from its mean value of 2.735 K. An elaborate software system is necessary to calibrate and invert the differential measurements, so as to make sky maps free from large scale systematic errors to levels less than a millionth of the CMB.

Jackson, P. D.↗

Daily quality assurance software for a satellite radiometer system

Six Differential Microwave Radiometers (DMR) on COBE (Cosmic Background Explorer) measure the large-angular-scale isotropy of the cosmic microwave background (CMB) at 31.5, 53, and 90 GHz. Quality assurance software analyzes the daily telemetry from the spacecraft to ensure that the instrument is operating correctly and that the data are not corrupted. Quality assurance for DMR poses challenging requirements. The data are differential, so a single bad point can affect a large region of the sky, yet the CMB isotropy requires lengthy integration times (greater than 1 year) to limit potential CMB anisotropies. Celestial sources (with the exception of the moon) are not, in general, visible in the raw differential data. A 'quicklook' software system was developed that, in addition to basic plotting and limit-checking, implements a collection of data tests as well as long-term trending. Some of the key capabilities include the following: (1) stability analysis showing how well the data RMS averages down with increased data; (2) a Fourier analysis and autocorrelation routine to plot the power spectrum and confirm the presence of the 3 mK 'cosmic' dipole signal; (3) binning of the data against basic spacecraft quantities such as orbit angle; (4) long-term trending; and (5) dipole fits to confirm the spacecraft attitude azimuth angle.

Keegstra, P. B.↗

Walsh function generator for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Walsh Function Generator (WFG) for the ESTAR (Electronically Scanned Thinned Array Radiometer) instrument has been designed and tested. Implemented in a single Xilinx XC3020PC68-50 Field Programmable Gate Array (FPGA), it generates a user-programmable set of 32 consecutive Walsh Functions for noise cancellation in the analog circuitry of the Front-End Modules (FEM's). It is implemented in a 68-pin plastic leaded chip carrier (PLCC) package, is fully testable, and can be used for noise cancellation periods as small as 2 msec.

Chren, William A., Jr.↗

Absolute calibration of an ultraviolet spectrometer using a stabilized laser and a cryogenic cavity radiometer

We carry out the calibration of an ultraviolet spectrometer by using a cryogenic electrical-substitution radiometer and intensity-stabilized laser sources. A comparison of the error budgets for the laser-based calibration described here and for a calibration using a type-FEL tungsten spectral-irradiance standard indicates that this technique could provide an improvement of a factor of about three in the uncertainty of the spectrometer calibration, resulting in an absolute accuracy (standard deviation of three) of about 1 percent at 257 nm. The technique described here might significantly improve the accuracy of calibrations on NASA ozone-monitoring and solar ultraviolet-monitoring spectrophotometers when used to complement present procedures that employ lamps and the SURF II synchrotron ultraviolet radiation facility at the National Institute of Standards and Technology.

Jauniskis, L.↗

Measurement of oceanic wind vector using satellite microwave radiometers

A feasibility study of deriving both a wind speed and direction from microwave radiometer measurements of the ocean is presented. The study was based on the Special Sensor Microwave/Imager (SSM/I) measurements in conjunction with buoy reports from the National Data Buoy Center. It was found that the SSM/I minus the buoy wind speed difference is correlated with wind direction due to a wind direction signal in the brightness temperatures. When this wind direction signal is removed the rms difference between the SSM/I and buoy winds reduces to 1.3 m/s. The wind direction signal was used to make global, low-resolution maps of the monthly mean oceanic wind vector.

Wentz, Frank J.↗

COBE Differential Microwave Radiometers - Preliminary systematic error analysis

The techniques available for the identification and subtraction of sources of dynamic uncertainty from data of the Differential Microwave Radiometer (DMR) instrument aboard COBE are discussed. Preliminary limits on the magnitude in the DMR 1 yr maps are presented. Residual uncertainties in the best DMR sky maps, after correcting the raw data for systematic effects, are less than 6 micro-K for the pixel rms variation, less than 3 micro-K for the rms quadruple amplitude of a spherical harmonic expansion, and less than 30 micro-(K-squared) for the correlation function.

Kogut, A.↗

Cryogenic radiometers and intensity-stabilized lasers for Eos radiometric calibrations

Liquid helium-cooled electrical substitution radiometers (ESRs) provide irradiance standards with demonstrated absolute accuracy at the 0.01 percent level, spectrally flat response between the UV and IR, and sensitivity down to 0.1 nW/sq cm. We describe an automated system developed for NASA - Goddard Space Flight Center, consisting of a cryogenic ESR illuminated by servocontrolled laser beams. This system is designed to provide calibration of single-element and array detectors over the spectral range between 257nm in the UV to 10.6 microns in the IR. We also describe a cryogenic ESR optimized for black body calibrations that has been installed at NIST, and another that is under construction for calibrations of the CERES scanners planned for Eos.

Foukal, P.↗

Solar-diffuser panel and ratioing radiometer approach to satellite sensor on-board calibration

The use of a solar-diffuser panel is a desirable approach to the on-board absolute radiometric calibration of satellite multispectral sensors used for earth observation in the solar reflective spectral range. It provides a full aperture, full field, end-to-end calibration near the top of the sensor's dynamic range and across its entire spectral response range. A serious drawback is that the panel's reflectance, and the response of any simple detector used to monitor its reflectance may change with time. This paper briefly reviews some preflight and on-board methods for absolute calibration and introduces the ratioing-radiometer concept in which the radiance of the panel is ratioed with respect to the solar irradiance at the time the multispectral sensor is viewing the panel in its calibration mode.

Slater, Philip N.↗

Differential correction technique for removing common errors in gas filter radiometer measurements

The Measurement of Air Pollution from Satellites (MAPS) gas filter radiometer experiment was designed to measure CO mixing ratios in the earth's atmosphere. MAPS also measures N2O to provide a reference channel for the atmospheric emitting temperature and to detect the presence of clouds. In this paper we formulate equations to correct the radiometric signals based on the spatial and temporal uniformity of the N2O mixing ratio in the atmosphere. Results of an error study demonstrate that these equations reduce the error in inferred CO mixing ratios. Subsequent application of the technique to the MAPS 1984 data set decreases the error in the frequency distribution of mixing ratios and increases the number of usable data points.

Wallio, H. A.↗

Measurement of tropospheric carbon monoxide using gas filter radiometers

The measurement of tropospheric carbon monoxide with gas filter radiometers is examined on the basis of the MAPS experiment. The performance characteristics of an instrument that uses the MAPS detectors, broadband filters, and gas cells in a system similar to the GASCOFIL system described by Morrow and Nicholls (1985) is determined. The signal function for two carbon monoxide channels of the MAPS instrument as it was flown in 1981 is shown. The measurements of the lower pressure channel are weighted to a higher altitude. The signal function, when integrated over altitude and multiplied by the normalization constant, yields the value of the signal. Both signal functions approach zero at the top because the gas concentration approaches zero. The present data reduction technique assumes that there are no clouds in the field of view. If clouds are present, the inferred carbon monoxide mixing ratio is too high, and those points must be rejected from the data set.

Reichle, Henry G., Jr.↗

Transfer function considerations for the CERES scanning radiometer

The Clouds and Earth's Radiant Energy System (CERES) scanning radiometer will determine the radiation budget of the Earth on a regional basis over a number of years. The error in the reconstructed field is used as a design criterion for selecting design parameters for the instrument. The reconstruction error is comprised of errors due to aliasing, blurring and radiance equivalent noise of the instrument, and can be evaluated in terms of the transfer function of the system.

Manalo, N.↗

Calibration of a synthetic aperture radiometer

Calibration algorithms for a synthetic aperture microwave radiometer are presented. The calibration is geared to Earth remote sensing applications, and is demonstrated on an airborne prototype of thinned array imager. Two approaches to the system calibration are presented; the first utilizes commonly available reference brightness temperature scenes, such as open water, and the second utilizes data collected on the antenna range. Both algorithms yield spatial response information which is cast in matrix form and inverted to obtain the image reconstruction formula. Experimental results are examined, and errors in some reconstructed images are linked to the present prototype antenna design. Algorithms for improving the synthesized antenna pattern side lobe performance are also presented. In one solution, the pattern efficiency is optimized by minimizing the pattern outside a defined beam. In another solution, the patterns are matched to a desired model pattern by the method of least squared errors. Both techniques offer an attractive alternative to aperture weighting.

Tanner, Alan B.↗

The Pressure Modulator Infrared Radiometer (PMIRR) optical system alignment and performance

The alignment and performance of the optical system for the Pressure Modulator Infrared Radiometer (PMIRR) are described. This limb and nadir scanning instrument will be used for remote sounding of the Martian atmosphere and will be launched on Mars Observer in 1992. The instrument has nine channels distributed over the wavelength range 0.3 to 50 microns and has two pressure modulator cells for water vapor and carbon dioxide.

Chrisp, Michael P.↗

Atmospheric moisture measurements - A microwave radiometer-radiosonde comparison

Measurements of the thermal emission of the sky at three frequencies (20.7, 22.2, and 31.4 GHz) with the NASA/Goddard Space Flight Center Crustal Dynamics Project MW Water Vapor Radiometer are reported. These measurements are compared with brightness temperatures inferred from measurements from VAISALA radiosonde packages launched every 3 hr during the experiment period. An error analysis for the radiosonde-inferred brightness temperatures is performed under the assumption of reasonable random uncertainties for the pressure, temperature, and humidity measurements and propagation of these uncertainties through the analysis algorithm. For the assumed uncertainties, the dominant contribution to the total uncertainty comes from the temperature measurement (66-88 percent), whereas the relative humidity measurement contributes only 2-8 percent, except in the vicinity of the water vapor line, where the contribution is 10-20 percent.

England, Martin N.↗

Reflectance properties of West African savanna trees from ground radiometer measurements. II - Classification of components

A pole-mounted radiometer was used to measure the reflectance properties in the red and near-IR of three Sahelian tree species. These properties are classified depending on their location over the canopy. A geometrical description of the patterns of shadow and sunlight on and beneath a model tree when viewed from above is given, and six components are defined. Tree canopies are found to be dark in the red waveband with respect to the soil, but have little or no effect on the near-IR.

Hanan, N. P.↗

Topex Microwave Radiometer thermal control - Post-system-test modifications and on-orbit performance

The Topex Microwave Radiometer has had an excellent thermal performance since launch. The instrument, however, went through a hardware modification right before launch to correct for a thermal design inadequacy that was uncovered during the spacecraft thermal vacuum test. This paper reports on how the initially obscure problem was tracked down, and how the thermal models were revised, validated, and utilized to investigate the solution options and guide the hardware modification decisions. Details related to test data interpretation, analytical uncertainties, and model-prediction vs. test-data correlation, are documented. Instrument/spacecraft interface issues, where the problem originated and where in general pitfalls abound, are dealt with specifically. Finally, on-orbit thermal performance data are presented, which exhibit good agreement with flight predictions, and lessons learned are discussed.

Lin, Edward I.↗

Soil moisture verification study of the ESTAR microwave radiometer - Walnut Gulch, AZ 1991

The application of an electronically steered thinned array L-band radiometer (ESTAR) for soil moisture mapping is investigated over the arid rangeland Walnut Gulch Watershed. Antecedent rainfall and evaporation for the flights are very different and result in a wide range of soil moisture conditions. The high spatial variability of rainfall events within this region results in moisture conditions with dramatic spatial patterns. Sensor performance is verified using two approaches. Microwave data are used in conjunction with a microwave emission model to predict soil moisture. These predictions are compared to ground observations of soil moisture. A second verification is possible using an extensive data set. Both tests showed that the ESTAR is capable of providing soil moisture with the same level of accuracy as existing systems.

Jackson, T. J.↗