Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “focal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Imaging spectrometer technologies for advanced Earth remote sensing

A major requirement of multispectral imaging systems for advanced Earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from Earth Orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s.

Wellman, J. B.↗

A radio-frequency analysis of paraboloidal antennas located near diffracting fences

The cylindrical waves associated with the Sommerfeld solution for a diffracting half-plane are applied in the evaluation of the effects of secondary radiation on the focal-region-fields of paraboloids. A cross-correlation between the computed focal-region-fields and the feed-antenna-fields is then introduced to determine the modified radiation pattern of paraboloidal antennas. The half-plane solution is adapted to estimate the effects of a polygonal fence on 9-meter S-band and 3-meter S- and Ku-band antennas at the Merrit Island, Fl Spacecraft Tracking and Data Network Station.

Schmidt, R. F.↗

Radiation effects in IRAS extrinsic infrared detectors

During the calibration and testing of the Infrared Astronomy Satellite (IRAS) focal plane, it was observed that the extrinsic photoconductor detectors were affected by gamma radiation at dose levels of the order of one rad. Since the flight environment will subject the focal plane to dose levels of this order from protons in single pass through the South Atlantic Anomaly, an extensive program of radiation tests was carried out to measure the radiation effects and to devise a method to counteract these effects. The effects observed after irradiation are increased responsivity, noise, and rate of spiking of the detectors after gamma-ray doses of less than 0.1 rad. The detectors can be returned almost to pre-irradiation performance by increasing the detector bias to breakdown and allowing a large current to flow for several minutes. No adverse effects on the detectors have been observed from this bias boost, and this technique will be used for IRAS with frequent calibration to ensure the accuracy of observations made with the instrument.

Varnell, L.↗

The IRAS telescope

The IRAS telescope is described in terms of its system configuration and physical characteristics, subsystem functions and descriptions, and performance characteristics. The mission and the configuration are reviewed briefly, and the major functional components of the telescope are described, including the focal plane assembly, the optics, the electronics, the cryogenics, and the thermal control. Exploded and cross-sectional views and block diagrams are presented for the telescope system configuration, focal plane assembly, infrared subarray module, optical subsystem, infrared channel data flow, and main cryogen dewar. The telescope physical characteristics are listed. The performance characteristics are listed and discussed, including the spectral response, sensitivity, optical quality, and photometric accuracy. Relative system spectral response curves for the infrared bands are shown.

Irace, W.↗

Space Schmidt telescope

The complete survey takes in 3627 fields, each 4.87 deg in diameter, arranged in a hexagonal pattern superimposed on the celestial equatorial coordinate system. The declination bands are spaced every 3 deg, 20 min. The optical instrument is a folded all-reflecting Schmidt system with an aperture of 0.74 m, a focal length of 2.0 m (f/2.7), a circlar field with a diameter of 4.87 deg, and a limiting image diameter of less than 2 arcsec over the entire field. The detector is an electrographic camera having a photocathode diameter of 170 mm. In discussing the telescope structure, it is pointed out that the optical support system is to be of graphite-epoxy construction. The focal tolerance (the most critical optical tolerance) is to be + or - 12 microns. Regarding contamination control, it is expected that with appropriate design it will be possible to operate in sunlight for observations in a restricted portion of the sky, at least more than 90 deg from the sun, depending on the geometry and reflectivity of the platform or spacecraft configuration.

Wray, J. D.↗

Cooled grating array spectrometer for 0.6-5 microns

A grating spectrometer, designed to illuminate an array of 122 InSb photodiodes with minimum aberrations and maximum speed, has been constructed. The instrument will be used on the 5 meter Hale telescope at Palomar Observatory, and is easily adaptable to telescopes of various focal ratios. A resolving power of 100-1000 can be obtained at wavelengths between 0.6 microns and 5 microns with remotely interchangeable gratings. The spectrometer is sufficiently compact to fit on the 8-inch work surface of a commercially available dewar, and uses simple on-axis spherical and paraboloidal optical elements. The camera mirror produces an f/2.5 beam which, with the 0.2 mm detectors, allows a 3-in. focal-plane aperture on the 5 meter telescope. All rays fall within a 100 microns blur circle at all points along the array. Distortions have been corrected with a tilted field flattening lens in front of the detector.

Nordholt, J. E.↗

A small, battery-operated fluoroscopic system - Lixiscope with X-ray generator

A small, battery-operated X-ray generator has been developed to be used as part of a small-format fluoroscopic system, the Lixiscope (Low Intensity X-ray Imaging Scope). The X-ray generator consists of a grounded rod-anode X-ray tube with a 0.2 mm focal spot and a specially designed, battery-operated, 0 to -80 kV high-voltge supply. Total power consumption is about 10 W. The fine focal spot, in conjunction with the continuously variable X-ray intensity and spectral distribution, helps to extend both the versatility and the performance of the Lixiscope toward a much wider range of terrestrial and spacecraft applications. The complete fluoroscopic system is described, and some examples of possible applications are shown.

Yin, L. I.↗

LANDSAT-4 sensor performance

Preflight and in-orbit sensor and data measurements indicate that TM meets or exceeds most specifications. Measured spectral band edges meet instrument specifications in 12 out of 14 cases; there is ample dynamic range. The signal-to-noise ratio exceeds specifications, except for band 3, channel 4; and band 7 channel 7 is very noisy but still meets specifications. The modulation transfer function of channel 4, band 2, is smaller than specified. Registration errors between the primary focal plane (PFP) and the cold focal plane (CFP) are about 0.75 pixels along-scan and 0.2 pixels across scan. Forward and reverse scan discontinuities, are well within ground-processing capabilities to rectify. Instrument gain variability, up to 7% for band 5, requires use of the internal calibration (IC) system to assure radiometric accuracy. Preliminary applications evaluation of image contents indicates that TM provides much better definition of edges than MSS.

Barker, J. L.↗

High resolution observations of low contrast phenomena from an Advanced Geosynchronous Platform (AGP)

Present technology allows radiometric monitoring of the Earth, ocean and atmosphere from a geosynchronous platform with good spatial, spectral and temporal resolution. The proposed system could provide a capability for multispectral remote sensing with a 50 m nadir spatial resolution in the visible bands, 250 m in the 4 micron band and 1 km in the 11 micron thermal infrared band. The diffraction limited telescope has a 1 m aperture, a 10 m focal length (with a shorter focal length in the infrared) and linear and area arrays of detectors. The diffraction limited resolution applies to scenes of any brightness but for a dark low contrast scenes, the good signal to noise ratio of the system contribute to the observation capability. The capabilities of the AGP system are assessed for quantitative observations of ocean scenes. Instrument and ground system configuration are presented and projected sensor capabilities are analyzed.

Maxwell, M. S.↗

Rapid Test Bed Concentrator (TBC) Alignment Techniques

A new, labor and cost saving method was developed to eliminate the procedure of covering all (220) mirrors and uncovering then one-by-one in sequence to adjust each to the focal plane. This latest method being used to align mirrors of a parabolic solar concentrator utilizes a computer-derived target of discreet images made up of individual mirror reflections on a plane in front of the intended, nominal, focal point. Incorporating this computer technique increases accuracy and gives potential to develop flux distributions required by different receiver designs.

Argoud, M. J.↗

Preliminary Evaluation of Thematic Mapper Image Data Quality

Thematic Mapper (TM) data from Mississippi County, Arkansas, and Webster County, Iowa, were examined for the purpose of evaluating the image data quality of the TM which was launched on board the LANDSAT-4 spacecraft. Preliminary clustering and principal component analysis indicates that the middle infrared and thermal infrared data of TM appear to add significant information over that of the near IR and visible bands of the multispectral scanner data. Moreover, the higher spatial resolution of TM appears to provide better definition of the edges and the within variability of agricultural fields. The geometric performance of TM data, without ground control correction, was found to exceed expectations. The modulation transfer function for the 1.65 m band was found to agree with prelaunch specifications when the effects of the GSFC cubic convolution and the atmosphere were removed. The band to band registration for the bands within the noncooled focal plane was found to be better than specified. However, the middle infrared and thermal infrared, which are on a separate cooled focal plane were found to be misregistered and were significantly worse than prelaunch specifications.

Macdonald, R. B.↗

Seismicity, fault plane solutions, depth of faulting, and active tectonics of the Andes of Peru, Ecuador, and southern Colombia

The long-period P waveforms observed for 17 earthquakes in the Peruvian Andes during 1963-1976 are compared with synthetic waveforms to obtain fault-plane solutions and focal depths. The morphological units of the Peruvian Andes are characterized: coastal plains, Cordillera Occidental, altiplano and central high plateau, Cordillera Oriental, and sub-Andes. The data base and analysis methodology are discussed, and the results are presented in tables, diagrams, graphs, maps, and photographs illustrating typical formations. Most of the earthquakes are shown to occur in the transition zone from the sub-Andes to the Cordillera Oriental under formations of about 1 km elevation at focal depths of 10-38 km. It is suggested that the sub-Andean earthquakes reflect hinterland deformation of a detached fold and thrust belt, perhaps like that which occurred in parts of the Canadian Rockies. From the total crustal shortening evident in Andean morphology and the shortening rate of the recent earthquakes it is estimated that the topography and crustal root of the Andes have been formed during the last 90-135 Myr.

Suarez, G.↗

Optimization of dish solar collectors

Methods for optimizing parabolic dish solar collectors and the consequent effects of various optical, thermal, mechanical, and cost variables are examined. The most important performance optimization is adjusting the receiver aperture to maximize collector efficiency. Other parameters that can be adjusted to optimize efficiency include focal length, and, if a heat engine is used, the receiver temperature. The efficiency maxima associated with focal length and receiver temperature are relatively broad; it may, accordingly, be desirable to design somewhat away from the maxima. Performance optimization is sensitive to the slope and specularity errors of the concentrator. Other optical and thermal variables affecting optimization are the reflectance and blocking factor of the concentrator, the absorptance and losses of the receiver, and, if a heat engine is used, the shape of the engine efficiency versus temperature curve. Performance may sometimes be improved by use of an additional optical element (a secondary concentrator) or a receiver window if the errors of the primary concentrator are large or the receiver temperature is high. Previously announced in STAR as N83-19224

Jaffe, L. D.↗

Imaging spectrometer technologies for advanced earth remote sensing

A major requirement of multispectral imaging systems for advanced earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from earth orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s. Previously announced in STAR as N83-28542

Wellman, J. B.↗

Brief characterization of germanium junction field effect transistors (FETs) at 77, 4, and 1.8 K

In the case of modern infrared focal planes, one of the major problems is related to the noise contribution of the cooled, impedance-matching device used as the preamplifier stage in the detector electronics system. An ideal preamp device should have the low-noise advantages of a buried-channel device and operate isothermally with the low-temperature detector array. The Ge JFET might provide this ideal device. A testing program with Ge JFETs is discussed. It is concluded that germanium JFETs offer an attractive alternative for cryogenic preamplifier designs. They operate well with high transconductance and low noise at LHe temperatures. It is believed that these devices point the way for the development of large, integrated-array, long wavelength, infrared focal planes which incorporate germanium detectors, germanium load resistors, and germanium preamplifiers within the same monolithic structure.

Arentz, R. F.↗

Sensitive observations with the Spacelab 2 infrared telescope

The small helium-cooled infrared telescope (Spacelab IRT) is a multiband instrument capable of highly sensitive observations from space. The experiment consists of a cryogenically cooled, very well baffled telescope with a ten channel focal plane array. During the Spacelab 2 flight of the Space Shuttle, this instrument will make observations between 5 and 120 micron wavelength that will be background limited by the expected zodiacal emission. Design considerations necessitated by this level of performance are discussed in this paper. In particular, the operation of a very sensitive focal plane array in the space environment is described. The Spacelab IRT will be used to map the extended, low-surface brightness celestial emission. During the seven day length of the mission better than 70 percent sky coverage is expected. The instrument will also be used to measure the infrared contamination environment of the Space Shuttle. This information will be important in the development of the next generation of infrared astronomical instruments. The performance of the Spacelab IRT, in particular its sensitivity to the contamination environment is detailed.

Young, E. T.↗

A comparison between GO/aperture-field and physical-optics methods for offset reflectors

Both geometrical optics (GO)/aperture-field and physical-optics (PO) methods are used extensively in the diffraction analysis of offset parabolic and dual reflectors. An analytical/numerical comparative study is performed to demonstrate the limitations of the GO/aperture-field method for accurately predicting the sidelobe and null positions and levels. In particular, it is shown that for offset parabolic reflectors and for feeds located at the focal point, the predicted far-field patterns (amplitude) by the GO/aperture-field method will always be symmetric even in the offset plane. This, of course, is inaccurate for the general case and it is shown that the physical-optics method can result in asymmetric patterns for cases in which the feed is located at the focal point. Representative numerical data are presented and a comparison is made with available measured data.

Rahmat-Samii, Y.↗

Landsat-4 sensor performance

Preflight and in-orbit sensor and data measurements indicate that TM meets or exceeds most specifications. Measured spectral band edges meet instrument specifications in 12 out of 14 cases; there is ample dynamic range. The signal-to-noise ratio exceeds specifications, except for band 3, channel 4; and band 7 channel 7 is very noisy but still meets specifications. The modulation transfer function of channel 4, band 2, is smaller than specified. Registration errors between the primary focal plane (PFP) and the cold focal plane (CFP) are about 0.75 pixels along-scan and 0.2 pixels across scan. Forward and reverse scan discontinuities are well within ground-processing capabilities to rectify. Instrument gain variability, up to 7 percent for band 5, requires use of the internal calibration (IC) system to assure radiometric accuracy. Preliminary applications evaluation of image contents indicates that TM provides much better definition of edges than MSS.

Barker, J. L.↗