Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “equivalence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Package Equivalent Reactor Networks as Reduced Order Models for Use with CAPE-OPEN Compliant Simulation

Engineering simulations of coal gasifiers are typically performed using computational fluid dynamics (CFD) software, where a 3-D representation of the gasifier equipment is used to model the fluid flow in the gasifier and source terms from the coal gasification process are captured using discrete-phase model source terms. Simulations using this approach can be very time consuming, making it difficult to imbed such models into overall system simulations for plant design and optimization. For such system-level designs, process flowsheet software is typically used, such as Aspen Plus®, where each component where each component is modeled using a reduced-order model. For advanced power-generation systems, such as integrated gasifier/gas-turbine combined-cycle systems (IGCC), the critical components determining overall process efficiency and emissions are usually the gasifier and combustor. Providing more accurate and more computationally efficient reduced-order models for these components, then, enables much more effective plant-level design optimization and design for control.

01 COAL, LIGNITE, AND PEAT↗

TASLIMAGE System #2 Technical Equivalence Evaluation

In early 2017, a second TASLIMAGE system (TASL 2) was procured from Track Analysis Systems, Ltd. The new device is intended to complement the first system (TASL 1) and to provide redundancy to the original system which was acquired in 2009. The new system functions primarily the same as the earlier system, though with different X-Y stage hardware and a USB link from the camera to the host computer, both of which contribute to a reduction in CR-39 foil imaging time. The camera and image analysis software are identical between the two systems. Neutron dose calculations are performed externally and independent of the imaging system used to collect track data, relying only on the measured recoil proton track density per cm 2 for a set of known-dose CR-39 foils processed in each etch.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enrichment Meter Dataset from High-Resolution Gamma Spectroscopy Measurements of U3O8 Enrichment Standards and UF6 Cylinder Wall Equivalents

The Enrichment Meter Principle (EMP) is the basis for a commonly used standard test method for the non-destructive assay of 235 U enrichment in bulk compounds [1]. The technique involves determining the net count rate in the direct 186 keV peak using medium or high energy gamma-ray spectrometry in a fixed geometry. With suitable correction for wall attenuation, compound type, rate loss (live time), and peaked background (if significant), the atom fraction of 235 U may be obtained from the counting rate from a linear relationship through the origin. The widespread use of this method for field verification of enrichment [2,3] together with the fact that the response function rests on fundamental physics considerations (i.e., is not represented by a convenient but arbitrary form) makes it an interesting example of uncertainty quantification, one in which one can expect a valid measurement model can be applied. When applied using NaI(Tl) and region of interest analysis, the technique is susceptible to both interference error and bias [2-4]. When implemented using high-resolution gamma-ray spectroscopy, the spectrum interpretation is considerable simplified and more robust [5]. However, a practical challenge to studying the uncertainty budget of the EMP method (for example, to test linearity, extract wall corrections and so forth using modern methods) is the availability of quality experimental data that can be referenced and shared. To fill this gap, the research team undertook an experimental campaign [6]. A measurement campaign was conducted to produce high-resolution gamma spectroscopy enrichment meter data comparable to UF 6 cylinder measurements. The purpose of this report is to provide both an introduction to and quality assurance (QA) of the raw data produced. This report is intended for the analyst or researcher who uses the raw data. Unfortunately, the raw data (i.e., the spectra files) are too voluminous to include in this report but can be requested from Steven Croft of the Safeguards & Security Technology Group (scroft@ornl.gov 865-241-2834). The complete processed data are tabulated in Appendix A. The analysis techniques used to produce the QA data presented in this report [e.g., three regions-ofinterest (ROI) peak extraction and batch analysis processes] are not the most sophisticated techniques available; analysts are encouraged to reanalyze the raw data using more sensitive techniques and to improve upon the results presented here. With that being said, the analysis techniques used here are more than adequate to present and inspect the quality of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Equivalency Evaluation of Lynx Electronics and Apex-InVivo software for the LLNL Whole Body Scanning Bed System

Lawrence Livermore National Laboratory (LLNL) Whole Body Counter (WBC) is replacing the following components for its scanning bed counting system: NIM electronics with modern Lynx electronics, The Alpha Workstation running VMS with a PC running Windows , and Abacos-Plus in-vivo counting software with the new Apex-InVivo software. These new components provide a compact design, extend the lifecycle of the system as a whole, reduce maintenance and user time, an improve overall ease of use. The technical evaluations and results described in this document demonstrate that the total system, incorporating these new components, provides results that comply with Internal Dosimetry requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron Activation Self-Shielding Factors for Common Dosimetry Foils in an ACRR Equivalent Environment

The results of a computational analysis of self-shielding factors are presented. The analysis highlights the total self-shielding, which is a combination of energy and spatial self-shielding, associated with different neutron detection materials. The Monte Carlo N-Particle (MCNP) transport code was used in conjunction with the Evaluated Nuclear Data File (ENDF) and the International Reactor Dosimetry and Fusion Files (IRDFF). This analysis was done with neutron activation analysis in mind, and therefore is modeled and presented in a similar fashion.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Many-Body Factorization & Position-Momentum Equivalence of SRC [Slides]

We study short-range correlations (SRC) using the generalized contact formalism (GCF) and quantum Monte Carlo (QMC) calculations of nuclei from deuteron to 40 Ca. We employ different realistic nuclear interactions and extract spin/isospin-dependent nuclear contacts in both coordinate and momentum space.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EPC-ES WIPP WAC Appendix A Equivalence Support Measurements 2019-2020

Characterization of low-level waste (LLW) at Los Alamos National Laboratory (LANL) is primarily performed by the Environmental Protection and Compliance - Environmental Stewardship (EPC-ES) Characterization Services team and/or the Nuclear Process Infrastructure (NPI--9) Nuclear Material Support Services team (hereafter referred to as the gamma spectroscopy teams). The gamma spectroscopy teams use portable high-purity germanium (HPGe) detector systems for the nondestructive assay (NDA) characterization of LLW. Controlled-approved procedures and processes for the use of such systems to assay LLW items are currently in place. Additionally, a number of performance studies have been conducted by the gamma spectroscopy teams to support the efficacy and quality of assay results generated by the established NDA process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstrated Low Pressure Loss Inlet and Low Equivalence Ratio Operation of a Rotating Detonation Engine (RDE) for Power Generation

Presentation. An Aerojet Rocketdyne (AR) program was funded by the National Energy Technology Laboratory (NETL), part of the U.S. Department of Energy, to evaluate the benefits of an RDE in a turbine power plant system. Aerojet Rocketdyne subcontracted a variety of support for the program with efforts in modeling, diagnostic techniques, and test campaigns. Over the span of the program more than 700 hot fire tests were conducted at 4 facilities with 7 RDE assemblies. This presentation will cover results from the final test campaign conducted by Aerojet Rocketdyne.

03 NATURAL GAS↗

Silicon-Equivalent Neutron Dose Estimations

Radiation transport calculations are often used to estimate dose or exposure to components and personnel surrounding a radiation source. The sources for these calculations are decaying radionuclides within the various nuclear materials. Under long-term radiation exposure, some components may show signs of material damage such as hardening, cracking, discoloration, etc. resulting from the dose received from nearby radioactive sources. Radiation dose quantities are a useful means to correlate material damage or degradation to radiation interactions. The degradation is often dependent on how incident radiation interacts and deposits energy into the material. This dependence implies that radiation dose should be properly defined for the material effect of interest. Generic dose quantities, such as total energy deposited, may not necessarily correlate well for degradation of any given material.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Linear Seismic Source Equivalents in 3D Nonlinear Models: Effects of Embedded Small-Scale, Near-Source Structures

Gaining a proper understanding of how Earth structure and other near-source properties affect estimates of explosion yield is important to the nonproliferation mission. The yields of explosion sources are often based on seismic moment or waveform amplitudes. Quantifying how the seismic waveforms or estimates of the source characteristics derived from those waveforms are influenced by natural or man-made structures within the near-source region, where the wavefield behaves nonlinearly, is required to understand the full range of uncertainty in those yield estimates. We simulate tamped chemical explosions using a nonlinear, shock physics code and couple the ground motions beyond the elastic radius to a linear elastic, full waveform seismic simulation algorithm through 3D media. In order to isolate the effects of simple small-scale 3D structures on the seismic wavefield and linear seismic source estimates, we embed spheres and cylinders close to the fully- tamped source location within an otherwise homogenous half-space. The 3 m diameters spheres, given their small size compared to the predominate wavelengths investigated, not surprisingly are virtually invisible with only negligible perturbations to the far-field waveforms and resultant seismic source time functions. Similarly, the 11 m diameter basalt sphere has a larger, but still relatively minor impact on the wavefield. However, the 11 m diameter air-filled sphere has the largest impact on both waveforms and the estimated seismic moment of any of the investigated cases with a reduction of ~25% compared to the tamped moment. This significant reduction is likely due in large part to the cavity collapsing from the shock instead of being solely due to diffraction effects . Although the cylinders have the same diameters as the 3 m spheres, their length of interaction with the wavefield produces noticeable changes to the seismic waveforms and estimated source terms with reductions in the peak seismic moment on the order of 10%. Both the cylinders and 11 m diameter spheres generate strong shear waves that appear to emanate from body force sources.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗