Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Snowmass2021 Computational Frontier White Paper: Cosmological Simulations and Modeling

Powerful new observational facilities will come online over the next decade, enabling a number of discovery opportunities in the "Cosmic Frontier", which targets understanding of the physics of the early universe, dark matter and dark energy, and cosmological probes of fundamental physics, such as neutrino masses and modifications of Einstein gravity. Synergies between different experiments will be leveraged to present new classes of cosmic probes as well as to minimize systematic biases present in individual surveys. Success of this observational program requires actively pairing it with a well-matched state-of-the-art simulation and modeling effort. Next-generation cosmological modeling will increasingly focus on physically rich simulations able to model outputs of sky surveys spanning multiple wavebands. These simulations will have unprecedented resolution, volume coverage, and must deliver guaranteed high-fidelity results for individual surveys as well as for the cross-correlations across different surveys. The needed advances are as follows: (1) Development of scientifically rich and broadly-scoped simulations, which capture the relevant physics and correlations between probes (2) Accurate translation of simulation results into realistic image or spectral data to be directly compared with observations (3) Improved emulators and/or data-driven methods serving as surrogates for expensive simulations, constructed from a finite set of full-physics simulations (4) Detailed and transparent verification and validation programs for both simulations and analysis tools. (Abridged)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On proton CT reconstruction using MVCT-converted virtual proton projections

Purpose: To describe a novel methodology of converting megavoltage x-ray projections into virtual proton projections that are otherwise missing due to the proton range limit. These converted virtual proton projections can be used in the reconstruction of proton computed tomography (pCT). Methods: Relations exist between proton projections and multispectral megavoltage x-ray projections for human tissue. Based on these relations, these tissues can be categorized into: (a) adipose tissue; (b) nonadipose soft tissues; and (c) bone. These three tissue categories can be visibly identified on a regular megavoltage x-ray computed tomography (MVCT) image. With an MVCT image and its projection data available, the x-ray projections through heterogeneous anatomy can be converted to the corresponding proton projections using predetermined calibration curves for individual materials, aided by a coarse segmentation on the x-ray CT image. To show the feasibility of this approach, mathematical simulations were carried out. The converted proton projections, plotted on a proton sinogram, were compared to the simulated ground truth. Proton stopping power images were reconstructed using either the virtual proton projections only or a blend of physically available proton projections and virtual proton projections that make up for those missing due to the range limit. These images were compared to a reference image reconstructed from theoretically calculated proton projections. Results: The converted virtual projections had an uncertainty of {+-}0.8% compared to the calculated ground truth. Proton stopping power images reconstructed using a blend of converted virtual projections (48%) and physically available projections (52%) had an uncertainty of {+-}0.86% compared with that reconstructed from theoretically calculated projections. Reconstruction solely from converted virtual proton projections had an uncertainty of {+-}1.1% compared with that reconstructed from theoretical projections. If these images are used for treatment planning, the average proton range uncertainty is estimated to be less than 1.5% for an imaging dose in the milligray range. Conclusions: The proposed method can be used to convert x-ray projections into virtual proton projections. The converted proton projections can be blended with existing proton projections or can be used solely for pCT reconstruction, addressing the range limit problem of pCT using current therapeutic proton machines.

60 APPLIED LIFE SCIENCES↗

Dissociative electron attachments to ethanol and acetaldehyde: A combined experimental and simulation study

Dissociation dynamics of the temporary negative ions of ethanol and acetaldehyde formed by the low-energy electron attachments is investigated by using the anion velocity map imaging technique and ab initio molecular dynamics simulations. The momentum images of the dominant fragments O{sup −}/OH{sup −} and CH{sub 3}{sup −} are recorded, indicating the low kinetic energies of O{sup −}/OH{sup −} for ethanol while the low and high kinetic energy distributions of O{sup −} ions for acetaldehyde. The CH{sub 3}{sup −} image for acetaldehyde also shows the low kinetic energy. With help of the dynamics simulations, the fragmentation processes are qualitatively clarified. A new cascade dissociation pathway to produce the slow O{sup −} ion via the dehydrogenated intermediate, CH{sub 3}CHO{sup −} (acetaldehyde anion), is proposed for the dissociative electron attachment to ethanol. After the electron attachment to acetaldehyde molecule, the slow CH{sub 3}{sup −} is produced quickly in the two-body dissociation with the internal energy redistributions in different aspects before bond cleavages.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using AI for Wave-front Estimation with the Rubin Observatory Active Optics System

Abstract The Vera C. Rubin Observatory will, over a period of 10 yr, repeatedly survey the southern sky. To ensure that images generated by Rubin meet the quality requirements for precision science, the observatory will use an active-optics system (AOS) to correct for alignment and mirror surface perturbations introduced by gravity and temperature gradients in the optical system. To accomplish this, Rubin will use out-of-focus images from sensors located at the edge of the focal plane to learn and correct for perturbations to the wave front. We have designed and integrated a deep-learning (DL) model for wave-front estimation into the AOS pipeline. In this paper, we compare the performance of this DL approach to Rubin’s baseline algorithm when applied to images from two different simulations of the Rubin optical system. We show the DL approach is faster and more accurate, achieving the atmospheric error floor both for high-quality images and low-quality images with heavy blending and vignetting. Compared to the baseline algorithm, the DL model is 40× faster, the median error 2× better under ideal conditions, 5× better in the presence of vignetting by the Rubin camera, and 14× better in the presence of blending in crowded fields. In addition, the DL model surpasses the required optical quality in simulations of the AOS closed loop. This system promises to increase the survey area useful for precision science by up to 8%. We discuss how this system might be deployed when commissioning and operating Rubin.

79 ASTRONOMY AND ASTROPHYSICS↗

Sample environment effects on synchrotron-measured temperature profiles in an approximant of optical floating zone crystal growth

Even though the growth of crystals using optical floating zone furnaces has had an immense scientific impact, the implementation of this method remains more of an art than a science due to the difficulty of obtaining quantitative information about the sample thermal profile during crystal growth. Building on recent work demonstrating that in situ synchrotron studies can be used to map sample rod temperatures during heating, investigations were carried out to better understand how the sample environment affects the sample temperature profile. Through a combination of experimental studies and modeling efforts, it is shown that the environment in the furnace can strongly influence the sample temperature at the lamp focus, the steepness of the vertical temperature gradient, and the timescale required for sample heating and cooling - effects which can combine to produce a strong history-dependence to sample temperature profiles. It is demonstrated that the furnace effects can be effectively captured in thermal models, allowing both the steady-state and time-dependent behavior of the sample to be accurately reproduced with predictive models, and providing a launching point for improved furnace designs that can more readily deliver desired thermal profiles.

36 MATERIALS SCIENCE↗

High-resolution bandpass x-ray imaging with crystal reflectors: Overcoming geometric aberrations

The imaging problem of a specular reflector is revisited. Retaining terms through the second order in the reflector surface expansion, we derive the form of the aberration-limiting aperture for arbitrary magnification, assuming no bandwidth limitations. A permissible relative aperture size of the reflector is limited by a set relative aberration tolerance and scales with the tangent of the central glancing angle of incidence. These limiting aberrations become practically insignificant near backscattering. The results extend to x-ray diffracting crystals in symmetric Bragg geometry shaped as an ellipsoid of revolution. This geometry permits polychromatic imaging for hard x-rays over a bandwidth defined by the accepted range of Bragg angles, thereby suppressing aberrations of higher orders. We assess ellipsoidal crystal imagers using ray tracing simulations for two high-magnification designs with Bragg angles far from and close to backscattering. Finally, in both cases, the ellipsoidal crystals produce images of higher quality compared to those formed by equivalent toroidal crystal imagers.

Bragg reflection↗

Using flow information to support 3D vessel reconstruction from rotational angiography

For the assessment of cerebrovascular diseases, it is beneficial to obtain three-dimensional (3D) morphologic and hemodynamic information about the vessel system. Rotational angiography is routinely used to image the 3D vascular geometry and we have shown previously that rotational subtraction angiography has the potential to also give quantitative information about blood flow. Flow information can be determined when the angiographic sequence shows inflow and possibly outflow of contrast agent. However, a standard volume reconstruction assumes that the vessel tree is uniformly filled with contrast agent during the whole acquisition. If this is not the case, the reconstruction exhibits artifacts. Here, we show how flow information can be used to support the reconstruction of the 3D vessel centerline and radii in this case. Our method uses the fast marching algorithm to determine the order in which voxels are analyzed. For every voxel, the rotational time intensity curve (R-TIC) is determined from the image intensities at the projection points of the current voxel. Next, the bolus arrival time of the contrast agent at the voxel is estimated from the R-TIC. Then, a measure of the intensity and duration of the enhancement is determined, from which a speed value is calculated that steers the propagation of the fast marching algorithm. The results of the fast marching algorithm are used to determine the 3D centerline by backtracking. The 3D radius is reconstructed from 2D radius estimates on the projection images. The proposed method was tested on computer simulated rotational angiography sequences with systematically varied x-ray acquisition, blood flow, and contrast agent injection parameters and on datasets from an experimental setup using an anthropomorphic cerebrovascular phantom. For the computer simulation, the mean absolute error of the 3D centerline and 3D radius estimation was 0.42 and 0.25 mm, respectively. For the experimental datasets, the mean absolute error of the 3D centerline was 0.45 mm. Under pulsatile and nonpulsatile conditions, flow information can be used to enable a 3D vessel reconstruction from rotational angiography with inflow and possibly outflow of contrast agent. We found that the most important parameter for the quality of the reconstruction of centerline and radii is the range through which the x-ray system rotates in the time span of the injection. Good results were obtained if this range was at least 135 deg. . As a standard c-arm can rotate 205 deg., typically one third of the acquisition can show inflow or outflow of contrast agent, which is required for the quantification of blood flow from rotational angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feature-space assessment of electrical impedance tomography coregistered with computed tomography in detecting multiple contrast targets

Purpose: Fusion of electrical impedance tomography (EIT) with computed tomography (CT) can be useful as a clinical tool for providing additional physiological information about tissues, but requires suitable fusion algorithms and validation procedures. This work explores the feasibility of fusing EIT and CT images using an algorithm for coregistration. The imaging performance is validated through feature space assessment on phantom contrast targets. Methods: EIT data were acquired by scanning a phantom using a circuit, configured for injecting current through 16 electrodes, placed around the phantom. A conductivity image of the phantom was obtained from the data using electrical impedance and diffuse optical tomography reconstruction software (EIDORS). A CT image of the phantom was also acquired. The EIT and CT images were fused using a region of interest (ROI) coregistration fusion algorithm. Phantom imaging experiments were carried out on objects of different contrasts, sizes, and positions. The conductive medium of the phantoms was made of a tissue-mimicking bolus material that is routinely used in clinical radiation therapy settings. To validate the imaging performance in detecting different contrasts, the ROI of the phantom was filled with distilled water and normal saline. Spatially separated cylindrical objects of different sizes were used for validating the imaging performance in multiple target detection. Analyses of the CT, EIT and the EIT/CT phantom images were carried out based on the variations of contrast, correlation, energy, and homogeneity, using a gray level co-occurrence matrix (GLCM). A reference image of the phantom was simulated using EIDORS, and the performances of the CT and EIT imaging systems were evaluated and compared against the performance of the EIT/CT system using various feature metrics, detectability, and structural similarity index measures. Results: In detecting distilled and normal saline water in bolus medium, EIT as a stand-alone imaging system showed contrast discrimination of 47%, while the CT imaging system showed a discrimination of only 1.5%. The structural similarity index measure showed a drop of 24% with EIT imaging compared to CT imaging. The average detectability measure for CT imaging was found to be 2.375 ± 0.19 before fusion. After complementing with EIT information, the detectability measure increased to 11.06 ± 2.04. Based on the feature metrics, the functional imaging quality of CT and EIT were found to be 2.29% and 86%, respectively, before fusion. Structural imaging quality was found to be 66% for CT and 16% for EIT. After fusion, functional imaging quality improved in CT imaging from 2.29% to 42% and the structural imaging quality of EIT imaging changed from 16% to 66%. The improvement in image quality was also observed in detecting objects of different sizes. Conclusions: The authors found a significant improvement in the contrast detectability performance of CT imaging when complemented with functional imaging information from EIT. Along with the feature assessment metrics, the concept of complementing CT with EIT imaging can lead to an EIT/CT imaging modality which might fully utilize the functional imaging abilities of EIT imaging, thereby enhancing the quality of care in the areas of cancer diagnosis and radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of fast 3D simulation and actinic inspection for EUV masks with buries defects

Aerial images for isolated defects and the interactions of defects with features are compared between the Actinic Inspection Tool (AIT) at Lawrence Berkeley National Laboratory (LBNL) and the fast EUV simulation program RADICAL. Comparisons between AIT images from August 2007 and RADICAL simulations are used to extract aberrations. At this time astigmatism was the dominant aberration with a value of 0.55 waves RMS. Significant improvements in the imaging performance of the AIT were made between August 2007 and December 2008. A good match will be shown between the most recent AIT images and RADICAL simulations without aberrations. These comparisons will demonstrate that a large defect, in this case 7nm tall on the surface, is still printable even if it is centered under the absorber line. These comparisons also suggest that the minimum defect size is between 1.5nm and 0.8nm surface height because a 1.5nm defect was printable but a 0.8nm was not. Finally, the image of a buried defect near an absorber line through focus will demonstrate an inversion in the effect of the defect from a protrusion of the dark line into the space to a protrusion of the space into the line.

36 MATERIALS SCIENCE↗

Simulation and modeling for the stand-off radiation detection system (SORDS) using GEANT4

A Stand-Off Radiation Detection System (SORDS) is being developed through a joint effort by Raytheon, Los Alamos National Laboratory, Bubble Technology Industries, Radiation Monitoring Devices, and the Massachusetts Institute of Technology, for the Domestic Nuclear Detection Office (DNDO). The system is a mobile truck-based platform performing detection, imaging, and spectroscopic identification of gamma-ray sources. A Tri-Modal Imaging (TMI) approach combines active-mask coded aperture imaging, Compton imaging, and shadow imaging techniques. Monte Carlo simulation and modeling using the GEANT4 toolkit was used to generate realistic data for the development of imaging algorithms and associated software code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Going Forward with the Nancy Grace Roman Space Telescope Transient Survey: Validation of Precision Forward-modeling Photometry for Undersampled Imaging

The Nancy Grace Roman Space Telescope (Roman) is an observatory for both wide-field observations and coronagraphy that is scheduled for launch in the mid-2020s. Part of the planned survey is a deep, cadenced field or fields that enable cosmological measurements with type Ia supernovae (SNe Ia). With a pixel scale of 0$_.^"$11, the Wide Field Instrument will be undersampled, presenting a difficulty for precisely subtracting the galaxy light underneath the SNe. We use simulated data to validate the ability of a forward-model code (such codes are frequently also called “scene-modeling” codes) to perform precision supernova photometry for the Roman SN survey. Our simulation includes over 760,000 image cutouts around SNe Ia or host galaxies (~10% of a full-scale survey). To have a realistic 2D distribution of underlying galaxy light, we use the VELA simulated high-resolution images of galaxies. We run each set of cutouts through our forward-modeling code which automatically measures time-dependent SN fluxes. Given our assumed inputs of a perfect model of the instrument point-spread functions and calibration, we find biases at the millimagnitude level from this method in four red filters (Y106, J129, H158, and F184), easily meeting the 0.5% Roman inter-filter calibration requirement for a cutting-edge measurement of cosmological parameters using SNe Ia. Simulated data in the bluer Z087 filter shows larger ~ 2–3 mmg biases, also meeting this requirement, but with more room for improvement. Our forward-model code has been released on Zenodo.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrating Experiments and Simulations to Reveal Anisotropic Growth Mechanisms and Interfaces of a One-Dimensional Zeolite

Zeolites are nanoporous crystalline materials critical for diverse industrial applications, yet their growth mechanisms are poorly understood. Here, this study presents a novel integrated framework combining experimental synthesis, high-resolution imaging, coarse-grained molecular dynamics simulations, and computer vision to uncover the mechanisms of growth of SSZ-24, a 1D channel zeolite. We demonstrate how synthesis conditions, such as temperature and reactant concentration, govern crystal anisotropy and surface roughness with growth dynamics differing markedly by crystallographic orientation. Along the channels, growth involves minimal energy barriers and rapid nucleation, resulting in rough surfaces. In contrast, growth perpendicular to the channels requires cooperative molecular organization and is highly sensitive to thermodynamic and kinetic conditions, yielding smooth anisotropic surfaces under low driving forces. By simulating transmission electron microscopy (TEM) images, we bridge molecular-scale simulations with experimental observations, identifying distinct growth mechanisms along different crystal planes. This work offers molecular-level insights into zeolite crystallization, advancing the rational design of nanoporous materials. The integration of cross-disciplinary methodologies establishes a transformative framework for optimizing zeolite synthesis, with implications for broader classes of materials.

Bertolazzo, Andressa A. [Univ. of Utah, Salt Lake ↗

Combined x-ray scattering, radiography, and velocity interferometry/streaked optical pyrometry measurements of warm dense carbon using a novel technique of shock-and-release

This work focused on a new application of the shock-and-release technique for equation of state (EOS) measurements. Warm dense matter states at near normal solid density and at temperatures close to 10 eV in diamond and graphite samples were created using a deep release from a laser-driven shock at the OMEGA laser facility. Independent temperature, density, and pressure measurements that do not depend on any theoretical models or simulations were obtained using imaging x-ray Thomson scattering, radiography, velocity interferometry, and streaked optical pyrometry. The experimental results were reproduced by the 2-D FLASH radiation hydrodynamics simulations finding a good agreement. The final EOS measurement was then compared with widely used SESAME EOS models as well as quantum molecular dynamics simulation results for carbon, which were very consistent with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT - a preliminary study

This work is to demonstrate that high quality cone beam CT images can be generated for a volume of interest (VOI) and to investigate the exposure reduction effect, dose saving, and scatter reduction with the VOI scanning technique. The VOI scanning technique involves inserting a filtering mask between the x-ray source and the breast during image acquisition. The mask has an opening to allow full x-ray exposure to be delivered to a preselected VOI and a lower, filtered exposure to the region outside the VOI. To investigate the effects of increased noise due to reduced exposure outside the VOI on the reconstructed VOI image, we directly extracted the projection data inside the VOI from the full-field projection data and added additional data to the projection outside the VOI to simulate the relative noise increase due to reduced exposure. The nonuniform reference images were simulated in an identical manner to normalize the projection images and measure the x-ray attenuation factor for the object. Regular Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the 3D images. The noise level inside the VOI was evaluated and compared with that of the full-field higher exposure image. Calcifications phantom and low contrast phantom were imaged. Dose reduction was investigated by estimating the dose distribution in a cylindrical water phantom using Monte Carlo simulation based Geant4 package. Scatter reduction at the detector input was also studied. Our results show that with the exposure level reduced by the VOI mask, the dose levels were significantly reduced both inside and outside the VOI without compromising the accuracy of image reconstruction, allowing for the VOI to be imaged with more clarity and helping to reduce the breast dose. The contrast-to-noise ratio inside the VOI was improved. The VOI images were not adversely affected by noisier projection data outside the VOI. Scatter intensities at the detector input were also shown to decrease significantly both inside and outside the VOI in the projection images, indicating potential improvement of image quality inside the VOI and contribution to dose reduction both inside and outside the VOI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimode turbulent flow measurements using magnetic resonance imaging- and laser-based techniques and computational fluid dynamics simulations

We studied the flow field characteristics of a turbulent flow over a regularized cube array with a perpendicular injection flow through the floor between the second and third cubical elements, representing the complex flow interactions of a 3D jet and the wake flows behind cubical obstacles. Four different experimental measurements were performed: two magnetic resonance imaging-based measurements for three-dimensional three-component velocity (MRV) and concentration (MRC) and two laser-based techniques, particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF), for two-dimensional two-component velocity and concentration measurement, respectively. The mainstream Reynolds number is Re = 15 000⁠, based on the primary inlet velocity U m and channel height D H ⁠, whereas the injector Reynolds number is Re j = 3400⁠, based on the injector velocity U j and the injector's exit width D j ⁠. Numerical simulations were performed for the studied flow configuration of turbulent flow over a regularized cube array using Reynolds-averaged Navier–Stokes (RANS) and large-eddy simulation (LES) approaches. Results obtained from experimental measurements—including MRV, MRC, PIV, and PLIF—as well as RANS and LES simulations are discussed and compared along several horizontal and vertical planes of the studied configuration. In addition, 3D turbulent flow structures, such as leading-edge vortex, horseshoe vortex, and jet shear-layer vortex, and the isosurfaces of scalar concentration successfully revealed by MRV and MRC techniques were found to be in very good agreement with those 3D features extracted from RANS and LES simulations. In conclusion, the high-resolution experimental and numerical database obtained from this study could be useful for validation and verification of numerical codes.

Computational fluid dynamics↗

Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10{sup −19}). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%–1.4%), false positives (4.0%–2.6%), and false negatives (2.7%–1.3%). These percentage reductions correspond to gating reducing image artifacts by 24–90 cm{sup 3} of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. Conclusions: For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm{sup 3} of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.

60 APPLIED LIFE SCIENCES↗

X-Ray reduction imaging of inclined reflective masks at critical angles

We have proposed and simulated optical schemes for producing reduced images by X-ray lasers or harmonic generators at a wavelength of ∼14 nm. The mask in this case is placed at a small angle to the optical axis, corresponding to the angle of total external reflection of the material. We have determined the optimal position of the detector (resist) and the corresponding spatial resolution. The results can be used to solve problems in nanotechnology and nanostructuring of surfaces. (x-ray optics)

77 NANOSCIENCE AND NANOTECHNOLOGY↗