Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Spacecraft crew procedures from paper to computers

Described here is a research project that uses human factors and computer systems knowledge to explore and help guide the design and creation of an effective Human-Computer Interface (HCI) for spacecraft crew procedures. By having a computer system behind the user interface, it is possible to have increased procedure automation, related system monitoring, and personalized annotation and help facilities. The research project includes the development of computer-based procedure system HCI prototypes and a testbed for experiments that measure the effectiveness of HCI alternatives in order to make design recommendations. The testbed will include a system for procedure authoring, editing, training, and execution. Progress on developing HCI prototypes for a middeck experiment performed on Space Shuttle Mission STS-34 and for upcoming medical experiments are discussed. The status of the experimental testbed is also discussed.

Oneal, Michael↗

Comparative Ergonomic Evaluation of Spacesuit and Space Vehicle Design

With the advent of the latest human spaceflight objectives, a series of prototype architectures for a new launch and reentry spacesuit that would be suited to the new mission goals. Four prototype suits were evaluated to compare their performance and enable the selection of the preferred suit components and designs. A consolidated approach to testing was taken: concurrently collecting suit mobility data, seat-suit-vehicle interface clearances, and qualitative assessments of suit performance within the volume of a Multi-Purpose Crew Vehicle mockup. It was necessary to maintain high fidelity in a mockup and use advanced motion-capture technologies in order to achieve the objectives of the study. These seemingly mutually exclusive goals were accommodated with the construction of an optically transparent and fully adjustable frame mockup. The construction of the mockup was such that it could be dimensionally validated rapidly with the motioncapture system. This paper describes the method used to create a space vehicle mockup compatible with use of an optical motion-capture system, the consolidated approach for evaluating spacesuits in action, and a way to use the complex data set resulting from a limited number of test subjects to generate hardware requirements for an entire population. Kinematics, hardware clearance, anthropometry (suited and unsuited), and subjective feedback data were recorded on 15 unsuited and 5 suited subjects. Unsuited subjects were selected chiefly based on their anthropometry in an attempt to find subjects who fell within predefined criteria for medium male, large male, and small female subjects. The suited subjects were selected as a subset of the unsuited medium male subjects and were tested in both unpressurized and pressurized conditions. The prototype spacesuits were each fabricated in a single size to accommodate an approximately average-sized male, so select findings from the suit testing were systematically extrapolated to the extremes of the population to anticipate likely problem areas. This extrapolation was achieved by first comparing suited subjects performance with their unsuited performance, and then applying the results to the entire range of the population. The use of a transparent space vehicle mockup enabled the collection of large amounts of data during human-in-the-loop testing. Mobility data revealed that most of the tested spacesuits had sufficient ranges of motion for the selected tasks to be performed successfully. A suited subject's inability to perform a task most often stemmed from a combination of poor field of view in a seated position, poor dexterity of the pressurized gloves, or from suit/vehicle interface issues. Seat ingress and egress testing showed that problems with anthropometric accommodation did not exclusively occur with the largest or smallest subjects, but also with specific combinations of measurements that led to narrower seat ingress/egress clearance.

England, Scott↗

Use of DES Modeling for Determining Launch Availability for SLS

(1) NASA is developing a new heavy lift launch system for human and scientific exploration beyond Earth orbit comprising of the Space Launch System (SLS), Orion Multi-Purpose Crew Vehicle (MPCV), and Ground Systems Development and Operations (GSDO); (2) The desire of the system is to ensure a high confidence of successfully launching the exploration missions, especially those that require multiple launches, have a narrow Earth departure window, and high investment costs; and (3) This presentation discusses the process used by a Cross-Program team to develop the Exploration Systems Development (ESD) Launch Availability (LA) Technical Performance Measure (TPM) and allocate it to each of the Programs through the use of Discrete Event Simulations (DES).

Watson, Michael↗

Motion sickness and proprioceptive aftereffects following virtual environment exposure

To study the potential aftereffects of virtual environments (VE), tests of visually guided behavior and felt limb position (pointing with eyes open and closed) along with self-reports of motion sickness-like discomfort were administered before and after 30 min exposure of 34 subjects. When post- discomfort was compared to a pre-baseline, the participants reported more sickness afterward (p < 0.03). The change in felt limb position resulted in subjects pointing higher (p < 0.038) and slightly to the left, although the latter difference was not statistically significant (p = 0.08). When findings from a second study using a different VE system were compared, they essentially replicated the results of the first study with higher sickness afterward (p < 0.001) and post- pointing errors were also up (p < 0.001) and to the left (p < 0.001). While alternative explanations (e.g. learning, fatigue, boredom, habituation, etc.) of these outcomes cannot be ruled out, the consistency of the post- effects on felt limb position changes in the two VE implies that these recalibrations may linger once interaction with the VE has concluded, rendering users potentially physiologically maladapted for the real world when they return. This suggests there may be safety concerns following VE exposures until pre-exposure functioning has been regained. The results of this study emphasize the need for developing and using objective measures of post-VE exposure aftereffects in order to systematically determine under what conditions these effects may occur.

NASA Discipline Neuroscience↗

sNebula, a network-based algorithm to predict binding between human leukocyte antigens and peptides

Understanding the binding between human leukocyte antigens (HLAs) and peptides is important to understand the functioning of the immune system. Since it is time-consuming and costly to measure the binding between large numbers of HLAs and peptides, computational methods including machine learning models and network approaches have been developed to predict HLA-peptide binding. However, there are several limitations for the existing methods. We developed a network-based algorithm called sNebula to address these limitations. We curated qualitative Class I HLA-peptide binding data and demonstrated the prediction performance of sNebula on this dataset using leave-one-out cross-validation and five-fold cross-validations. Furthermore, this algorithm can predict not only peptides of different lengths and different types of HLAs, but also the peptides or HLAs that have no existing binding data. We believe sNebula is an effective method to predict HLA-peptide binding and thus improve our understanding of the immune system.

60 APPLIED LIFE SCIENCES↗

Do Programmers Prefer Predictable Expressions in Code?

Source code is a form of human communication, albeit one where the information shared between the programmers reading and writing the code is constrained by the requirement that the code executes correctly. Programming languages are more syntactically constrained than natural languages, but they are also very expressive, allowing a great many different ways to express even very simple computations. Still, code written by developers is highly predictable, and many programming tools have taken advantage of this phenomenon, relying on language model surprisal as a guiding mechanism. Additionally, while surprisal has been validated as a measure of cognitive load in natural language, its relation to human cognitive processes in code is still poorly understood. In this paper, we explore the relationship between surprisal and programmer preference at a small granularity—do programmers prefer more predictable expressions in code? Using meaning-preserving transformations, we produce equivalent alternatives to developer-written code expressions and run a corpus study on Java and Python projects. In general, language models rate the code expressions developers choose to write as more predictable than these transformed alternatives. Then, we perform two human subject studies asking participants to choose between two equivalent snippets of Java code with different surprisal scores (one original and transformed). We find that programmers do prefer more predictable variants, and that stronger language models like the transformer align more often and more consistently with these preferences.

97 MATHEMATICS AND COMPUTING↗

Twelfth Annual Conference on Manual Control

Main topics discussed cover multi-task decision making, attention allocation and workload measurement, displays and controls, nonvisual displays, tracking and other psychomotor tasks, automobile driving, handling qualities and pilot ratings, remote manipulation, system identification, control models, and motion and visual cues. Sixty-five papers are included with presentations on results of analytical studies to develop and evaluate human operator models for a range of control task, vehicle dynamics and display situations; results of tests of physiological control systems and applications to medical problems; and on results of simulator and flight tests to determine display, control and dynamics effects on operator performance and workload for aircraft, automobile, and remote control systems.

Wempe, T. E.↗

Objective evaluation of situation awareness for dynamic decision makers in teleoperations

Situation awareness, a current mental mode of the environment, is critical to the ability of operators to perform complex and dynamic tasks. This should be particularly true for teleoperators, who are separated from the situation they need to be aware of. The design of the man-machine interface must be guided by the goal of maintaining and enhancing situation awareness. The objective of this work has been to build a foundation upon which research in the area can proceed. A model of dynamic human decision making which is inclusive of situation awareness will be presented, along with a definition of situation awareness. A method for measuring situation awareness will also be presented as a tool for evaluating design concepts. The Situation Awareness Global Assessment Technique (SAGAT) is an objective measure of situation awareness originally developed for the fighter cockpit environment. The results of SAGAT validation efforts will be presented. Implications of this research for teleoperators and other operators of dynamic systems will be discussed.

Endsley, Mica R.↗

Automatic Locking of Laser Frequency to an Absorption Peak

An electronic system adjusts the frequency of a tunable laser, eventually locking the frequency to a peak in the optical absorption spectrum of a gas (or of a Fabry-Perot cavity that has an absorption peak like that of a gas). This system was developed to enable precise locking of the frequency of a laser used in differential absorption LIDAR measurements of trace atmospheric gases. This system also has great commercial potential as a prototype of means for precise control of frequencies of lasers in future dense wavelength-division-multiplexing optical communications systems. The operation of this system is completely automatic: Unlike in the operation of some prior laser-frequency-locking systems, there is ordinarily no need for a human operator to adjust the frequency manually to an initial value close enough to the peak to enable automatic locking to take over. Instead, this system also automatically performs the initial adjustment. The system (see Figure 1) is based on a concept of (1) initially modulating the laser frequency to sweep it through a spectral range that includes the desired absorption peak, (2) determining the derivative of the absorption peak with respect to the laser frequency for use as an error signal, (3) identifying the desired frequency [at the very top (which is also the middle) of the peak] as the frequency where the derivative goes to zero, and (4) thereafter keeping the frequency within a locking range and adjusting the frequency as needed to keep the derivative (the error signal) as close as possible to zero. More specifically, the system utilizes the fact that in addition to a zero crossing at the top of the absorption peak, the error signal also closely approximates a straight line in the vicinity of the zero crossing (see Figure 2). This vicinity is the locking range because the linearity of the error signal in this range makes it useful as a source of feedback for a proportional + integral + derivative control scheme that constantly adjusts the frequency in an effort to drive the error to zero. When the laser frequency deviates from the midpeak value but remains within the locking range, the magnitude and sign of the error signal indicate the amount of detuning and the control circuitry adjusts the frequency by what it estimates to be the negative of this amount in an effort to bring the error to zero.

Koch, Grady J.↗

COBALT: A GN&C Payload for Testing ALHAT Capabilities in Closed-Loop Terrestrial Rocket Flights

The COBALT (CoOperative Blending of Autonomous Landing Technology) payload is being developed within NASA as a risk reduction activity to mature, integrate and test ALHAT (Autonomous precision Landing and Hazard Avoidance Technology) systems targeted for infusion into near-term robotic and future human space flight missions. The initial COBALT payload instantiation is integrating the third-generation ALHAT Navigation Doppler Lidar (NDL) sensor, for ultra high-precision velocity plus range measurements, with the passive-optical Lander Vision System (LVS) that provides Terrain Relative Navigation (TRN) global-position estimates. The COBALT payload will be integrated onboard a rocket-propulsive terrestrial testbed and will provide precise navigation estimates and guidance planning during two flight test campaigns in 2017 (one open-loop and closed- loop). The NDL is targeting performance capabilities desired for future Mars and Moon Entry, Descent and Landing (EDL). The LVS is already baselined for TRN on the Mars 2020 robotic lander mission. The COBALT platform will provide NASA with a new risk-reduction capability to test integrated EDL Guidance, Navigation and Control (GN&C) components in closed-loop flight demonstrations prior to the actual mission EDL.

Carson, John M., III↗

Air Traffic Controller Performance and Acceptability of Multiple UAS in a Simulated NAS Environment

Previously, we showed that air traffic controllers (ATCos) rated UAS pilot verbal response latencies as acceptable when a 1.5 s delay was added to the UAS pilot responses, but a 5 s delay was rated as mostly unacceptable. In the present study we determined whether a 1.5 s added delay in the UAS pilots' verbal communications would affect ATCos interactions with UAS and other conventional aircraft when the number and speed of the UAS were manipulated. Eight radar-certified ATCos participated in this simulation. The ATCos managed a medium altitude sector containing arrival aircraft, en route aircraft, and one to four UAS. The UAS were conducting a surveillance mission and flew at either a "slow" or "fast" speed. We measured both UAS and conventional pilots' verbal communication latencies, and obtained ATCos' acceptability ratings for these latencies. Although the UAS pilot response latencies were longer than those of conventional pilots, the ATCos rated UAS pilot verbal communication latencies to be as acceptable as those of conventional pilots. Because the overall traffic load within the sector was held constant, ATCos only performed slightly worse when multiple UAS were in their sector compared to when only one UAS was in the sector. Implications of these findings for UAS integration in the NAS are discussed.

measured response↗

Analytical method for nitroaromatic explosives in radiologically contaminated soil for ISO/IEC 17025 accreditation

Here, unique hazards are presented in the analysis of radiologically contaminated samples. Strenuous safety and security precautions must be in place to protect the analyst, laboratory, and instrumentation used to perform analyses. A validated method has been optimized for the analysis of select nitroaromatic explosives and degradative products using gas chromatography/mass spectrometry via sonication extraction of radiologically contaminated soils, for samples requiring ISO/IEC 17025 laboratory conformance. Target analytes included 2-nitrotoluene, 4-nitrotoluene, 2,6-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the degradative product 4-amino-2,6-dinitrotoluene. Analytes were extracted from soil in methylene chloride by sonication. Administrative and engineering controls, as well as instrument automation and quality control measures, were utilized to minimize potential human exposure to radiation at all times and at all stages of analysis, from receiving through disposition. Though thermal instability increased uncertainties of these selected compounds, a mean lower quantitative limit of 2.37 µg/mL and mean accuracy of 2.3% relative error and 3.1% relative standard deviation were achieved. Quadratic regression was found to be optimal for calibration of all analytes, with compounds of lower hydrophobicity displaying greater parabolic curve. Blind proficiency testing (PT) of spiked soil samples demonstrated a mean relative error of 9.8%. Matrix spiked analyses of PT samples demonstrated that 99% recovery of target analytes was achieved. To the knowledge of the authors, this represents the first safe, accurate, and reproducible quantitative method for nitroaromatic explosives in soil for specific use on radiologically contaminated samples within the constraints of a nuclear analytical lab.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-D-BRE-01: A Realistic Breathing Phantom of the Thorax for Testing New Motion Mitigation Techniques with Scanning Proton Therapy

Purpose: A prototype breathing phantom (named LuCa) has been developed which simulates the anatomy and motion of a patient thorax.In this work, we describe the results of the first commissioning tests with LuCa. Methods: The phantom provides a close representation of the human thorax. The lungs,contained within a tissue-equivalent ribcage and skin,are made from a polymer foam,which is inflated and deflated using a custommade ventilator. A tumor is simulated using a wooden ball with cutplanes for placing GafChromic films. The ventilator,controlled with Labview software,simulates a full range of breathing motion types.Commissioning tests were performed to assess its performance using imaging (CT and radiographic) and film dosimetry as follows:i)maximum Tumor excursion at acceptable pressure ranges, ii)tumor Motion repeatability between breathing periods,iii)reproducibility between measurement days,iv)tumor-to-surface motion correlation and v)reproducibility of film positioning in phantom. Results: The phantom can generate repeatable motion patterns with sin{sup 4},sin,breath-hold (tumor amplitude repeatability <0.5mm over 10min),aswell as patient-specific motion types. Maximum excursions of the tumor are 20mm and 14mm for the large and small tumor inserts respectively. Amplitude reproducibility (Coefficient of Variation) averaged at 16% for the workable pressure range over 2 months. Good correlation between tumor and surface motion was found with R{sup 2}=0.92. Reproducibility of film positioning within the thorax was within 0.9mm, and maximum 3° error from the coronal plane. Film measurements revealed that the film repositioning error yields relative errors in the mean dose over the planned target volume (PTV) of up to 2.5% and 4.5% for films at the center and on the edge of the PTV respectively. Conclusion: Commissioning tests have shown that the LuCa phantom can produce tumor motion with excellent repeatability. However,a poorer performance in reproducibility of tumor amplitude for a given peak pressure week-to-week. Film set-up reproducibility is adequate for detection of dosimetric errors resulting from motion of >3%. This work is funded by Swiss National Fund Grants 320030-127569 and 320030-1493942-1.

60 APPLIED LIFE SCIENCES↗

Pilot and Controller Workload and Situation Awareness with Three Traffic Management Concept

This paper reports on workload and situation awareness of pilots and controllers participating in a human-in-the-loop simulation using three different distributed air-ground traffic management concepts. Eight experimental pilots started the scenario in an en-route phase of flight and were asked to avoid convective weather while performing spacing and merging tasks along with a continuous descent approach (CDA) into Louisville Standiford Airport (SDF). Two controllers managed the sectors through which the pilots flew, with one managing a sector that included the Top of Descent, and the other managing a sector that included the merge point for arrival into SDF. At 3-minute intervals in the scenario, pilots and controllers were probed on their workload or situation awareness. We employed one of three concepts of operation that distributed separation responsibility across human controllers, pilots, and automation to measure changes in operator situation awareness and workload. We found that when pilots were responsible for separation, they had higher levels of awareness, but not necessarily higher levels of workload. When controllers are responsible and actively engaged, they showed higher workload levels compared to pilots and changes in awareness that were dependent on sector characteristics.

Vu, Kim-Phuong L.↗

Integrating human factors issues into critical portable detection usage - 121

There are multiple situations where portable detection systems are used to quantify distributed radionuclides. Such applications include holdup measurements in decommissioning activities, other routine usage and safeguards applications. Human factors dominate equipment deployment and operation and have significant impact upon the resulting data collection and its quality. Equipment use includes simultaneous positioning and targeting the object/region being quantified, observation and reporting of incoming data, often in difficult conditions and often while dressed in protective equipment. We examine the human interface with the equipment and other human factors where balance, perception, situational awareness and personnel health level influence the physical control and positioning of the detector. All these aspects impact both the measurement outcome and the Total Measurement Uncertainty (TMU). In this work, we are developing approaches and solutions to: 1. Initiate an inclusive program to assess and evolve human factors aspects of the interface to provide real time feedback tailored to a specific field operator profile. 2. Develop a measurement system human interface on a 'bench top' detection system to allow for both audio and visual I/O for auditory attention and situational (objective and subjective) awareness across varied end user characteristics. 3. Assess and develop an enhanced health assessment plan to identify and monitor pertinent auditory and balance characteristics for operator(s) interface and physical control of the gamma detector. Use the plan to verify personnel ability for effective deployment. We take a multidisciplinary approach to maximize accuracy, efficiency, and safety for the end-user to optimize project and measurement performance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Jiangsu Nanjing – Lawrence Berkeley Life Sciences Center for Translational Medicine (CRADA AWD00000392)

Project 1: Our previous work demonstrated that the CES biomarker can be an approximate measure for the levels of chromosomal instability (CIN) in cancer, and that the CES (for Centromere and kinetochore gene Expression Score) biomarker effectively predicts which cancer patients benefit from adjuvant chemotherapies in lung and other cancer types. Such a utility can potentially reduce overtreatment that is common in lung cancer treatment. We determined performance of the multiplex Quantigene RNA assay platform for measuring mRNA levels of CES genes using clinical tumor samples. These experiments determined sensitivity, specificity and detection limit of 12 CES genes and 5 control genes using clinical tumor samples with paired normal tissue samples. We determined how sample concentration and storage conditions affect measurement sensitivity and specificity, and whether sample storage over time affects result reproducibility. Importantly, we confirmed that early stage lung cancer CES values are significantly higher than those of paired normal tissues in all cases. This result greatly extended our bioinformatic data mining by confirming that we can measure CES values directly from patient tumor tissue, and that tumors have higher CES values than normal tissues. Unfortunately, our CRADA partner in China did not finish measuring CES expression levels for a larger group of ~100 tumor samples, due to the long period time required for human subject review in China. This delay prevented us from generating enough additional data to generate a significant statistical model. We finished analyzing all the data acquired during the CRADA, and are trying to work collaboratively with the Shanghai University Lung Cancer Hospital to complete the analysis of more tumor samples. Although no publications have resulted from this research, the findings are crucial for ongoing efforts to obtain funding to develop the technology to address problems in deciding on appropriate treatment regimens for individual patients, in clinical settings. Project 2: The overarching milestones of CRADA Project 2 were to investigate the role of FAM83 family members in cancer progression. Two publications resulted from this work which are highlighted below. The first major goal of the CRADA was to broadly assess the role of FAM83 family oncogenes in human cancer using a multi-omic bioinformatic approach (Snijders et al 2017 Mol. Oncol 11). The second major goal was to specifically assess the role of FAM83D in a cancer progression and metastasis (Yin et al 2019 Cell Oncol; in revision). Role of FAM83 family oncogenes in human cancers Recent studies from our laboratory as well as other groups have demonstrated that FAM83 family members have oncogenic properties and have significantly elevated expression levels in multiple human tumor types, including breast cancers (BC). We performed an integrative multi-omics bio-informatic analysis of the role of FAM83 family oncogenes in human cancers. Our findings were published in the journal Molecular Oncology (Snijders et al; Mol Oncol. 2017 Feb;11(2):167-179). Highlights from this manuscript are: • Transcriptional levels of FAM83 family members are frequently and dramatically elevated across tumor types in human • DNA copy number increase appears to be a potential mechanism for increased expression of FAM83 genes • FAM83 family gene signature is associated with poor survival across human tumor types • FAM83 gene alterations are significantly correlated with TP53, PIK3CA and Ecadherin mutations. In conclusion, this analysis of FAM83 family members opened up a new horizon for further understanding the significance of FAM83 genes in cancer and clinical applications in diagnosis, prognosis and therapy. Role of FAM83D in human non-small cell lung cancer (NSCLC) metastasis and its impact on chemotherapy. Lung cancer is one of the most common malignant tumors in the world and non-small cell lung cancer (NSCLC) accounts for 80~85% of all diagnosed lung cancer cases, one of the deadliest cancers worldwide. FAM83D has been proposed as an oncoprotein in several types of human cancer, yet its role and molecular mechanism in human non-small cell lung cancer (NSCLC) metastasis and its impact on chemotherapy are poorly understood. We evaluated the expression of FAM83D in NSCLC cells and cancerous tissues and its prognostic significance, then investigated the effect of FAM83D on tumorigenic phenotypes such as cell proliferation, EMT and invasive capability, and finally assessed impact of FAM83D on NSCLC chemo-drug resistance. The results of this study are currently in revision at the journal Cellular Oncology. Highlights from this manuscript are: • FAM83D expression is elevated in NSCLC cells and tissues and associated with poor prognosis • FAM83D promotes NSCLC cell proliferation • FAM83D induces EMT in NSCLC cells • FAM83D promotes NSCLC cell migration and invasion • FAM83D promotes EMT and invasive capability of NSCLC cells by regulating AKT/mTOR pathway • FAM83D silencing increases cisplatin sensitivity of NSCLC cells In summary, this second study demonstrated for the first time that FAM83D promoted EMT and metastasis of NSCLC cells through AKT/mTOR signal pathway as well as increased the sensitivity of NSCLC to cisplatin. This study may provide potential targets for advanced NSCLC treatment and personalized therapy.

59 BASIC BIOLOGICAL SCIENCES↗

Analytical capabilities for iodine detection: Review of possibilities for different applications

This Review summarizes a range of analytical techniques that can be used to detect, quantify, and/or distinguish between isotopes of iodine (e.g., long-lived 129 I, short-lived 131 I, stable 127 I). One reason this is of interest is that understanding potential radioiodine release from nuclear processes is crucial to prevent environmental contamination and to protect human health as it can incorporate into the thyroid leading to cancer. It is also of interest for evaluating iodine retention performances of next-generation iodine off-gas capture materials and long-term waste forms for immobilizing radioiodine for disposal in geologic repositories. Depending upon the form of iodine (e.g., molecules, elemental, and ionic) and the matter state (i.e., solid, liquid, and gaseous), the available options can vary. In addition, several other key parameters vary between the methods discussed herein, including the destructive vs nondestructive nature of the measurement process (including in situ vs ex situ measurement options), the analytical data collection times, and the amount of sample required for analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-G-IeP4-10: Microimaging for Different Degrees of Human Cavernous Hemangioma of Liver by Using In-Line Phase-Contrast Imaging CT

Purpose: Cavernous hemangioma of the liver (CHL) is the most common benign solid tumor of the liver. In this study, we quantitative assessment the different degrees of CHL from microscopic viewpoint by using in-line phase-contrast imaging CT (ILPCI-CT). Methods: The experiments were performed at x-ray imaging and biomedical application beamline (BL13W1) of Shanghai Synchrotron Radiation Facility (SSRF) in China. Three typical specimens at different stages, i.e., mild, moderate and severe human CHL were imaged using ILPCI-CT at 16keV without contrast agents. The 3D visualization of different degrees of CHL samples were presented using ILPCI-CT. Additionally, quantitative evaluation of the CHL features, such as the range of hepatic sinusoid equivalent diameters in different degrees of CHL samples, the ratio of the hepatic sinusoid to the CHL tissue, were measured. Results: The planar image clearly displayed the dilated hepatic sinusoids in microns. There was no normal hepatic vascular found in the all CHL samples. Different stages of CHL samples were presented with vivid shapes and stereoscopic effects by using 3D visualization. The equivalent diameters of hepatic sinusoids in three degrees CHL were different. The equivalent diameters of the hepatic sinusoids in mild CHL, range from 60 to 120 µm. The equivalent diameters of the hepatic sinusoids in moderate CHL, range from 65 to 190 µm. The equivalent diameters of the hepatic sinusoids in severe CHL, range from 95 to 215 µm. The ratio of the hepatic sinusoid to the mild, moderate and severe CHL tissue were 3%, 16% and 21%, respectively. Conclusion: The results show that the high degree of sensitivity of the ILPCI-CT technique and demonstrate the feasibility of accurate visualization of different stage human CHL. ILPCI-CT may offers a potential use in non-invasive study and analysis of CHL.

60 APPLIED LIFE SCIENCES↗