Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

End-use load profiles (EULP), which quantify how and when energy is used, are critically important to utilities, public utility commissions, state energy offices, and other stakeholders. Applications of EULPs focus on understanding how efficiency, demand response, and other distributed energy resources are valued and used in R&D prioritization, utility resource and distribution system planning, and state and local energy planning and regulations. Consequently, high-quality EULPs are critical for widespread adoption of electrification, demand flexibility, and grid-interactive efficient buildings. For example, EULPs can be used to forecast energy savings in buildings or to identify energy using activities that can be shifted to different times of the day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Empirical Effect of Fleet Optimization on Synchronization and Rebound Effects in Heat Pump Water Heaters

Demand response is a growing concept in light of the internet of things and an increasing need for grid flexibility. Water heaters are one of the preferred devices for providing demand response for grid services and peak management due to their capability to store energy. The efficient use of water heaters for demand response requires consideration of the associated load effects such as synchronization of device schedules and rebound effect. These effects present a significant challenge. Despite the importance of the mentioned effects for water heater queuing and scheduling, there has been no effort to quantify and empirically validate their impact. This study attempts to address this gap by offering two methods - Ward clustering and Euclidean K-means - to evaluate the extent of synchronization in a fleet of 42 water heaters in Atlanta, GA. Using the aforementioned methods on the measured data, we find evidence of convergence of water heater loads as a result of optimization compared to an idle period and analyzed their impact.

demand response↗

Analyzing the Effects of Climate and Thermal Configuration on Community Energy Storage Systems (Presentation)

Community energy storage (CES) has been proposed to mitigate the high variation in output from renewable sources and reduce peak load on the electrical grid. Thousands of these systems may be distributed around the grid to provide benefits to local distribution circuits and to the grid as a whole when aggregated. CES must be low cost to purchase and install and also largely maintenance free through more than 10 years of service life to be acceptable to most utilities.Achieving the required system life time is a major uncertainty for lithium-ion batteries. The lifetime and immediate system performance of batteries can change drastically with battery temperature, which is a strong function of system packaging, local climate, electrical duty cycle, and other factors. In other Li-ion applications, this problem is solved via air or liquid heating and cooling systems that may need occasional maintenance throughout their service life. CES requires a maintenance-free thermal management system providing protection from environmental conditions while rejecting heat from a moderate electrical duty cycle. Thus, the development of an effective, low-cost, zero-maintenance thermal management system poses a challenge critical to the success of CES. NREL and Southern California Edison have collaborated to evaluate the long-term effectiveness of various CES thermal configurations in multiple climates by building a model of CES based on collected test data, integrating it with an NREL-developed Li-ion degradation model, and applying CES electrical duty cycles and historic location-specific meteorological data to forecast battery thermal response and degradation through a 10-year service life.

25 ENERGY STORAGE↗

Electric load shape benchmarking for small- and medium-sized commercial buildings

Small- and medium-sized commercial buildings owners and utility managers often look for opportunities for energy cost savings through energy efficiency and energy waste minimization. However, they currently lack easy access to low-cost tools that help interpret the massive amount of data needed to improve understanding of their energy use behaviors. Benchmarking is one of the techniques used in energy audits to identify which buildings are priorities for an energy analysis. Traditional energy performance indicators, such as the energy use intensity (annual energy per unit of floor area), consider only the total annual energy consumption, lacking consideration of the fluctuation of energy use behavior over time, which reveals the time of use information and represents distinct energy use behaviors during different time spans. To fill the gap, this study developed a general statistical method using 24-hour electric load shape benchmarking to compare a building or business/tenant space against peers. Specifically, the study developed new forms of benchmarking metrics and data analysis methods to infer the energy performance of a building based on its load shape. We first performed a data experiment with collected smart meter data using over 2,000 small- and medium-sized businesses in California. We then conducted a cluster analysis of the source data, and determined and interpreted the load shape features and parameters with peer group analysis. Finally, we implemented the load shape benchmarking feature in an open-access web-based toolkit (the Commercial Building Energy Saver) to provide straightforward and practical recommendations to users. The analysis techniques were generic and flexible for future datasets of other building types and in other utility territories.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

National Spherical Torus eXperiment - Upgrade NSTX-U: Structural Analysis of Passive Plates Support Brackets

The objective of this analysis is to estimate and assess the stresses in the passive plates caused by a limiting plasma disruption. The objective of this calculation is also to address observed damage to mounting hardware after completion of NSTX operation. These observations initiated diagnostic efforts during the Upgrade project to monitor the severity of the disruptions that were causing the damage, and planned instrumentation to trend the behavior of the mounting hardware. The Recovery Project mission for the passive plate hardware is to appropriately reinforce the passive plates with stainless steel ribs mounted on the back of the plate to reduce their flexure and stress and reinforcements of the “biscuit” components of the bracketry to transfer loads without damage to bolts, biscuits, and bracket plates and welds. Mid-plane disruptions and quenches were manageable with NSTX vintage hardware. The Vertical Displacement Event (VDE) disruptions position the plasma closer to the passive plates and are more severe than the centered plasma. Earlier work pointed to the P1-P5 VDE as limiting. This has been confirmed by A. Brooks work in support of the load generation effort in reference. During vertical displacement large counter currents are generated in the plate as the plasma approaches it. - as would be expected from passive plates. When the plasma disrupts the currents in the plates are reversed, which also reverses the loading on the plates. This report documents the methodology and results of transient structural analysis on the plasma, passive plates support brackets. The loads induced by eddy and halo currents have been considered, and were generated using a separate electromagnetic analysis (NSTXU_1_11_2_1_CALC_051). The structural model also incorporates the effects from preload. Calculation was performed with the assumption that existing biscuits are not participating in the load bearing except the biscuits connected to jumper bolts, which are fully engaged. Results show that with the planned reinforcements, Passive plates and mounting structures satisfy static and fatigue criteria in all areas except welds, where separate analysis was performed. Both symmetric and asymmetric (with locating block) designs were analyzed, and although stresses were higher without locating block they still satisfy NSTX design criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NREL Works to Increase Electric Vehicle Efficiency Through Enhanced Thermal Management [Fact Sheet]

Researchers at NREL are providing new insight into how heating and cooling systems affect the distance that electric vehicles can travel on a single charge. Electric vehicle range can be reduced by as much as 68% per charge because of climate-control demands. NREL engineers are investigating opportunities to change this dynamic and increase driving range by improving vehicle thermal management. NREL experts are collaborating with automotive industry partners to investigate promising thermal management technologies and strategies, including zone-based cabin temperature controls, advanced heating and air conditioning controls, seat-based climate controls, vehicle thermal preconditioning, and thermal load reduction technologies.

30 DIRECT ENERGY CONVERSION↗

Spent Nuclear Fuel Canister Capacity: Have the Limits Been Reached?

The commercial US nuclear utilities have been transferring spent nuclear fuel (SNF) from spent fuel pools (SFPs) to dry storage systems since 1986. SFPs were initially constructed for temporary storage, but without SNF reprocessing options in the United States and with no final disposal pathway yet available,SFPs started to reach capacity. Hence, to allow continued operation of the nation’s commercial nuclearreactor fleet, utilities started transferring SNF from SFPs (wet storage) to dry storage. Dry storage systems have evolved from storage-only systems first loaded in 1986 to the high-capacity dual-purpose storage and transport canisters used today. A question has arisen as to whether maximum canister capacity has been reached at the current capacity of ~50 kW heat load for storage, with 37-assembly pressurized water reactor and 89-assembly boiling water reactor canisters. This paper presents a holistic overview of commercial US SNF management practices over the years, the current SFP status in terms of filled (occupied) and empty (available) locations, the expected future reactor discharges, and the decay heat load distribution of SFP inventories as of June 2013. Finally, the paper makes a case that further increase in dry storage system capacity both in terms of number of assemblies and decay heat (1) is not needed, and (2) may not be practical from the cost-benefit perspective. b

Banerjee, Kaushik↗

Human and behavioral factors contributing to spine-based neurological cockpit injuries in pilots of high-performance aircraft: recommendations for management and prevention

In high-performance aircraft, the need for total environmental awareness coupled with high-g loading (often with abrupt onset) creates a predilection for cervical spine injury while the pilot is performing routine movements within the cockpit. In this study, the prevalence and severity of cervical spine injury are assessed via a modified cross-sectional survey of pilots of multiple aircraft types (T-38 and F-14, F-16, and F/A-18 fighters). Ninety-five surveys were administered, with 58 full responses. Fifty percent of all pilots reported in-flight or immediate post-flight spine-based pain, and 90% of fighter pilots reported at least one event, most commonly (> 90%) occurring during high-g (> 5 g) turns of the aircraft with the head deviated from the anatomical neutral position. Pre-flight stretching was not associated with a statistically significant reduction in neck pain episodes in this evaluation, whereas a regular weight training program in the F/A-18 group approached a significant reduction (mean = 2.492; p < 0.064). Different cockpit ergonomics may vary the predisposition to cervical injury from airframe to airframe. Several strategies for prevention are possible from both an aircraft design and a preventive medicine standpoint. Countermeasure strategies against spine injury in pilots of high-performance aircraft require additional research, so that future aircraft will not be limited by the human in control.

Case Reports↗

Flying Schedule-Matching Descents to Explore Flight Crews' Perceptions of Their Load and Task Feasibility

Multiple studies have investigated the development and use of ground-based (controller) tools to manage and schedule traffic in future terminal airspace. No studies have investigated the impacts that such tools (and concepts) could have on the flight-deck. To begin to redress the balance, an exploratory study investigated the procedures and actions of ten Boeing-747-400 crews as they flew eight continuous descent approaches in the Los Angeles terminal airspace, with the descents being controlled using speed alone. Although the study was exploratory in nature, four variables were manipulated: speed changes, route constraints, clearance phraseology, and winds. Despite flying the same scenarios with the same events and timing, there was at least a 50 second difference in the time it took crews to fly the approaches. This variation is the product of a number of factors but highlights potential difficulties for scheduling tools that would have to accommodate this amount of natural variation in descent times. The primary focus of this paper is the potential impact of ground scheduling tools on the flight crews performance and procedures. Crews reported "moderate to low" workload, on average; however, short periods of intense and high workload were observed. The non-flying pilot often reported a higher level of workload than the flying-pilot, which may be due to their increased interaction with the Flight Management Computer, when using the aircraft automation to assist with managing the descent clearances. It is concluded that ground-side tools and automation may have a larger impact on the current-day flight-deck than was assumed and that studies investigating this impact should continue in parallel with controller support tool development.

Martin, Lynne Hazel↗

Real-time Simulation Model of a Vanadium Redox Flow Battery Energy Storage System with Power Electronics Integration

This paper presents a real-time (RT) model of a 20 kW multi-stack vanadium redox flow battery (VRFB) system including power electronics converters in a single real-time framework. Implemented on a Typhoon HIL 604 device, this model is designed to simulate the operation of the flow battery with system-level controls. To provide a realistic overview of a VRFB system, the model incorporates a closed-loop control system for managing the speeds of two centrifugal pumps and an electro-thermal model of the battery stacks, enabling realtime temperature estimation. Furthermore, a two-stage power electronics topology and associated control solution are presented, operating with distinct strategies for interfacing the battery model with the main grid and a local load. Results from simulations demonstrate that the VRFB model is well suited for RT environment, and system can manage power during both charging and discharging cycles, while a SCADA monitor is used to display critical variables for safe, efficient, and reliable operation of the VRFB systems.

Rezende Da Costa Reis Kimpara, Renata [ORNL] (ORCI↗

Hydropower representation in water and energy system models: a review of divergences and call for reconciliation

Abstract Reservoir-based hydropower systems represent key interactions between water and energy systems and are being transformed under policy initiatives driven by increasing water and energy demand, the desire to reduce environmental impacts, and interacting effects of climate change. Such policies are often guided by complex system models, whereby divergence in system representations can potentially translate to incompatible planning outcomes, thereby undermining any planning that may rely on them. We review different approaches and assumptions in hydropower representation in water and energy systems. While the models and issues are relevant globally, the review focuses on applications in California given its extensive development of energy and water models for policy planning, but discusses the extent to which these observations apply to other regions. Structurally, both water-driven and energy-driven management models are similar. However, in energy models, hydropower is often represented as a single-priority output. Water management models typically allocate water for competing priorities, which are generally uninformed by dynamic electricity load demand, and often result in a lower priority for hydropower. In water models, constraints are increasingly resolved for non-energy components (e.g. inflow hydrology and non-energy water demand); few analogues exist for energy models. These limitations may result in inadequate representations of each respective sector, and vastly different planning outcomes for the same facilities between the two different sectors. These divergent modeling approaches manifest themselves in California where poorly reconciled outcomes may affect decisions in hydropower licensing, electricity grid flexibility and decarbonization, and planning for environmental water. Fully integrated water-energy models are computationally intensive and specific to certain regions, but better representation of each domain in respective efforts would help reconcile divergences in planning and management efforts related to hydropower across energy and water systems.

Rheinheimer, David E. (ORCID:0000000315259069)↗

Radiative transfer in the electrode region of an arc heater

Radiation from hot gases in the electrode region of an arc heater are discussed. Major original contributions are made: (1) an analytical expression for the radiative heat flux, for an axisymmetric geometry and a grey reflecting wall, is derived, (2) the expression is rendered analytically differentiable/integrable by using appropriate techniques to remove the singularities, and (3), finally a two band model is devised to compute the radiative heat load at the walls in NASA Ames' jet facility. The advantage of using these techniques is that the time taken for the numerical integration is considerably reduced and computation of a 39 x 39 axisymmetric geometry becomes manageable. Fluid equations, representative of a high current arc heater, are numerically solved for an axisymmetric geometry. The computed average heat load of 400 Watts/sq cm using the two band model agrees well with the experimental estimates made at NASA Ames' facility.

Durgapal, P.↗

Hypoxia in the Northern Gulf of Mexico

Since 1985, scientists have been documenting a hypoxic zone in the Gulf of Mexico each year. The hypoxic zone, an area of low dissolved oxygen that cannot support marine life, generally manifests itself in the spring. Since marine species either die or flee the hypoxic zone, the spread of hypoxia reduces the available habitat for marine species, which are important for the ecosystem as well as commercial and recreational fishing in the Gulf. Since 2001, the hypoxic zone has averaged 16,500 km{sup 2} during its peak summer months, an area slightly larger than the state of Connecticut, and ranged from a low of 8,500 km{sup 2} to a high of 22,000 km{sup 2}. To address the hypoxia problem, the Mississippi River/Gulf of Mexico Watershed Nutrient Task Force (or Task Force) was formed to bring together representatives from federal agencies, states, and tribes to consider options for responding to hypoxia. The Task Force asked the White House Office of Science and Technology Policy to conduct a scientific assessment of the causes and consequences of Gulf hypoxia through its Committee on Environment and Natural Resources (CENR). In 2000 the CENR completed An Integrated Assessment: Hypoxia in the Northern Gulf of Mexico (or Integrated Assessment), which formed the scientific basis for the Task Force's Action Plan for Reducing, Mitigating, and Controlling Hypoxia in the Northern Gulf of Mexico (Action Plan, 2001). In its Action Plan, the Task Force pledged to implement ten management actions and to assess progress every 5 years. This reassessment would address the nutrient load reductions achieved, the responses of the hypoxic zone and associated water quality and habitat conditions, and economic and social effects. The Task Force began its reassessment in 2005. In 2006 as part of the reassessment, USEPA's Office of Water, on behalf of the Task Force, requested that the U.S. Environmental Protection Agency (USEPA) Science Advisory Board (SAB) convene an independent panel to evaluate the state-of-the-science regarding hypoxia in the Northern Gulf of Mexico and potential nutrient mitigation and control options in the Mississippi-Atchafalaya River basin (MARB). The Task Force was particularly interested in scientific advances since the Integrated Assessment and posed questions in three areas: characterization of hypoxia; nutrient fate, transport and sources; and the scientific basis for goals and management options. The Hypoxia Study Group began its deliberations in September of 2006 and completed its report in August of 2007 while operating under the 'sunshine' requirements of the Federal Advisory Committee Act, which include providing public access to advisory meetings and opportunities for public comment. This Executive Summary summarizes the Hypoxia Study Group's major findings and recommendations.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of watershed-derived mass loads to prioritize TMDL decision-making

A total maximum daily load (TMDL) for oxygen demanding substances is being implemented in the San Joaquin River (SJR) in California (USA) due to frequently occurring low dissolved oxygen conditions. The SJR is a eutrophic river, heavily impacted by agriculture. A mass balance was developed to identify the sources of oxygen-demanding substances and nutrients to the river with the objective of providing a scientific basis for management actions needed to meet TMDL requirements. Data were collected for flow and water quality and mass loads calculated for sites within the main stem of the SJR, river inputs (tributaries), and diversions in the study area. Using a quadrant analysis, tributary flows and loads are ranked to identify targets for water quality improvement efforts. Additionally, all mass loads were summed (inputs minus diversions) and compared with observed loads at the downstream limit of the study area. The mass balance analysis identifies major contributors of mass loads and mass balance closure is assessed for each constituent. These analysis methods inform the TMDL process which includes a load allocation, and is useful for determining locations for implementation of improvement projects needed to improve the health of the river.

54 ENVIRONMENTAL SCIENCES↗

Impact of Uncertainty from Load-Based Reserves and Renewables on Dispatch Costs and Emissions

Aggregations of controllable loads are considered to be a fast-responding, cost-efficient, and environmental-friendly candidate for power system ancillary services. Unlike conventional service providers, the potential capacity from the aggregation is highly affected by factors like ambient conditions and load usage patterns. Previous work modeled aggregations of controllable loads (such as air conditioners) as thermal batteries, which are capable of providing reserves but with uncertain capacity. A stochastic optimal power flow problem was formulated to manage this uncertainty, as well as uncertainty in renewable generation. In this paper, we explore how the types and levels of uncertainty, generation reserve costs, and controllable load capacity affect the dispatch solution, operational costs, and CO2 emissions. We also compare the results of two methods for solving the stochastic optimization problem, namely the probabilistically robust method and analytical reformulation assuming Gaussian distributions. Case studies are conducted on a modified IEEE 9-bus system with renewables, controllable loads, and congestion. We find that different types and levels of uncertainty have significant impacts on dispatch and emissions. More controllable loads and less conservative solution methodologies lead to lower costs and emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

THREE-DIMENSIONAL THERMAL MODELING ANALYSIS OF CST MEDIA FOR THE SMALL ION EXCHANGE PROJECT

The Small Column Ion Exchange (SCIX) project is designed to accelerate closure of High Level Waste (HLW) tanks at the Savannah River Site (SRS). The SRS tanks store HLW in three forms: sludge, saltcake, and supernate. An in-tank ion exchange process is being designed to treat supernate and dissolved saltcake waste. Through this process, radioactive cesium from the salt solution is adsorbed into Crystalline Silicotitanate (CST) ion exchange media packed within a flow-through column. A packed column loaded with radioactive cesium generates significant heat from radiolytic decay. The waste supernate solution within the ion exchange bed will boil around 120 C. Solution superheating above the boiling point within the column could lead to violent hazardous energy releases. System heating from loaded CST is also of concern in other process modules, such as the waste tank. Due to tank structural integrity concerns, the wall temperature limit for the SRS waste tanks is 100 C. The transfer of cesium-loaded CST to the tank could result in localized hot spots on the tank floor and walls which may exceed this limit. As a result, thermal modeling calculations have been conducted to predict the maximum temperatures achievable both in the column and in the waste tank. As specified in the associated Technical Task Plan, one objective of the present work was to compute temperature distributions within the ion exchange column module under accident scenarios including loss of salt solution flow through the bed and loss of coolant system flow. The column modeling domain and the scope of the calculations in this case were broadened relative to previous two-dimensional calculations to include vertical temperature distributions within the packed bed of ion exchange media as well as the upper column plenum region containing only fluid. The baseline design conditions and in-column modeling domain for the ion-exchange column module are shown in Figure 1. These evaluations assumed the maximum bounding cesium loading considered possible based on current knowledge regarding CST media and the anticipated feed compositions. Since this cesium loading was considerably higher than the nominal loading conditions in SRS waste, cases with lower loading were also evaluated. Modeling parameters were the same as those used previously unless otherwise indicated. The current model does not capture multi-phase cooling mechanisms operative when solution boiling occurs. This feature is conservative in the sense that it does not account for the large cooling effects associated with phase transfer. However, the potential transfer of heat to the plenum region associated with vertical bubble ascension through the column during boiling is also neglected. Thermal modeling calculations were also performed for the entire waste storage tank for the case where loaded and ground CST was transferred to the tank. The modeling domain used for the in-tank calculations is provided in Figure 2. The in-tank domain is based on SRS Tank 41, which is a Type-IIIA tank. Temperature distributions were evaluated for cylindrical, ground CST mounds located on the tank floor. Media grinding is required prior to vitrification processing of the CST in the SRS Defense Waste Processing Facility (DWPF). The location of the heat source region on the tank floor due to the accumulation of CST material was assumed to be just under the grinder. The shape of the CST mound was assumed to be cylindrical. This shape is believed to be most representative of the actual mound shape formed in the tank, given that submersible mixing pumps will be available for media dispersion. Alternative configurations involving other geometrical shapes for the CST mound were evaluated in the previous work. Sensitivity analysis for the in-tank region was performed for different amounts of CST media. As was the case for the in-column model, the in-tank model does not include multi-phase cooling mechanisms operative when solution boiling occurs. The in-column and the in-tank evaluations incorporated recently updated maximum cesium loading levels calculated using the current SCIX feed compositions, which resulted in significantly higher cesium loading than previously calculated. The calculations were conducted to ensure conservative predictions for the maximum temperatures achievable using the current baseline design. The degree of conservatism was reduced for in-column calculations relative to the previous work by using a three-dimensional modeling approach and selecting parameters which were nearer to expected conditions. The degree of conservatism for the in-tank calculations was also reduced by lowering the soil penetration depth below the tank from 150 to 20 feet. The primary goals of the extended thermal modeling effort were to determine whether fluid boiling or superheating are possible within the column module and to determine the maximum floor temperatures within the tank loaded with spent CST.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗