Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Kinematic fixtures to enable multi-material printing and rapid non-destructive inspection during two-photon lithography

Here, two-photon lithography (TPL) is a polymerization based technique that enables additive manufacturing of millimeter scale parts with submicron features. TPL equipment is often based on retrofitted optical microscopes that lack precise registration capabilities. Consequently, slow and error-prone visual alignment to fiducials is necessary if registration to pre-existing features is required. Herein, we have designed, built, and tested precise kinematic fixtures that are repeatable to within ±315 nm (3σ value) and passively register the build surface to TPL equipment with an accuracy of ±1.7 μm. This enables one to sequentially print with multiple materials by building the structures directly on top of the kinematic fixtures. In addition, the same fixtures passively register to an X-ray computed tomography (CT) system to enable non-destructive 3D inspection that is integrated with the fabrication process. These fixtures (i) provide a practical means to handle micro-scale parts during non-destructive imaging, (ii) reduce the set-up time for X-ray CT from more than an hour to less than a few minutes, and (iii) eliminate operator uncertainty from the multi-material printing and imaging process. As such, these fixtures enable new printing and imaging functionalities that are critical for high-quality additive manufacturing of multi-material polymer parts with microscale and submicron features.

42 ENGINEERING↗

Ocular toxicity of AUY922 in pigmented and albino rats

AUY922, a heat shock protein 90 inhibitor is associated with ocular adverse events (AEs). To provide a better understanding of ocular AEs in patients, 4 investigative studies were performed in a step-wise approach to assess retinal structure and function in pigmented (Brown Norway) and albino (Wistar) rats. In rats administered 30 mg/kg of AUY922, the AUC{sub 0–24} {sub h} and C{sub max} are comparable to that in patients at 70 mg/m{sup 2}. AUY922 at ≥ 30 mg/kg was poorly tolerated by rats with morbidity or mortality generally after the third weekly treatment. Electroretinography (ERG) changes were observed at doses ≥ 30 mg/kg. The ERG changes were dose dependent, consistent with an effect on the photoreceptors, and fully reversible. The ERG effects could not be minimized by decreasing the C{sub max} while maintaining AUC. Histopathological changes were seen mainly when rats were administered AUY922 at 100 mg/kg. The 2-hour infusion of AUY922 at 100 mg/kg caused disorganization of the outer segment photoreceptor morphology in male Brown Norway rats; the severity of the disorganization increased with the number of administrations, but was reversible during a 4-week posttreatment period. There was no major difference in ocular response between Brown Norway and Wistar rats. No changes in serum iron levels, and no changes in rhodopsin, PDE6α, β-transducin concentrations, or retinal pigment epithelium-specific protein RPE65 expression were observed after single and multiple infusions of AUY922 at 100 mg/kg compared to vehicle-treated controls. AUY922 retinal toxicity in rats recapitulates and further characterizes that reported in patients and is shown to be reversible, while a precise molecular mechanism for the effect was not determined. - Highlights: • Ocular toxicity of AUY922 was assessed in Brown Norway and Wistar rats. • AUY922 at ≥ 30 mg/kg was generally not well tolerated by rats. • Electroretinography (ERG) changes were observed at doses ≥ 30 mg/kg. • ERG changes at doses ≥ 30 mg/kg were dose-dependent, and fully reversible.

54 ENVIRONMENTAL SCIENCES↗

VELOCITY ANISOTROPY AND SHAPE BIAS IN THE CAUSTIC TECHNIQUE

We use the Millennium Simulation to quantify the statistical accuracy and precision of the escape-velocity technique for measuring cluster-sized halo masses at z {approx} 0.1. We show that in three dimensions one can measure nearly unbiased (<4%) halo masses (>1.5 Multiplication-Sign 10{sup 14} M{sub Sun} h {sup -1}) with 10%-15% scatter. Line-of-sight projection effects increase the scatter to {approx}25%, where we include the known velocity anisotropies. The classical ''caustic'' technique incorporates a calibration factor that is determined from N-body simulations. We derive and test a new implementation that eliminates the need for calibration and utilizes only the observables: the galaxy velocities with respect to the cluster mean v, the projected positions r{sub p} , an estimate of the Navarro-Frenk-White (NFW) density concentration, and an estimate of the velocity anisotropies {beta}. We find that differences between the potential and density NFW concentrations induce a 10% bias in the caustic masses. We also find that large (100%) systematic errors in the observed ensemble average velocity anisotropies and concentrations translate to small (5%-10%) biases in the inferred masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Capturing Infrastructure Interdependencies for Power Outages Prediction During Extreme Events

As extreme weather events such as hurricanes, severe thunderstorms, and floods grow in frequency and intensity, the disruption of power grid systems poses significant challenges, including widespread electrical outages, economic losses, and threats to public safety. This paper presents a forward-looking approach that leverages geographical graph-based machine learning models to predict county-level maximum power outages during such events. By capturing the intricate interdependencies within power system networks, our approach aims to provide precise and actionable predictions that can optimize emergency response efforts and enhance grid resilience. Through the integration of real-world data, including hurricane advisories and power outage records, we have trained and benchmarked multiple machine learning models, demonstrating the feasibility and potential of this method. While our initial results are promising, this paper also charts a course for advancing these models, addressing the remaining challenges, and ultimately transforming how we anticipate and respond to the impacts of extreme weather on power systems.

Lee, Sangkeun (Matt) [ORNL] (ORCID:000000021317511↗

Oxygen isotope characteristics of chondrules from the Yamato-82094 ungrouped carbonaceous chondrite: Further evidence for common O-isotope environments sampled among carbonaceous chondrites

In this study, high-precision secondary ion mass spectrometry (SIMS) was employed to investigate oxygen three isotopes of phenocrysts in 35 chondrules from the Yamato (Y) 82094 ungrouped 3.2 carbonaceous chondrite. Twenty-one of 21 chondrules have multiple homogeneous pyroxene data (Δ 17 O 3SD analytical uncertainty: 0.7‰); 17 of 17 chondrules have multiple homogeneous pyroxene and plagioclase data. Twenty-one of 25 chondrules have one or more olivine data matching coexisting pyroxene data. Such homogeneous phenocrysts (1) are interpreted to have crystallized from the final chondrule melt, defining host O-isotope ratios; and (2) suggest efficient O-isotope exchange between ambient gas and chondrule melt during formation. Host values plot within 0.7‰ of the primitive chondrule mineral (PCM) line. Seventeen chondrules have relict olivine and/or spinel, with some δ 17 O and δ 18 O values approaching -40‰, similar to CAI or AOA-like precursors. Regarding host chondrule data, 22 of 34 have Mg#s of 98.8–99.5 and Δ 17 O of -3.9‰ to -6.1‰, consistent with most Acfer 094, CO, CR, and CV chondrite chondrules, and suggesting a common reduced O-isotope reservoir devoid of 16 O-poor H 2 O. Six Y-82094 chondrules have Δ 17 O near -2.5‰, with Mg#s of 64–97, consistent with lower Mg# chondrules from Acfer 094, CO, CR, and CV chondrites; their signatures suggest precursors consisting of those forming Mg# ~99, Δ 17 O: -5‰ ± 1‰ chondrules plus 16 O-poor H 2 O, at high dust enrichments. Three type II chondrules plot slightly above the PCM line, near the terrestrial fractionation line (Δ 17 O: ~+0.1‰). Their O-isotopes and olivine chemistry are like LL3 type II chondrules, suggesting they sampled ordinary chondrite-like chondrule precursors. Finally, three Mg# >99 chondrules have Δ 17 O of -6.7‰ to -8.1‰, potentially due to 16 O-rich refractory precursor components. Finally, the predominance of Mg# ~99, Δ 17 O: -5‰ ± 1‰ chondrules and a high chondrule-to-matrix ratio suggests bulk Y-82094 characteristics are closely related to anhydrous dust sampled by most carbonaceous chondrite chondrules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Berkeley Efficient Long-Read to Long-Read Aligner and Overlapper (BELLA) v1.0

BELLA is a long-read overlapper and read-to-read aligner that exploits novel approaches for selecting reliable k-mer seeds for filtering and for detecting overlapping read pairs to reconstruct the whole genome. BELLA uses a sparse matrix-matrix multiplication for high-performance overlap detection and then performs pairwise alignment on the overlapping read pairs. BELLA can be built with different pre-existing aligners to use on each read pair, so precision rates are determined by those aligners. Our evaluations include real and synthetic datasets with varying size and complexity and include recall, precision, and running time. BELLA's overlap detection retains nearly all true alignments, with recall rates that exceed other aligners, yet it filters enough read pairs that the running time, including pairwise alignments, is closer to tools that only perform overlapping and is significantly faster than tools that also perform alignment

Guidi, Giulia↗

Single-distance nano-holotomography with coded apertures

High-resolution phase-contrast 3D imaging using nano-holotomography typically requires collecting multiple tomograms at varying sample-to-detector distances, usually 3 to 4. This multi-distance approach limits temporal resolution, making it impractical for operando studies. Moreover, shifting the sample complicates reconstruction, requiring precise alignment, registration, and interpolation to correct for shift-dependent magnification on the detector. In response, we propose and validate through simulations a novel, to the best of our knowledge, single-distance approach that leverages coded apertures to structure beam illumination while the sample rotates. Finally, this approach relies on a joint reconstruction scheme, which integrates phase retrieval with 3D tomography, ensuring data consistency and achieving artifact-free reconstructions from a single distance, unlocking dynamic experiments.

Nikitin, Viktor [Argonne National Laboratory (ANL)↗

Experimental verification of nanometer level optical pathlength control on a flexible structure

This paper describes an experimental facility being developed for demonstration and validation of control concepts arising out of NASA's Control Structure Interaction program. The facility is meant to be a ground testbed with relevance to a broad class of precision optical space systems. The objective of the experimental program is to investigate a multilayer control approach to the maintenance of nanometer-level optical pathlength stability in the presence of external disturbances and multiple structural resonances. The facility is designed to explore the effect of applying, separately and in combinations, structural vibration suppression, vibration isolation, and active optical articulation. This paper describes the testbed facility, the structure, optics, sensors, actuators, and real-time computer and program development environment. Initial optical articulation experimental results are presented.

O'Neal, Michael↗

Two wavelength satellite laser ranging using SPAD

When ranging to satellites with lasers, there are several principal contributions to the error budget: from the laser ranging system on the ground, from the satellite retroarray geometry, and from the atmosphere. Using a single wavelength, we have routinely achieved a ranging precision of 8 millimeters when ranging to the ERS-1 and Starlette satellites. The systematic error of the atmosphere, assuming the existing dispersion models, is expected to be of the order of 1 cm. Multiple wavelengths ranging might contribute to the refinement of the existing models. Taking into account the energy balance, the existing picosecond lasers and the existing receiver and detection technology, several pairs or multiple wavelengths may be considered. To be able to improve the atmospheric models to the subcentimeter accuracy level, the differential time interval (DTI) has to be determined within a few picoseconds depending on the selected wavelength pair. There exist several projects based on picosecond lasers as transmitters and on two types of detection techniques: one is based on photodetectors, like photomultipliers or photodiodes connected to the time interval meters. Another technique is based on the use of a streak camera as an echo signal detector, temporal analyzer, and time interval vernier. The temporal analysis at a single wavelength using the streak camera showed the complexity of the problem.

Prochazka, Ivan↗

A Procedure to Determine the Coordinated Chromium and Calcium Isotopic Composition of Astromaterials Including the Chelyabinsk Meteorite

The isotopic compositions of elements are often used to characterize nucelosynthetic contributions in early Solar System objects. Coordinated multiple middle-mass elements with differing volatilities may provide information regarding the location of condensation of early Solar System solids. Here we detail new procedures that we have developed to make high-precision multi-isotope measurements of chromium and calcium using thermal ionization mass spectrometry, and characterize a suite of chondritic and terrestrial material including two fragments of the Chelyabinsk LL-chondrite.

Tappa, M. J.↗

High-Precision Magellan Orbit Determination for Stereo Image Processin

The purpose of this paper is to describe a technique which improves the precision of Magellan orbit determination by incorporating measurements of landmarks visible in the radar images. The basic techniques was described in the reference, but it has since been refined and significantly extended to handle multiple orbit solutions simultaneously.

Magelllan↗

Highly-scalable, physics-informed GANs for learning solutions of stochastic PDEs

Uncertainty quantification for forward and inverse problems is a central challenge across physical and biomedical disciplines. We address this challenge for the problem of modeling subsurface flow at the Hanford Site by combining stochastic computational models with observational data using physics-informed GAN models. The geographic extent, spatial heterogeneity, and multiple correlation length scales of the Hanford Site require training a computationally intensive GAN model to thousands of dimensions. We develop a highly optimized implementation that scales to {\herogpucount} NVIDIA Volta GPUs. We develop a hierarchical scheme based on a multi-player game-theoretic approach for exploiting domain parallelism, map discriminators and generators to multiple GPUs, and employ efficient communication schemes to ensure training stability and convergence. Our implementation scales to {\heronodecount} nodes on the Summit supercomputer with a \weakscalingeff\% scaling efficiency, achieving peak and sustained half-precision rates of {\heropeakperf} PF/s and {\herosustainedperf} PF/s.

physics informed ML, machine learning, generative ↗

High Accuracy Wavelength Calibration For A Scanning Visible Spectrometer

Spectroscopic applications for plasma velocity measurements often require wavelength accuracies ≤ 0.2Â. An automated calibration for a scanning spectrometer has been developed to achieve a high wavelength accuracy overr the visible spectrum, stable over time and environmental conditions, without the need to recalibrate after each grating movement. The method fits all relevant spectrometer paraameters using multiple calibration spectra. With a steping-motor controlled sine-drive, accuracies of ~0.025 Â have been demonstrated. With the addition of high resolution (0.075 aresec) optical encoder on the grading stage, greater precision (~0.005 Â) is possible, allowing absolute velocity measurements with ~0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structural Changes in Metal Chalcogenide Nanoclusters Associated with Single Heteroatom Incorporation

Atomically precise nanoclusters (NCs) are promising building blocks for designing materials and interfaces with unique properties. By incorporating heteroatoms into the core, the electronic and magnetic properties of NCs can be precisely tuned. To accurately predict these properties, density functional theory (DFT) is often employed, making the rigorous benchmarking of DFT results particularly important. In this study, we present a benchmarking approach based on metal chalcogenide NCs as a model system. We synthesized a series of bimetallic, iron-cobalt chalcogenide NCs [Co 6-x Fe x S 8 (PEt 3 ) 6 ] + (x = 0-6) (PEt = triethyl phosphine) and investigated the effect of heteroatoms in the octahedral metal chalcogenide core on their size and electronic properties. Using ion mobility-mass spectrometry (IM-MS), we observed a gradual increase in the collision cross section (CCS) with an increase in the number of Fe atoms in the core. DFT calculations combined with trajectory method CCS simulations successfully reproduced this trend, revealing that the increase in cluster size is primarily due to changes in metal-ligand bond lengths, while the electronic properties of the core remain largely unchanged. Moreover, this method allowed us to exclude certain multiplicity states of the NCs, as their CCS values were significantly different from those predicted for the lowest-energy structures. Here, this study demonstrates that gas-phase IM-MS is a powerful technique for detecting subtle size differences in atomically precise NCs, which are often challenging to observe using conventional NC characterization methods. Accurate CCS measurements are established as a benchmark for comparison with theoretical calculations. The excellent correspondence between experimental data and theoretical predictions establishes a robust foundation for investigating structural changes of transition metal NCs of interest to a broad range of applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extremely Accurate On-Orbit Position Accuracy using TDRSS

NASA is planning to launch a new service for Earth satellites providing them with precise GPS differential corrections and other ancillary information enabling decimeter level orbit determination accuracy and nanosecond time-transfer accuracy, onboard, in real-time. The TDRSS Augmentation Service for Satellites (TASS) will broadcast its message on the S-band multiple access forward channel of NASA s Tracking and Data Relay Satellite System (TDRSS). The satellite's phase array antenna has been configured to provide a wide beam, extending coverage up to 1000 km altitude over the poles. Global coverage will be ensured with broadcast from three or more TDRSS satellites. The GPS differential corrections are provided by the NASA Global Differential GPS (GDGPS) System, developed and operated by JPL. The GDGPS System employs global ground network of more than 70 GPS receivers to monitor the GPS constellation in real time. The system provides real-time estimates of the GPS satellite states, as well as many other real-time products such as differential corrections, global ionospheric maps, and integrity monitoring. The unique multiply redundant architecture of the GDGPS System ensures very high reliability, with 99.999% demonstrated since the inception of the system in early 2000. The estimated real time GPS orbit and clock states provided by the GDGPS system are accurate to better than 20 cm 3D RMS, and have been demonstrated to support sub-decimeter real time positioning and orbit determination for a variety of terrestrial, airborne, and spaceborne applications. In addition to the GPS differential corrections, TASS will provide real-time Earth orientation and solar flux information that enable precise onboard knowledge of the Earth-fixed position of the spacecraft, and precise orbit prediction and planning capabilities. TASS will also provide 5 seconds alarms for GPS integrity failures based on the unique GPS integrity monitoring service of the GDGPS System.

Stocklin, Frank↗

SU-C-207A-04: Accuracy of Acoustic-Based Proton Range Verification in Water

Purpose: To determine the accuracy and dose required for acoustic-based proton range verification (protoacoustics) in water. Methods: Proton pulses with 17 µs FWHM and instantaneous currents of 480 nA (5.6 × 10{sup 7} protons/pulse, 8.9 cGy/pulse) were generated by a clinical, hospital-based cyclotron at the University of Pennsylvania. The protoacoustic signal generated in a water phantom by the 190 MeV proton pulses was measured with a hydrophone placed at multiple known positions surrounding the dose deposition. The background random noise was measured. The protoacoustic signal was simulated to compare to the experiments. Results: The maximum protoacoustic signal amplitude at 5 cm distance was 5.2 mPa per 1 × 10{sup 7} protons (1.6 cGy at the Bragg peak). The background random noise of the measurement was 27 mPa. Comparison between simulation and experiment indicates that the hydrophone introduced a delay of 2.4 µs. For acoustic data collected with a signal-to-noise ratio (SNR) of 21, deconvolution of the protoacoustic signal with the proton pulse provided the most precise time-of-flight range measurement (standard deviation of 2.0 mm), but a systematic error (−4.5 mm) was observed. Conclusion: Based on water phantom measurements at a clinical hospital-based cyclotron, protoacoustics is a potential technique for measuring the proton Bragg peak range with 2.0 mm standard deviation. Simultaneous use of multiple detectors is expected to reduce the standard deviation, but calibration is required to remove systematic error. Based on the measured background noise and protoacoustic amplitude, a SNR of 5.3 is projected for a deposited dose of 2 Gy.

60 APPLIED LIFE SCIENCES↗

NASA's global differential GPS system and the TDRSS augmentation service for satellites

NASA is planning to launch a new service for Earth satellites providing them with precise GPS differential corrections and other ancillary information enabling decimeter level orbit determination accuracy, and nanosecond time-transfer accuracy, onboard, in real-time. The TDRSS Augmentation Service for Satellites (TASS) will broadcast its message on the S-band multiple access channel of NASA's Tracking and Data Relay Satellite System (TDRSS). The satellite's phase array antenna has been configured to provide a wide beam, extending coverage up to 1000 km altitude over the poles. Global coverage will be ensured with broadcast from three or more TDRSS satellites. The GPS differential corrections are provided by the NASA Global Differential GPS (GDGPS) System, developed and operated by NASA's Jet Propulsion Laboratory. The GDGPS System employs a global ground network of more than 70 GPS receivers to monitor the GPS constellation in real time. The system provides real-time estimates of the GPS satellite states, as well as many other real-time products such as differential corrections, global ionospheric maps, and integrity monitoring. The unique multiply redundant architecture of the GDGPS System ensures very high reliability, with 99.999% demonstrated since the inception of the system in Early 2000. The estimated real time GPS orbit and clock states provided by the GDGPS system are accurate to better than 20 cm 3D RMS, and have been demonstrated to support sub-decimeter real time positioning and orbit determination for a variety of terrestrial, airborne, and spaceborne applications. In addition to the GPS differential corrections, TASS will provide real-time Earth orientation and solar flux information that enable precise onboard knowledge of the Earth-fixed position of the spacecraft, and precise orbit prediction and planning capabilities. TASS will also provide 5 seconds alarms for GPS integrity failures based on the unique GPS integrity monitoring service of the GDGPS System.

Global Postitioning Satellite (GPS)↗

Unstable and multiple pulsing can be invisible to ultrashort pulse measurement techniques

Here, multiple pulsing occurs in most ultrashort-pulse laser systems when pumped at excessively high powers, and small fluctuations in pump power in certain regimes can cause unusual variations in the temporal separations of sub-pulses. Unfortunately, the ability of modern intensity-and-phase pulse measurement techniques to measure such unstable multi-pulsing has not been studied. Here we report calculations and simulations finding that allowing variations in just the relative phase of a satellite pulse causes the second pulse to completely disappear from a spectral interferometry for direct electric field reconstruction (SPIDER) measurement. We find that, although neither frequency-resolved optical gating (FROG) nor autocorrelation can determine the precise properties of satellite pulses due to the presence of instability, they always succeed in, at least, seeing the satellite pulses. Also, additional post-processing of the measured FROG trace can determine the correct approximate relative height of the satellite pulse and definitively indicate the presence of unstable multiple-pulsing.

42 ENGINEERING↗