Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

ARCADES: analysis of risk from cyberattack against defensive strategies for the power grid

In this study, the authors introduce ARCADES (Analysis of Risk from Cyberattack against DEfensive Strategy), a technique to systematically explore the cybersecurity defence strategies based on contingency rankings in power systems. While cybersecurity defensive standards exist, these approaches are primarily based on expert opinions, rather than systematic studies of risk. ARCADES presents an approach to identify improved cybersecurity defensive strategies based on a graph‐based cyber‐physical security model that is evaluated by resistance‐distance metrics and then prioritised based on contingency analysis studies of the system. This study also proposed a technique that identifies the most critical cybersecurity mechanisms to protect the power grid. Planning and operation: those two applications for cybersecurity on power grid mainly explored in this study. For planning, a systematic method is developed to verify the effectiveness of security strategies and for operation, prioritised the security mechanism for auditing and monitoring purpose. As a case study, they analyse the IEEE‐14 bus, IEEE‐30 bus, and IEEE‐118 bus systems, observe the defensive strategies, and calculate substation criticality ranking by using the authors’ proposed method.

Touhiduzzaman, Md↗

Enhancing Grid Resilience with HIVE: Decentralized V2G Coordination for Black Starts

This paper proposes the HIVE (Harmonized Integration of Vehicle Energy for Grid Support) model, a novel game-theoretic framework for decentralized coordination of electrified vehicles to enable black start and load restoration during grid outages. In the absence of a central controller, HIVE employs a cooperative game to model vehicle interactions, allowing autonomous decision-making while admitting to a Nash equilibrium for grid restoration. The framework addresses the heterogeneity of vehicles and their operational constraints, selecting a lead vehicle for grid-forming and coordinating grid-following vehicles to support prioritized loads. Applied to a hospital blackout scenario, HIVE demonstrates robust performance in forming an islanded microgrid and sustaining critical loads under varying vehicle availability, state of charge, and power constraints. Simulation results highlight the model’s effectiveness in ensuring decentralized coordination of energy allocation and prioritizing loads, offering a scalable solution for resilient grid operations.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Integrated Synchronization Control of Grid-Forming Inverters for Smooth Microgrid Transition

This paper develops an integrated synchronization control technique for a grid-forming inverter operating within a microgrid that can improve the microgrid's transients during microgrid transition operation. This integrated synchronization control includes the disconnection synchronization control and the reconnection synchronization control. The simulation results show that the developed synchronization control works effectively to smooth the angle change of the grid-forming inverter during microgrid transition operation. Thus, the microgrid's transients are significantly improved compared to the case without synchronization control.

control↗

Inverter Controls for Smooth Transition Operation of Networked Microgrids

Islanding sections of a distribution grid as microgrids and networking these microgrids offer promising opportunities for improving system reliability; however, this approach may need distributed energy resources (DERs) to switch between grid-connected and islanded operation without affecting the system stability. The Thevenin impedance of the power system at the DER point of common coupling changes due to networking actions. It is critical to have smooth transitions between modes to ensure stable system operation and to avoid nuisance tripping. This paper presents the design of a grid-forming (GFM)-capable inverter control scheme to reliably operate in distribution systems with networked microgrids. Control mechanisms for smooth transitions between grid-following (GFL) and GFM inverter modes are presented. First, we test the control mechanism on a simple two-source power system through electromagnetic transient (EMT) simulations using a digital real-time simulator. Then, we add multiple such DERs to the EMT model of a real-world distribution feeder and demonstrate stable operation between mode transitions during the networking of the microgrids.

grid forming controls↗

Defining a Use Case for the ADMS Test Bed: Fault Location, Isolation, and Service Restoration with Distributed Energy Resources

Advanced distribution management systems (ADMS) integrate multiple enterprise-level functions into a single platform and offer advanced applications such as fault location, isolation, and service restoration (FLISR), to utilities to meet their operational needs for a modernized grid. These applications need to operate reliably even as distributed energy resource (DER) penetration increases on distribution systems. The ADMS test bed at the National Renewable Energy Laboratory offers utilities and vendors the opportunity to evaluate the performance of such advanced applications on distribution feeders of the future and to understand their potential benefits for a specific utility. This is done through defining use cases that address specific questions. This paper presents the definition of a use case on the performance of a commercially-available FLISR application on a feeder of an electric cooperative with DERs. After experiments are completed, results from this use case will be disseminated to the electric utility and research community to improve understanding of the challenges and benefits that DERs present to ADMS applications and the operation of a modernized grid.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Defining a Use Case for the ADMS Test Bed: Fault Location, Isolation, and Service Restoration with Distributed Energy Resources: Preprint

Advanced distribution management systems (ADMS) integrate multiple enterprise-level functions into a single platform and offer advanced applications such as fault location, isolation, and service restoration (FLISR), to utilities to meet their operational needs for a modernized grid. These applications need to operate reliably even as distributed energy resource (DER) penetration increases on distribution systems. The ADMS test bed at the National Renewable Energy Laboratory offers utilities and vendors the opportunity to evaluate the performance of such advanced applications on distribution feeders of the future and to understand their potential benefits for a specific utility. This is done through defining use cases that address specific questions. This paper presents the definition of a use case on the performance of a commercially-available FLISR application on a feeder of an electric cooperative with DERs. Results from this use case will be disseminated to the electric utility and research community to improve understanding of the challenges and benefits that DERs present to ADMS applications and the operation of a modernized grid.

61 RADIATION PROTECTION AND DOSIMETRY↗

Li + -Desolvation Dictating Lithium-Ion Battery’s Low-Temperature Performances

Lithium (Li) ion battery (LIB) has penetrated almost every aspects of human life, from portable electronics, vehicles to grids, and its operation stability in extreme environments becomes increasingly important. Among these, sub-zero temperature presents a kinetic challenge to the electrochemical reactions required to deliver the stored energy. In this work, we attempted to identify the rate-determining process for Li+ migration under such low temperatures, so that an optimum electrolyte formulation could be designed to maximize the energy output. Substantial increase in available capacities from graphite||LiNi0.80Co0.15Al0.05O2 chemistry down to -40°C is achieved by reducing the solvent molecule that more tightly binds to Li+ and thus constitutes high desolvation energy barrier. The fundamental understanding is applicable universally to all electrochemical devices that have to operate in similar environments.

desolvation↗

Variation of anode grid surface morphology and its effect on operation of a triode virtual cathode oscillator

After repeatedly operation of a triode virtual cathode oscillator, the surface morphology of anode grid is studied by a scanning electron microscope. It is found that there are many quasi-periodic sawteeth formed on the anode grid, which are about 300-500 {mu}m in height, {approx}200 {mu}m in width, and 150-200 {mu}m in period. The formation of this sawteeth implies that there is possible Rayleigh-Taylor-like instability on the anode grid during the irradiation by high-current relativistic electron beam. These sawteeth enhance the electric field on anode grid, leading to more feasible of anode plasma generation, and more rapidly expansion of that plasma. As a result, the electron transmissivity of anode grid is decreased, the output microwave power of the virtual cathode oscillator is lowered and its operational performance is degraded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Testbed Environment for Buildings-to-Grid Cyber Resilience Research and Development

The Smart Grid is characterized by the proliferation of advanced digital controllers at all levels of its operational hierarchy from generation to end consumption. Such controllers within modern residential and commercial buildings enable grid operators to exercise fine-grained control over energy consumption through several emerging Buildings-to-Grid (B2G) applications. Though this capability promises significant benefits in terms of operational economics and improved reliability, cybersecurity weaknesses in the supporting infrastructure could be exploited to cause a detrimental effect and this necessitates focused research efforts on two fronts. First, the understanding of how cyber attacks in the B2G space could impact grid reliability and to what extent. Second, the development and validation of cyber-physical application-specific countermeasures that are complementary to traditional infrastructure cybersecurity mechanisms for enhanced cyber attack detection and mitigation. The PNNL B2G testbed is currently being developed to address these core research needs. Specifically, the B2G testbed combines high-fidelity buildings+grid simulators, industry-grade building automation and Supervisory Control and Data Acquisition (SCADA) systems in an integrated, realistic, and reconfigurable environment capable of supporting attack-impact-detection-mitigation experimentation. In this paper, we articulate the need for research testbeds to model various B2G applications broadly by looking at the end-to-end operational hierarchy of the Smart Grid. Finally, the paper not only describes the architecture of the B2G testbed in detail, but also addresses the broad spectrum of B2G resilience research it is capable of supporting based on the smart grid operational hierarchy identified earlier.

Sridhar, Siddharth↗

Analysis of Actual Operating Conditions of an Off-grid Solid Oxide Fuel Cell

Fuel cells have been proposed as ideal replacements for other technologies in remote locations such as Rural Alaska. A number of suppliers have developed systems that might be applicable in these locations, but there are several requirements that must be met before they can be deployed: they must be able to operate on portable fuels, and be able to operate with little operator assistance for long periods of time. This project was intended to demonstrate the operation of a 5 kW fuel cell on propane at a remote site (defined as one without access to grid power, internet, or cell phone, but on the road system). A fuel cell was purchased by the National Park Service for installation in their newly constructed visitor center at Exit Glacier in the Kenai Fjords National Park. The DOE participation in this project as initially scoped was for independent verification of the operation of this demonstration. This project met with mixed success. The fuel cell has operated over 6 seasons at the facility with varying degrees of success, with one very good run of about 1049 hours late in the summer of 2006, but in general the operation has been below expectations. There have been numerous stack failures, the efficiency of electrical generation has been lower than expected, and the field support effort required has been far higher than expected. Based on the results to date, it appears that this technology has not developed to the point where demonstrations in off road sites are justified.

30 DIRECT ENERGY CONVERSION↗

Voltage Regulation with Customer-Sited Resources

This presentation provides a high-level overview of the simulation of feeder operations with advanced inverter grid support functions to understand operational and customer curtailment impacts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wireless Sensor Network for Electric Transmission Line Monitoring

Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and cost effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications. On such a platform, it has been demonstrated in this project that wireless monitoring units can effectively deliver real-time transmission line power flow information for less than $500 per monitor. The data delivered by such a monitor has during the course of the project been integrated with a national grid situational awareness visualization platform developed by Oak Ridge National Laboratory. Novel vibration energy scavenging methods based on piezoelectric cantilevers were also developed as a proposed method to power such monitors, with a goal of further cost reduction and large-scale deployment. Scavenging methods developed during the project resulted in 50% greater power output than conventional cantilever-based vibrational energy scavenging devices typically used to power smart sensor nodes. Lastly, enhanced and new methods for electromagnetic field sensing using multi-axis magnetometers and infrared reflectometry were investigated for potential monitoring applications in situations with a high density of power lines or high levels of background 60 Hz noise in order to isolate power lines of interest from other power lines in close proximity. The goal of this project was to investigate and demonstrate the feasibility of using small form factor, highly optimized, low cost, low power, non-contact, wireless electric transmission line monitors for delivery of real-time, independent power line monitoring for the US power grid. The project was divided into three main types of activity as follows; (1) Research into expanding the range of applications for non-contact power line monitoring to enable large scale low cost sensor network deployments (Tasks 1, 2); (2) Optimization of individual sensor hardware components to reduce size, cost and power consumption and testing in a pilot field study (Tasks 3,5); and (3) Demonstration of the feasibility of using the data from the network of power line monitors via a range of custom developed alerting and data visualization applications to deliver real-time information to federal agencies and others tasked with grid reliability (Tasks 6,8).

24 POWER TRANSMISSION AND DISTRIBUTION↗

InterGraph-CPS: A Graph-Theoretic Approach to Characterize Cross-Domain Cyber-Physical Interdependencies and Uncertainties in Electric Grid Systems for Improved Decision-Making in Operation and Response

Critical infrastructure systems such as the electric grid are increasingly cyber-physical; yet, despite the cyber-physical characteristics of critical infrastructure systems, the physical process system and communication/control network system are traditionally analyzed in siloes. As these systems become more cyber-physical, it is crucial that models and methods are available to assess the cyber physical system (CPS) interdependencies, characteristics, and event propagation for improved planning, operation, and response. Thus, we proposed an integrated structural and temporal CPS interdependency analysis framework, InterGraph-CPS, that provides insight into the CPS function during normal operation as well as disturbances. This integrated structural and temporal interdependency framework is uniquely designed for assessing CPSs by account for the challenges of analyzing cyber and physical data streams together due to data availability, data type, and time scale differences. By leveraging both structural (e.g., graph analysis) and temporal (e.g., data analytics) techniques, different CPS behaviors and configurations can be accounted for.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EV Hosting Capacity Analysis on Distribution Grids: Preprint

Increasing electric vehicle (EV) charging loads can increase the magnitude and duration of conventional peaks in demand profiles and even shift them significantly, causing operational violations in the distribution grid. It is important to develop tools to quantify the impacts of injecting large number of EV charging loads and determine the available capacity of the existing distribution feeder for the safe operation of the grid. Such tools would enable utilities to better prepare for grid operations in the near future while exploring the impact and effectiveness of strategies such as peak pricing and smart charging in managing these loads. This paper evaluates the hosting capacity of some real-world feeders to accommodate EV charging loads, including extreme fast-charging (xFC) options.

47 OTHER INSTRUMENTATION↗

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗