Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “enclosure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

105-H Reactor Interim Safe Storage Project Final Report

The following information documents the decontamination and decommissioning of the 105-H Reactor facility, and placement of the reactor core into interim safe storage. The D&D of the facility included characterization, engineering, removal of hazardous and radiologically contaminated materials, equipment removal, decontamination, demolition of the structure, and restoration of the site. The ISS work also included construction of the safe storage enclosure, which required the installation of a new roofing system, power and lighting, a remote monitoring system, and ventilation components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resource Form Factor and Installation of GFA Controllers

The focus of this task is to optimize the form and placement of a controller comprising the Grid Friendly™ appliance (GFA) controller, power supply and power relay (and/or a solid-state power electronic switch) that would command a domestic water heater to shed its load in response to stress on the electric power grid. The GFA controller would disconnect the water heater from its supply circuit whenever it senses a low voltage signal or other indicators of system stress communicated via the electric power distribution system. Power would be reconnected to the appliance when the GFA controller senses the absence of these signals. This project has also considered more frequent cycling of this controller’s relay switch to perform demand-side frequency regulation. The principal criteria considered in this optimization are reliability, cost and life expectancy of the GFA components. The alternative embodiments of the GFA equipment under consideration are: Option 1- installation inside the insulation space of the water heater between the tank and jacket Option 2 containment in a separate nearby electrical enclosure Option 3 - as a modification or adjunct to the distribution panel housing and/or the breaker that protects the water heater supply circuit.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparison of Modifications to MELCOR versions 1.8.2 and 1.8.6 for ITER Safety Analysis

During the Engineering Design Activity of the International Thermonuclear Experimental Reactor (ITER), the MELCOR 1.8.2 code was selected as one of several codes to be used to perform ITER safety analyses [1]. MELCOR was chosen because it has the capability of predicting coolant pressure, temperature, mass flow rate, and radionuclide and aerosol transport in nuclear facilities and reactor cooling systems. MELCOR can also predict structural temperatures (e.g. first wall, blanket, divertor, and vacuum vessel) resulting from energy produced by radioactive decay heat and/or chemical reactions (oxidation). The Idaho National Laboratory (INL) Fusion Safety Program (FSP) made fusion specific modifications to the MELCOR 1.8.2 code [2-6], including models for water freezing, air condensation, beryllium, carbon, and tungsten oxidation in steam and air environments, flow boiling in coolant loops, and radiation in enclosures, that allowed MELCOR to assess the thermal hydraulic response of ITER cooling systems and the transport of radionuclides as aerosols during accident conditions. Recently, the ITER International Organization (IO) used a “pedigreed” version of MELCOR 1.8.2 [7] to perform accident analyses for ITER’s “Rapport Préliminaire de Sûreté” (Report Preliminary on Safety - RPrS). The MELCOR thermal-hydraulics code [8] is currently under development at the Sandia National Laboratory (SNL) for the US Nuclear Regulatory Commission (NRC). MELCOR is used to model the progression of severe accidents in light water fission reactors. Because MELCOR has undergone many improvements between version 1.8.2 and 1.8.6, the INL FSP decided to introduce fusion modifications into MELCOR 1.8.6, and thereby produce a version of MELCOR 1.8.6 with similar capabilities to the pedigreed version of MELCOR 1.8.2 used for the ITER RPrS. We have applied this version of MELCOR 1.8.6 to the same set of problems used in the MELCOR 1.8.2 pedigree analysis [7]. Section 2 describes a non-regression analysis that involves comparing the results from the modified version of MELCOR 1.8.6 against those predicted by the original, unmodified version of MELCOR 1.8.6. The purpose of this non-regression analysis is to demonstrate that the modifications made to the MELCOR 1.8.6 code do not drastically alter the intended functions of the MELCOR base code, and if they do to explain why the departure occurs and if the change is needed. The analysis was performed using the demonstration problem that came with the MELCOR 1.8.6 source distribution. Section 3 makes a comparison between the pedigreed version of MELCOR 1.8.2 and the new modified version of MELCOR 1.8.6 on a set of accident problems used by the ITER Joint Central Team (JCT) in the Generic Site Safety Report (GSSR) [9]. Finally, in section 4, the two versions of the code are compared on a series of developmental test problems described in the change documents [2-4, 6].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

100-N Area Strontium-90 Treatability Demonstration Project: Phytoextraction Along the 100-N Columbia River Riparian Zone – Field Treatability Study

Strontium-90 (90Sr) is present both in the aquifer near the river and in the vadose and riparian zones of the river’s shore at 100-NR-2. Phytoextraction of 90Sr is being considered as a potential remediation system along the riparian zone of the Columbia River. Phytoextraction would employ coyote willow (Salix exigua). Past studies have shown that willow roots share uptake mechanisms for Sr with Ca, a plant macronutrient as well as no discrimination between Sr and 90Sr. Willow 90Sr concentration ratios [CR’s; (pCi 90Sr/g dry wt. of new growth tissue)/(pCi 90Sr/g soil porewater)] were consistently greater than 65 with three-quarters of the assimilated label partitioned into the above ground shoot. Insect herbivore experiments also demonstrated no significant potential for bioaccumulation or food chain transfer from their natural activities. The objectives of this field study were three-fold: (1) to demonstrate that a viable, “managed” plot of coyote willows can be established on the shoreline of the Columbia River that would survive the same microenvironment to be encountered at the 100-NR-2 shoreline; (2) to show through engineered barriers that large and small animal herbivores can be prevented from feeding on these plants; and (3) to show that once established, the plants will provide sufficient biomass annually to support the phytoextraction technology. A field treatability demonstration plot was established on the Columbia River shoreline alongside the 100-K West water intake at the end of January 2007. The plot was delimited by a 3.05 m high chain-link fence and was approximately 10 x 25 m in size. A layer of fine mesh metal small animal screening was placed around the plot at the base of the fencing to a depth of 45 cm. A total of sixty plants were placed in six slightly staggered rows with 1-m spacing between plants. The actual plot size was 0.00461 hectare (ha). At the time of planting (March 12, 2007), the plot was located about 10 m from the river’s edge. Less than two weeks later (March 21), the river began the spring rise. Periodic (daily) or continuous flooding occurred at the site over the next 3 to 4 months. River levels at times were over the top of the enclosure’s fence. This same pattern was repeated for the next 2 years. It was however evident that even submerged for part, or all of the day, that the plants continued to flourish. There were no indications of herbivory or animal tracks observed within the plot although animals were present in the area. Biomass production over the three years followed a typical growth curve with a yield of about 1 kg for the first year when the trees were establishing themselves, 4 kg for the second, and over 20 kg for the third when the trees were entering the exponential phase of growth. On a metric Ton per hectare (mT/ha) basis this would be 0.2 mT/ha in 2007, 0.87 mT/ha in 2008, and 4.3 mT/ha in 2009. Growth curve extrapolation predicts 13.2 mT/ha during a fourth year and potentially 29.5 mT/ha following a fifth year. Using the observed Ca and Sr concentrations found in the plant tissues, and Sr CR’s calculated from groundwater analysis, projected biomass yields suggest the trees could prove effective in removing the contaminant from the 100-NR-2 riparian zone.

09 BIOMASS FUELS↗

LCLS Heavy Met Outgassing Tests

A Heavy Met that is 95% tungsten, 3% nickel and 2% iron and sintered to 100% density and is Ultra High Vacuum (UHV) compatible is proposed for use as the X-ray slit in the Front End Enclosure and the Fixed Mask for the Linac Coherent Light Source (LCLS). The Heavy Met was tested in the LLNL Vacuum Sciences and Engineering Lab (VSEL) to determine its outgassing rate and its overall compatibility with the vacuum requirements for LCLS.

43 PARTICLE ACCELERATORS↗

SPRUCE Manual Phenology Observations and Photographs Beginning in 2011

This dataset contains periodic (most often weekly during the active season) observations of the phenology of vegetation bud swell, leaf out, leaf off, flowering, fruiting and the nature of snow cover and ice presence from the 2011-2023 growing seasons. These observations are supplemented by the collection of images from periodic photographs of the experimental plots (e.g., panoramic photographs) or images within plots (e.g., pictures of vegetation development or community status within defined ground footprints such as flux collars). A summary of vegetation phenology and snow and ice presence form 2011-2016 is also provided. Related data sets are also available that summarize site phenology (see Related Datasets). This dataset contains 336 phenology notes files in *.pdf format, 2284 phenology photos in *.jpg format, and three companion files containing phenology summaries, methodological, other contextual information. Early observations were conducted throughout the S1-Bog with an emphasis on the southern end of the bog. Observations collected since the spring of 2013 have focused on the southern end of the S1-Bog and the plots 2 through 21 of the SPRUCE experiment. Beginning in 2015 those observations included assessments within the enclosure space surrounding plots 4, 6, 8, 10, 11, 13, 16, 17, 19 and 20. These observations are ongoing, and this dataset will be appended annually.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE Vegetation Phenology in Experimental Plots from Phenocam Imagery, 2015-2018

The most recent version of these data are available https://doi.org/10.25581/spruce.100/1874948 and supersedes all previous versions. This dataset consists of PhenoCam data from the SPRUCE experiment from the beginning of whole ecosystem warming in August 2015 through March-31 of 2019, with start- and end-of-season phenological transition dates derived through the end of autumn 2018. Digital cameras, or phenocams, installed in each SPRUCE enclosure track seasonal variation in vegetation “greenness”, a proxy for vegetation phenology and associated physiological activity. Three separate regions of interest (ROIs) were defined for each camera field of view, corresponding to different vegetation types and demarcating: Picea trees (vegetation type EN, for evergreen needleleaf); Larix trees (vegetation type DN, for deciduous needleleaf); and the mixed shrub layer (vegetation type SH).

54 ENVIRONMENTAL SCIENCES↗

SPRUCE Experimental Plot Top View Aerial Images beginning June 2019

This data set provides a record of the aerial images of the SPRUCE experimental plots obtained periodically using an unmanned aerial vehicle (UAV) with attached camera from 2019-05-05- to 2022-08-25. New images of the plots will be added periodically. The initial RGB images may be used for studies of greenness and snow coverage and compared with ground-based measurements and chamber-based tree and shrub Phenocam images (e.g. Schädel et al., 2022). Also included are NDVI (Normalized Difference Vegetation Index) images showing calculated difference between visible near-infrared (NIR) light reflectance from vegetation, as well as infrared (IR) and multispectral images. Files are presented in JPEG (*.jpg) or PDF (*.pdf) format inside of 28 compressed (*.zip) files. Images were collected for the 10 plots with enclosures, the 7 unchambered plots, and the environmental monitoring instrument cluster area. Images are slightly off-plot center at 12 to 15 meters above ground level or approximately 2 meters above the top of an experimental chamber.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE Plot-Level Water Table Data Assessments for Absolute Elevations and Height with Respect to Mean Hollows Beginning in 2015

This data set provides a record of the half-hourly automated water table depth data collected for 12 SPRUCE plots (4, 6, 7, 8, 10, 11, 13, 14, 16, 17, 19, 20, and 21) beginning during deep peat heating (DPH) in 2015 and continuing throughout the whole ecosystem warming (WEW) manipulations for the SPRUCE Project (Hanson et al. 2017). The data currently cover 2015-05-12 through 2024-12-31 and will be updated periodically throughout the duration of the SPRUCE project. Also provided are daily plot normalized data for water table depths with respect to mean hollow locations within each plot. The hollow referenced data provide the basis for the intercomparison of peat saturation or aeration across treatment plots. A limited data set for manual water table observations made periodically from 2015-2022 are also provided as a reference to the plot center automated observations. In August 2015, WEW was initiated at 5 warming levels (+0, +2. +4.5, +6.75 and +9 °C) with 2 plots per warming level. DPH measurements were underway before the initiation of WEW heating treatments and both are expected to operate through 2025. Elevated CO2 treatments were added in June 2016 (Enclosures 4, 10, 11, 16 and 19). All measurements were made at the 8.1-ha S1 bog forest site in northern Minnesota, 40 km north of Grand Rapids, in the USDA Forest Service Marcell Experimental Forest (MEF). This dataset contains three data files in comma separated (*.csv) format.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE Vegetation Phenology in Experimental Plots from Phenocam Imagery, 2015-2019

The most recent version of these data are available https://doi.org/10.25581/spruce.100/1874948 and supersedes all previous versions. This dataset consists of PhenoCam data from the SPRUCE experiment from the beginning of whole ecosystem warming in August 2015 through March-31 of 2020, with start- and end-of-season phenological transition dates derived through the end of autumn 2019. Digital cameras, or phenocams, installed in each SPRUCE enclosure track seasonal variation in vegetation “greenness”, a proxy for vegetation phenology and associated physiological activity. Three separate regions of interest (ROIs) were defined for each camera field of view, corresponding to different vegetation types and demarcating: Picea trees (vegetation type EN, for evergreen needleleaf); Larix trees (vegetation type DN, for deciduous needleleaf); and the mixed shrub layer (vegetation type SH).

54 ENVIRONMENTAL SCIENCES↗

SPRUCE Vegetation Phenology in Experimental Plots from Phenocam Imagery, 2015-2020

The most recent version of these data are available https://doi.org/10.25581/spruce.100/1874948 and supersedes all previous versions. This data set consists of PhenoCam data from the SPRUCE experiment from the beginning of whole ecosystem warming (Hanson et al. 2017) in August 2015 through March 31 of 2021, with start- and end-of-season phenological transition dates derived through the end of autumn 2020. Digital cameras, or phenocams, installed in each SPRUCE enclosure track seasonal variation in vegetation “greenness”, a proxy for vegetation phenology and associated physiological activity. Three separate regions of interest (ROIs) were defined for each camera field of view, corresponding to different vegetation types and demarcating (1) Picea trees (vegetation type EN, for evergreen needleleaf); (2) Larix trees (vegetation type DN, for deciduous needleleaf); and (3) the mixed shrub layer (vegetation type SH). User note: A list of previous versions can be found in the Related Datasets section of the user guide.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE Radiocarbon analyses quantify peat carbon losses with increasing temperature in a whole ecosystem warming experiment, 2014-2020

This data set contains three *.csv data files with measurements of organic and inorganic carbon fractions and radiocarbon fractions in peat porewater profiles. Measurements of carbon fractions from enclosure drainage outflows are also included. Porewater profiles were collected up to four times annually from 2014 to 2020 with a piezometer and outflow samples were collected up to eight times annually in 2016 and 2017. Porewater organic and inorganic fractions were measured using a Finnigan Mat Delta V Isotope Ratio Mass Spectrometer and a Shimadzu Total Organic Carbon. Radiocarbon analyses were conducted at Lawrence Livermore National Laboratory (LLNL). The peat soils were subjected to deep peat heating (DPH) beginning in June of 2014 followed by whole ecosystem warming (WEW) in August of 2015 (Hanson et al. 2017). The experimental work was conducted in a Picea mariana [black spruce] – Sphagnum spp. bog forest in northern Minnesota, 40 km north of Grand Rapids, in the USDA Forest Service Marcell Experimental Forest (MEF).These changes in these inorganic and organic carbon fractions in response to whole ecosystem warming may alter decomposition and microbial communities, as well as overall soil carbon storage.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE Vegetation Phenology in Experimental Plots from Phenocam Imagery, 2015-2021

This data set consists of PhenoCam data from the SPRUCE experiment from the beginning of whole ecosystem warming (Hanson et al. 2017) in August 2015 through March 31 of 2022, with start- and end-of-season phenological transition dates derived through the end of autumn 2021. Digital cameras, or phenocams, installed in each SPRUCE enclosure track seasonal variation in vegetation “greenness”, a proxy for vegetation phenology and associated physiological activity. Three separate regions of interest (ROIs) were defined for each camera field of view, corresponding to different vegetation types and demarcating (1) Picea trees (vegetation type EN, for evergreen needleleaf); (2) Larix trees (vegetation type DN, for deciduous needleleaf); and (3) the mixed shrub layer (vegetation type SH). User Note: This dataset supersedes previous versions of SPRUCE Vegetation Phenology in Experimental Plots from Phenocam Imagery. A list of previous versions can be found in the Related Datasets section of the user guide.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE: Carbon Dioxide and Methane Soil Flux Measurements at High Temporal Resolution, Beginning in 2022

This data set contains high temporal resolution measurements of greenhouse gas flux (CO2 and CH4) from the SPRUCE (Spruce and Peatland Responses Under Changing Environments) experiment (Hanson et al. 2017) over the growing seasons in 2022 (30-minute resolution) and 2023 (15-minute resolution). Additional data will be appended to this dataset periodically until the close out of the SPRUCE experiment in 2025. This dataset contains two data files in comma-separate (*.csv) format. ABB GLA131-GGA CO2/CH4 gas analyzers, each paired with an Eosense eosMX multiplexer and 2 eosAC-LT automated flux chambers, were deployed from during the 2022 and 2023 growing seasons (2022-06-06 – 2023-10-26). Each SPRUCE experimental enclosure included two Eosense 50 cm diameter flux chambers with 40 cm tall stainless steel collars embedded approximately 15 cm into the peat soil, to measure soil gas flux of peatland ecosystem moss-shrub communities. . Measurements were taken for three minutes, alternating between the flux chambers, with each Eosense flux chamber sampling gas fluxes four times per hour in 2023 and twice per hour for 2022. In addition, time-series environmental data measured at the flux chamber are included: Photosynthetically active radiation (PAR), soil temperature, soil volumetric water content (at 10 cm depth), air temperature, soil temperature (0-200 cm depth), and volumetric water at 20 cm depth.

Spruce and Peatland Responses Under Changing Envir↗

Monitoring of Double-Stud Wall Moisture Conditions in the Northeast

BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast Field test data available for wood moisture contents, temperature, and relative humidity. STRUCTURE - House - Devens, MA 01432 Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulose, and 5.5-in. ocSPF at the exterior of a double-stud wall (to approximate conventional 2 x 6 wall construction and insulation levels, acting as a control wall). These assemblies were repeated on the north and south orientations, for a total of six assemblies. Data were collected from December 2011 through July 2014, capturing three winters of operation in various states. Winter 2011-2012 was very mild (warm) and the house had very low interior relative humidity (RH) because it was unoccupied. Winter 2012-2013 was colder and the house had very high (40%-50%) interior RH until the ventilation system was put into operation (mid-February 2013). Winter 2013-2014 was very cold, but the ventilation system was operated, resulting in moderate interior RHs. Under "normal" interior conditions (functioning ventilation system, wintertime RH 10%-30%), ocSPF walls (both 12 in. and 5.5 in.) with latex paint as interior vapor control (nominally Class III, but possibly more vapor open) showed low risk; all sheathing moisture contents (MCs) remained lower than 20%. However, the 12-in. cellulose wall had MCs higher than 20% on the north side. In addition, the cellulose wall sheathing-insulation interface had high RH conditions. Under high interior humidity loading (nonfunctional ventilation system, 40%-50% interior RH), all test walls showed MCs and sheathing-insulation interface RHs well into the high risk range. The cellulose walls showed particularly high MCs (sheathing in excess of 30%), while the ocSPF walls showed MCs in the 18%-25% range. In addition, the monitoring showed evidence of liquid water condensation (which can result in quick degradation) in all walls; the condensation was substantial in the cellulose walls. These condensation issues occurred on the north and south sides. But in all walls, during each summer after a winter of wetting, moisture levels fell well into the safe range. Based on the difference between the winters, it is clear that interior RH can have a tremendous effect on the performance of enclosure systems, in terms of interstitial condensation risks, when using more vapor-open interior finishes such as latex paint. The ocSPF walls showed consistently lower MCs and interface RH levels than the cellulose walls. Although air leakage cannot be eliminated as a possibility, it is likely that at the thicknesses applied, the ocSPF provided reasonable vapor control (1.5-3.5 perms when combined with Class III latex paint) under normal loading conditions. The collected data were analyzed in terms of ASHRAE Standard 160 criteria (tabulating hours with RH and temperatures that support mold growth), using the calculated surface RH at the sheathing-insulation interface. All north-facing walls failed through all three winters; in particular, there were large numbers of failure hours during the high humidity winter (2012-2013). Sheathing-insulation interface temperatures and RHs during the high humidity winter showed many hours with mold risk conditions (high humidity and sufficient temperature for mold growth).

Array↗

Field Testing of Compartmentalization Methods for Multifamily Construction - Washington DC

BSC TO5 Task 2.1 Field Testing of Compartmentalization Methods for Multifamily Construction - Capitol Heights, MD 20743 A building comprising five vertical townhome units was built in the Washington, D.C., area; the townhomes were three-story slab-on-grade units (1700-2000 ft2) with a rear-facing "tuck under" garage. The three-story townhome design results in 3 ACH50 being equivalent to a stringent surface-area based target (0.16-0.17 CFM50/ft2 building enclosure). The party walls between units were area separation walls, with a 2-hour fire resistance rating (Underwriters Laboratories U347 assembly; equivalent to U373 and U336). This assembly has a 1-in. vertical air cavity on each side of a 2-in. vertical gypsum panel in the middle of the assembly, resulting in an airflow network that is connected over multiple floors (despite nominal draft stopping), and has potential connections to exterior conditions. The test townhomes were built with several experimental airtightness details, including taping of exterior sheathing as an air barrier closure detail (in particular, at area separation walls). Various measures were applied to the units for this experiment, including a "control" conventional construction unit and some units with "improved" detailing (without taped sheathing).

air leakage↗

Evaluation of Crawlspace Retrofits in Multifamily Buildings

In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community un-vented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring.The existing condition was a vented crawlspace with an un-insulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this un-vented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods.While the un-vented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

affordable housing↗

Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program

In 2009, National Grid started a DER pilot program that offered technical support and financial incentives to qualified Massachusetts homeowners who planned and successfully completed a retrofit that incorporated the performance requirements and goals of the National Grid DER measures package. This DER measures package, developed through collaboration with Building Science Corporation (BSC), includes specific thermal and airtightness goals for the enclosure components as well as health, safety, durability, and indoor air quality requirements. By providing measures that can be included with common renovation activities such as roof replacement, window replacement, re-siding, basement remediation, and remodeling, this DER measures package is expected to have widespread application for existing homes in the New England area. The post-retrofit performance and cost ranges provided by this research project can provide concrete input for homeowners who are considering a DER. Field test data available for air tightness measured using blower door test. House 1 - Address Belchertown, MA 01007, Notes: Energy Savings: 75%, Company: Clark House 2-1 and 2 - Address (1) Brownsberger, MA 02478 and (2) Belmont, MA 02478, Notes Energy Savings: 73%, Company: Brownsberger House 3 - Address Millbury, MA 01527, Notes Energy Savings: 31%, Company: Tweedly House 4 - Address Milton, MA 02186 Notes Energy Savings: 42%, Company: Koh House 5 - Address Quincy, MA 02169, Notes Energy Savings: 57%, Company: Hall House 6-1 and 2 - Address Arlington, MA 02476, Notes Energy Savings: 55%, Company: Venable-Hwang House 7 - Address Newton, MA 02459, Notes Energy Savings: 42%, Company: Lavine House 8-1, 2, and 3 - Address Jamaica Plain, MA 02130, Notes Energy Savings: 43%, Company: Buhs House 9 - Address Northampton, MA 01060, Notes Energy Savings: 49%, Company: Wick House 10 - Address Lancaster, MA 01523, Notes Energy Savings: 40%, Company: Habitat for Humanity of North Central Massachusetts House 11 - Address Brookline, MA 02445, Notes Energy Savings: 27%, Company: Aquiline House 12 - Address Westford, MA 01886, Notes Energy Savings: 30%, Company: Atkins House 13 - Address Gloucester, MA 01930, Notes Energy Savings: 35%, Company: Cunningham

airtightness↗