Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Neutron Imaging Using Organic Glass Scintillators

In this work, we develop of a compact neutron imaging system based on organic glass scintillator and silicon photomultiplier arrays. The recently developed organic glass scintillator has excellent neutron and gamma-ray detection efficiency and exhibits pulse shape discrimination capability that is nearly as good as current state-of-the-art materials such as trans-stilbene. We have cast and characterized 6 mm by 6 mm by 50 mm bars of organic glass in our laboratory. When coupled to a silicon photomultiplier array, these bars demonstrated better energy and timing resolution than the stilbene organic scintillator. Here, this performance makes organic glass an ideal material for a compact neutron imaging system, which must resolve neutron scatter events on a sub-nanosecond time scale. We have demonstrated neutron imaging with bars of organic glass scintillator coupled to arrays of silicon photomultipliers. Additional bars of organic glass will be implemented into the system to improve the efficiency and imaging performance. The resulting system will be demonstrated using 252 Cf and PuBe neutron sources in our laboratory. In addition, we will compare imaging performance to other compact neutron imaging systems that exist in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Total-Ionizing-Dose Resistant Data Storing Technique for NAND Flash Memory

This paper describes a new non-charge-based data storing technique in NAND flash memory called watermark that encodes read-only data in the form of physical properties of flash memory cells. Unlike traditional charge-based data storing method in flash memory, the proposed technique is resistant to total ionizing dose (TID) effects. To evaluate its resistance to irradiation effects, we analyze data stored in several commercial single-level-cell (SLC) flash memory chips from different vendors and technology nodes. These chips are irradiated using a Co-60 gamma-ray source array for up to 100 krad(Si) at Sandia National Laboratories. Experimental evaluation performed on a flash chip from Samsung shows that the intrinsic bit error rate (BER) of watermark increases from 0.8% for TID = 0 krad(Si) to 1% for TID = 100 krad(Si). Conversely, the BER of charge-based data stored on the same chip increases from 0% at TID = 0 krad(Si) to 1.5% at TID = 100 krad(Si). Overall, the results imply that the proposed technique may potentially offer significant improvements in data integrity relative to traditional charge-based data storage for very high radiation (TID > 100 krad(Si)) environments. These gains in data integrity relative to the charge-based data storage are useful in radiation-prone environments, but they come at the cost of increased write times and higher BERs before irradiation.

36 MATERIALS SCIENCE↗

Onset of Fogging and Degradation in Polyvinyl Toluene-Based Scintillators

Plastic-based gamma-ray detector materials such as polyvinyl toluene (PVT) occasionally suffer from loss of optical light transmission due to internal defects or “fogging” when exposed to some environmental conditions over time. Fogging results in reduced scintillation light propagated to the photomultiplier tube for collection. Investigations of the physical cause of these defects and their associated environmental conditions are ongoing. The goal of this work was to characterize the signs and effects of fogging over a simulated 22-year lifespan of the PVT in outdoor environments. Here, two potential mitigation methods were also evaluated, and one successfully mitigated the phenomena.

36 MATERIALS SCIENCE↗

Radiation-Induced Error Mitigation by Read-Retry Technique for MLC 3-D NAND Flash Memory

Here, we have evaluated the Read-Retry (RR) functionality of the 3-D NAND chip of multilevel-cell (MLC) configuration after total ionization dose (TID) exposure. The RR function is typically offered in the high-density state-of-the-art NAND memory chips to recover data once the default memory read method fails to correct data with error correction codes (ECCs). In this work, we have applied the RR method on the irradiated 3-D NAND chip that was exposed with a Co-60 gamma-ray source for TID up to 50 krad (Si). Based on our experimental evaluation results, we have proposed an algorithm to efficiently implement the RR method to extend the radiation tolerance of the NAND memory chip. Our experimental evaluation shows that the RR method coupled with ECC can ensure data integrity of MLC 3-D NAND for TID up to 50 krad (Si).

3-D NAND↗

Total-Ionizing-Dose Effects on Long-term Data Retention Characteristics of Commercial 3-D NAND Memories

This article evaluates the data retention characteristics of irradiated multi-level cell (MLC) 3-D NAND flash memories. We irradiate the memory chips by a Co-60 gamma-ray source for up to 50 krad(Si) and then write a random data pattern on the irradiated chip to find its retention characteristics. The experimental results show that the data retention property of the irradiated chips is significantly degraded compared to the un-irradiated ones. We evaluate two independent strategies to improve the data retention characteristics of the irradiated chips. Furthermore, the first method involves high-temperature annealing of the irradiated chip while the second method suggests pre-programming the memory modules before deploying them in radiation-prone environments.

3-D NAND flash↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

MOLLER Spectrometer Magnet Design With Measured Mechanical Properties of Irradiated S2-Glass Reinforced Cyanate Ester Resin at Elevated Temperature

Here, the aim of this study was to retire the risk of maintaining the integrity of S2-glass reinforced CTD-403 (a cyanate ester resin) that is exposed to radiation and elevated temperature over the life of the measurement of a lepton–lepton electroweak reaction (MOLLER) experiment in experimental Hall A at Jefferson Lab, Newport News, VA. In this article, the shear strength and flexural modulus of irradiated S2-glass reinforced CTD-403 specimens were measured at 65 °C (the magnets are to operate at less than 65 °C) under two scenarios: vacuum and gaseous nitrogen. The testing method is the short-beam shear (SBS) test according to ASTM D2344. The specimens were exposed to neutrons and gamma rays up to 124 MGy. The results show that specimens have excellent resistance against radiation, only 23% degradation of apparent shear strength with 124 MGy at 65 °C under vacuum. At the highest dose areas of the coils, tungsten plates are used to reduce the radiation dose to the resin system. The conclusion is that S2-glass reinforced CTD-403 is well-suited for electrical insulation of MOLLER magnets.

36 MATERIALS SCIENCE↗

Fast Neutron Irradiation of a Multichannel JFET-Based Optical Encoder

Modern electrical components are susceptible to damage from high levels of radiation and extreme temperatures found near reactors in terrestrial nuclear power plants and in aerospace applications. Radiation-hardened electronics are being developed, largely for the aerospace industry, but they sometimes rely on application-specific, small-batch semiconductor fabrication processes. These processes tend to be prohibitively expensive to develop and maintain outside major industrial facilities or governmental agencies. Recently, commercially available, nonradiation-rated junction-gate field-effect transistors (JFETs) were shown to maintain their functionality at gamma doses exceeding 1 MGy, suggesting that nonrated, commercially available electrical components could be used to develop systems that are tolerant to ionizing radiation. However, gamma ray survival is not indicative of neutron dose survival, and few studies characterize JFETs under neutron irradiation. To address this knowledge gap, a JFET-based analog multiplexer and optical pulsewidth modulation (PWM) encoder was developed and irradiated using a 252 Cf source to 1.6×10 13 n/cm 2 . The multiplexed optical encoder (MOE) system maintained functionality throughout testing and showed little evidence of radiation effects. These results indicate that circuitry tolerant to fast neutron damage can be developed using low-cost, nonradiation-rated, commercially available JFETs, which could provide a lower production cost alternative to specialized semiconductor processes when designing and building electronics better able to survive neutron irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiological Source Term Estimation and Isotopic Identification with Parallel Log Domain Particle Filters

This paper presents a parallel log-domain particle filtering algorithm combined with gamma spectrum unfolding to perform localization, identification, and evaluation of multiple point sources of various isotopes in an environment with attenuating obstacles. The method uses sets of precomputed attenuation kernels that map the attenuation characteristics of the environment. These kernels are specific to the energy level of a photopeak of interest. The spectral measurements are deconvolved into count measurements of each photopeak. These count measurements are fed into a set of parallel particle filters using attenuation kernels computed for that photopeak’s energy level. The individual regularized particle filters perform all likelihood calculations in the logarithmic domain to mitigate the effects of particle degeneracy. The output of each particle filter is combined to estimate which isotopes are present as well as their positions and strengths. The performance of the algorithm is characterized in a lab-scale environment using a mobile robot equipped with a gamma ray spectrometer in the presence of up to three different radioactive isotopes simultaneously. The sources were localized to within 10 cm, and their strengths were estimated within 10% of their true values. Furthermore, the isotopes were all correctly identified, and no spurious sources were reported.

42 ENGINEERING↗

CAMIS: A Cylindrical Active Mask Imaging System

Detecting and locating radiological and nuclear materials at distances of 10 m or more in urban and cluttered environments continues to pose challenges in nuclear security and proliferation detection. Previous approaches have focused on large-area radiation imaging using planar configurations of detectors and passive masks. However, these approaches suffer from limitations such as limited field-of-view (FOV) and reduced detection efficiency due to absorption in the mask. To address these limitations, we have developed the cylindrical active mask imaging system (CAMIS). This system comprises 128 NaI(Tl) (10 cm)3 detectors. These detectors are arranged in a cylindrical configuration, enabling gamma-ray imaging with a full 360° azimuthal FOV. The active mask elements within the system are arranged in a pseudorandom configuration, providing unique encoding for all incident directions within the FOV. CAMIS offers an effective detection area of approximately 1 m2 across the entire 360° FOV in the horizontal plane, achieving a mean angular resolution of 10.9° in the azimuthal direction and 12.9° in the polar direction measured by taking the full-width at half-maximum (FWHM) of a cross-section at the maximum reconstructed intensity.

Lamb, C↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Multiple chiral bands in $^{137}$Nd

Two new bands have been identified in 137 Nd from a high-statistics JUROGAM II gamma-ray spectroscopy experiment. Constrained density functional theory and particle rotor model calculations are used to assign configurations and investigate the band properties, which are well described and understood. It is demonstrated that these two new bands can be interpreted as chiral partners of previously known three-quasiparticle positive- and negative-parity bands. The newly observed chiral doublet bands in 137 Nd represent an important support to the existence of multiple chiral bands in nuclei. Overall, the present results constitute the missing stone in the series of Nd nuclei showing multiple chiral bands, which becomes the most extended sequence of odd-even and even-even nuclei presenting multiple chiral bands in the Segre chart.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for double-beta decay of $$\mathrm {^{130}Te}$$ to the $$0^+$$ states of $$\mathrm {^{130}Xe}$$ with CUORE

Abstract The CUORE experiment is a large bolometric array searching for the lepton number violating neutrino-less double beta decay ( $$0\nu \beta \beta $$ 0 ν β β ) in the isotope $$\mathrm {^{130}Te}$$ 130 Te . In this work we present the latest results on two searches for the double beta decay (DBD) of $$\mathrm {^{130}Te}$$ 130 Te to the first $$0^{+}_2$$ 0 2 + excited state of $$\mathrm {^{130}Xe}$$ 130 Xe : the $$0\nu \beta \beta $$ 0 ν β β decay and the Standard Model-allowed two-neutrinos double beta decay ( $$2\nu \beta \beta $$ 2 ν β β ). Both searches are based on a 372.5 kg $$\times $$ × yr TeO $$_2$$ 2 exposure. The de-excitation gamma rays emitted by the excited Xe nucleus in the final state yield a unique signature, which can be searched for with low background by studying coincident events in two or more bolometers. The closely packed arrangement of the CUORE crystals constitutes a significant advantage in this regard. The median limit setting sensitivities at 90% Credible Interval (C.I.) of the given searches were estimated as $$\mathrm {S^{0\nu }_{1/2} = 5.6 \times 10^{24} \, \mathrm {yr}}$$ S 1 / 2 0 ν = 5.6 × 10 24 yr for the $${0\nu \beta \beta }$$ 0 ν β β decay and $$\mathrm {S^{2\nu }_{1/2} = 2.1 \times 10^{24} \, \mathrm {yr}}$$ S 1 / 2 2 ν = 2.1 × 10 24 yr for the $${2\nu \beta \beta }$$ 2 ν β β decay. No significant evidence for either of the decay modes was observed and a Bayesian lower bound at $$90\%$$ 90 % C.I. on the decay half lives is obtained as: $$\mathrm {(T_{1/2})^{0\nu }_{0^+_2} > 5.9 \times 10^{24} \, \mathrm {yr}}$$ ( T 1 / 2 ) 0 2 + 0 ν > 5.9 × 10 24 yr for the $$0\nu \beta \beta $$ 0 ν β β mode and $$\mathrm {(T_{1/2})^{2\nu }_{0^+_2} > 1.3 \times 10^{24} \, \mathrm {yr}}$$ ( T 1 / 2 ) 0 2 + 2 ν > 1.3 × 10 24 yr for the $$2\nu \beta \beta $$ 2 ν β β mode. These represent the most stringent limits on the DBD of $$^{130}$$ 130 Te to excited states and improve by a factor $$\sim 5$$ ∼ 5 the previous results on this process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phenomenology of bubble size distributions in a first-order phase transition

In a cosmological first-order phase transition (FOPT), the true and false vacuum bubble radius distributions are not expected to be monochromatic, as is usually assumed. Consequently, Fermi balls (FBs) and primordial black holes (PBHs) produced in a dark FOPT will have extended mass distributions. We show how gravitational wave (GW), microlensing and Hawking evaporation signals for extended bubble radius/mass distributions deviate from the case of monochromatic distributions. The peak of the GW spectrum is shifted to lower frequencies, and the spectrum is broadened at frequencies below the peak frequency. Thus, the radius distribution of true vacuum bubbles introduces another uncertainty in the evaluation of the GW spectrum from a FOPT. The extragalactic gamma-ray signal at AMEGO-X/e-ASTROGAM from PBH evaporation may evince a break in the power-law spectrum between 5 MeV and 10 MeV for an extended PBH mass distribution. Optical microlensing surveys may observe PBH mass distributions with average masses below 10 -10 M ⊙ , which is not possible for monochromatic mass distributions. This expands the FOPT parameter space that can be explored with microlensing.

Marfatia, Danny [Univ. of Hawaii at Manoa, Honolul↗

Evaluation of Compton suppression for enhancing trace element identification in neutron activation analysis of reference materials

Neutron activation analysis (NAA) is a powerful technique for identifying and quantifying trace elements in materials. However, challenges such as high dead times, spectral interferences, and high Compton continuum often arise. This study employs a Compton suppression system (CSS) to enhance NAA sensitivity by reducing the Compton continuum, thereby improving the peak-to-Compton ratio. National Institute of Standards and Technology certified reference materials 1632d, 1633c, and Canadian National Research Council TORT-1 were irradiated in a thermal and epithermal neutron flux under various irradiation, decay and counting times and analyzed using high-resolution gamma-ray spectroscopy with and without Compton suppression. The reduction factor was calculated to evaluate the effectiveness of the CSS, demonstrating significant background reduction and improved detection limits for trace elements. Additional experiments with a 137Cs point source demonstrated the impact of detector-source geometry on system performance, showing a decrease in the reduction factor as the source was moved further from the NaI detector. An optimum distance between the source and HPGe detector was observed, yielding the highest peak-to-Compton ratio. The results highlight the CSS's ability to minimize spectral interference and enhance elemental identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Channeling and radiation experiments at SLAC

Since 2014, a SLAC-Aarhus-Ferrara-CalPoly collaboration augmented by members of ANL and MIT has performed electron and positron channeling experiments using bent silicon crystals at the SLAC End Station A Test Beam as well as the FACET accelerator test facility. These experiments have revealed a remarkable channeling efficiency of about 24% under our conditions. Volume reflection is even more efficient with almost the whole beam taking part in the reflection process. A positron experiment demonstrated quasi-channeling oscillations for the first time at high beam energy. In our most recent experiment we measured the spectrum of gamma radiation for crystal orientations covering channeling and volume reflection. We report this series of experiments supports the development of more advanced crystalline devices capable e.g. of producing narrow-band gamma rays with electron beams or studying the interaction of the electrons with the wakefields generated in the crystal at high beam intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Geant4 based positron beam source (GPos) v1.0

GPos is a software that was created to determine the properties of positron beams resulting from the interaction of the LBNL BELLA center PetaWatt laser-driven plasma-capillary accelerated electron beam and the atoms of a thin solid target. GPos is written in C++, easily compiled with cmake and the spack package manager, which allows for multi-thread and MPI parallel computing. Its functions expand on the Geant4 toolkit library and allow for propagation of the modelled particles through vacuum drift distances with a focusing element (thin lens approximation). Users can change beam-foil-drift-lens parameters - to adapt GPos to other particle sources and infrastructures - in a simple input file. The code particle data output format, openPMD, which is compatible, for example, with the input of the ECP WarpX project code used to explore the physics of particle acceleration in plasmas. Using GPos in conjunction to WarpX allowed us to test various configurations for designing a high-quality and high-energy positron source at BELLA -required for us to address positron acceleration challenges in the development of future linear colliders. GPos can also be advantageous when tackling the physics of muon sources for future muon colliders as well as for the investigation of positron sources in lower energy regimes for applications like annihilation spectroscopy and astrophysical gamma-ray-bursts.

Pinto de Almeida Amorim, Ligia↗

RadSim: Math, Utility & RTK

This package includes three parts, (1) gov.llnl.math, (2)gov.llnl.utility and (3)gov.llnl.rtk, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The techniques and implementation will be entirely transparent, which will allow for improvements and boutique modifications by future researchers beyond the lifespan of this specific project. The first tool of the package, gov.llnl.math, includes classes and functions to define and perform basic math operations. Some of the example features available in the package include defining statistical distributions and performing algebra and matrix operations, all of which are already accessible on publicly available software packages such as MATLAB and ROOT. The second package gov.llnl.utility includes tools commonly used to enable optimization and readability of various data structures such as Java lists and external xml files. Lastly, the gov.llnl.rtk package includes classes and functions to implement methods commonly used in radiation physics, such as data structures to represent and characterize photon spectra and tools to apply well-defined and published methods to calibrate a given spectra.

Cheung, Hoi Sing↗