Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Size Up or Size Down? National Analysis of Heat Pump Sizing and Impacts

Electrification of on-site fossil fuel combustion in buildings is recognized as a key component of achieving global greenhouse gas emissions targets. Air-source heat pumps are an efficient approach for space heating electrification. However, a major barrier to heat pump adoption is the high installation cost relative to furnaces and air conditioners. Because the installation cost of heat pumps - especially cold climate models - is dependent on their size, it is important to understand the distribution of heat pump sizes using different sizing methods and factors that impact heat pump sizing. In this study, we use sub-hourly physics simulations of 550,000 statistically representative dwelling units to analyze the distribution of heat pump size in the U.S. for three different efficiency levels of heat pumps, with and without building insulation and air sealing upgrades. We will present results from the national analysis of different factors affecting heat pump sizing along with the impact of sizing decisions on upgrade costs and operating costs.

electrification↗

Solar Photovoltaic and Storage Supply Chains and Technology and Market Opportunities

This talk will highlight the most recent efforts from the National Renewable Energy Laboratory (NREL) to track solar photovoltaic (PV) and storage supply and demand in the United States and globally, as well as bottom-up calculations of manufacturing costs for facilities across the globe. We will begin with an overview of the global solar PV supply chain and 2022 benchmark input data used for NREL's bottom-up crystalline silicon (c-Si) and thin film PV module manufacturing cost models. For the polysilicon, wafer, cell conversion, and module assembly steps of the c-Si supply chain, and for thin film modules, we will review the industry-collected input data and methods used for calculating the costs of goods sold (COGS); research and development (R&D) expenses; and sales, general, and business administration (S, G, and A) expenses. This 2022 benchmark analysis is compiled for state-of-the-art c-Si and thin film PV module manufacturing in several countries and regions; and will also include a quantified summary of the impacts of the manufacturing incentives and tax credits that are available for solar manufacturing and installations within the United States. Next generation technologies that lower PV manufacturing and installation costs, reduce operations and maintenance (O&M) expenses, and improve system energy yield will also be highlighted. We will conclude with projections of solar market penetration to 2050 from NREL's Solar Futures Study and Annual Technology Baseline (ATB) model, which includes solar coupled with lower-cost storage scenarios as well as the range of future cost scenarios for other power generation sources. We look forward to sharing NREL's extensive work in these areas and discussing ideas for future directions.

economics↗

SERPENT 2 and TRIPOLI-4 neutronics benchmarking of the Jules Horowitz reactor

Jules Horowitz Reactor (JHR) is a future center for nuclear material testing in Europe, currently under construction at CEA Cadarache in southern France. It has been modelled extensively with CEA's HORUS3D/N neutron calculation package, that includes a Monte-Carlo neutron transport code TRIPOLI-4. In order to support the future computational analyses on the reactor core physics, VTT's Monte Carlo neutronics code SERPENT 2 has been used to create an alternative model of the JHR, taking advantage of the pre-existing Constructive Solid Geometry (CSG) structures on which the TRIPOLI-4 model was built. This work describes a benchmark, in which two JHR core configurations were analyzed using both of these models. The first configuration is a fresh fuel core at the beginning of life, in which aluminum based dummy-devices are installed in the reactor test positions. The second configuration represents the end-of-cycle equilibrium core with a heterogeneous burnup distribution, in which CALIPSO devices containing cladding material samples are installed at the in-core experimental positions, while the reflector positions are occupied by DEN-REP devices containing UO{sub 2} fuel. Neutron flux spectra and heat deposition are the parameters of interest in this study, due to their high importance in creating the desired experimental irradiation environment. The impact of delayed gamma energy deposition will be studied in detail, since the two models account for it with different methods. This work aims to establish a SERPENT 2 model of JHR, understanding its differences and agreements with TRIPOLI-4, and discussing its potential future applications. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Energy and Carbon Payback Times for Modern U.S. Utility Photovoltaic Systems

Manufacturing and operating a PV system consumes non-renewable energy and produces carbon emissions, as does end-of-life handling when PV systems are eventually decommissioned. To fully account for PV's contribution toward decarbonization, these life cycle impacts must be quantified. A 2023 NREL LCA of utility PV systems in the United States Study show energy payback times between 0.5 and 1.2 years and carbon payback times between 0.8 to 20 years, depending on the system install location. Payback times are affected by the amount of local solar radiation, and carbon payback time is significantly affected by the carbon-intensity of the local grid it offsets, as well as the future projected grid mix for the location it is installed. In an average U.S. location, carbon payback times are less than 2 years.

carbon payback time↗

Progress towards the completion of the proton power upgrade project

The Proton Power Upgrade project at the Spallation Neutron Source at Oak Ridge National Laboratory will increase the proton beam power capability from 1.4 to 2.8 MW. Upon completion in early 2025, 2 MW of beam power will be available for neutron production at the existing first target station (FTS) with the remaining beam power available for the future second target station (STS). The project has installed seven superconducting radio-frequency (RF) cryomodules and supporting RF power systems to increase the beam energy by 30% to 1.3 GeV, and the beam current will be increased by 50%. The injection and extraction region of the accumulator ring are being upgraded, and a new 2 MW mercury target has been developed along with supporting equipment for high-flow gas injection to mitigate cavitation and fatigue stress. The first four cryomodules and supporting systems were commissioned in 2022-2023 and supported neutron production at 1.05 GeV, 1.7 MW with high reliability. The first-article 2 MW target was operated successfully for approximately 4400 MW-Hours over two run periods. The long outage began in August 2023 for installation of the remaining technical equipment and construction of the Ring-to-Target Beam Transport tunnel stub that will enable connection to the STS without interrupting operation of the FTS. The upgrade is proceeding on-schedule and on-budget, and resumption of neutron production for the user program is planned for July 2024.

Champion, Mark↗

SULI Internship Deliverables (Flow Orifice Design: Measuring Degas Flow of Experiment Loops at the Advanced Test Reactor)

These deliverables present a design for a new orifice flow meter to be installed in three experiment loops at the Advanced Test Reactor. The current configuration of the experiment loop system has an orifice that is not properly sized to the low flow rates of the degas line of the pressurizer system, causing inaccurate flow measurements. Under consideration of flow conditions and system constraints, an iterative procedure was utilized to determine the optimal sizing for a new orifice. This orifice is designed to accurately and precisely measure the flow rate of the degas line, which will consequently improve control of the pressure and chemistry of the loop pressurizer system. The scope of this project includes recommendations for orifice sizing, material, flange type, face type, and installation location on the loop piping spools. The design is suitable for experiment loops 1D-N, 2B-SE, and 2D-SW and meets all necessary standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Resilience of Residential Building with Thermally Anisotropic Building Envelope Connected to Geothermal Sources

Heat waves and cold snaps have become more frequent and more intense because of climate change. A heat wave and a cold snap are a period of excessively hot and cold weather, respectively, that poses severe risks to building occupants’ health, especially for vulnerable people. They increase electrical energy consumption and put high stress on the grid which leads to potential power outages. Therefore, it is critical to assess and actively improve the thermal resilience of buildings to cope with heat waves, cold snaps, and power outages. The thermally anisotropic building envelope (TABE) is a novel active building envelope that can save energy while maintaining thermal comfort in buildings by redirecting heat and coolness from building envelopes to hydronic loops. When connecting to a ground thermal loop (GL), TABE can utilize the relatively stable temperature of the ground to protect the indoor environment during heat waves and cold snaps. This study assesses the thermal resilience of residential buildings that installed TABE and used ground thermal energy to supply the hydronic loops, abbreviated as ground thermal loop or TABE+GL. The simulation and analysis are conducted for the US Department of Energy prototype single-family detached residential building in the hot climate of Miami, Florida and Tucson, Arizona, and the cold climate of Denver, Colorado, and Rochester, Minnesota. Heat waves and cold snaps were obtained from the historical weather data of 1998-2020 for the studied regions. Three thermal resilience metrics, including the standard effective temperature (SET) degree-hours, the Heat Index, and the Hours of Safety (HOS) were used to quantify the effect of TABE+GL. The results showed that buildings installed TABE+GL could significantly reduce the average SET degree-hours above 30°C, increase HOS, and greatly improve thermal resilience.

Shen, Zhenglai↗

AMTS update for STTR

Advanced nuclear reactor systems currently in development include designs that utilize higher energy neutron spectrums, higher temperatures, and corrosive environments that are quite different from the current fleet of nuclear power plants in use today. As a result, new structural materials must be developed and qualified for use to support these advanced systems. For example, research is currently being conducted on a new class of materials known as multi-principle-element-alloys. These alloys show some promise to be able to meet the structural needs of these challenging reactor systems. However, due to the vast available compositional space, and the limited amount of research conducted thus far, Idaho National Laboratory (INL)sought a way to advanced mechanical testing capability for highly irradiated structural materials to increase both throughput and higher fidelity data analysis through incorporation of digital image correlation. The Automated Mechanical Testing System accomplishes these tasks by automating the testing and incorporating digital image correlation to provide higher fidelity data. INL has now received this system and is currently performing functional testing and training. INL is also performing some modifications to the system to allow for installation into a remote shielded enclosure where testing of irradiated structural materials can be performed. After testing, training, and modifications of the system are complete, INL will install the system into a shielded enclosure and begin using the system to test irradiated structural materials.

36 MATERIALS SCIENCE↗

AquaPV: Regulatory and Environmental Considerations for Floating Photovoltaic Projects Located on Federally Controlled Reservoirs in the United States

To meet the nation's decarbonization goals, the U.S. Department of Energy's Solar Futures study forecasts that installed solar photovoltaic (PV) capacity must increase nearly tenfold, from 80 gigawatts (GW) in 2020 to approximately 760 GW cumulative installed capacity by 2035. Ground-mounted PV is expected to dominate future solar deployment and will require more than 3.5 million acres of land to meet annual demand projections (of nearly 45 GW) by 2030. However, various competing demands for land (e.g., agricultural production, conservation) and high land acquisition costs in specific locations could be challenges to meeting future PV demand solely with ground-mounted PV deployment. Floating photovoltaics (FPV) may be an alternative in locations where ground-mounted PV is not feasible and aid in reaching the nation's PV deployment and decarbonization goals. FPV is a newer siting approach in which a PV array is affixed to a floating apparatus and sited on a water body like a reservoir behind a dam. FPV systems may be stand-alone or co-located at new or existing hydroelectric facilities or pumped storage hydropower (PSH) facility reservoirs. Co-located FPV systems may or may not be operationally paired and work in tandem with the hydroelectric or PSH facility. This report provides novel analysis to understand the opportunities and challenges associated with developing stand-alone and co-located FPV projects on reservoirs in the United States. Specifically, the report explores potential environmental and energy benefits and environmental impacts associated with the siting, construction, and operation of FPV projects. The report also identifies and analyzes U.S. federal- and state-issued permits and authorizations required by federal laws to understand the licensing pathways and regulatory requirements for FPV projects sited on reservoirs licensed by the Federal Energy Regulatory Commission and on powered and non-powered reservoirs owned by the Bureau of Reclamation or U.S. Army Corps of Engineers.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

The Hard Life of Floatovoltaics: Modeling Wind-Driven Oscillations of Floating Solar Panels

Modern, thin photovoltaic (PV) panels for solar power are susceptible to high stress loads in windy conditions. Manufacturers are eager to determine optimal installation practices to reduce these loads, including in the relatively new practice of installing PV on floating structures located on artificial and natural lakes. As part of our effort to develop simulation capabilities for stress on such floating PV systems, we here present our combined model-simulation approach, which simulates the dynamic wind loading and uses modeled elements to capture both the hydrodynamic and mooring-line forces. We discuss the forces important for our model and the challenges inherent in our simulation. Of particular interest is our model of the hysteresis response displayed by the attached mooring lines, which are engineered to damp motion and oscillation of the floating panel system. We validate our approach against the benchmark problem of vortex-induced vibration of a cylinder, which is driven by the same dynamic forces present in floating PV panels.

floating↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100% Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

blackstart with fuel cells↗

Beam Loss Assessment Through Use of Photomultiplier Tubes

Modern accelerators aim to deliver maximal beam current at stable energy with minimal beam loss. Environmental changes, among other factors, can result in increased beam loss and decreased beam throughput, prompting daily retuning of the accelerator. The compact nature of the oldest part of the linear accelerator limits the available beam instrumentation, making beam loss assessment and tuning difficult. Thus, additional devices for beam loss monitoring must be considered. Photomultiplier tube-based beam loss monitors (BLMs) were installed along the Fermilab drift tube Linac to assess beam loss. Due to noise, the data from the installed photomultiplier tubes was difficult to assess. After noise reduction and signal analysis, it was found that the signals produced by the photomultiplier tubes in response to beam loss were consistent for a given configuration and therefore a reasonable measure of beam loss. This project lays groundwork for future work in beam loss assessment using photomultiplier tubes, with the automation of the process developed in this project being the next step in this effort.

Waggoner, Alexander↗

AquaPV: Regulatory and Environmental Considerations for Floating Photovoltaic Projects Located on Federally Controlled Reservoirs in the United States

To meet the nation's decarbonization goals, the U.S. Department of Energy's Solar Futures study forecasts that installed solar photovoltaic (PV) capacity must increase nearly tenfold, from 80 gigawatts (GW) in 2020 to approximately 760 GW cumulative installed capacity by 2035. Ground-mounted PV is expected to dominate future solar deployment and will require more than 3.5 million acres of land to meet annual demand projections (of nearly 45 GW) by 2030. However, various competing demands for land (e.g., agricultural production, conservation) and high land acquisition costs in specific locations could be challenges to meeting future PV demand solely with ground-mounted PV deployment. Floating photovoltaics (FPV) may be an alternative in locations where ground-mounted PV is not feasible and aid in reaching the nation's PV deployment and decarbonization goals. FPV is a newer siting approach in which a PV array is affixed to a floating apparatus and sited on a water body like a reservoir behind a dam. FPV systems may be stand-alone or co-located at new or existing hydroelectric facilities or pumped storage hydropower (PSH) facility reservoirs. Co-located FPV systems may or may not be operationally paired and work in tandem with the hydroelectric or PSH facility. This report provides novel analysis to understand the opportunities and challenges associated with developing stand-alone and co-located FPV projects on reservoirs in the United States. Specifically, the report explores potential environmental and energy benefits and environmental impacts associated with the siting, construction, and operation of FPV projects. The report also identifies and analyzes U.S. federal- and state-issued permits and authorizations required by federal laws to understand the licensing pathways and regulatory requirements for FPV projects sited on reservoirs licensed by the Federal Energy Regulatory Commission and on powered and non-powered reservoirs owned by the Bureau of Reclamation or U.S. Army Corps of Engineers.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Catching Rays: How Bifacial_Radiance Sheds Light on the Future of Solar PV

The challenge of energy transition is immediate and immense, with current projections targeting 75 TW of photovoltaics (PV) capacity globally by 2050. Alongside the rapid deployment is the "solar-coaster" ride the PV industry experiences with evolving technologies and novel installation methods. In 2016, NREL developed bifacial_radiance, a python open-source modeling tool for bifacial PV. This tool is a wrapper of the raytracing engine Radiance, which you all know better than us at this workshop. Bifacial_radiance integrates the many characteristics of common PV systems to model irradiance on both the front and rear sides of bifacial PV technology - a technology that now represents 75% of utility-scale deployment in the US. Bifacial_radiance has been pivotal for understanding bifacial system performance, shading, and edge effects, and now agrivoltaics research. It has also helped develop simplified models used in PV due diligence tools for optimizing new deployments or evaluating the performance of existing projects. Now, it's the go-to comparison tool for many university, and industry-developed systems modeling tools, and a pivotal tool for further research in photovoltaics. This talk will cover the needs bifacial_radiance addresses as an open-source tool, its development path, and the opportunity for any raytracer to shine light on the solar industry through research and practical application of modeling in regular site installations and novel setups like agrivoltaics and vertical panels at high latitudes (and even the South Pole!).

agrivoltaics↗

ICARUS cosmic ray tagger efficiency

The ICARUS Cosmic Ray Tagger (CRT) was constructed with the goal to tag cosmogenic muons passing through the ICARUS Time Projection Chamber (TPC). Construction and commissioning of the detector began in Fall 2019 with the Side CRT North wall and continued for several years through the installation of the Top CRT. In this thesis I will summarize my contributions to the CRT system and describe a measurement of the installed CRT detection efficiency using the TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo: Preprint

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. Using GHEDesigner, a lookup table was created to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on agent energy bills. This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of different costing and pricing future scenarios. While the code is still under development and nationwide simulations are ongoing, initial results for two states are provided. Future work includes expanding the module to consider mixed residential and commercial districts and considering multiple costing scenarios.

ambient temperature loop↗

Design and optimization of higher order mode couplers for the superconducting cavities of the PERLE energy recovery linac

The Powerful Energy Recovery Linac for Experiments (PERLE) is an energy recovery linac (ERL) facility based on superconducting radio-frequency (SRF) technology to be hosted at the Laboratoire de Physique des 2 Infinis Irène Joliot-Curie (IJCLab) in France. With a target beam power of 10 MW, PERLE aims to demonstrate the high-current, continuous wave, multi-pass operation to validate options for future high-energy machines, such as the 50 GeV ERL proposed for the Large Hadron electron Collider (LHeC) and the Future Circular electron-hadron Collider (FCC-eh), and host dedicated particle physics and nuclear experiments. In high-current ERLs, the regenerative Beam Breakup (BBU), emerging from the beam and cavity Higher Order Modes (HOMs) interaction, is a major concern for their stable operation. Beam-induced HOMs can increase the cavity heat load at cryogenic temperature and cause beam instabilities. HOM couplers are installed in the cavity beam pipes to absorb HOM energy and mitigate these effects. This thesis presents the design and optimization of several coaxial HOM couplers for the 5-cell 801.58 MHz elliptical Nb cavities of the 500 MeV PERLE ERL configuration. The RF transmission of the HOM couplers was optimized to enhance the damping of the most dangerous HOMs. The optimized HOM couplers were integrated into endgroups to simulate their damping performance and thermal behavior. The optimized HOM couplers were 3D-printed in epoxy and copper-coated. Low-power RF measurements were conducted on the produced HOM couplers installed in copper PERLE-type cavities to validate their damping performance and propose several endgroups for the PERLE 5-cell cavity to mitigate HOMs below the BBU instability limits.

Barbagallo, Carmelo↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.

ambient-temperature loop↗