SEARCH · Engineering Papers
Results for “grid management”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Enhanced Large-Signal Stability Method for Grid-Forming Inverters During Current Limiting: Preprint
Grid-forming (GFM) inverters are a promising technology for the widespread integration of renewable energy sources in future power systems. As a key element of GFM inverter control, the primary controller governs the internal reference voltage and angle. During contingencies in the grid---such as faults, voltage drops, or frequency and phase jumps---an inverter can be forced into a current-limiting mode of operation modulating inverter dynamics, and, as a result, it is prone to losing synchronism with the grid. In this paper, we propose a novel GFM primary control method with an additional synchronization term that naturally activates during contingencies to improve the dynamic response. The method allows the inverter to remain synchronized with the grid, which improves the inverter's dynamic behavior both during and after current-limiting grid conditions and enhances grid support, including voltage support using full current capacity. The method is demonstrated for voltage, frequency, and phase jumps both in a single-machine-to-infinite-bus and a network-wide electromagnetic transient simulation of the IEEE 14-bus system with 5 GFM inverters. The simulations provide insights into the proposed synchronization method and confirm the high potential of the method, which robustly secures synchronism under severe contingencies.
PFLOTRAN
PFLOTRAN is a GNU LGPL licensed code that simulates single phase water and multiphase (air, co2, water) flow, energy transport, geochemical reaction and biological reaction in the earth's subsurface environment. The problem may be discretized on structured and unstructured grids. The code is designed to run in parallel on supercomputers and leverages the open source PETSc library for solvers and data structures and open source HDF5 for binary file I/O. See www.pflotran.org and/or doc-dev.pflotran.org for further information. SAND2020-12161 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
Dead Fuel Moisture Content Reanalysis Dataset for California (2000–2020)
This study presents a novel reanalysis dataset of dead fuel moisture content (DFMC) across California from 2000 to 2020 at a 2 km resolution. Utilizing a data assimilation system that integrates a simplified time-lag fuel moisture model with 10-h fuel moisture observations from remote automated weather stations (RAWS) allowed predictions of 10-h fuel moisture content by our method with a mean absolute error of 0.03 g/g compared to the widely used Nelson model, with a mean absolute error prediction of 0.05 g/g. For context, the values of DFMC in California are commonly between 0.05 g/g and 0.30 g/g. The presented product provides gridded hourly moisture estimates for 1-h, 10-h, 100-h, and 1000-h fuels, essential for analyzing historical fire activity and understanding climatological trends. The methodology presented here demonstrates significant advancements in the accuracy and robustness of fuel moisture estimates, which are critical for fire forecasting and management.
Managing Cyber Supply Chain Risk for Renewable Energy Technologies
On July 1, 2021, the U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) hosted a virtual workshop facilitated by the National Renewable Energy Laboratory (NREL). Cybersecurity supply chain experts, researchers, and leaders in government and industry came together to share information on current and future challenges in securing emerging technologies and technical architecture. From a cybersecurity perspective, we need to move from a cybersecurity approach that focuses principally on legacy asset owners to one that incorporates more emphasis on end-point device manufacturers and third-party integrators. Cybersecurity for the global digital supply chain for manufacturers of consumer end-point devices—such as smart solar inverters and smart electric vehicle (EV) chargers—will be critical to the future cyber health of the grid.
Inverse reinforcement learning control for building energy management
Reinforcement learning (RL) based control is widely considered a promising approach in building automation and control as it has demonstrated the potential to deal with complex objectives in adjacent domains like robotics, autonomous vehicles, gaming applications, and advertisement recommendations. When applied to any environment, model-free RL learns to improve its control performance over time without requiring a control model, by receiving and then analyzing feedback from the building environment after each control action. Operational objectives are becoming increasingly complex through the simultaneous consideration of thermal comfort, carbon emissions, grid services, and indoor air quality. In this context, conventional rule-based control approaches are proving sub-optimal, mostly heuristic, and inadequate. The model-free and self learning nature of RL appears promising and attractive as it may address the scalability issues associated with advanced control approaches. However, it suffers from long training times and unstable control behavior during the early stages of its learning process, which makes it unsuitable to be applied directly to buildings. This paper addresses these issues using an inverse reinforcement learning approach (IRL), a technique utilized to learn the objective of a controller agent which is considered an expert in its respective domain. Here, we consider a rule-based control as the expert demonstrator. IRL is different from a direct imitation (i.e., direct mapping of states to actions) of control actions as it tries to find the underlying intent of an expert's policy, providing the controller with a better-generalized policy for unseen states or environments with slightly different dynamics. This approach propels the RL controller's policy to levels similar to or better than that of a rule-based policy before it starts learning by interacting with the building. This makes RL for building energy management applications more practical as it prevents the erratic and exploratory behavior in the initial training period, simultaneously speeding up the learning process when compared to applying an untrained RL agent directly to a building environment.
Machine learning surrogate of physics-based building-stock simulator for end-use load forecasting
Building energy models are used to simulate heat and mass transfer and estimate end-use load in buildings. With the proliferation of solar photovoltaics on residential and commercial buildings, increasingly, buildings are expected to provide grid services, for which accurate and computationally efficient building energy simulations and end-use load prediction are imperative. Existing building energy simulation tools, however, have significant computational overhead that make them less practical in real-time deployment for optimization, design, uncertainty quantification and control in building energy management systems. Here this article presents a data-driven machine learning model based on light gradient boosting method (LightGBM) as a surrogate for a physics-based simulator for residential buildings to predict end-use load. The machine learning based surrogate model accounts for time-series related variables, seasonality and trend component of end-use load, and history of end-use load. The accuracy of the surrogate model is assessed on the prediction of the load profiles of 100 different houses in Cook County, Illinois, USA. The LightGBM surrogate model is shown to reduce the root-mean-squared error by 53% relative to a reference decision tree (DT) based model reported previously in the literature. Moreover, the model predicts the load spikes and high-ramp rate events throughout the year which are often the Achilles heel of other models in the literature. The machine learning based surrogate model is demonstrated to be computationally efficient, with a ten-fold reduction in the computational time compared to a physics-based building energy simulation, and suitable for uncertainty analysis and real-time control of building characteristics in response to uncertainty.
Energy Storage Sizing, Placement and Valuation for Distribution Networks
SAND2023-05682O The Energy Storage Sizing, Placement, and Valuation for Distribution software allows a user to simulate sizing, placement, and operation of one or more storage assets on a distribution grid. Among its features are measuring differences to determine the best combinations, and options for configuring and comparing results. This new simulation capability leverages the Open Distribution System Simulator and the Hierarchical Engine for Large-scale Infrastructure Co-Simulation (HELICS). Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
ZFP: A compressed array representation for numerical computations
HPC trends favor algorithms and implementations that reduce data motion relative to FLOPS. We investigate the use of lossy compressed data arrays in place of traditional IEEE floating point arrays to store the primary data of calculations. Simulation is fundamentally an exercise in controlled approximation, and error introduced by finite-precision arithmetic (or lossy compression) is just one of several sources of error that need to be managed to ensure sufficient accuracy in a computed result. We describe ZFP, a compressed numerical format designed for in-memory storage of multidimensional arrays, and summarize theoretical results that demonstrate that the error of repeated lossy compression can be bounded and controlled. Furthermore, we establish a relationship between grid resolution and compression-induced errors and show that, contrary to conventional floating point, ZFP reduces finite-difference errors with finer grids. We present example calculations that demonstrate data reduction by 4x or more with negligible impact on solution accuracy. Our results further demonstrate several orders-of-magnitude increase in accuracy using ZFP over IEEE floating point and Posits for the same storage budget.
Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)
To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.
Analysis and design of ion thrusters for large space systems
This study undertakes the analysis and conceptual design of a 0.5 Newton electrostatic ion thruster suitable for use on large space system missions in the next decade. Either argon or xenon gas shall be used as propellant. A 50 cm diameter discharge chamber was selected to meet stipulated performance goals. The discharge plasma is contained at the boundary by a periodic structure of alternating permanent magnets generating a series of line cusps. Anode strips between the magnets collect Maxwellian electrons generated by a central cathode. Ion extraction utilizes either two or three grid optics at the user's choice. An extensive analysis was undertaken to investigate optics behavior in the high power environment of this large thruster. A plasma bridge neutralizer operating on inert gas provides charge neutralizing electrons to complete the design. The resulting conceptual thruster and the necessary power management and control requirements are described.
Validation of the Version 1 NOAA/NASA Pathfinder Sea Surface Temperature Data Set
A high-resolution, global satellite-derived sea surface temperature (SST) data set called Pathfinder, from the Advanced Very High Resolution Radiometer (AVHRR) aboard the NOAA Polar Orbiters, is available from the Jet Propulsion Laboratory Physical Oceanography Distributed Active Archive Center (JPL PO.DAAC). Suitable for research as well as education, the Pathfinder SST data set is a result of a collaboration between the National Oceanographic and Atmospheric Administration (NOAA), the National Aeronautics and Space Administration (NASA) and investigators at several universities. NOAA and NASA are the sponsors of the Pathfinder Program, which takes advantage of currently archived Earth science data from satellites. Where necessary, satellite sensors have been intercalibrated, algorithms improved and processing procedures revised, in order to produce long time-series, global measurements of ocean, land and atmospheric properties necessary for climate research. Many Pathfinder data sets are available to researchers now, nearly a decade before the first launch of NASA's Earth Observing System (EOS). The lessons learned from the Pathfinder programs will facilitate the processing and management of terabytes of data from EOS. The Oceans component of Pathfinder has undertaken to reprocess all Global Area Coverage (GAC) data acquired by the 5-channel AVHRRs since 1981. The resultant data products are consistent and stably calibrated [Rao, 1993a, Rao, 1993b, Brown et al., 1993], Earth-gridded SST fields at a variety of spatial and temporal resolutions.
A Framework for Orbital Performance Evaluation in Distributed Space Missions for Earth Observation
Distributed Space Missions (DSMs) are gaining momentum in their application to earth science missions owing to their unique ability to increase observation sampling in spatial, spectral and temporal dimensions simultaneously. DSM architectures have a large number of design variables and since they are expected to increase mission flexibility, scalability, evolvability and robustness, their design is a complex problem with many variables and objectives affecting performance. There are very few open-access tools available to explore the tradespace of variables which allow performance assessment and are easy to plug into science goals, and therefore select the most optimal design. This paper presents a software tool developed on the MATLAB engine interfacing with STK, for DSM orbit design and selection. It is capable of generating thousands of homogeneous constellation or formation flight architectures based on pre-defined design variable ranges and sizing those architectures in terms of predefined performance metrics. The metrics can be input into observing system simulation experiments, as available from the science teams, allowing dynamic coupling of science and engineering designs. Design variables include but are not restricted to constellation type, formation flight type, FOV of instrument, altitude and inclination of chief orbits, differential orbital elements, leader satellites, latitudes or regions of interest, planes and satellite numbers. Intermediate performance metrics include angular coverage, number of accesses, revisit coverage, access deterioration over time at every point of the Earth's grid. The orbit design process can be streamlined and variables more bounded along the way, owing to the availability of low fidelity and low complexity models such as corrected HCW equations up to high precision STK models with J2 and drag. The tool can thus help any scientist or program manager select pre-Phase A, Pareto optimal DSM designs for a variety of science goals without having to delve into the details of the engineering design process.
Influence of SMAP Soil Moisture Retrieval Assimilation on Runoff Estimation Across South Asia
This study was designed to characterize and quantify the influence of surface soil moisture assimilation on estimated runoff (surface flow and baseflow) and hydraulically-routed streamflow across three large river basins in South Asia that are at risk of impending water stress. Soil Moisture Active Passive (SMAP) surface soil moisture retrievals were assimilated into the Noah-MP land surface model. The gridded runoff was hydraulically routed to obtain volumetric streamflow values for a river network using a runoff routing module (Hydrological Modeling and Analysis Platform, HyMAP). The open loop (OL, model-only) and data assimilated (DA, includes soil moisture retrieval assimilation) Noah-MP runoff estimates highlighted the improvements in estimated total runoff across irrigated areas. Soil moisture assimilation impacted baseflow more relative to surface runoff. The HyMAP-based OL and DA streamflow generally underestimated the streamflow at upstream stations and overestimated the streamflow at downstream stations within the Indus basin due to missing physics related to reservoir operations. For stations located in the Ganges–Brahmaputra basins, the OL and DA estimation performance varied. The OL and DA results showed that the assimilation of soil moisture retrievals improves gridded runoff and volumetric streamflow across irrigated areas. Considerable relative change in streamflow (>70% increase in magnitude relative to OL) is noted after assimilation across the highly irrigated lower Indus basin and high precipitation regions in Bangladesh. Improving the modeling system’s representativeness of ground conditions via inclusion of water management information could improve large-scale streamflow modeling across South Asia.
Valuing the Future Electric Grid: A Bid-Based Approach
Energy storage resources (ESRs) and other zero marginal cost (ZMC) resources have unique characteristics that are not fully captured in today’s electricity planning and operations modeling tools. Because the modeling assumptions used in these tools are simplified approximations of how operations and investment decisions occur in the real-world, accurately representing cost and operational characteristics are key for determining how these resources impact price formation. Questions such as—Where should we build new transmission? Will a small modular reactor earn enough revenue to participate in the future electric grid? Is retrofitting a coal plant with carbon capture technology economically feasible?—all require accurate electricity prices, which aren’t available from today’s electricity planning and operations modeling tools. As an example, production cost models (PCMs) are heavily utilized tools that determine the cost and reliability of the electric system. However, as PCMs were developed to help thermal generators manage their fuel inventories, production cost modeling is largely based on fuel prices. Because ESRs do not incur fuel costs, they are often modeled as ZMC resources. In reality, ESRs incur opportunity costs as well as technology-specific (degradation) costs that are non-trivial to calculate but are important for price formation. In this research, we identify options to incorporate more realistic opportunity and degradation costs in ESR bidding algorithms. Expanding available bidding assumptions allows energy system modelers to develop more accurate economic valuations for ESRs, leading to more accurate price formation from leading energy system modeling tools.
Identifying Key Drivers of Wildfires in the Contiguous US Using Machine Learning and Game Theory Interpretation
Abstract Understanding the complex interrelationships between wildfire and its environmental and anthropogenic controls is crucial for wildfire modeling and management. Although machine learning (ML) models have yielded significant improvements in wildfire predictions, their limited interpretability has been an obstacle for their use in advancing understanding of wildfires. This study builds an ML model incorporating predictors of local meteorology, land‐surface characteristics, and socioeconomic variables to predict monthly burned area at grid cells of 0.25° × 0.25° resolution over the contiguous United States. Besides these predictors, we construct and include predictors representing the large‐scale circulation patterns conducive to wildfires, which largely improves the temporal correlations in several regions by 14%–44%. The Shapley additive explanation is introduced to quantify the contributions of the predictors to burned area. Results show a key role of longitude and latitude in delineating fire regimes with different temporal patterns of burned area. The model captures the physical relationship between burned area and vapor pressure deficit, relative humidity (RH), and energy release component (ERC), in agreement with the prior findings. Aggregating the contribution of predictor variables of all the grids by region, analyses show that ERC is the major contributor accounting for 14%–27% to large burned areas in the western US. In contrast, there is no leading factor contributing to large burned areas in the eastern US, although large‐scale circulation patterns featuring less active upper‐level ridge‐trough and low RH two months earlier in winter contribute relatively more to large burned areas in spring in the southeastern US.
Development of a DC Distribution Testbed for High-Power EV Charging
This paper explores the design and implementation of a power hardware-in-the-loop (P-HIL) setup for DC distribution infrastructure integrated with high-power charging (HPC) of electric vehicles (EVs), DC loads, and sources. The utilization of DC distribution holds significant potential for enhancing the operation of a HPC station architecture. However, there are challenges establishing a DC charging hub including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products to evaluate different use cases at rated power and voltage levels. The developed P-HIL setup features a dedicated DC charging hub, DC-coupled chargers, DC loads/sources, DC protection, and a communication architecture. The integrated P-HIL system provides a versatile testing environment to address technology and interoperability gaps and implements a smart energy management system (SEMS). This platform enables comprehensive and robust testing of COTS devices, charger prototypes, SEMS controllers and protection schemes, which together will accelerate transition to EVs at scale. The setup is tested for various use-cases at full-scale, integrating 950 V DC bus voltage, 660 kW grid-tied inverter, 150 kW COTS charger, and 100 kW energy storage system within an open-source SEMS platform.
Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model
The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.