24% Single-Junction GaAs Solar Cell Grown Directly on Growth-Planarized Facets Using Hydride Vapor Phase Epitaxy

A 24%-efficient single-junction GaAs solar cell grown directly on a faceted, spalled (100) GaAs substrate after in situ planarization growth by hydride vapor phase epitaxy (HVPE) is achieved. Controlled spalling, a promising low-cost substrate reuse technique, produces large facets in (100)-oriented GaAs substrates due to the orientation of the fracture planes used for lift-off. Planarization by HVPE offers a path toward direct use of these spalled substrates without costly polishing steps. In this report the growth rate anisotropy enabling planarization arising from diffusion and differences in the adsorption of growth species on {n11}B-type facets relative to (100) is determined. Consecutive planarization and device growth that results in a solar cell with a minimal performance difference relative to a control cell grown on an epitaxy-ready substrate are demonstrated. These results show that controlled spalling coupled with HVPE planarization is a viable pathway for lowering the cost of III-V photovoltaics.

14 SOLAR ENERGY↗

Simulation and partial prototyping of an eight‐junction holographic spectrum‐splitting photovoltaic module

Abstract Spectrum‐splitting photovoltaics incorporate optical elements to separate sunlight into frequency bands, which can be targeted at solar cells with bandgaps optimized for each sub‐band. Here, we present the design of a holographic diffraction grating‐based spectrum‐splitting photovoltaic module integrating eight III‐V compound semiconductor cells as four dual‐junction tandems. Four stacks of simple sinusoidal volume phase holographic diffraction gratings each simultaneously split and concentrate sunlight onto cells with bandgaps spanning the solar spectrum. The high‐efficiency cells get an additional performance boost from concentration incorporated using a single or a compound trough concentrator, providing up to 380X total concentration. Cell bandgap optimization incorporated an experimentally derived bandgap‐dependent external radiative efficiency function. Simulations show 33.2% module conversion efficiency is achievable. One grating stack is experimentally fabricated and characterized.

Darbe, Sunita↗

Printed assemblies of microscale triple–junction inverted metamorphic GaInP/GaAs/InGaAs solar cells

Inverted metamorphic (IMM) multijunction solar cells represent a promising material platform for ultrahigh efficiency photovoltaic systems (UHPVs) with a clear pathway to beyond 50% efficiency. The conventional device processing of IMM solar cells, however, typically involves wafer bonding of a centimeter-scale die and destructive substrate removal, thereby imposing severe restrictions in achievable cell size, type of module substrate, spatial layout, as well as cost effectiveness. Here, we report material design and fabrication strategies for microscale triple-junction IMM (3J IMM) Ga 0.51 In 0.49 P/GaAs/In 0.26 Ga 0.74 As solar cells that can overcome these difficulties. Specialized schemes of delineation and undercut etching enable the defect-free release of microscale IMM solar cells and printed assemblies on a glass substrate in a manner that preserves the growth substrate, where efficiencies of 27.3% and 33.9% are demonstrated at simulated AM1.5D one- and 351 sun illumination, respectively. A composite carrier substrate where released IMM microcells are formed in fully functional, print-ready configurations allows high-throughput transfer printing of individual IMM microcells in a programmable spatial layout on versatile choices of module substrate, all desired for CPV applications.

14 SOLAR ENERGY↗

Comparison of Theoretical Efficiencies of Multi-junction Concentrator Solar Cells

Champion concentrator cell efficiencies have surpassed 40% and now many are asking whether the efficiencies will surpass 50%. Theoretical efficiencies of >60% are described for many approaches, but there is often confusion about the theoretical efficiency for a specific structure. The detailed balance approach to calculating theoretical efficiency gives an upper bound that can be independent of material parameters and device design. Other models predict efficiencies that are closer to those that have been achieved. Changing reference spectra and the choice of concentration further complicate comparison of theoretical efficiencies. This paper provides a side-by-side comparison of theoretical efficiencies of multi-junction solar cells calculated with the detailed balance approach and a common one-dimensional-transport model for different spectral and irradiance conditions. Also, historical experimental champion efficiencies are compared with the theoretical efficiencies.

14 SOLAR ENERGY↗

A Model of Competing Orders and Its Application to a Novel Junction

We introduce a simple Ginzburg-Landau model to describe coupled orders, such as antiferromagnetism and superconductivity in high-T{sub c} cuprate superconductors, using which we can study the spatial modulation of the doping rate. We study junctions between non-doped and highly doped materials of cuprates. Possibility of a novel superconducting boundary state is suggested, which appears at temperatures higher than the maximum transition temperature of the bulk material at optimal doping. Experimental possibilities to realize this state is also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Josephson Junctions and Cosmic Microwave Background

The implementation of utilizing superconducting quantum interference device (SQUID) readout for constant voltage biased transition edge sensors (TES) has enabled the detection of the infinitesimal fluctuation in cosmic microwave background (CMB). The properties of the fluctuations will provide us the information of the universe at the time that this light was first emitted. In short, by measuring the CMB today, we learn about the distant, ancient universe—how the universe began, what it is made of, and how it evolved to its current state. Over the past 20 years, we have achieved many successful CMB measurements with Josephson junctions. Brian, I extend my congratulations on your eight decades of life—Happy 80th birthday!

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Slip localization behavior at triple junctions in nickel-base superalloys

Incipient slip localization in the vicinity of hundreds of grain boundary triple junctions (TJs) in a lightly deformed nickel-base superalloy IN718 is studied using a combination of three-dimensional (3D) crystal plasticity finite element (CPFE) modeling, high resolution digital image correlation (HR-DIC) and 3D electron back-scatter diffraction tomography (3D EBSD). A 3D reconstruction method enables identification of thousands of TJs and correspondence of any observed slip bands with their originating TJ lines below the specimen surface. Here, we present a large-scale CPFE model of the experimental 3D microstructure composed of high-fidelity representation of the TJ lines and the boundaries and interiors of the parent grains and use it to calculate the local micromechanical response and slip activity of all TJs at the onset of macroscopic yielding. Statistical analysis of the calculated quantities reveal TJs develop larger stress concentration and grain-average re-orientation than grain interiors and grain boundaries, however no substantial differences in cumulative slip were found among these microstructural regions. We find that TJs with observed slip bands generate lower grain-average re-orientation, fewer active slip systems, and more localized slip on a single system than those without. The distinctions in the reorientation and slip activity are stronger in TJs that experience more intense slip.

36 MATERIALS SCIENCE↗

Regulation of tight junction permeability by sodium caprate in human keratinocytes and reconstructed epidermis

Tight junctions (TJs) restrict paracellular flux of water and solutes in epithelia and endothelia. In epidermis, the physiological role of TJs is not fully understood. In this study, sodium caprate (C10), which dilates intestinal TJs, was applied to cultured human epidermal keratinocytes and reconstructed human epidermis to investigate the effects of C10 on epidermal TJs. C10 treatment decreased transepithelial electrical resistance and increased paracellular permeability, although Western blots showed that the expression of TJ-related transmembrane proteins was not decreased. The effects of C10 were reversible. Immunofluorescence microscopy and immuno-replica electron microscopy showed that the localization of TJ strands were disintegrated, concomitant with the dispersion and/or disappearance of TJ-related molecules from the cell surface. These findings suggest that C10 impairs barrier function by physically disrupting TJ conformation in the epidermis. Furthermore, these results also show that proper localization of the molecules on the cellular membrane is important for TJ barrier function.

60 APPLIED LIFE SCIENCES↗

Adherens junction-associated pores mediate the intercellular transport of endosomes and cytoplasmic proteins

Highlights: • We demonstrated the presence of AJ-associated pores with MTs traversing through the pores. • Live imaging allows direct visualization of vesicles being transported through the AJ-associated pores. • The dimerized vesicle-kinesin complexes move across AJs into the neighboring cell. • Most epidermal cells form dorsoventral-oriented two-cell syncytia. Intercellular endosomes (IEs) are endocytosed vesicles shuttled through the adherens junctions (AJs) between two neighboring epidermal cells during Drosophila dorsal closure. The cell-to-cell transport of IEs requires DE-cadherin (DE-cad), microtubules (MTs) and kinesin. However, the mechanisms by which IEs can be transported through the AJs are unknown. Here, we demonstrate the presence of AJ-associated pores with MTs traversing through the pores. Live imaging allows direct visualization of IEs being transported through the AJ-associated pores. By using an optogenetic dimerization system, we observe that the dimerized IE-kinesin complexes move across AJs into the neighboring cell. The AJ-associated pores also allow intercellular movement of soluble proteins. Importantly, most epidermal cells form dorsoventral-oriented two-cell syncytia. Together, we present a model in which an AJ-associated pore mediates the intercellular transport of IEs and proteins between two cells in direct contact.

60 APPLIED LIFE SCIENCES↗

Spatial influence of paramagnetic molecules on magnetic tunnel junction-based molecular spintronic devices (MTJMSD)

Magnetic Tunnel Junction-Based Molecular Spintronic Devices (MTJMSDs) are potential candidates for inventing highly correlated systems. Understanding MTJMSD's magnetic behavior is essential to designing and fabricating practical devices. This paper investigates the effect of two contributing factors on MTJMSD's magnetic properties via Monte Carlo Simulation. Here, we have systematically studied coupling strengths and nature between magnetic molecules and ferromagnetic electrodes at various temperatures. We have also investigated the effect of length and thickness increase on MTJMSD temporal and spatial evolution of magnetic moment, magnetic correlation, and magnetic susceptibility. Our results showed that thermal energy increase significantly affects molecular devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Adenocarcinoma of the Esophagogastric Junction: The Pattern of Metastatic Lymph Node Dissemination as a Rationale for Elective Lymphatic Target Volume Definition

Purpose: Regional nodal metastasis after neoadjuvant chemoradiation of adenocarcinoma of the esophagogastric junction (AEG) predicts survival. We aimed to clarify the lymph node (LN) distribution of AEG according to location of the tumor mass and invasion of neighboring areas for the selection of radiotherapy planning target volume (PTV) margins. Methods and Materials: Patterns of regional spread were analyzed in pathology reports of 326 patients patients with AEG who had undergone primary resection, with {>=}15 lymph nodes examined. Tumors were classified into AEG types based on endoscopy and pathology reports. Fisher's exact test was used to compare nodal disease and tumor characteristics. Pulmonary dose-volume histograms were tested in 8 patients. Results: Nodes were positive in 81% of T2 to T4 tumors. Type of AEG, tumor size, lymphovascular invasion, and grading significantly influenced nodal distribution. We found that marked esophageal invasion of AEG II/III significantly correlated with paraesophageal nodal disease, and T3 to T4 AEG II/III had a significant rate of splenic hilum/artery nodes. Middle and lower paraesophageal nodes should be treated in T2 to T4 AEG I and AEG II with {>=}15 mm involvement above the Z-line, and T3 to T4 AEG II. The splenic hilum and artery nodes can be spared in T2 AEG tumors, especially Type I tumors. The influence of paraesophageal nodal treatment on the risk of postoperative pulmonary complications can be estimated from dose-volume histograms. Conclusions: Accurate pretherapeutic staging predicts the risk of subclinical nodal disease and should be used to select the appropriate radiotherapeutic PTV. Careful selection of the PTV can be used to maximize the therapeutic window in multimodal therapy for AEG.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase II Trial of Preoperative Irinotecan-Cisplatin Followed by Concurrent Irinotecan-Cisplatin and Radiotherapy for Resectable Locally Advanced Gastric and Esophagogastric Junction Adenocarcinoma

Purpose: To determine in a Phase II trial whether preoperative irinotecan-cisplatin (IC) followed by concurrent IC therapy and radiotherapy (IC/RT) improved outcome in patients with resectable, locally advanced gastric adenocarcinoma (GC) or esophagogastric junction cancer (EGJC). Patients and Methods: Patients with resectable Stage II-IV, M0 GC or EGJC made up the study population. The primary endpoint was pathologic complete response (pCR). Two courses of IC (irinotecan, 65mg/m{sup 2}; cisplatin, 30mg/m{sup 2} on Days 1 and 8 every 21 days) were given. Patients without progression then received IC/RT, consisting of daily radiotherapy (45Gy) with concurrent IC (irinotecan, 65mg/m{sup 2}; cisplatin, 30mg/m{sup 2} on Days 1, 8, 15, and 22). Surgical resection was performed, if feasible, 5-8 weeks after the end of radiotherapy. Results: Twenty-three patients were included in the study: 10 with EGJC and 13 with GC. Two patients (9%) achieved pCR. The incidences of Grade 3-4 toxicities were as follows: IC: neutropenia 35% (febrile 13%), anemia 22%, diarrhea 22%, emesis 8%; IC/RT: neutropenia 52% (febrile 5%), asthenia 19%, anemia 9%, emesis 9%, diarrhea 5%, cardiotoxicity 5%. No patients died during IC or IC/RT. R0 resection was achieved in 15 patients (65%). Median survival was 14.5 months, and the actuarial 2-year survival rate was 35%. Conclusions: Preoperative IC followed by IC/RT resulted in moderate response and resection rates with mild toxicity in patients with GC and EGJC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Gastric Filling on Radiation Dose Delivered to Gastroesophageal Junction Tumors

Purpose: This study examined the impact of gastric filling variation on target coverage of gastroesophageal junction (GEJ) tumors in three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), or IMRT with simultaneous integrated boost (IMRT-SIB) plans. Materials and Methods: Eight patients previously receiving radiation therapy for esophageal cancer had computed tomography (CT) datasets acquired with full stomach (FS) and empty stomach (ES). We generated treatment plans for 3DCRT, IMRT, or IMRT-SIB for each patient on the ES-CT and on the FS-CT datasets. The 3DCRT and IMRT plans were planned to 50.4 Gy to the clinical target volume (CTV), and the same for IMRT-SIB plus 63.0 Gy to the gross tumor volume (GTV). Target coverage was evaluated using dose-volume histogram data for patient treatments simulated with ES-CT sets, assuming treatment on an FS for the entire course, and vice versa. Results: FS volumes were a mean of 3.3 (range, 1.7-7.5) times greater than ES volumes. The volume of the GTV receiving >=50.4 Gy (V{sub 50.4Gy}) was 100% in all situations. The planning GTV V{sub 63Gy} became suboptimal when gastric filling varied, regardless of whether simulation was done on the ES-CT or the FS-CT set. Conclusions: Stomach filling has a negligible impact on prescribed dose delivered to the GEJ GTV, using either 3DCRT or IMRT planning. Thus, local relapses are not likely to be related to variations in gastric filling. Dose escalation for GEJ tumors with IMRT-SIB may require gastric filling monitoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the Interfractional Displacement of the Gastroesophageal Junction During Radiation Therapy for Esophageal Cancer

Purpose: Accounting for interfractional changes in tumor location improves the accuracy of radiation treatment delivery. The purpose of this study was to quantify the interfractional displacement of the gastroesophageal junction (GEJ) based on standard treatment setup in patients with esophageal cancer undergoing radiation therapy. Methods and Materials: Free-breathing four-dimensional computed tomography (4D-CT) datasets were acquired weekly from 22 patients during treatment for esophageal adenocarcinoma. Scans were registered to baseline (simulation) 4D-CT scans by using bony landmarks. The distance between the center of the GEJ contour on the simulation scan and the mean location of GEJ centers on subsequent scans was used to assess changes in GEJ location between fractions; displacement was also correlated with clinical and respiratory variables. Results: The mean absolute random error was 1.69 mm (range, 0.11-4.11 mm) in the lateral direction, 1.87 mm (range, 0.51-4.09 mm) in the anterior-posterior (AP) direction, and 3.09 mm (range, 0.99-6.16 mm) in the superior-inferior (SI) direction. The mean absolute systemic GEJ displacement between fractions was 2.88 mm lateral ({>=}5 mm in 14%), mostly leftward; 2.90 mm ({>=}5 mm in 14%) AP, mostly anterior; and 6.77 mm ({>=}1 cm in 18%) SI, mostly inferior. Variations in tidal volume and diaphragmatic excursion during treatment correlated strongly with systematic SI GEJ displacement (r = 0.964, p < 0.0001; and r = 0.944, p < 0.0001, respectively) and moderately with systematic AP GEJ displacement (r = 0.678, p = 0.0005; r = 0.758, p < 0.0001, respectively). Systematic displacement in the inferior direction resulted in higher-than-intended doses ({>=}60 Gy) to the GEJ, with increased hot-spot to the adjacent stomach and lung base. Conclusion: We found large (>1-cm) interfractional displacements in the GEJ in the SI (especially inferior) direction that was not accounted for when skeletal alignment alone was used for patient positioning. Because systematic displacement in the SI direction had dosimetric impact and correlated with tidal volume, better accounting for depth of breathing is needed to reduce interfractional variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Expert Consensus Contouring Guidelines for Intensity Modulated Radiation Therapy in Esophageal and Gastroesophageal Junction Cancer

Purpose/Objective(s): Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Methods and Materials: Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophageal cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. Results: The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. Conclusions: This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Executive Summary of the American Radium Society Appropriate Use Criteria for Operable Esophageal and Gastroesophageal Junction Adenocarcinoma: Systematic Review and Guidelines

Limited guidance exists regarding the relative effectiveness of treatment options for nonmetastatic, operable patients with adenocarcinoma of the esophagus or gastroesophageal junction (GEJ). In this systematic review, the American Radium Society (ARS) gastrointestinal expert panel convened to develop Appropriate Use Criteria (AUC) evaluating how neoadjuvant and/or adjuvant treatment regimens compared with each other, surgery alone, or definitive chemoradiation in terms of response to therapy, quality of life, and oncologic outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Clinical Efficacy of Neoadjuvant Chemoradiation Therapy Between Lower and Higher Radiation Doses for Carcinoma of the Esophagus and Gastroesophageal Junction: A Systematic Review

Neoadjuvant concurrent chemoradiation therapy (nCRT) plus surgery has been a standard treatment for locoregionally advanced esophageal cancer and carcinoma of the gastroesophageal junction (EC/GEJ), but the optimal preoperative radiation dose is still unclear. We performed this systematic review to explore the treatment efficacy and toxicity of different radiation dose levels and find an optimal dose‐fractionation strategy in EC/GEJ patients receiving nCRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gap junctions fine-tune ganglion cell signals to equalize response kinetics within a given electrically coupled array

Retinal ganglion cells (RGCs) summate inputs and forward a spike train code to the brain in the form of either maintained spiking (sustained) or a quickly decaying brief spike burst (transient). We report diverse response transience values across the RGC population and, contrary to the conventional transient/sustained scheme, responses with intermediary characteristics are the most abundant. Pharmacological tests showed that besides GABAergic inhibition, gap junction (GJ)–mediated excitation also plays a pivotal role in shaping response transience and thus visual coding. More precisely GJs connecting RGCs to nearby amacrine and RGCs play a defining role in the process. These GJs equalize kinetic features, including the response transience of transient OFF alpha (tOFFα) RGCs across a coupled array. We propose that GJs in other coupled neuron ensembles in the brain are also critical in the harmonization of response kinetics to enhance the population code and suit a corresponding task.