Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emission rates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

SPT-CL J2215−3537: A Massive Starburst at the Center of the Most Distant Relaxed Galaxy Cluster

Abstract We present the discovery of the most distant, dynamically relaxed cool core cluster, SPT-CL J2215−3537 (SPT2215), and its central brightest cluster galaxy (BCG) at z = 1.16. Using new X-ray observations, we demonstrate that SPT2215 harbors a strong cool core with a central cooling time of 200 Myr (at 10 kpc) and a maximal intracluster medium cooling rate of 1900 ± 400 M ⊙ yr −1 . This prodigious cooling may be responsible for fueling the extended, star-forming filaments observed in Hubble Space Telescope imaging. Based on new spectrophotometric data, we detect bright [O ii ] emission in the BCG, implying an unobscured star formation rate (SFR) of 320 − 140 + 230 M ⊙ yr −1 . The detection of a weak radio source (2.0 ± 0.8 mJy at 0.8 GHz) suggests ongoing feedback from an active galactic nucleus (AGN), though the implied jet power is less than half the cooling luminosity of the hot gas, consistent with cooling overpowering heating. The extreme cooling and SFR of SPT2215 are rare among known cool core clusters, and it is even more remarkable that we observe these at such high redshift, when most clusters are still dynamically disturbed. The high mass of this cluster, coupled with the fact that it is dynamically relaxed with a highly isolated BCG, suggests that it is an exceptionally rare system that must have formed very rapidly in the early universe. Combined with the high SFR, SPT2215 may be a high- z analog of the Phoenix cluster, potentially providing insight into the limits of AGN feedback and star formation in the most massive galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

A Method to Extract Spatially Resolved Polycyclic Aromatic Hydrocarbon Emission from Spitzer Spectra: Application to M51

The mid-infrared spectrum contains rich diagnostics to probe the physical properties of galaxies, among which the pervasive emission features from polycyclic aromatic hydrocarbons (PAHs) offer promising means of estimating the star formation rate (SFR) relatively immune from dust extinction. This paper investigates the effectiveness of PAH emission as a SFR indicator on subkiloparsec scales by studying the Spitzer/IRS mapping-mode observations of the nearby grand-design spiral galaxy M51. We present a new approach of analyzing the spatial elements of the spectral data cube that simultaneously maximizes spatial resolution and spatial coverage, while yielding reliable measurements of the total, integrated 5–20 μm PAH emission. We devise a strategy of extracting robust PAH emission using spectra with only partial spectral coverage, complementing missing spectral regions with properly combined mid-infrared photometry. We find that in M51 the PAH emission correlates tightly with the extinction-corrected far-ultraviolet, near-ultraviolet, and Hα emission, from scales of ∼0.4 kpc close to the nucleus to 6 kpc out in the disk of the galaxy, indicating that PAH serves as an excellent tracer of SFR over a wide range of galactic environments. But regional differences exist. Close to the active nucleus of M51 the 6.2 μm feature is weaker, and the overall level of PAH emission is suppressed. The spiral arms and the central star-forming region of the galaxy emit stronger 7.7 and 8.6 μm PAH features than the inter-arm regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ignition and Combustion of Bulk Metals in a Microgravity Environment

Results of a study of heterogeneous and homogeneous combustion of metals in reduced gravity are presented. Cylindrical titanium and magnesium samples are radiatively ignited in pure-oxygen at 1 atm. Qualitative observations, propagation rates, and burning times are extracted from high-speed cinematography. Time-resolved emission spectra of gas-phase reactions are acquired with an imaging spectrograph. Lower propagation rates of the reacting mass on titanium and of ignition waves on magnesium are obtained at reduced gravity. These rates are compared to theoretical results from fire-spread analyses with a diffusion/convection controlled reaction. The close agreement found between experimental and theoretical propagation rates indicates the strong influence of natural-convection-enhanced oxygen transp6rt on burning rates. Lower oxygen flux and lack of condensed product removal appear to be responsible for longer burning times of magnesium gas-phase diffusion flames in reduced gravity. Spherically symmetric explosions in magnesium flames at reduced gravity (termed radiation-induced metal explosions, or RIME) may be driven by increased radiation heat transfer from accumulated condensed products to an evaporating metal core covered by a porous, flexible oxide coating. In titanium specimens, predominantly heterogeneous burning characterizes the initial steady propagation of the molten mass, while homogeneous gas-phase reactions are detected around particles ejected from the molten mixture. In magnesium specimens, band and line reversal of all the UV spectral systems of Mg and MgO are attributed to the interaction between small oxide particles and the principal gaseous emitters.

Branch, Melvyn C.↗

Suppression and Structure of Low Strain Rate Nonpremixed Flames

The agent concentration required to achieve suppression of low strain rate nonpremixed flames is an important fire safety consideration. In a microgravity environment such as a space platform, unwanted fires will likely occur in near quiescent conditions where strain rates are very low. Diffusion flames typically become more robust as the strain rate is decreased. When designing a fire suppression system for worst-case conditions, low strain rates should be considered. The objective of this study is to investigate the impact of radiative emission, flame strain, agent addition, and buoyancy on the structure and extinction of low strain rate nonpremixed flames through measurements and comparison with flame simulations. The suppression effectiveness of a suppressant (N2) added to the fuel stream of low strain rate methane-air diffusion flames was measured. Flame temperature measurements were attained in the high temperature region of the flame (T greater than 1200 K) by measurement of thin filament emission intensity. The time varying temperature was measured and simulated as the flame made the transition from normal to microgravity conditions and as the flame extinguished.

Hamins, Anthony↗

Indicators of Global Climate Change 2023: annual update of key indicators of the state of the climate system and human influence

Intergovernmental Panel on Climate Change (IPCC) assessments are the trusted source of scientific evidence for climate negotiations taking place under the United Nations Framework Convention on Climate Change (UNFCCC). Evidence-based decision-making needs to be informed by up-to-date and timely information on key indicators of the state of the climate system and of the human influence on the global climate system. However, successive IPCC reports are published at intervals of 5–10 years, creating potential for an information gap between report cycles. We follow methods as close as possible to those used in the IPCC Sixth Assessment Report (AR6) Working Group One (WGI) report. We compile monitoring datasets to produce estimates for key climate indicators related to forcing of the climate system: emissions of greenhouse gases and short-lived climate forcers, greenhouse gas concentrations, radiative forcing, the Earth's energy imbalance, surface temperature changes, warming attributed to human activities, the remaining carbon budget, and estimates of global temperature extremes. The purpose of this effort, grounded in an open-data, open-science approach, is to make annually updated reliable global climate indicators available in the public domain. As they are traceable to IPCC report methods, they can be trusted by all parties involved in UNFCCC negotiations and help convey wider understanding of the latest knowledge of the climate system and its direction of travel. The indicators show that, for the 2014–2023 decade average, observed warming was 1.19 [1.06 to 1.30] °C, of which 1.19 [1.0 to 1.4] °C was human-induced. For the single-year average, human-induced warming reached 1.31 [1.1 to 1.7] °C in 2023 relative to 1850–1900. The best estimate is below the 2023-observed warming record of 1.43 [1.32 to 1.53] °C, indicating a substantial contribution of internal variability in the 2023 record. Human-induced warming has been increasing at a rate that is unprecedented in the instrumental record, reaching 0.26 [0.2–0.4] °C per decade over 2014–2023. This high rate of warming is caused by a combination of net greenhouse gas emissions being at a persistent high of 53±5.4 Gt CO 2 e yr -1 over the last decade, as well as reductions in the strength of aerosol cooling. Despite this, there is evidence that the rate of increase in CO 2 emissions over the last decade has slowed compared to the 2000s, and depending on societal choices, a continued series of these annual updates over the critical 2020s decade could track a change of direction for some of the indicators presented here.

54 ENVIRONMENTAL SCIENCES↗

Temperature dependence of the rate constants for reactions of O/1D/ atoms with a number of halocarbons

Results are reported for an experimental study of the reactions of O(1D) with CCl4, CFCl3, CF2Cl2, CHFCl2, CHF2Cl, and CF2ClCFCl2 over the temperature range from 173 to 343 K, based on the time-resolved emission of O(1D) at 630 nm. The experiments involved photolysis of O3 by Nd-YAG laser pulses and measurements of 630-nm emission intensity in mixtures with He and the various halocarbons. Pseudo-first-order rate constants are derived from plots of the logarithms of the 630-nm emission intensities as a function of time for particular He/O3/halocarbon mixtures, and second-order rate constants are then obtained from plots of these pseudo-first-order rate constants as a function of halocarbon concentration at constant He and O3 concentrations. No temperature dependence of the second-order rate constants is observed over the range studied, within the precision of the measurements. It is found that the rate constants decrease as H is substituted for Cl in a halocarbon molecule and as F is substituted for H or Cl.

Davidson, J. A.↗

Antarctic Meltwater Accelerates Southern Ocean Evolution Under Projected Atmospheric Warming

Increasing basal meltwater from Antarctic ice shelves may impact the Southern Ocean properties that feed back on the rate of melting. We investigate this feedback in a high‐emissions scenario using an Earth‐system model with interactive ice‐shelf basal melting, an improvement on previous studies that did not have the capability to evolve melt rates and the ocean state self‐consistently. We find that when interactive melt increases, it primarily accelerates the evolution of a spatial pattern of continental shelf warming and cooling that is initiated by freshening and sea‐ice formation decline due to projected atmospheric warming. The competition between enhanced warming at depth from reduced ventilation and enhanced continental shelf cooling from reduced dense water export leads to net ~35% reduction in ice‐shelf meltwater input into the Southern Ocean over the 21st century. Omitting this feedback introduces a bias in the timing of projected ocean‐melt‐driven ice loss from Antarctica.

58 GEOSCIENCES↗

Searching water megamasers by using mid-infrared spectroscopy (I): Possible mid-infrared indicators

ABSTRACT Water megamasers at 22 GHz with a gas disc configuration in galaxies provide the most precise measurements of supermassive black hole masses, as well as independent constraints on the Hubble constant in the nearby universe. The existence of other maser types, such as jet or outflow masers, represents another tracer for AGN science. However, the detection rate of water megamasers in galaxies is extremely low. Over 40 yr, only ∼ 160 galaxies are found to harbour maser emission, and ∼30 per cent of them show features in their maser emission that indicate a disc-like geometry. Therefore, increasing the detection rate of masers is a crucial task to allow expanding on maser studies. We present a comparison of mid-infrared spectroscopic data between a maser galaxy sample and a Seyfert 2 control sample. We find that maser galaxies show significant peculiarities in their mid-infrared spectra: (1) Maser galaxies tend to present stronger silicate absorption at τ9.7 $\mu\mathrm{ m}$ than the control sample, (2) PAH 11.3 $\mu$m emission in maser galaxies is much weaker than in the control sample, (3) spectral indices at 20–30 $\mu$m are steeper in maser galaxies than in the control sample and tend to be mid-infrared enhanced population. We conclude that there may be good indicators in mid-infrared and far-infrared which could differentiate maser and non-maser Seyfert 2 galaxies. Upcoming infrared facilities, such as the James Webb Space Telescope, may be able to exploit these and other useful criteria and tracers for water megamaser observations.

Lam, Man I.↗

Time dependences of the 0.51 and 2.2 MeV lines in solar flares

The time dependence of the 0.51 MeV line in solar flares is determined by the following factors: variation with time of the rate of nuclear reactions which produce the positron emitters; mean lives of the positron emitters; slowing-down of the positrons which depends on the ambient density and magnetic field; and annihilation or positronium formation times of the positrons with free or bound electrons. The discussion is limited to the observed intensity-time profile of a 0.35-8 MeV gamma-ray emission and of a 0.51-MeV line calculated for three different ambient densities in the annihilation region. Major conclusions are that (1) MeV electrons and protons of at least 30 MeV/nuc have similar time dependences and hence a common origin in the flare region, which support a two-phase acceleration model in solar flares; and (2) the delayed character of the 0.51-MeV emission is clearly defined, where at a time when the rate of nuclear reactions is zero, there still is considerable 0.51-MeV emission.

Ramaty, R.↗

Resonant Compton cooling and annihilation line production in gamma-ray bursts

Attention is given to a synchrotron self-Compton emission model for gamma-ray bursts which produces narrow annihilation features for a variety of field strengths, primary electron injection energies, and injection rates. In this model, primary electrons are injected and cooled by synchrotron emission in a strong, homogeneous magnetic field, resulting in a pair cascade. Multiple resonant scattering with cyclotron photons efficiently traps and cools pairs in the ground state to an average energy where the Compton energy loss rate is zero, which is in agreement with previous estimates of a Compton temperature. The particle distributions in the ground state are determined by numerically solving the Fokker-Planck equation in the steady state. In the case of isotropic injection of primary electrons, a significant narrow-line feature appears in the overall emission. In the case of beamed injection, the annihilation line is broadened to the extent that it would not be observable.

Preece, R. D.↗

Cost and Performance Baseline for Fossil Energy Plants Supplement: Sensitivity to CO 2 Capture Rate In Coal-Fired Power Plants

The cost and performance of various plants designed to meet a range of carbon dioxide (CO 2 ) emission limits are evaluated in this report by varying the CO 2 capture rate. The base cases for these designs are the supercritical (SC) pulverized coal (PC) plant and the General Electric Power (GEP) integrated gasification combined cycle (IGCC) plant from the Department of Energy (DOE) National Energy Technology Laboratory (NETL) report “Cost and Performance Baseline for Fossil Energy Plants, Volume 1: Bituminous Coal and Natural Gas to Electricity, Revision 4” (“Bituminous Baseline”).

20 FOSSIL-FUELED POWER PLANTS↗

Galaxy interactions and star formation: Results of a survey of global H-alpha emission in spiral galaxies in 8 clusters

Kennicutt and Kent (1983) have shown that the global H alpha emission from a spiral galaxy is an indicator of the formation rate of massive stars. Moss, Whittle and Irwin (1988) have surveyed two clusters (Abell 347 and 1367) for galaxies with H alpha emission using a high dispersion objective prism technique. The purpose of the survey is to investigate environmental effects on star formation in spiral galaxies, and in particular to ascertain whether star formation is enhanced in cluster spirals. Approximately 20 percent of CGCG galaxies were detected in emission. Two plates of excellent quality were obtained for each of the two clusters, and galaxies were only identified to have emission if this was detected on both plates of a plate pair. In this way, plate flaws and other spurious identifications of emission could be rejected, and weak emission confirmed. The results of this survey have been discussed by Moss (1987). The detected galaxies are of types SO-a and later. The frequency with which galaxies are detected in emission increases towards later morphological type as expected (cf. Kennicutt and Kent 1983). There is no evidence of any dependence of the frequency of detected emission on the absolute magnitude of the galaxy (cf. Moss and Whittle 1990), but there is a strong correlation between a disturbed morphological appearance of the galaxy and the detection of emission. Furthermore it is found that the emission is more centrally concentrated in those galaxies which show a disturbed morphology. It may be noted that the objective prism plate gives a spectrum of a 400 A region around rest wavelength H alpha, but superposed on this is the H alpha emission from the galaxy which, because the light is essentially monochromatic, results in a true two-dimensional image of the H alpha distribution. The visual appearance of the emission on the prism plates was classified according to its diffuseness on a 5 point scale (very diffuse, diffuse, intermediate, compact, and very compact). In tabular form, the relation is shown between this classification and a morphologically disturbed appearance for the galaxy.

Moss, C.↗

Requirements for long-life operation of inert gas hollow cathodes: Preliminary report

An experimental investigation was initiated to establish conditioning procedures for reliable hollow cathode operation via the characterization of critical parameters in a representative cathode test facility. From vacuum pumpdown rates, it was found that approximately 1.5 hours were required to achieve pressure levels within 5 percent of the lowest attainable pressure for this facility, depending on the purge conditions. The facility atmosphere was determined by a residual gas analyzer to be composed of primarily air and water vapor. The effects of vacuum pumping and inert gas purging were evaluated. A maximum effective leakage rate of 2.0 x 10(exp -3)sccm was observed and its probable causes were examined. An extended test of a 0.64 cm diameter Mo-Re hollow cathode was successfully completed. This test ran for 504 hours at an emission current of 23.0 amperes and a xenon flow rate of 6.1 sccm. Discharge voltage rose continuously from 15 to 21 volts over the course of the test. The temperature of the cathode body during the test was relatively stable at 1160 C. Post-test examination revealed ion-bombardment texturing of the orifice plate to be the only detectable sign of wear on the hollow cathode.

Verhey, Timothy R.↗

Requirements for long-life operation of inert gas hollow cathodes - Preliminary results

An experimental investigation was initiated to establish conditioning procedures for reliable hollow cathode operation via the characterization of critical parameters in a representative cathode test facility. From vacuum pumpdown rates, it was found that approximately 1.5 hours were required to achieve pressure levels within 5 percent of the lowest attainable pressure for this facility, depending on the purge conditions. The facility atmosphere was determined by a residual gas analyzer to be composed of primarily air and water vapor. The effects of vacuum pumping and inert gas purging were evaluated. A maximum effective leakage rate of 2.0 x 10 (exp -3) sccm was observed and its probable causes were examined. An extended test of a 0.64 cm diameter Mo-Re hollow cathode was successfully completed. This test ran for 504 hours at an emission current of 23.0 amperes and a xenon flow rate of 6.1 sccm. Discharge voltage rose continuously from 15 to 21 volts over the course of the test. The temperature of the cathode body during the test was relatively stable at 1160 C. Post-test examination revealed ion-bombardment texturing of the orifice plate to be the only detectable sign of wear on the hollow cathode.

Verhey, Timothy R.↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Discovery of 0.5 million K gas in the center of galaxy clusters

An observation of M 87, the central galaxy of the Virgo cluster, was performed in the 0.065 to 0.245 keV energy band by the Extreme Ultraviolet Explorer (EUVE). A central source and an extended emission halo are visible which represent the first detection of a cluster gas emission in the extreme ultraviolet. A gas component with a temperature of between 5 x 10(exp 5) and 10(exp 6) K has to be introduced in order to explain this emission. The rapid cooling of plasmas at such temperatures implies a mass accretion rate of greater than 300 solar mass/yr. Data from Rosat observations provide evidence of an extended central emission at 10(exp 6) K.

Lieu, R.↗

Enhancing CO 2 Mineralization Rate and Extent of Iron and Steel Slag via Grinding

Roughly 10% of the CO 2 emissions from iron and steel making are attributable to the direct release of CO 2 from the thermal decomposition of carbonates to produce flux, mainly CaO, used for impurity removal. Notably, these direct emissions remain even if carbon-based steelmaking is replaced by hydrogen-based steelmaking. After removing impurities from the molten metal, this flux becomes the solid waste product called ‘slag’, a primarily Ca-silicate material. The transformation of slag back into carbonates is thermodynamically spontaneous with negative ΔG in the ambient environment, meaning that ~10% of the CO 2 emissions from iron and steel making could be negated if equipment and methods were developed to support CO 2 mineralization. However, the rate of CO 2 mineralization using slag is slowed by several environmental, geometric, and processing factors. We leverage an experimentally verified model of CO 2 mineralization to determine how to efficiently accelerate the process. Increasing the crystallinity of slag, increasing the relative humidity, and reducing the grain size of slag particles provide the greatest increase in CO 2 mineralization rate at the lowest energy penalty. Increasing the concentration of CO 2 and the temperature provide only modest increases in the CO 2 mineralization rate while incurring a substantial energy penalty. For steelmaking slags, CO 2 mineralization represents low-hanging fruit as the current reuse pathways are low value. For ironmaking slag, replacing the production of amorphous slag for the cement industry with the production of crystalline slag for CO 2 mineralization becomes financially preferable when a carbon price/tax exceeds 67.40 USD/t-CO 2 .

42 ENGINEERING↗

Cassini and Wind Stereoscopic Observations of Jovian Non-Thermal Radio Emissions

During two intervals in 1999, simultaneous observations of Jupiter's decametric and hectometric radio emissions were made with the Cassini radio and plasma wave instrument (RPWS) and the radio and plasma wave instrument (WAVES) on the Wind spacecraft in Earth orbit. During January, the Jovian longitude difference between the two spacecraft was about 5 deg, whereas for the August-September Earth flyby of Cassini, the angle ranged from 0 deg to about 2.5 deg. With these separations, the instantaneous widths of the walls of the hollow conical radiation beams of some of the decametric arcs were measured suggesting that the typical width is approximately 2 deg. The conical beams seem to move at Io's revolution rate rather than with Jupiter's rotation rate. Additionally, some of the non-arc emissions have very narrow and quite peculiar beamwidths.

Kaiser, Michael L.↗