Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “moisture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Garnet solid electrolyte blended LiNi 0.6 Mn 0.2 Co 0.2 O 2 as high-voltage stable cathodes for advanced lithium-ion batteries

Ni-rich LiNi 1-x Co x/2 Mn x/2 O 2 layered materials have been widely adopted as cathodes for current electric vehicles (EVs) due to their high gravimetric and volumetric energy densities. However, their high-voltage instability (e.g., > 4.3 V vsLi ) limited their usable capacities corresponding to about 60 – 70 % of theoretical capacities. The major problems of high-voltage operation stem from instability of Ni 3+/4+ at cathode-electrolyte interphase (CEI) in contact with electrolytes. Here we propose garnet-type Li 6.7 La 3 Zr 1.7 Ta 0.3 O 12 (LLZT) solid-electrolyte-blended LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC) as high-voltage stable cathodes. The LLZT not only passivates the CEI but scavenges protons and moisture in electrolytes. From well-balanced ionic and electronic transport properties, 5 wt% LLZT blended NMC cathodes delivered enhanced electrochemical performances in full-cells. Unlike other complicated coating processes, our proposed solid-electrolyte blending approach can be readily implementable in commercial Li-ion batteries due to its manufacturing friendliness, energy saving, and cost effectiveness.

33 ADVANCED PROPULSION SYSTEMS↗

An experimental study on dehumidification and regeneration performance of a new nonporous membrane-based heat and mass exchanger using an ionic liquid desiccant

As a promising alternative to inefficient vapor-compression-based air conditioning, liquid desiccant dehumidification uses a liquid desiccant in contact with the humid air absorbing the moisture. However, it has not gained much market share due to the issues related to the carryover, corrosion, fouling, and crystallization of liquid desiccant. The research has developed a new membrane-based exchanger, which uses a non-corrosive ionic liquid desiccant and nonporous tubular membranes to address these issues. As the second generation of the prototype, the new exchanger was tested at various operating conditions. According to the experimental data, when it is used in the dehumidification loop, the new membrane-based exchanger achieves a specific vapor transportation rate of 778.6 g/(h–m 2 ) and an average water vapor flux of 0.316 g/(h-m 2 -Pa), which is a significant improvement compared with the previous designs using nonporous membranes. It also achieved a comparable or even better dehumidification performance compared with the dehumidifiers that use porous membrane and conventional liquid desiccants. However, the regeneration performance is not as good as its dehumidification. It is mainly caused by the high operating temperature required in the regeneration loop. The experimental data and findings provide first-hand experimental data and enhance the understanding of advanced membrane-based ionic liquid desiccant systems.

42 ENGINEERING↗

A direct contact cooler design for simultaneously recovering latent heat and capturing SO x and NO x from pressurized flue gas

Integrated SO x and NO x removal technology using a direct contact cooler is a promising alternative for cleaning coal combustion flue gas, especially for pressurized combustion systems. Past investigations of integrated SO x and NO x removal have been limited to low-temperature processes, where the flue gas has been cooled upstream of the removal unit, and the moisture in the flue gas has been condensed out. Here this work presents a novel design that recovers the flue gas heat while simultaneously removing SO x and NO x in a single reactive-absorption column – direct contact cooler. A validated model was used to evaluate different direct contact cooler designs. Modeling results suggested that a counter-current column with a single water inlet can scrub 83% of the NO x and 96.5% of the SO x in 115 s, while an optimized design with multiple water inlets enhances the scrubbing of NO x by 9 percentage points and SO x by 3.5 percentage points, due to a 34% increase in residence time. It is also observed that the liquid-phase reaction between absorbed SO x and NO x plays a significant role in the removal of SO 2 from the flue gas for high-temperature scrubbing compared with low-temperature scrubbing. The design reinforces the potential of high-temperature SO x -NO x removal and heat recovery and suggests a means of reducing capital costs for such columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of harvest and logistics for multiple lignocellulosic biomass feedstocks in the northeastern United States

A mixed-integer linear programming model was developed to optimize the multiple biomass feedstock supply chains, including feedstock establishment, harvest, storage, transportation, and preprocessing. The model was applied for analyses of multiple biomass feedstocks at county level for 13 states in the northeastern United States. In the base case with a demand of 180,000 dry Mg/year of biomass, the delivered costs ranged from $\$67.90$ to $\$86.97$ per dry Mg with an average of $\$79.58$ /dry Mg. The biomass delivered costs by county were from $\$67.90$ to 150.81 per dry Mg across the northeastern U.S. Considered the entire study area, the delivered cost averaged $\$85.30$ /dry Mg for forest residues, $\$84.47$ /dry Mg for hybrid willow, $\$99.68$ for switchgrass and $\$97.87$ per dry Mg for Miscanthus. Seventy seven out of 387 counties could be able to deliver biomass at $84 per dry Mg or less a target set by US DOE by 2022. A sensitivity analysis was also conducted to evaluate the effects of feedstock availability, feedstock price, moisture content, procurement radius, and facility demand on the delivered cost. Lastly, our results showed that procurement radius, facility capacity, and forest residue availability were the most sensitive factors affecting the biomass delivered costs.

09 BIOMASS FUELS↗

Influence of alkali-silica reaction on the shear capacity of reinforced concrete beams with minimum transverse reinforcement

A growing number of critical concrete infrastructure are affected by alkali-silica reaction (ASR) damage such as the Seabrook Nuclear Power Plant in New Hampshire, Parker arch-gravity dam in Arizona, and several highway bridges in California and Texas. ASR causes expansion and cracking and degrades the concrete mechanical properties. Despite a wealth of material level studies there is still limited large-scale experimental data regarding the effects of ASR on reinforced concrete (RC) members. Due to the brittle nature of the shear failure in RC structures, this study focuses on the shear response of full-scale ASR damaged RC beams with minimum shear reinforcement. Six RC beams were built with different levels of ASR susceptibility and conditioned in different environments during which continuous expansion monitoring was performed. The beams all contained reactive fine aggregate (sand) and two of them had additional alkali, 1.25% by weight of cement, to accelerate ASR. The highest expansion rate of the beams happened during the first 150 days and the expansions stayed constant after 240 days and 330 days for beams conditioned in outdoor and laboratory conditions, respectively, until the last measurement at 575 days. The highest expansion, 0.4%, was seen in the beams with additional alkali and conditioned outside with regular water spray. Out of the six beams, three were selected at different levels of ASR damage and two shear tests were performed on the minimally reinforced spans close to the ends of each beam. Results indicated that beams gain shear strength from ongoing cement hydration in the presence of moisture for ASR expansions less than 0.2%. Compared to one of the beams with 0.2% ASR expansion, one of the other samples with 0.4% expansion lost 6% of its shear strength, 25% of its shear stiffness, and showed about two times larger shear cracks and shear deformations at peak load. Finally, the shear reinforcement yielded at 20% less load in the beam with 0.4% expansion compared to the beam with 0.2% expansion.

42 ENGINEERING↗

Microbial functional genes commonly respond to elevated carbon dioxide

Atmospheric CO 2 concentration is increasing, largely due to anthropogenic activities. Previous studies of individual free-air CO 2 enrichment (FACE) experimental sites have shown significant impacts of elevated CO 2 (eCO 2 ) on soil microbial communities; however, no common microbial response patterns have yet emerged, challenging our ability to predict ecosystem functioning and sustainability in the future eCO 2 environment. Here we analyzed 66 soil microbial communities from five FACE sites, and showed common microbial response patterns to eCO 2 , especially for key functional genes involved in carbon and nitrogen fixation (e.g., pcc/acc for carbon fixation, nifH for nitrogen fixation), carbon decomposition (e.g., amyA and pulA for labile carbon decomposition, mnp and lcc for recalcitrant carbon decomposition), and greenhouse gas emissions (e.g., mcrA for methane production, norB for nitrous oxide production) across five FACE sites. Also, the relative abundance of those key genes was generally increased and directionally associated with increased biomass, soil carbon decomposition, and soil moisture. In addition, a further literature survey of more disparate FACE experimental sites indicated increased biomass, soil carbon decay, nitrogen fixation, methane and nitrous oxide emissions, plant and soil carbon and nitrogen under eCO 2 . A conceptual framework was developed to link commonly responsive functional genes with ecosystem processes, such as pcc/acc vs. soil carbon storage, amyA/pulA/mnp/lcc vs. soil carbon decomposition, and nifH vs. nitrogen availability, suggesting that such common responses of microbial functional genes may have the potential to predict ecosystem functioning and sustainability in the future eCO 2 environment.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental screening of salt hydrates for thermochemical energy storage for building heating application

The selection of a suitable salt hydrate for use in a thermochemical energy storage system is challenging. In this work, the most promising salts to store intermediate heat energy were selected and tested. The criteria set are; volumetric energy density of >500 kWh m-3 with a dehydration temperature of <100 degrees C, material cost of <3.5 USD kg-1 (<15 USD kWh-1), melting does not occur during dehydration and safety. Based on that, the salt hydrates SrCl 2 , MgSO 4 , Na 3 PO 4 , MgCl 2 and SrBr 2 were selected and tested experimentally. A constant temperature and humidity chamber was used to measure moisture sorption of different salts. The hydration is investigated under the conditions of 20 degrees C and 20, 30, 40, 60 and 80% RH, while dehydration is investigated under the conditions of 70, 100 and 140 degrees C using an oven. These dehydration temperatures of <100 degrees C are suitable for solar application whereas the dehydration temperature of 140 degrees C is suitable for waste heat. Furthermore, the salts are cycled over 30 times under the hydration conditions of 20 degrees C, 60% RH with a dehydration temperature of 100 degrees C. From these results, it is concluded that SrCl 2 and SrBr 2 are the most promising salts. This study outlines both the advantages and disadvantages of each salt and states the conditions they are most suitable for.

25 ENERGY STORAGE↗

Opportunities and challenges in thermochemical conversion of municipal solid waste: A comprehensive review

Recent advancements in thermochemical conversion processes have elucidated new pathways for converting municipal solid waste into valuable resources. This review explores the primary thermochemical conversion methods, including combustion, gasification, pyrolysis, torrefaction, hydrothermal carbonization, and hydrothermal liquefaction, emphasizing their potential roles in waste management and energy recovery. Key challenges including feedstock variability, ash behavior, and scale-up limitations are discussed alongside opportunities for hybrid systems and circular economy integration. A comparative analysis of research publications indicates a significant focus on thermochemical pathways within the broader context of municipal solid waste research, underscoring the growing interest in these technologies. Recent advancements in each thermochemical process, alongside their operational, technical, and economic challenges, are discussed. Comparative data reveal that torrefaction enhances the hydrophobicity and grindability of municipal solid waste components, though its energy densification benefits are more modest than those observed in biomass. Hydrothermal carbonization and liquefaction are highlighted for their ability to process high-moisture and heterogeneous waste streams. The review also synthesizes recent findings on reactor configurations, emissions control, and synergistic effects in co-processing municipal solid waste fractions. The findings underscore the importance of developing standardized protocols for municipal solid waste characterization and the need for innovative hybrid systems to improve efficiency.

99 - GENERAL AND MISCELLANEOUS↗

Contributions of anoxic microsites to soil carbon protection across soil textures

Anoxic microsites, zones of oxygen depletion in otherwise oxic soils, may slow soil C turnover. However, the abundance of anoxic microsites and their contribution to soil C protection is yet undefined. In this study, we determine the contribution of anoxic microsites to soil C protection in soils of three distinct textures (clay loam, loam, sandy loam) across a range of soil moistures. We examined the influence of soil oxygen supply by increasing oxygen content in the incubation atmosphere (oxygen enrichment) and through disaggregation. We attributed increases in CO 2 efflux to the aeration of anoxic microsites. The contribution of anoxic microsites to soil C protection increased with decreasing clay content. Clay loam CO 2 efflux was relatively unaffected by aeration. Moderately moist, loam soils had CO 2 effluxes that did not increase with oxygen enrichment but increased by 375% upon disaggregation. Sandy loam soil CO 2 efflux increased by 50–75% with oxygen enrichment and 250% with disaggregation. Geochemical and microbial data reveal that anoxic microsite abundance also increased with decreasing clay content. The proportion of acid extractable Fe present as Fe(II) increased with decreasing clay content, and methanogens were more abundant in loam and sandy loam soils. Our results suggest that oxygen demand, rather than supply, can regulate anoxic microsite formation and that anoxic protection of soil C can be diminished through physical disruption of soil structure. Our findings further illustrate that anoxic microsites should be included in conceptual models of soil C protection to avoid soil C loss and improve predictions of soil C response to disturbance.

58 GEOSCIENCES↗

Functional variability in specific root respiration translates to autotrophic differences in soil respiration in a temperate deciduous forest

CO 2 release from forest soils (R s ) is a prominent flux in the global carbon cycle. Rs is derived from roots (autotrophic respiration, R a ) and microbial (heterotrophic) respiration and is highly dynamic, as it depends on edaphic and environmental conditions as well as root functional traits and microbial community composition. It is unclear how root functional traits affect root and microbial respiration rates; however, their consideration may help parse out the relative contributions of root and microbial respiration to R s . At a temperate forest site, root systems of 3–4 functional root orders and their surrounding surface soil were carefully excavated and placed into custom trays designed to repeatedly measure R s in situ on eight temperate tree species that varied in their root functional strategies and mycorrhizal affinity. R s was measured bi-weekly to monthly for nearly one year using a custom chamber attached to a gas exchange system. R s varied over time, ranging from 0.3 to 12 µmol m -2 s -1 . Comparable root systems of the same species were excised from the soil and specific root respiration rates (R r ) were measured. Rr ranged from 2.5 to 9.0 nmol g -1 s -1 and was negatively correlated with root tissue density and positively related to root tissue nitrogen concentration. Using R r to estimate R a , we estimate that R a accounts for <10%, on average 2–3%, of R s for individual root systems (averaging 1.2 g dry biomass) housed in surrounding soil (average 1.3 kg dry mass) in situ; thus, Ra was roughly 20 times greater than Rh per unit mass. The contribution of R a peaked in the fall and coincided with leaf senescence of the forest canopy. A soil-sterilizing experimental treatment designed to help isolate R a in situ reduced bacterial biomass and shifted fungal community composition, but there was no reduction in Rs of the in-situ root-soil tray systems. The relative R a to R s ratio increased with root functional strategies characterized by greater specific root length and tip abundance, but also to greater root tissue density. The ratio of R a to R s also increased with warmer soil temperatures and decreased slightly with increasing soil moisture. We discuss how incorporating root functional traits as modulators of the autotrophic contribution to R s could be considered when modeling total soil CO 2 efflux from forests.

54 ENVIRONMENTAL SCIENCES↗

Interpreting the spatial distribution of soil properties with a physically-based distributed hydrological model

Digital soil maps are commonly data-driven as the development of physically-based models for soil mapping is difficult due to the complexity of soils. However, physically-based hydrologic models have been successful in simulating water dynamics. Since water movement is a major driver of pedogenesis, the physical rules that govern water movement might help explain and predict the spatial variation of soil properties. Here, we demonstrate the novel use of a physically-based, distributed hydrologic model to inform the spatial distribution of soil properties. The Distributed Hydrology Soil Vegetation Model (DHSVM) was utilized to simulate soil moisture content (SM) and water table depth (WTD) in two hillslope catchments under pasture and forest management wherein hydrologic model outputs were then compared with soil properties measured in situ. SM sensors and wells were installed in both catchments to validate simulations of soil water movement via Nash-Sutcliffe Efficiency (E). In-situ observations were made at 87 sites within both catchments to study the connection between simulated water movement (SM and WTD) and observed soil properties, namely the depth and thickness of the argillic (Bt), fragic (Btx), and C horizons, and the depth of redoximorphic features. The simulated time series of SM and WTD were also clustered per season using Dynamic Time Warping (DTW), which identified similarity among time series at varying timescales. Model validation suggested that simulations of surficial SM (0–20 cm) were reasonable (E = 0.45), however, simulated subsurface SM (45–60 cm) and WTD were not sufficiently accurate. The thickness of Btx horizons were spatially grouped into different populations by SM clusters from every season except spring. For the other properties, only SM dynamics of specific seasons grouped into significantly different populations, suggesting that the explanatory power of simulated water movement varies seasonally and was greater during winter. Here, we show clusters of simulated SM separated soil properties into statistically different populations, showing that hydrologic models could inform areas that followed different water dynamics related to pedogenic trajectories and related biogeochemical processes not necessarily simulated by the model. As such, physically-based modeling of water dynamics can, therefore, inform and advance digital soil mapping by linking water movement patterns stemming from hydrologic model outputs to spatial patterns of soil properties and pedogenesis.

54 ENVIRONMENTAL SCIENCES↗

Modeling the impact of high thermal conductivity paper on the performance and life of power transformers

Degradation of insulation paper is a key contributor to the failure of power transformers. Insulation degradation accelerates at elevated temperatures, which highlights the potential for better thermal management to prolong life. While several studies have analyzed the benefits of high thermal conductivity oil for reducing temperatures inside a transformer, this study is an initial assessment of the benefits of high thermal conductivity paper on transformer life. Blending particulates with cellulosic fibers offers a pathway for high thermal conductivity paper (with good dielectric properties), which can reduce internal temperatures. Presently, life extensions that can be achieved by the use of such thermally conducting papers were estimated, with the thermal conductivity of the paper being the key parameter under study. The analytical-numerical thermal model used in this study was validated against experimental measurements in a distribution transformer, adding confidence to the utility of the model. This model was then used to provide estimates of hot-spot temperature reduction resulting from the use of papers with higher thermal conductivity than baseline. Transformer life was predicted conventionally by tracking the degree of polymerization of paper over time, based on an Arrhenius model. Results indicate that increasing the thermal conductivity of paper from 0.2 W/mK (baseline) to 1W/mK reduces the hot spot temperature by 10°C. While degradation significantly depends on the moisture and oxygen content, the model shows that such a temperature reduction can increase life for all conditions, by as much as a factor of three.

42 ENGINEERING↗

A multiphase flow model of water droplets dielectrophoretic-induced air dehumidification phenomena

Air humidity in indoor spaces plays a critical role in human comfort and health. Dehumidification systems are used for building humidity controls, but they can take significant energy consumption, especially in geographic locations with high outdoor humidity and warm climates. Consequently, there is a growing demand for innovative dehumidification processes that consume minimal energy. Dielectrophoretic air dehumidification represents one such promising approach. However, it has not garnered significant attention due to the absence of engineering models and simulation tools capable of evaluating its performance and limitations at large-scale airflows. A new numerical multiphase CFD model, which is also experimentally validated, is developed in a customized Reacting Foam solver based on OpenFOAM® version 9. The newly developed model seeks to decrease substantial energy consumption and lower costs by leveraging the dielectrophoretic phenomenon to regulate moisture levels in the air. The solver integrates a hybrid Eulerian-Lagrangian framework to track the droplet's trajectory and growth rate while solving the continuum equations for the moist air. An electrospray produces electrically charged droplets, which grow during their in-flight trajectories as water vapor condenses onto their surfaces. The role of electrostatic forces in promoting vapor condensation within a high-gradient electrical field is investigated, and the dielectrophoretic vapor nucleation process on charged water droplets is discussed. The CFD model was validated against results from the literature and from proof-of-concept experiments conducted by the authors, which showed a 2 % air dehumidification with a single electrospray and airflow rate of 5 cubic feet per minute. The simulation results indicated that augmenting the number of electrically charged spray droplets increased the dehumidification of the air to 25 %. The initial mean droplet diameter, the orientation of the injector and relative humidity significantly influence the assessment of dehumidification. As a result, scaling up this approach to larger airflow volumes is identified as a potential future research direction.

42 ENGINEERING↗

Supercritical, liquid, and gas CO 2 reactive transport and carbonate formation in portland cement mortar

In this paper, we investigate carbonate formation and reactive transport rate in variably saturated portland cement mortars when high concentrations of gas, liquid, or supercritical CO 2 flow through their pore network. Xray computed tomography completed during CO 2 flow is used to quantify the microstructural evolution as the mortar carbonates. After in situ tests, higher resolution scans, thermogravimetric analysis, and desorption isotherm analysis are performed to further quantify microstructural changes. We found that at dry conditions supercritical CO 2 moves more rapidly through the pore space and precipitates more carbonates than liquid or gas CO 2 . However, at 50% degree of saturation (DOS) the CO 2 state did not affect the rate of transport in that each specimen exposed to a different CO 2 state carbonated within the first hour of CO 2 exposure. When the pore space is at 50 or 100% DOS, supercritical CO 2 did not react with hydration products more rapidly nor did it result in more carbonate formation during exposure compared to gas or liquid CO 2 . The amount of Ca(OH) 2 that contributes to CaCO 3 formation is correlated to the DOS. For the mortar composition analyzed, Ca(OH) 2 contributes to approximately 40% of the carbonates formed in the 50% DOS specimens and 15% in the 100% DOS specimens. In other words, as the amount of moisture in the pore space increases, phases other than Ca(OH) 2 contribute to more than 50% of the total CaCO 3 formed.

42 ENGINEERING↗

Alternating conduction and convection drying of paper – an experimental analysis with a continuous data acquisition approach

In conventional multi-cylinder drying of paper and board, both conductive drying from steam-heated dryer cylinders and convective drying by flowing air over the paper surface in the pockets are used. Conductive drying from steam-heated drying cylinders is a critical component in providing the necessary thermal energy to paper and board as they dry. Steam temperature and internal and external resistances at the contacting surface are critical process parameters influencing the conductive drying process. An experimental setup was developed to study the alternating conductive and convective drying of paper and board. Paper sheet moisture, temperature, and temperature distribution within the heated platen and the instantaneous heat flux as the sheet was being dried were measured. The instantaneous heat flux, contact heat transfer coefficient, and drying rates were determined as drying proceeds. Experimental results, as well as comparisons to literature and commercial data, are presented. The conductive heat transfer coefficients determined were compared to traditional correlations normally used in the modeling of paper drying. Similarly, the convective heat and mass transfer coefficients are also determined and compared to literature data. In addition to the evaluation of alternating conductive and convective drying characteristics of paper and board, the potential inclusion of auxiliary energy components will also be included. Experimental results from the conduction and convection drying system are presented. Furthermore, this data will be useful in process development, intensification of manufacturing processes, and modeling and simulation of paper drying processes.

42 ENGINEERING↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

Electrical, thermal, and H 2 O and CO 2 poisoning behaviors of PrNi 0.5 Co 0.5 O 3-δ electrode for intermediate temperature protonic ceramic electrochemical cells

PrNi 0.5 Co 0.5 O 3-δ (PNC) exhibits adequate total electrical conductivity (~300 S/cm at 400–600 °C) and moisture has no significant effect on it. The thermal expansion coefficient of PNC is 17.6 × 10 –6 /K by dilatometry and 18.43 × 10 –6 /K by in situ XRD. PNC also demonstrates chemical stability against H 2 O and CO 2 . However, PNC symmetrical cell over proton-conducting BaZr 0.4 Ce 0.4 Y 0.1 Yb 0.1 O 3-δ (BZCYYb4411) electrolyte shows significant H 2 O and CO 2 poisoning when those are introduced into O 2 –N 2 mixture. In comparison, symmetrical cells with PNC electrode over the oxygen ion conducting Ce 0.9 Gd 0.1 O 2-δ (GDC) electrolyte show no H 2 O and CO 2 poisoning under similar conditions. Here, it is hypothesized that poisoning from H 2 O and CO 2 of the PNC proton conducting symmetrical cell is caused by their adsorption on the BZCYYb4411 electrolyte instead of PNC electrode. Such a hypothesis is supported by the H 2 O and CO 2 adsorption behaviors on PNC and BZCYYb4411 powder surfaces, as measured by temperature programmed desorption (TPD).