Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear science & technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Extension of SCALE/Sampler’s sensitivity analysis

Nuclear data are a major source of uncertainties in reactor physics calculations. The propagation of nuclear data uncertainties to important system responses is instrumental when determining appropriate safety margins in reactor safety analyses. It is also important to understand the major contributors to the observed uncertainties to make recommendations for further measurements and evaluations and aid in the understanding of the studied system. The SCALE code system allows for nuclear data uncertainty analysis based on the random sampling approach as implemented in SCALE’s Sampler sequence. Sampler was recently extended by a sensitivity analysis in terms of the calculation of two correlation-based sensitivity indices. This analysis allows for the identification of the top contributing nuclear reactions to any analyzed output uncertainty. This paper presents the sensitivity indices, along with their interpretation and limitations. It demonstrates the application in an eigenvalue and decay heat analysis for a boiling water reactor fuel assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New evaluation on angular distributions and energy spectra for neutron-induced charged-particle measurements

Recent development on neutron-induced charged particle reaction measurements can provide high-quality double differential cross sections at Los Alamos Neutron Science Center. With newly measured cross section data, we found lacking nuclear outputs for neutron-induced charged particle reactions in the latest ENDF/B-VIII.0 library, when compared with Monte Carlo simulations. Here, this paper presents how we improved the missing angular distributions and energy spectra for these reactions and the validation of our new evaluations with the measurements performed with the LENZ instrument at LANSCE. The impact of this additional evaluation is demonstrated by comparing the MCNP simulations with the LENZ experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER-499 Final Design of a TEX Variant: Chlorine to Support NNSA Operations [Slides]

This presentation concludes the final design of TEX with chlorine absorbers is complete. 5 configurations were identified, expected to down select to three experimental configurations. Great comparison to Y-12 and good comparison to INL sensitivities. Fastest configuration touches on the 35 Cl(n,p) cross section (continuing to work with Terrapower for faster configurations). Extensive density studies performed to ensure understanding of the salt in the plates. Reactivity studies performed to assist with experiment. Finally, the fabrication of the chlorine absorbers is ongoing (with LANL), and the experiment is scheduled to be completed this year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the CERBERUS Evaluation for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook

Modeling & Simulation (M&S) tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers continue to improve, we are able to enhance resolution in our calculations. Therefore, the limitations of simulation capability are in the quality of data that is being used, including our ability to quantify the uncertainty and sensitivity of that data. In order to model systems of interest with increasing accuracy, the industry must improve key nuclear data measurements. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles and evaluates experiment data in a handbook that can be used by criticality safety engineers and others to validate computer codes and cross section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. These experiments, along with differential measurements, can help improve the quality of nuclear data. Concerns regarding the accuracy of Cu nuclear data have been published. The large values and trend of C-E for the Zeus intermediate energy benchmark, being one of the primary examples. Furthermore, very few experiments have been designed to be sensitive to Cu (as shown in Figure 1), so an integral, critical experiment is needed to help resolve these differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin Texture Control and Magnetic Gap Engineering in a Ferromagnetic Insulator–Topological Insulator Sandwiched Heterostructure

Quantum materials that combine magnetism with topological order are emerging as key platforms for next-generation spintronics and low-energy electronics. They enable the realization of emergent quantum phenomena, such as the quantum anomalous Hall effect and axion insulator states. The ferromagnetic insulator (FMI)/topological insulator (TI)/FMI sandwich structure of a single-septuple layer (1SL) MnBi 2 Te 4 /four-quintuple layer (4QL) Bi 2 Te 3 /1SL MnBi 2 Te 4 holds great potential to achieve such desirable quantum phenomena at an elevated temperature, owing to its large Dirac point band gap and high Curie temperature. Here, for this work, spin- and angle-resolved photoemission spectroscopy (spin-ARPES) is employed to directly verify that the band gap arises from broken time-reversal symmetry via proximity-driven magnetization. This study demonstrates direct control of the spin state via external magnetic fields and unambiguously confirms the exchange interaction as the gap-opening mechanism. The robust magnetic gap and controllable spin texture make this heterostructure a suitable candidate for spintronic applications and magnetic topological quantum phases.

exchange gap↗

Plutonium workers get a new level of education in the actinide mission

The Associate Laboratory Directorate for Weapons Production (ALDWP) and the National Security Education Center (NSEC) have teamed to develop a new Nuclear Enterprise Science and Technology (NEST) Academic Certificate program offered through the University of New Mexico – Los Alamos (UNM-LA). The pilot program, which virtually kicked off on January 19 even amidst snow closures, received accreditation by the State Higher Education Department (HED) in FY20 and is designed for LANL’s existing fissile material handler technician and technologist employee workforce. It will provide essential science, operations, and business education on all aspects of working in modern nuclear materials handling and processing facilities. The first course for the certificate program is called “Nuclear Facility Fundamentals.” A call for nominations went out to the directorate and a cohort of 15 individuals has been established to start the program.

61 RADIATION PROTECTION AND DOSIMETRY↗

First demonstration of a triton beam using target normal sheath acceleration

Tritiated titanium targets were irradiated by the short-pulse OMEGA EP laser (1.25 kJ, 10 ps) to generate a laser accelerated pulsed beam of tritons by target normal sheath acceleration. Using a Thomson parabola, the beam was found to contain 10 12 tritons per pulse, with a mean energy of 2.2 MeV and an exponential tail reaching up to 10 MeV. In a separate experiment, the triton beam was directed onto a secondary deuterated polyethylene (CD) target to induce deuterium–tritium (D–T) nuclear reactions. Using neutron time-of-flight spectrometers, approximately 10 8 D–T fusion neutrons were observed per laser pulse. Furthermore, this triton beam presents new research opportunities for the study of the 3 H(t, 2n) 4 He reaction and di-neutron transfers to lithium and beryllium that may produce exotic neutron-rich nuclei of interest to basic nuclear science, astrophysics, and inertial confinement fusion technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗