Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “minimum loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Ignition and combustion characteristics of metallized propellants

Experimental and analytical investigations focusing on secondary atomization and ignition characteristics of aluminum/liquid hydrocarbon slurry propellants were conducted. Experimental efforts included the application of a laser-based, two-color, forward-scatter technique to simultaneously measure free-flying slurry droplet diameters and velocities for droplet diameters in the range of 10-200 microns. A multi-diffusion flame burner was used to create a high-temperature environment into which a dilute stream of slurry droplets could be introduced. Narrowband measurements of radiant emission were used to determine if ignition of the aluminum in the slurry droplet had occurred. Models of slurry droplet shell formation were applied to aluminum/liquid hydrocarbon propellants and used to ascertain the effects of solids loading and ultimate particle size on the minimum droplet diameter that will permit secondary atomization. For a 60 weight-percent Al slurry, the limiting critical diameter was predicted to be 34.7 microns which is somewhat greater than the 20-25 micron limiting diameters determined in the experiments. A previously developed model of aluminum ignition in a slurry droplet was applied to the present experiments and found to predict ignition times in reasonable agreement with experimental measurements. A model was also developed that predicts the mechanical stress in the droplet shell and a parametric study was conducted. A one-dimensional model of a slurry-fueled rocket combustion chamber was developed. This model includes the processes of liquid hydrocarbon burnout, secondary atomization, aluminum ignition, and aluminum combustion. Also included is a model for radiant heat transfer from the hot aluminum oxide particles to the chamber walls. Exercising this model shows that only a modest amount of secondary atomization is required to reduce residence times for aluminum burnout, and thereby maintain relatively short chamber lengths. The model also predicts radiant heat transfer losses to the walls to be only approximately 3 percent of the fuel energy supplied. Additional work is required to determine the effects of secondary atomization on two-phase losses in the nozzle.

Turns, Stephen R.↗

Traveling-Wave Tube Amplifier Model to Predict High-Order Modulation Intersymbol Interference

Demands for increased data rates in satellite communications necessitate higher order modulation schemes, larger system bandwidth, and minimum distortion of the modulated signal as it is passed through the traveling wave tube amplifier (TWTA). One type of distortion that the TWTA contributes to is intersymbol interference (ISI), and this becomes particularly disruptive with wide-band, complex modulation schemes. It is suspected that in addition to the dispersion of the TWT, frequency dependent reflections due to mismatches within the TWT are a significant contributor to ISI. To experimentally investigate the effect of these mismatches within the physical TWT on ISI would be prohibitively expensive, as it would require manufacturing numerous amplifiers in addition to the acquisition of the required digital hardware. In an attempt to develop a more accurate model to correlate IS1 with the TWTA and the operational signal, a fully three-dimensional (3D), time-dependent, TWT interaction model has been developed using the electromagnetic particle-in-cell (PIC) code MAFIA (solution of Maxwell's equations by the Finite-Integration-Algorithm). The model includes a user defined slow-wave circuit with a spatially tapered region of loss to implement a sever, and spatially varied geometry (such as helical pitch) to implement a phase velocity taper. The model also includes user defined input/output coupling and an electron beam contained by solenoidal, electrostatic, or periodic permanent magnet (PPM) focusing allowing standard or novel TWTs to be investigated. This model comprehensively takes into account the effects of frequency dependent nonlinear distortions (MAM and AMPM); gain ripple due to frequency dependent reflections at the input/output coupling, severs, and mismatches from dynamic pitch variations; drive induced oscillations; harmonic generation; intermodulation products; and backward waves.

Kory, Carol L.↗

Experimental test of Landauer’s principle in single-bit operations on nanomagnetic memory bits

Minimizing energy dissipation has emerged as the key challenge in continuing to scale the performance of digital computers. The question of whether there exists a fundamental lower limit to the energy required for digital operations is therefore of great interest. A well-known theoretical result put forward by Landauer states that any irreversible single-bit operation on a physical memory element in contact with a heat bath at a temperature T requires at least k B T ln(2) of heat be dissipated from the memory into the environment, where k B is the Boltzmann constant. We report an experimental investigation of the intrinsic energy loss of an adiabatic single-bit reset operation using nanoscale magnetic memory bits, by far the most ubiquitous digital storage technology in use today. Through sensitive, high-precision magnetometry measurements, we observed that the amount of dissipated energy in this process is consistent (within 2 SDs of experimental uncertainty) with the Landauer limit. This result reinforces the connection between “information thermodynamics” and physical systems and also provides a foundation for the development of practical information processing technologies that approach the fundamental limit of energy dissipation. The significance of the result includes insightful direction for future development of information technology.

42 ENGINEERING↗

UPDATED PHOTOMETRY AND ORBITAL PERIOD ANALYSIS FOR THE POLAR AM HERCULIS ON THE UPPER EDGE OF THE PERIOD GAP

Twenty-one new optical light curves, including five curves obtained in 2009 and sixteen curves detected from the AAVSO International Database spanning from 1977 to 2011, demonstrate 16 new primary minimum light times in the high state. Furthermore, seven newly found low-state transient events from 2006 to 2009 were discovered, consisting of five Gaussian-shaped events and two events with an exponential form with decay timescales of <0.005 days; these timescales are one order of magnitude shorter than those of previous X-ray flare events. In the state transition, two special events were detected: a ''disrupted event'' with an amplitude of {approx}2 mag and a duration of {approx}72 minutes and continuing R-band twin events larger than all known R-band flares detected in M-type red dwarfs. All 45 available high-state data points spanning over 35 yr were used to construct an updated O - C diagram of AM Herculis, which clearly shows a significant sine-like variation with a period of 12-15 yr and an amplitude of 6-9 minutes. Using the inspected physical parameters of the donor star, the secular variation in the O - C diagram cannot be interpreted by any decided angular momentum loss mechanism, but can satisfy the condition {tau}{sub M-dot{sub {sub {sub 2}}}}{approx_equal}{tau}{sub KH}>>{tau}{sub R-dot{sub {sub {sub 2}}}}, which is required by numerical calculations of the secular evolution of cataclysmic variables. In order to explain the prominent periodic modulation, three plausible mechanisms-spot motion, the light travel-time effect, and magnetic active cycles-are discussed in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Major Geomagnetic Storms (Dst less than or equal to -100 nT) Generated by Corotating Interaction Regions

Seventy-nine major geomagnetic storms (minimum Dst less than or equal to -100 nT) observed in 1996 to 2004 were the focus of a Living with a Star Coordinated Data-Analysis Workshop (CDAW) in March, 2005. In 9 cases, the storm driver appears to have been purely a corotating interaction region (CIR) without any contribution from coronal mass ejection-related material (interplanetary coronal mass ejections, ICMEs). These storms were generated by structures within CIRs located both before and/or after the stream interface that included persistently southward magnetic fields for intervals of several hours. We compare their geomagnetic effects with those of 159 CIRs observed during 1996 - 2005. The major storms form the extreme tail of a continuous distribution of CIR geoeffectiveness which peaks at Dst approx. -40 nT but is subject to a prominent seasonal variation of - 40 nT which is ordered by the spring and fall equinoxes and the solar wind magnetic field direction towards or away from the Sun. The O'Brien and McPherron [2000] equations, which estimate Dst by integrating the incident solar wind electric field and incorporating a ring current loss term, largely account for the variation in storm size. They tend to underestimate the size of the larger CIR-associated storms by Dst approx. 20 nT. This suggests that injection into the ring current may be more efficient than expected in such storms. Four of the nine major storms in 1996 - 2004 occurred during a period of less than three solar rotations in September - November, 2002, also the time of maximum mean IMF and solar magnetic field intensity during the current solar cycle. The maximum CIR-storm strength found in our sample of events, plus additional 23 probable CIR-associated Dst less than or equal to -100 nT storms in 1972 - 1995, is (Dst = -161 nT). This is consistent with the maximum storm strength (Dst approx. -180 nT) expected from the O'Brien and McPherron equations for the typical range of solar wind electric fields associated with CIRs. This suggests that CIRs alone are unlikely to generate geomagnetic storms that exceed these levels.

Richardson, I. G.↗

Full Stall Simulations of a Redesigned Ventilation Fan for the ISS

The concept of a stall is studied rigorously in the aerospace industry. From a design standpoint, instabilities such as stall are undesirable– operation in the stall regime has a tremendous impact on aerodynamic performance as well as structural integrity. In extreme cases, operating in stall conditions can cause failure. Further, stall can cause a loss of lift on aircraft wings or a loss of thrust in aircraft engines. In any case, stall continues to be a topic of interest in the aerospace industry. The present work aims to analyze the stall characteristics of a ventilation fan that was recently designed for the International Space Station (ISS). Although the ventilation fan has a rotor-stator design, this paper considers a rotor-only configuration. The FUN3D Computational Fluid Dynamic (CFD) solver developed by NASA Langley Research Center was used to simulate the operational characteristics of the ventilation fan. FUN3D solves the Unsteady Reynolds-Averaged Naiver-Stokes (URANS) equations using implicit time marching and a dynamic overset grid. The FUN3D solver was originally written for exterior flow fields; however, this work represents an extension of the FUN3D solver to turbomachinery or interior flow fields. The FUN3D results for the rotor-only ventilation fan accurately captured the operational characteristics inherent to compressors– the results shared similar performance trends when compared to the experimental results for the rotor-stator case. A peak adiabatic efficiency of 96% occurred at a MFR of 105.2 CFM, the minimum aerodynamically stable point. A computationally stable stall occurred at a mass flow rate of 43.8 CFM where the adiabatic efficiency dropped to 69%.

CFD↗

A Statistical Approach to Safety Margin Evaluation of Irradiation Experiments in the ATR

The current safety basis of the INL Advanced Test Reactor requires that irradiation experiments meet minimum safety margins to critical heat flux and flow instability during anticipated reactor fault conditions. Compliance to these requirements may be demonstrated by calculating safety margins using safety factors that account for uncertainties, or using a statistical approach to quantify the uncertainty in the safety margins. Safety margins obtained from the first approach are conservative since the individual events leading to the cumulative safety factor are assumed to occur simultaneously at their maximum uncertainty. The statistical approach is less conservative in the case where the uncertainties are not too large, and may reduce the conservatism resulting from an overabundance of safety factors. This report describes the procedure for safety margin evaluation using a statistical approach and identifies the important thermal-hydraulic variables to consider in an uncertainty analysis. In particular, safety margins to critical heat flux and flow instability are evaluated for three recent high power fueled experiments (MP-1, FSP-1 and AFIP-6) using RELAP5 coupled to RAVEN to perform statistical analysis and uncertainty quantification. The results demonstrate adequate safety margins to critical heat flux and flow instability during an anticipated loss of commercial power to the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Determination of Parachute Joint Factors using Seam and Joint Testing

This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

Mollmann, Catherine↗

Robust wind farm layout optimization

Wake interactions in wind farms cause losses in annual energy production (AEP) on the order of 10%. Wind farm designers optimize the layout of the farm to mitigate wake losses, especially in the dominant site-specific wind directions. As wind turbines and wind farms grow in scale, optimization becomes more complex. Offshore wind farms regularly comprise more than 100 wind turbines and are characterized by complex boundaries due to shipping lanes, neighboring wind farms, and other constraints. Layout optimization methods are broadly split between gradient-based and gradient-free approaches. Gradient-based approaches can converge quickly and perform well for smaller, academic problems but are often sensitive to initial conditions and tuning parameters and require expert knowledge to use. On the other hand, gradient-free approaches can be more robust to problem complexities. We present a robust layout optimization approach based on a random search algorithm. The algorithm is intended for those who are not optimization experts and has few tuning parameters that need specification to achieve satisfactory results. Unlike off-the-shelf methods, which use generally available, non-domain-specific optimization routines that accept as inputs an optimization function and constraint definitions, this approach takes advantage of the relative computational costs of the different evaluations by evaluating cheaper computations first (boundary and minimum distance constraints) and running expensive AEP evaluations only if all other checks pass. Moreover, an outer genetic algorithm allows multiple solutions to evolve in parallel, enabling rapid solution development on high-performance computers. We discuss the relative ease of selecting necessary tuning parameters and demonstrate the efficacy of the genetic random search on a complex layout problem consisting of placing 70 turbines in a nonconvex and unconnected boundary region.

17 WIND ENERGY↗

Combined Sorbent/WGS-based CO 2 Capture Process with Integrated Heat Management for IGCC Systems

Southern Research has developed a combined CO 2 capture water-gas shift (WGS) process for integrated gasification combined cycle (IGCC) applications. A highly efficient regenerable magnesium based sorbent was prepared to remove CO 2 . It offers high and stable CO 2 capacity with minimum requirement for temperature and pressure swings. Under optimized conditions, the sorbents achieved up to 8 mmol/g of CO 2 working capacity and remained stable over 500 cycles of adsorption and regeneration. The selected WGS process achieved 96% CO per pass conversion and remained isothermal during the test duration that lasted over 500 cycles. The approach showed potential to reduce cost of electricity (COE) compared to the baseline carbon capture approaches. The process is for bench-scale and pilot development. In a commercial embodiment, syngas from the gasifier is cooled to warm gas conditions. It then enters the CO 2 sorbent-shift reactor that uses an efficient MgO-based CO 2 sorbent and a commercial catalyst to shift the CO to CO 2 and capture 90% + of the carbon. Using a dual-bed arrangement, the sorbent is regenerated periodically by a combination of pressure and temperature swing to maintain steady state conditions and produce a 95+ % CO 2 stream for sequestration. The hydrogen rich syngas is sent to the IGCC for power production. In addition to consolidating CO 2 capture with WGS, the proposed process reduces parasitic energy losses by operating at warm gas temperatures and reduces parasitic plant load (i.e., steam and auxiliary power) by reducing energy required for regeneration. The project consisted of 3 budget periods (BP) of laboratory-scale research and testing with go/no-go decisions after BP-1 and BP-2. In the 12 month BP-1, it was shown show that one promising sorbent maintained the required CO 2 capacity and durability of >1.5 mmol/g over 100 cycles. Also based on sorbent and WGS experiments in separate reactors and combined reactor modeling, it was shown that the process had the potential to capture 90% of the CO 2 at a lower than conventional amine-based approach. In the 18 month BP-2, a lab scale combined sorbent/WGS reactor system was built, commissioned, and tested with the promising sorbent from BP-1. 90% carbon capture was demonstrated over 100 cycles and it was shown that the process continued to have potential to capture 90% of the carbon at a cost that was less than the conventional amine-based approach. In the 6 month BP-3, a long term test was conducted using the best SR sorbent. The required durability of > 2 mmol/g was demonstrated after 500 cycles. Also, 90% carbon capture and 96% CO conversion was maintained over 1000 cycles. A technical and economic feasibility study was carried out to compare the proposed pre-combustion approach to a gasification plant employing a conventional pre-combustion approach and a conventional pulverized caol (PC) plant employing a conventional post combustion CO 2 capture approach.

01 COAL, LIGNITE, AND PEAT↗

Internal cycle modeling and environmental assessment of multiple cycle consumer products

Highlights: Black-Right-Pointing-Pointer Dynamic flow models are presented for remanufactured, reused or recycled products. Black-Right-Pointing-Pointer Early loss and stochastic return are included for fast and slow cycling products. Black-Right-Pointing-Pointer The reuse-to-input flow ratio (Internal Cycle Factor, ICF) is determined. Black-Right-Pointing-Pointer The cycle rate, which is increasing with the ICF, monitors eco-performance. Black-Right-Pointing-Pointer Early internal cycle losses diminish the ICF, the cycle rate and performance. - Abstract: Dynamic annual flow models incorporating consumer discard and usage loss and featuring deterministic and stochastic end-of-cycle (EOC) return by the consumer are developed for reused or remanufactured products (multiple cycle products, MCPs), including fast and slow cycling, short and long-lived products. It is shown that internal flows (reuse and overall consumption) increase proportionally to the dimensionless internal cycle factor (ICF) which is related to environmental impact reduction factors. The combined reuse/recycle (or cycle) rate is shown capable for shortcut, albeit effective, monitoring of environmental performance in terms of waste production, virgin material extraction and manufacturing impacts of all MCPs, a task, which physical variables (lifetime, cycling frequency, mean or total number of return trips) and conventional rates, via which environmental policy has been officially implemented (e.g. recycling rate) cannot accomplish. The cycle rate is shown to be an increasing (hyperbolic) function of ICF. The impact of the stochastic EOC return characteristics on total reuse and consumption flows, as well as on eco-performance, is assessed: symmetric EOC return has a small, positive effect on performance compared to deterministic, while early shifted EOC return is more beneficial. In order to be efficient, environmental policy should set higher minimum reuse targets for higher trippage MCPs. The results may serve for monitoring, flow accounting and comparative eco-assessment of MCPs. They may be useful in identifying reachable and efficient reuse/recycle targets for consumer products and in planning return via appropriate labelling and digital coding for enhancing environmental performance, while satisfying consumer demand.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Economics of Hybrid-Energy Systems and the Impact on Advanced Reactor Design and Operation

The economics of electricity production in the U.S. is changing with the introduction of recent federal regulations limiting carbon dioxide emissions in the electric power industry. This has already resulted in the closing of coal plants, plants which in the past to a degree served to balance production with daily variation in load. The resulting loss of electricity production is being made up with wind and solar renewables and gas-fired units, and with an increasing need for energy storage. It would appear that with the loss of the baseload component of the coal plants, the duty-cycle of the gas-fired units may necessarily increase, encroaching on the traditional nuclear plant domain with its inexpensive fuel. Gas plants are costly to operate on a continuous basis with relatively volatile fuel prices. It appears then that nuclear plants that are capable of flexible operation have the potential on an economic basis to displace gas-fired power units. For flexible operation with renewables advanced reactors have advantages over the current generation of pressurized water reactors (PWR) and the new small modular reactors (SMR). For PWRs and SMRs, pellet-cladding mechanical interaction, xenon poisoning, and thermal stress concentrations in structures place limits on the all-important response time for operation with renewables. These phenomena are, however, not as limiting for the liquid-metal fast reactor (LMR). This may permit greater power ramp rates than in a light water reactor which bestows an economic advantage in energy systems with renewables. An economic model is developed for studying electric grid options including plant mix and market rules for the case of a high renewable fraction. It returns the minimum cost solution from among a mix of plant types including nuclear, gas, and storage (i.e. hybrid energy systems) for a given fraction of electricity production by renewables. This model can be used to assess the economic advantage of nuclear plants over gas plants and advanced reactors over light water reactors in an electric grid with a high fraction of renewables. The model has an explicit treatment of plant dynamic effects, an important feature for analysis of hybrid energy systems with a renewables production component that is unpredictable and uncontrollable.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Controls on the CO2 seasonal cycle

Surface pressure measurement performed by the Viking landers show substantial variations in pressure on seasonal timescales that are characterized by two local minima and two local maxima. These variations have widely been attributed to the seasonal condensation and sublimation of CO2 in the two polar regions. It has been somewhat of a surprise that the amplitude of the minimum and maximum that is dominated by the CO2 cycle in the north was much weaker than the corresponding amplitude of the south-dominated extrema. Another surprise was that the seasonal pressure cycle during years 2 and 3 of the Viking mission was so similar to that for year 1, despite the occurrence of two global dust storms during year 1 and none during years 2 and 3. An energy balance model that incorporates dynamical factors from general circulation model (GCM) runs in which the atmospheric dust opacity and seasonal date were systematically varied was used to model the observed seasonal pressure variations. The energy balance takes account of the following processes in determining the rates of CO2 condensation and sublimation at each longitudinal and latitudinal grid point: solar radiation, infrared radiation from the atmosphere and surface, subsurface heat conduction, and atmospheric heat advection. Condensation rates are calculated both at the surface and in the atmosphere. In addition, the energy balance model also incorporates information from the GCM runs on seasonal redistribution of surface pressure across the globe. Estimates of surface temperature of the seasonal CO2 caps were used to define the infrared radiative losses from the seasonal polar caps. The seasonal pressure variations measured at the Viking lander sites were closely reproduced.

Pollack, J. B.↗

DISCOVERY OF THE OPTICAL/ULTRAVIOLET/GAMMA-RAY COUNTERPART TO THE ECLIPSING MILLISECOND PULSAR J1816+4510

The energetic, eclipsing millisecond pulsar J1816+4510 was recently discovered in a low-frequency radio survey with the Green Bank Telescope. With an orbital period of 8.7 hr and a minimum companion mass of 0.16 M{sub Sun }, it appears to belong to an increasingly important class of pulsars that are ablating their low-mass companions. We report the discovery of the {gamma}-ray counterpart to this pulsar and present a likely optical/ultraviolet counterpart as well. Using the radio ephemeris, we detect pulsations in the unclassified {gamma}-ray source 2FGL J1816.5+4511, implying an efficiency of {approx}25% in converting the pulsar's spin-down luminosity into {gamma}-rays and adding PSR J1816+4510 to the large number of millisecond pulsars detected by Fermi. The likely optical/UV counterpart was identified through position coincidence (<0.''1) and unusual colors. Assuming that it is the companion, with R = 18.27 {+-} 0.03 mag and effective temperature {approx}> 15,000 K, it would be among the brightest and hottest of low-mass pulsar companions and appears qualitatively different from other eclipsing pulsar systems. In particular, current data suggest that it is a factor of two larger than most white dwarfs of its mass but a factor of four smaller than its Roche lobe. We discuss possible reasons for its high temperature and odd size, and suggest that it recently underwent a violent episode of mass loss. Regardless of origin, its brightness and the relative unimportance of irradiation make it an ideal target for a mass, and hence a neutron star mass, determination.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Thermal Storage on the Performance of a Wood Pellet-fired Residential Boiler

Interest in the direct use of biomass for thermal applications as a renewable technology is increasing as is also focus on air pollutant emissions from these sources and methods to minimize the impact. This work has focused on wood pellet-fired residential boilers, which are the cleanest fuel in this category. In the residential application the load varies strongly over the course of a year and a high fraction of the load is typically under 15% of the maximum boiler capacity. Thermal storage can be used even with boilers which have modulation capacity typically to 30% of the boiler maximum. One common pellet boiler was tested at full load and also at the minimum load used in the U.S. certification testing (15%). In these tests the load was steady over the test period. Testing was also done with an emulated load profile for a home in Albany, N.Y. on a typical January, March, and April day. In this case the load imposed on the boiler varied hourly under computer control, based on the modeled load for the example case used. The boiler used has a nominal output of 25 kW and a common mixed hardwood/softwood commercial pellet was used. Moisture content was 3.77%. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements. The test results showed that the use of storage strongly reduces cycling rates under part load conditions. The transients which occur as these boilers cycle contribute to increased particulate emissions and reduced efficiency. The time period of a full cycle at a given load condition can be increased by increasing the storage tank volume and/or increasing the control differential range. It was shown that increasing the period strongly increased the measured efficiency and reduced the particulate emission (relative to the no storage case). The impact was most significant at the low load levels. Storage tank heat loss is shown to be a significant factor in thermal efficiency, particularly at low load. Different methods to measure this heat loss were explored. For one of the tanks evaluated the efficiency loss at the 15% load point was found to be as high as 7.9%. Where storage is used good insulation on the tank, insulation on the piping, and attention to fittings are recommended.

09 BIOMASS FUELS↗

Investigations of dual-purpose canister direct disposal feasibility - 15106

Direct disposal of commercial spent nuclear fuel (SNF) in dual-purpose canisters (DPCs) could avoid the cost and complexity of re-packaging spent fuel into smaller purpose-built containers, avoid disposing of the DPC hulls as low-level waste, and potentially decrease worker dose. Technical objectives for disposal are: 1) safety of workers and the public, 2) engineering feasibility; 3) thermal management; and 4) criticality control after permanent closure of a repository. The postclosure safety case for DPC direct disposal would resemble that for any repository-waste isolation would be enhanced by choosing host geology in which radionuclide transport is diffusion dominated, and for which transport properties and pathways are insensitive to the expected temperature history. Containment functions would be assigned to the disposal overpack, and published data show that suitable materials exist for most possible disposal environments. Earlier studies showed that DPC-based waste packages would be only slightly larger and heavier than those proposed for a repository in volcanic tuff. Engineered solutions are available for transporting and emplacing them underground, although some could be the largest of their kind. The cost of DPC direct disposal in various geologic settings has been compared to options involving a change to loading standardized multi-purpose canisters, or continuing to load DPCs and re-packaging all of them for disposal. In general DPC direct disposal would cost tens of billions of dollars less, in packaging and disposal costs. Calculations for emplacement in hard rock and sedimentary rock show that host rock peak temperature targets of 100 to 200 deg.C could be met by managing fuel age and burnup, with repository closure at up to 150 years from reactor discharge. For disposal in salt, DPC-based waste packages could be emplaced at only 50 to 100 years from discharge, depending on burnup. Sedimentary media such as shales pose special challenges especially if they have low thermal conductivity. If backfill is used around DPC-based packages its peak temperature could be 150 to 200 deg.C. Without flooding of waste packages with ground water, criticality can never occur. However, some small number of disposal overpacks could fail within the postclosure performance period due to corrosion or disruptive events. Once flooded, the aluminum-based neutron absorber materials used in most DPCs would readily degrade. Analysis has shown that even without neutron absorbers, virtually all DPCs could be subcritical if flooded with chloride brines such as would occur in a salt repository. The licensing basis for existing DPCs involves criticality analysis that may be conservative compared to fuel that is actually loaded, and the difference provides uncredited reactivity margin. Uncredited margin can offset increases in reactivity associated with flooding and basket degradation. For flooding with fresh water, with loss of neutron absorbers, many DPCs have been shown to be subcritical using uncredited margin. Significantly fewer are subcritical if the fuel basket also degrades. Thus, the materials of DPC basket construction (e.g., aluminum or carbon steel) could be deleterious if they fully corrode, along with the neutron absorbers, during the performance period. Logistical simulations are used to better understand the relationship between the needed DPC decay storage time for disposal, and the timing of future events such as the repository opening date, or a transition to loading multi-purpose (disposable) canisters at nuclear power plants. Results show that the maximum benefit from implementing a new canister design, with respect to shortening the cooling time for all SNF including that in DPCs, is associated with the earliest repository start date. As time passes more of the total SNF inventory will be in DPCs such that the value of a transition to multi-purpose canisters will decline, and the remaining options are DPC direct disposal and re-packaging in purpose-designed disposal canisters. Fuel age at emplacement is of interest to evaluate potential impacts from future changes in the fuel management system that could place fuel age limits on dry storage or transportation. The minimum fuel age at emplacement (best-case) is obtained by re-packaging all DPCs into smaller canisters for disposal, thus drastically decreasing the needed decay storage time for any geologic disposal setting. If the industry transitions to smaller, multi-purpose canisters, and without re-packaging, the fuel age at emplacement would be comparable to the best case if: 1) the emplacement power limit is high enough, or 2) both the transition and the repository start date occur early (e.g., 2036 was analyzed). Technical feasibility evaluation continues to show that direct disposal could be safe and cost effective, for some DPCs and in some geologic settings. Direct disposal of a substantial fraction of existing DPCs, limited mainly by thermal management, uncredited criticality margin, materials of DPC basket construction, and the salinity of ground water in the disposal environment, could be part of the overall waste management system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mirages and the nature of Pluto's atmosphere

We present model occultation lightcurves demonstrating that a strong thermal inversion layer at the base of Pluto's stratosphere can reproduce the minimum flux measured by the Kuiper Airborne Observatory (KAO) during the 1988 occultation of a star by Pluto. The inversion layer also forms the occultation equivalent of a mirage at a radius of 1198 km, which is capable of hiding tropospheres of significant depth. Pluto's surface lies below 1198 km, its radius depending on the depth of the troposphere. We begin by computing plausible temperature structures for Pluto's lower atmosphere, constrained by a calculation of the temperature of the atmosphere near the surface. We then trace rays from the occulted star through the model atmosphere, computing the resultant bending of the ray. Model light curves are obtained by summing the contribution of individual rays within the shadow of Pluto on Earth. We find that we can reproduce the KAO lightcurve using model atmospheres with a temperature inversion and no haze. We have explored models with tropospheres as deep as 40 km (implying a Pluto radius of 1158 km) that reproduce the suite of occultation data. Deeper tropospheres can be fitted to the data, but the mutual event radius of 1150 km probably provides a lower bound. If Pluto has a shallow or nonexistent troposphere, its density is consistent with formation in the solar nebula with modest water loss due to impact ejection. If the troposhere is relatively deep, implying a smaller radius and larger density, significant amounts of water loss are required.

Stansberry, J. A.↗

Design and optimization of flexible decoupled high-temperature gas-cooled reactor plants with thermal energy storage

Advanced nuclear power plants are well-positioned for future zero-carbon grids, however, the need for flexible power generation will be required over the traditional emphasis on baseload generation for meeting historical demands. To achieve such flexibility, this work examines viable configurations for coupling nuclear energy production with thermal energy storage. Previous designs on nuclear-thermal energy storage configurations for advanced reactor designs, which utilized reactor steam as the heat source for charging the thermal energy storage, are restricted by the heat diversion ratio and efficiency losses, thus their impacts can be limited. In this context, this study proposes configurations for fully decoupling the nuclear reactor from the power cycle and positioning the storage as an intermediate loop, thereby achieving an unconstrained heat diversion ratio and improved efficiency. Compared with a standard high-temperature gas-cooled reactor’s power cycle, steady-state thermodynamic modeling and dispatch optimizations quantify the benefits of a steam reheat cycle within the fully decoupled thermal energy system to separate the plant cycle from the high-pressure primary side. These benefits are further detailed, compatible with required high-temperature and high-pressure conditions, through (1) open-source dynamic transient models that examine the impact of off-design operation on the systems, (2) the investigation of components design and costing and finally (3) sizing and dispatch optimization. The fully-decoupled design achieves a cycle efficiency of 43.1%, an enhancement over the vendor’s standard efficiency of 42.2% (Xe-100 design). Here, the proposed design offers strengthened physical barriers from the nuclear island as well as superior operational flexibility and power boosting. Dispatch optimization and market analysis reveal that thermal energy storage size is highly dependent on the peak patterns of electricity prices and the minimum generation level constraint imposed on the balance of plant. Evaluation of off-design operation demonstrates that the full decoupling design with the suggested fail-safe control mechanisms ensures a minimal impact on reactor parameters, even during rapid power ramping.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗