Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Toward ultrafast, ultra-stable imaging arrays: Superlattice doping to enhance the performance of backside-illuminated 3D-hybridized silicon photodetectors

In this paper, the authors report the latest results on their development of superlattice-doped, thinned, backside-illuminated (BSI), 3D-integrated photodiode detectors—a step toward their ultimate goal of demonstrating ultrafast, ultrastable CMOS imaging arrays. As with most silicon-based photodetectors, backside-illumination and backside surface passivation are keys to achieve the highest performance capability. The two-dimensional (2D) doping technique developed at the Jet Propulsion Laboratory (JPL) has proved to result in a highly efficient, highly stable detector response when combined with a variety of detectors. Here, JPL's 2D-doping has been combined with Sandia's BSI photodetectors hybridized with custom fanout wafer via copper Direct Bond Interconnect (DBI®), a technology that is rapidly becoming industry standard for BSI CMOS imaging arrays. The prototype detectors were packaged and evaluated with respect to their response to low energy electrons. The authors find that the responsivity of 2D-doped BSI detectors is higher than devices prepared using other surface passivation techniques (i.e., ion implantation). The success of the work described herein verifies that the 2D-doping processes previously developed for Sandia's frontside-illuminated photodetectors are generally applicable to BSI detectors and demonstrates for the first time that JPL's 2D-doping process is compatible with the Cu-DBI® technology.

Jewell, April D.↗

Examining the Angular Resolution of the Astro-H's Soft X-Ray Telescopes

The international x-ray observatory ASTRO-H was renamed Hitomi after launch. It covers a wide energy range from a few hundred eV to 600 keV. It is equipped with two soft x-ray telescopes (SXTs: SXT-I and SXT-S) for imaging the soft x-ray sky up to 12 keV, which focus an image onto the respective focal-plane detectors: CCD camera (SXI) and a calorimeter (SXS). The SXTs are fabricated in a quadrant unit. The angular resolution in half-power diameter (HPD) of each quadrant of the SXTs ranges between 1.1 and 1.4 arc min at 4.51 keV. It was also found that one quadrant has an energy dependence on the HPD. We examine the angular resolution with spot scan measurements. In order to understand the cause of imaging capability deterioration and to reflect it to the future telescope development, we carried out spot scan measurements, in which we illuminate all over the aperture of each quadrant with a square beam 8 mm on a side. Based on the scan results, we made maps of image blurring and a focus position. The former and the latter reflect figure error and positioning error, respectively, of the foils that are within the incident 8 mm x 8 mm beam. As a result, we estimated those errors in a quadrant to be approx. 0.9 to 1.0 and approx. 0.6 to 0.9 arc min, respectively. We found that the larger the positioning error in a quadrant is, the larger its HPD is. The HPD map, which manifests the local image blurring, is very similar from quadrant to quadrant, but the map of the focus position is different from location to location in each telescope. It is also found that the difference in local performance causes energy dependence of the HPD.

Astro-H/Hitomi; soft x-ray telescope; SXT; Wolter ↗

Development of High Performance Detector Technology for UV and Near IR Applications

Sensing and imaging for ultraviolet (UV) and nearinfrared (NIR) bands has many applications forNASA, defense, and commercial systems. Recentwork has involved developing UV avalanchephotodiode (UV-APD) arrays with high gain for highresolution imaging. Various GaN/AlGaN p-i-n (PIN)UV-APDs have been fabricated from epitaxialstructures grown by MOCVD on GaN substrates withavalanche gains higher than 5 x 10(exp 5), and significantlyhigher responsivities. Likewise, the SiGe materialsystem allows the demonstration of high-performancedetector array technology that covers the 0.5 to 1.7 mwavelength range for visible and NIR bands ofinterest. We have utilized SiGe fabrication technologyto develop Ge based PIN detector devices on 300 mmSi wafers. We will discuss the theoretical andexperimental results from electrical and opticalcharacterization of the detector devices with variousn+ region doping concentrations to demonstrate low dark currents below 1 uA at -1 V and high photocurrent. Recent results from these detectorarrays for UV and NIR detection will be presented.

IR↗

Fabrication and Calibration of FORTIS

The Johns Hopkins University sounding rocket group is entering the final fabrication phase of the Far-ultraviolet Off Rowland-circle Telescope for Imaging and Spectroscopy (FORTIS); a sounding rocket borne multi-object spectro-telescope designed to provide spectral coverage of 43 separate targets in the 900 - 1800 Angstrom bandpass over a 30' x 30' field-of-view. Using "on-the-fly" target acquisition and spectral multiplexing enabled by a GSFC microshutter array, FORTIS will be capable of observing the brightest regions in the far-UV of nearby low redshift (z approximately 0.002 - 0.02) star forming galaxies to search for Lyman alpha escape, and to measure the local gas-to-dust ratio. A large area (approximately 45 mm x 170 mm) microchannel plate detector built by Sensor Sciences provides an imaging channel for targeting flanked by two redundant spectral outrigger channels. The grating is ruled directly onto the secondary mirror to increase efficiency. In this paper, we discuss the recent progress made in the development and fabrication of FORTIS, as well as the results of early calibration and characterization of our hardware, including mirror/grating measurements, detector performance, and early operational tests of the micro shutter arrays.

Fleming, Brian T.↗

Optimizing RHESSI X-ray Imaging

RHESSI X-ray imaging is possible with angular resolution as fine as 2 arcsec (FWHM) at energies from as low as 3 keV to >100 keV. However, taking full advantage of this capability has proven to be challenging given the Fourier-transform imaging technique that is used, specific instrumental considerations that must be taken into account, and the many different options of the available image reconstruction algorithms. Such considerations as the best reconstruction algorithm to use, the optimal weighting of the different Fourier components, deciding between short image integration times and rapid imaging cadence, the different energy ranges covered by the 9 detectors, the effect of pulse pile-up and albedo, etc. must all be taken into account in obtaining and interpreting RHESSI X-ray images. This poster describes different techniques for optimizing the image reconstruction depending on the science objectives - identifying compact or extended sources, searching for source motion, obtaining the best photometry, determining the believability of different features in an image, etc. The emphasis is on making full use of data from all the RHESSI detectors, including the ones behind the finest grids when warranted by the source structure. This is the case for the hard X-ray emission along the ribbons of the flare on 2005 May 13 reported by Liu et al. (2007) and this event will be used as an example.

Dennis, Brian R.↗

A 5-18 micron array camera for high-background astronomical imaging

A new infrared array camera system using a Hughes/SBRC 58 x 62 pixel hybrid Si:Ga array detector has been successfully applied to high-background 5-18-micron astronomical imaging observations. The off-axis reflective optical system minimizes thermal background loading and produces diffraction-limited images with negligible spatial distortion. The noise equivalent flux density (NEFD) of the camera at 10 microns on the 3.0-m NASA/Infrared Telescope Facility with broadband interference filters and 0.26 arcsec pixel is NEFD = 0.01 Jy/sq rt min per pixel (1sigma), and it operates at a frame rate of 30 Hz with no compromise in observational efficiency. The electronic and optical design of the camera, its photometric characteristics, examples of observational results, and techniques for successful array imaging in a high- background astronomical application are discussed.

Gezari, Daniel Y.↗

Correlations Between Panoramic Imagery and Gamma-Ray Background in an Urban Area

When searching for radiological sources in an urban area, a vehicle-borne detector system will often measure complex, varying backgrounds primarily from natural gamma-ray sources. Much work has been focused on developing spectral algorithms that retain sensitivity and minimize the false-positive rate even in the presence of such spectral and temporal variability. However, information about the environment surrounding the detector system might also provide useful clues about the expected background, which if incorporated into an algorithm, could improve performance. Recent work has focused on extensive measuring and modeling of urban areas with the goal of understanding how these complex backgrounds arise. This work presents an analysis of panoramic video images and gamma-ray background data collected in Oakland, California, by the radiological multisensor analysis platform (RadMAP) vehicle. Features were extracted from the panoramic images by semantically labeling the images and then convolving the labeled regions with the detector response. A linear model was used to relate the image-derived features to gamma-ray spectral features obtained using nonnegative matrix factorization (NMF) under different regularizations. Here we find some gamma-ray background features correlate strongly with image-derived features that measure the response-adjusted solid angle subtended by sky and buildings, and we discuss the implications for the development of future, contextually aware detection algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New technologies for UV detectors

Several technologies are currently being developed, leading to substantial improvements in the performance of UV detectors or significant reductions in power or weight. Four technologies discussed are (1) thin-film coatings to enhance the UV sensitivity of CCD's, (2) highly innovative magnet assemblies that dramatically reduce weight and result in virtually no external flux, (3) new techniques for curving microchannel plates (MCP's) so that single plates can be used to prevent ion feedback and present highly localized charge clouds to an anode structure, and (4) high-performance alternatives to glass-based MCP's. In item (2), for example, very robust magnets are made out of rare earth materials such as samarium cobalt, and cladding magnets are employed to prevent flux from escaping from the detector into the external environment. These new ultralight magnet assemblies are able to create strong, exceptionally uniform magnetic fields for image intensification and focusing of photoelectrons. The principle advantage of such detectors is the quantum efficiencies of 70-80 percent obtained throughout ultraviolet wavelengths (900-2000 A), the highest of any device. Despite the improvements achieved under item (3), high-performance alternatives to conventional glass-based MCP's potentially offer three distinct new advantages that include (1) a 30-100-fold improvement in dynamic range resulting in correspondingly higher signal-to-noise ratios, (2) the use of pure dielectric and semiconductor materials that will not outgas contaminants that eventually destroy photocathodes, and (3) channels that have constant spacing providing long-ranged order since the plates are made using photolithography techniques from the semiconductor industry. The manufacturers of these advanced-technology MCP's, however, are a couple of years away from actually producing a functioning image intensifier. In contrast to the use of CCD's for optical, ground based observations, there is no single detector technology in the ultraviolet that dominates or is as universally suitable for all applications. Thus, several technological problems, recent advances, and the impact that these new enabling technologies represent for UV applications are addressed.

Joseph, C. L.↗

Design, construction, and test of the Gas Pixel Detectors for the IXPE mission

Due to be launched in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2–8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode. In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance metrics and the operational aspects. We shall present a thorough characterization of the GPDs in terms of effective noise, trigger efficiency, dead time, uniformity of response, and spectral and polarimetric performance. In addition, we shall discuss in detail a number of instrumental effects that are relevant for high-level science analysis—particularly as far as the response to unpolarized radiation and the stability in time are concerned.

79 ASTRONOMY AND ASTROPHYSICS↗

A method for correcting aspect solution errors in ROSAT HRI observations of compact sources

X-ray point sources observed with the ROSAT High Resolution Imager (HRI) often appear elongated over scales of approximately 5 sec-10 sec from the image core. This elongation has been attributed to errors in the attitude correction as the satellite is wobbled during the observations, and affects sources with both soft and hard X-ray spectra. In this paper, I report the results of an attempt to rid a high signal-to-noise observation of the soft X-ray point source HZ 43 of its characteristic elongation. I divided the observation into 181 separate images, each containing photons from only a small region on the detector through which the source passed during the satellite's wobble. By measuring the positions of the individual image centroids, I found clear evidence for systematic offsets from a common mean by up to approximately +/- 3 sec in both right ascension and declination as a function of phase in the satellite wobble. Shifting the subimages to a common center and then restacking them into a single image measurably improved the symmetry of the point-spread function. HRI observations are wobbled primarily to smooth out variations in the pixel-to-pixel sensitivity of the detector and also to extend the lifetime of the microchannel plates in the detector since these decay at a given location as a function of the number of photons detected. However, the elongations introduced by the aspect errors inhibit the identification of possible extended X-ray emission associated with sources such as pulsars and active galactic nuclei. In light of these results, I suggest that until the aspect errors are understood, observations of compact sources, where this effect may be important, should not be wobbled.

Morse, Jon A.↗

Fabrication of Phononic Filter Structures for Far-IR/sub-mm Detector Applications

A photon noise limited sub-mm/far-IR cold telescope in space will require detectors with noise equivalent power (NEP) less than 1x10-19W/Hz1/2for imaging applications and at least an order of magnitude lower for spectroscopic studies. The detector NEP can be reduced by lowering the operation temperature and improving the thermal isolation between the bolometer and a heat bath. We report on the fabrication of membrane isolated transition edge sensor bolometers incorporating compact (<50 μm) thermal isolation beams based on phononic filters. Phononic filters are created by etching quasi-periodic nanoscale structures into supporting thermo-mechanical beams. The cross-sectional dimensions of the etched features are less than the thermal wavelength at the operating temperature, enabling coherent phonon transport to take place in one dimension. The phonon stop-band can be tuned by adjusting the scale of the quasi-periodic structures. Cascading multiple filter stages can increase bandwidth and provide improved thermal isolation similar to the function of a multi-stage electrical filter. We describe the fabrication of AlMn based transition edge sensor bolometers on silicon and silicon nitride membranes isolated by one-and two-dimensional phononic filters. The phononic filters are patterned through electron beam lithography and isolated with deep reactive ion etching.

Phononic↗

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.

47 OTHER INSTRUMENTATION↗

Large format imaging arrays for the Atacama Cosmology Telescope

We describe progress in the fabrication, characterization, and production of detector arrays for the Atacama Cosmology Telescope (ACT). The completed ACT instrument is specified to image simultaneously at 145, 225, and 265 GHz using three 32x32 filled arrays of superconducting transition edge sensors (TES) read out with time-division-multiplexed SQUID amplifiers. We present details of the pixel design and testing including the optimization of the electrical parameters for multiplexed readout. Using geometric noise suppression and careful tuning of operation temperature and device bias resistance, the excess noise in the TES devices is balanced with detector speed for interfacing with the ACT optics. The design also accounts for practical tolerances such as transition temperature gradients and scatter that occur in the production of multiple wafers to populate fully the kilopixel cameras. We have developed an implanted absorber layer compatible with our silicon-on-insulator process that allows for tunable optical resistance with requisite on-wafer uniformity and wafer-to-wafer reproducibility. Arrays of 32 elements have been tested in the laboratory environment including electrical, optical, and multiplexed performance. Given this pixel design, optical tests and modeling are used to predict the performance of the filled array under anticipated viewing conditions. Integration of the filled array of pixels with a tuned backshort and dielectric plate in front of the array maximize absorption and the focal plane and suppress reflections. A mechanical design for the build of the full structure is completed and we report on progress toward the construction of a prototype array for first light on the ACT.

Chervenak, J. A.↗

AEPF: Attention-Enabled Point Fusion for 3D Object Detection

Current state-of-the-art (SOTA) LiDAR-only detectors perform well for 3D object detection tasks, but point cloud data are typically sparse and lacks semantic information. Detailed semantic information obtained from camera images can be added with existing LiDAR-based detectors to create a robust 3D detection pipeline. With two different data types, a major challenge in developing multi-modal sensor fusion networks is to achieve effective data fusion while managing computational resources. With separate 2D and 3D feature extraction backbones, feature fusion can become more challenging as these modes generate different gradients, leading to gradient conflicts and suboptimal convergence during network optimization. To this end, we propose a 3D object detection method, Attention-Enabled Point Fusion (AEPF). AEPF uses images and voxelized point cloud data as inputs and estimates the 3D bounding boxes of object locations as outputs. An attention mechanism is introduced to an existing feature fusion strategy to improve 3D detection accuracy and two variants are proposed. These two variants, AEPF-Small and AEPF-Large, address different needs. AEPF-Small, with a lightweight attention module and fewer parameters, offers fast inference. AEPF-Large, with a more complex attention module and increased parameters, provides higher accuracy than baseline models. Experimental results on the KITTI validation set show that AEPF-Small maintains SOTA 3D detection accuracy while inferencing at higher speeds. AEPF-Large achieves mean average precision scores of 91.13, 79.06, and 76.15 for the car class’s easy, medium, and hard targets, respectively, in the KITTI validation set. Results from ablation experiments are also presented to support the choice of model architecture.

Chemistry↗

Finding Interstellar Particle Impacts on Stardust Aluminium Foils: The Safe Handling, Imaging, and Analysis of Samples Containing Femtogram Residues

Impact ionisation detectors on a suite of spacecraft have shown the direction, velocity, flux and mass distribution of smaller ISP entering the Solar System. During the aphelion segments of the Stardust flight, a dedicated collector surface was oriented to intercept ISP of beta = 1, and returned to Earth in January 2006. In this paper we describe the probable appeareance and size of IS particle craters from initial results of experimental impacts and numerical simulation, explain how foils are being prepared and mounted for crater searching by automated acquisition of high magnification electron images (whilst avoiding contamination of the foils) and comment on appropriate analytical techniques for Preliminary Examination (PE).

Kearsley, A. T.↗

Quantitative thermal diffusivity measurements of composites

A remote radiometric technique for making quantitative thermal diffusivity measurements is described. The technique was designed to make assessments of the structural integrity of large composite parts, such as wings, and can be performed at field sites. In the measurement technique, a CO2 laser beam is scanned using two orthogonal servo-controlled deflecting mirrors. An infrared imager, whose scanning mirrors oscillate in the vertical and the horizontal directions, is used as the detector. The analysis technique used to extract the diffusivity from these images is based on a thin infinite plate assumption, which requires waiting a given period of time for the temperature to equilibrate throughout the thickness of the sample. The technique is shown to be accurate to within two percent for values of the order of those for composite diffusivities, and to be insensitive to convection losses.

Heath, D. M.↗

Multiband selection with linear array detectors

Several techniques that can be used in an earth-imaging system to separate the linear image formed after the collecting optics into the desired spectral band are examined. The advantages and disadvantages of the Multispectral Linear Array (MLA) multiple optics, the MLA adjacent arrays, the imaging spectrometer, and the MLA beam splitter are discussed. The beam-splitter design approach utilizes, in addition to relatively broad spectral region separation, a movable Multiband Selection Device (MSD), placed between the exit ports of the beam splitter and a linear array detector, permitting many bands to be selected. The successful development and test of the MSD is described. The device demonstrated the capacity to provide a wide field of view, visible-to-near IR/short-wave IR and thermal IR capability, and a multiplicity of spectral bands and polarization measuring means, as well as a reasonable size and weight at minimal cost and risk compared to a spectrometer design approach.

Richard, H. L.↗

Dielectric Covered Planar Antennas at Submillimeter Wavelengths for Terahertz Imaging

Most optical systems require antennas with directive patterns. This means that the physical area of the antenna will be large in terms of the wavelength. When non-cooled systems are used, the losses of microstrip or coplanar waveguide lines impede the use of standard patch or slot antennas for a large number of elements in a phased array format. Traditionally, this problem has been solved by using silicon lenses. However, if an array of such highly directive antennas is to be used for imaging applications, the fabrication of many closely spaced lenses becomes a problem. Moreover, planar antennas are usually fed by microstrip or coplanar waveguides while the mixer or the detector elements (usually Schottky diodes) are coupled in a waveguide environment. The coupling between the antenna and the detector/ mixer can be a fabrication challenge in an imaging array at submillimeter wavelengths. Antennas excited by a waveguide (TE10) mode makes use of dielectric superlayers to increase the directivity. These antennas create a kind of Fabry- Perot cavity between the ground plane and the first layer of dielectric. In reality, the antenna operates as a leaky wave mode where a leaky wave pole propagates along the cavity while it radiates. Thanks to this pole, the directivity of a small antenna is considerably enhanced. The antenna consists of a waveguide feed, which can be coupled to a mixer or detector such as a Schottky diode via a standard probe design. The waveguide is loaded with a double-slot iris to perform an impedance match and to suppress undesired modes that can propagate on the cavity. On top of the slot there is an air cavity and on top, a small portion of a hemispherical lens. The fractional bandwidth of such antennas is around 10 percent, which is good enough for heterodyne imaging applications.The new geometry makes use of a silicon lens instead of dielectric quarter wavelength substrates. This design presents several advantages when used in the submillimeter-wave and terahertz bands: a) Antenna fabrication compatible with lithographic techniques. b) Much simpler fabrication of the lens. c) A simple quarter-wavelength matching layer of the lens will be more efficient if a smaller portion of the lens is used. d) The directivity is given by the lens diameter instead of the leaky pole (the bandwidth will not depend anymore on the directivity but just on the initial cavity). The feed is a standard waveguide, which is compatible with proven Schottky diode mixer/detector technologies. The development of such technology will benefit applications where submillimeter- wave heterodyne array designs are required. The main fields are national security, planetary exploration, and biomedicine. For national security, wideband submillimeter radars could be an effective tool for the standoff detection of hidden weapons or bombs concealed by clothing or packaging. In the field of planetary exploration, wideband submillimeter radars can be used as a spectrometer to detect trace concentrations of chemicals in atmospheres that are too cold to rely on thermal imaging techniques. In biomedicine, an imaging heterodyne system could be helpful in detecting skin diseases.

Chattopadhyay, Goutam↗