Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

A measurement of the absolute flux of cosmic-ray electrons

A balloon-borne superconducting magnet spectrometer was used to measure the absolute flux of cosmic-ray electrons. The instrument consisted of a gas Cerenkov detector, a momentum spectrometer, and a lead-scintillator shower counter. In order to determine electron flux in the interstellar medium, observed fluxes for energy loss in the atmosphere and the payload were corrected, taking into account solar modulation effects and bremsstrahlung energy losses. Fluxes were measured at an average atmospheric depth of 5.8 g/sq cm, and the solar modulation was 300 MeV. A cosmic-ray electron flux of 367 E to the exp(3.15 + or -0.2) per sq m/sr s GeV was obtained in the energy range 4.5-63.5 GeV. The uncertainty of the absolute (electron-positron) flux was 10 percent. A summary of the electron data is given in a table.

Golden, R. L.↗

Integrated Data Analysis to Improve Te and Zeff Measurement on NSTX-U

The multi-energy soft x-ray (ME-SXR) camera is a new concept for a fusion plasma diagnostic based on a pixelated detector with adjustable photon cutoff thresholds. It is a single, compact, solid-state detector which combines spatial and spectral sensitivity and can be configured remotely at run time, making it ideal for a fusion environment. The detector can be configured for application to a wide range of physics problems including impurity transport, electron temperature profiles, and non-thermal effects. The detector has been installed on the Madison Symmetric Torus (MST) as part of a collaboration between Princeton Plasma Physics Laboratory and the University of Wisconsin–Madison to develop the technology and analysis techniques. A full diagnostic forward model of the ME-SXR diagnostic has been developed to enable analysis of the raw photon count data. This model incorporates the atomic physics underlying the plasma emission, diagnostic geometry, and detector response characteristics. Employing this model, a Bayesian analysis approach is used to extract electron temperature from the raw data. This analysis approach uses all available information, clearly quantifies prior information, and handles uncertainties transparently. The ME-SXR camera is being used to study the 3D (helical, stellarator-like) state that forms in the MST device. This helical core structure has improved energy confinement. The transition to the helical state is accompanied by a rise in electron temperature in the central part of the helical structure, but then this enhancement fluctuates. The characteristics of this fluctuation are being compared to a magneto-hydrodynamics model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Pair Production Telescope for Medium-Energy Gamma-Ray Polarimetry

We describe the science motivation and development of a pair production telescope for medium-energy (approximately 5-200 Mega electron Volts) gamma-ray polarimetry. Our instrument concept, the Advanced Energetic Pair Telescope (AdEPT), takes advantage of the Three-Dimensional Track Imager, a low-density gaseous time projection chamber, to achieve angular resolution within a factor of two of the pair production kinematics limit (approximately 0.6 deg at 70 Mega electron Volts), continuum sensitivity comparable with the Fermi-LAT front detector (is less than 3 x 10(exp -6) Mega electron Volts per square centimeter per second at 70 Mega electron Volts), and minimum detectable polarization less than 10% for a 10 milliCrab source in 10(exp 6) s.

Gamma rays↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Inclusive Charged-Current Electron Neutrino Interactions in SBND

The Short-Baseline Near Detector (SBND), a 112 ton liquid argon time projection chamber (LArTPC), is the near detector of the Short- Baseline Neutrino Program at Fermilab. Due to its proximity to the Booster Neutrino Beam target, SBND has already seen a record-breaking number of electron neutrino interactions on argon. We present preliminary results from SBND’s differential inclusive electron neutrino charged-current analysis from our first year of beam data, selecting over 2,000 interactions. This analysis will present the largest sample of electron neutrinos on argon to date, as well as the first differential cross section measurement of electron neutrinos. This poster will give an overview of the selection, cross-section extraction, and demonstrate SBND’s detector and electromagnetic shower reconstruction performance through data/MC comparisons.

Tung, Lynn [Chicago U.]↗

Performance of the Three-Dimensional Track Imager (3-DTI) for Gamma-Ray Telescopes

We have been developing a gas time projection chamber for the imaging of gamma-rays between 0.3 - 50 MeV, the Three-Dimensional Track Imager (3DTI). The detector is being designed for use on satellite experiments for the imaging of astrophysical gamma-ray sources. Electrons produced by pair production or Compton scattering ionize the gas and these ionization electrons are detected by the cross-strip micro-well detector at the bottom of the chamber. Discrete component of front end electronics and time digitization electronics have been developed. We will present results of prototype microwell detector and laboratory set-up in various gas mixtures.

Son, Seunghee↗

Performance of the wavelength-shifting fiber upgrade for the Mu2e cosmic-ray veto detector

The Cosmic-Ray Veto detector for the muon-to-electron conversion experiment at Fermilab consists of four plastic scintillating counter layers read out by silicon photo-multipliers through embedded wavelength-shifting fibers. In order to increase the light yield in the most critical regions of the Cosmic-Ray Veto detector for improved background rejection, a 1.8 mm diameter fiber is being used in many of the detector's critical modules instead of the previously planned 1.4 mm diameter fiber. This paper reports the testing procedure and light properties of thirty-four 1.8 mm fiber spools, with measurements performed using a custom-built scanner. We compare these new results with previously published data from the 1.4 mm diameter fiber used for regions of the cosmic-ray veto where the increased light yield is not required. In addition, measurements of fiber aging were performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Compact Electron-Proton Spectrometer for Moon / Mars Surface Space Weather Monitoring and Crew Protection (CEPS)

Small mass/low-power sensors are needed for autonomous Moon/Mars surface ops that provide alerts to impending adverse space weather conditions. In order to use current operational forecasting tools, a sensor capable of measuring both high-energy electrons and protons is needed. By combining high-TRL Timepix technology with a CdTe layer, this project leverages known technology to fill a critical gap for surface operations. Typical space weather sensors are at least an order of magnitude higher in mass than is expected from Timepix-based devices and are deployed on robotic assets away from human crews. High fidelity measurements at the crew location and subsequent ability are needed to provide warnings to crews to shelter with a device that can easily be carried on the Lunar and Martian surfaces.​ The aim of this project is the development of compact, low power space weather sensors for crew protection based on the combination of AES flight heritage Timepix hardware with novel CdTe (Cadmium Telluride) sensors. CdTe technology has only recently matured to a point where it can be reliably used with Timepix detectors. These detectors will be able to measure electron spectra in an energy range relevant to the RELEASE model, which is used operationally by NASA to provide crew early warning of Solar Energetic Particle Events as well as protons in the energy ranges relevant to human health allowing for event ‘nowcasting’ and total event crew dose prediction. Compared to existing solutions these detectors will be compact enough to travel with crew, providing a significant advantage to space environment situation awareness. Project results indicate that CdTe-based Timepix sensors respond well to energetic electrons, and particle tracks are sufficiently distinct to be able to measure in a mixed radiation field. Thermal testing results point to a needed design modification to mitigate high temperatures the detector will see in space. Radiation susceptibility testing was conducted to assess the radiation hardness of the CdTe-Timepix assembly. Overall, the assembly continued to operate up to 100 kRad of gamma-ray exposure. The system calibration did show drift over time but recovered once exposure was complete.

Dan James Fry↗

Towards a numu CC exclusive cross section measurement with one proton and one muon in the final state at the NOvA near detector

NOvA is a long-baseline neutrino experiment at Fermilab that studies neutrino oscillations via electron neutrino appearance and muon neutrino disappearance. The NOvA Near Detector, located 1 km from the NuMI target, records a high rate of neutrino interactions in the energy range of 1-5 GeV. One of the limitations in precise extraction of oscillations is the large systematic uncertainty on neutrino-nucleus interactions. The high rate of neutrino interactions in the NOvA Near Detector provides the opportunity to probe various neutrino interaction processes and nuclear models, via the extraction of cross sections of particular final states. Nuclear models can be improved by measuring neutrino-nucleus cross sections with respect to kinematic variables which are known to be more sensitive to nuclear effects, such as transverse kinematic imbalance (TKI) variables. Usage of TKI variables allows for more direct constraints on models of neutrino scattering, as these variables can more directly investigate, for instance, effects of Fermi motion and final state interactions. In this work, we describe progress towards a method of identifying and reconstructing protons in the NOvA near detector to enable the cross section measurement of charged current neutrino interactions with a visible muon and a proton in the final state, reported in TKI variables.

Weber, Colin [Minnesota U.] (ORCID:000000031117067↗

First demonstration of 30 eVee ionization energy resolution with RICOCHET germanium cryogenic bolometers

The future RICOCHET experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the RICOCHET collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics with a total input capacitance of about 40 pF. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar phonon-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector with a total input capacitance of 250 pF. Additionally, we discuss the implications of these results in the context of the future RICOCHET experiment and its expected background mitigation performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resolving the Electron Plume within a Scanning Electron Microscope

Scanning electron microscopy (SEM), a century-old technique, is today a ubiquitous method of imaging the surface of nanostructures. However, most SEM detectors simply count the number of secondary electrons from a material of interest, and thereby overlook the rich material information contained within them. Here, by simple modifications to a standard SEM tool, we resolve the momentum and energy information on secondary electrons by directly imaging the electron plume generated by the electron beam of the SEM. Leveraging these spectroscopic imaging capabilities, our technique is able to image lateral electric fields across a prototypical silicon p–n junctions and to distinguish differently doped regions, even when buried beyond depths typically accessible by SEM. Intriguingly, the subsurface sensitivity of this technique reveals unexpectedly strong surface band bending within nominally passivated semiconductor structures, providing useful insights for complex layered component designs, in which interfacial dynamics dictate device operation. Further, these capabilities for noninvasive, multimodal probing of complicated electronic components are crucial in today’s electronic manufacturing but is largely inaccessible even with sophisticated techniques. These results show that seemingly simple SEM can be extended to probe complex and useful material properties.

36 MATERIALS SCIENCE↗

RAPID: The imaging energetic particle spectrometer on Cluster

The RAPID spectrometer for the Cluster mission, an advanced particle detector for the analysis of suprathermal plasma distributions in the energy range from 20 to 400 keV and from 2 keV/nuc to 1500 keV for electrons and ions, respectively, is presented. Novel detector concepts in combination with pinhole acceptance permit the measurement of angular distributions over a range of 180 deg in polar angle for either species. The detection principle for the ionic component is based on a two dimensional analysis of a particle's velocity and energy. Electrons are identified by the well known energy range relationship. The detection techniques are described and selected areas in geospace are used to highlight the scientific objectives of this investigation.

Wilken, B.↗

Study of meteoroid detection systems applicable to the outer planets missions

Modifications to the Pioneer 10/11 meteoroid detection experiment to allow it to be used for outer planet missions were investigated. Both pressurized cells and metal-oxide silicon (MOS) penetration detectors are considered. Both the sensors systems and the electronics are treated. Investigation of the calibration and characterization of the MOS penetration detector is reported.

Brooks, A. D.↗

Inspection Tools

A "NASA Tech Briefs" article describing an inspection tool and technique known as Optically Stimulated Electron Emission (OSEE) led to the formation of Photo Acoustic Technology, Inc. (PAT). PAT produces sensors and scanning systems which assure surface cleanliness prior to bonding, coating, painting, etc. The company's OP1000 series realtime pre-processing detection capability assures 100 percent surface quality testing. The technique involves brief exposure of the inspection surface to ultraviolet radiation. The energy interacts with the surface layer, causing free electrons to be emitted from the surface to be picked up by the detector. When contamination is present, it interferes with the electron flow in proportion to the thickness of the contaminant layer enabling measurement by system signal output. OP1000 systems operate in conventional atmospheres on all types of material and detect both organic and inorganic contamination.

Source record↗

The Zero-Degree Detector System

We will report on a detector system used for accelerator measurement of nuclear fragmentation cross sections. This system consists of two detector planes, each carrying a ring of 8 detectors. Each detector has 64 pads. These two detector planes are arranged facing each other so that the matching detector pads on each plane form a two element charged particle telescope. Each of these telescopes is capable of determining the elemental identity of nuclear fragments passing through it. The system is used to measure light fragment production in the presence of heavier fragments. We will present a detailed discussion of the 64-pad detector design, the substrate design. The front-end electronics used to read out the signals is based on a custom VLSI chip developed for the Advanced Thin Ionization Calorimeter experiment which has been flown successfully twice in Antarctica. Each of these chips has 16 channels and each channel consists of a charge-sensitive preamplifier followed by a shaping amplifier and a track-and-hold circuit. The track-and-hold circuits are connected via a multiplexer to an output line driver. This allows the held signals to be presented, one-by-one via a common data line to a analog-to-digital converter. Because the output line driver can be placed in a high input impedance state when not in use, it is possible to daisy-change many chips on the same common data line. The front-end electronics and data readout scheme will be discussed in detail. The Zero Degree Detector has been used in several accelerator experiments conducted at the NASA Space Radiation Laboratory and the Alternating Gradient Synchrotron at Brookhaven National Laboratory as well as at the HIMAC accelerator in Japan. We will show examples of data taken at these accelerator runs to demonstrate how the system works.

Adams, James H.↗

Search for Accelerator-Produced Sub-GeV Dark Matter with the NOvA Near Detector

The NuMI facility at Fermilab produces a high-intensity beam of muon neutrinos and antineutrinos, designed to study neutrino oscillations. This beam may also be a source of dark matter particles produced through a light mediator. We search for dark matter particles with masses between 1 and 200 MeV that interact with Standard Model particles via a vector portal, producing forward-scattered single-electron events in the NOvA near detector. We set limits on the dark-visible coupling based on an exposure of 2.55x10^21 protons of 120 GeV energy on the NuMI target. For the dark matter mass range 10-20 MeV, this analysis sets the tightest constraints on the coupling to date.

Abubakar, S. [Erciyes U.] (ORCID:0000000315112219)↗

Accurate determination of the electron spin polarization in magnetized iron and nickel foils for Møller polarimetry

The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades. Past experiments have typically required polarimetry at the 1% level of absolute uncertainty which the Møller polarimeter has delivered. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4% (The MOLLER Collaboration, 2014; The SoLID collaboration, 2019), requiring a systematic re-examination of all the contributing uncertainties. Møller polarimetry uses the double polarized scattering asymmetry of a polarized electron beam on a target with polarized atomic electrons. The target is a ferromagnetic material magnetized to align the spins in a given direction. In Hall A, the target is a pure iron foil aligned perpendicular to the beam and magnetized out of plane parallel or antiparallel to the beam direction. The acceptance of the detector is engineered to collect scattered electrons close to 90° in the center of mass frame where the analyzing power is a maximum (-7/9). One of the leading systematic errors comes from determination of the target foil polarization. Polarization of a magnetically saturated target foil requires knowledge of both the saturation magnetization and g', the electron g-factor which includes components from both spin and orbital angular momentum from which the spin fraction of magnetization is determined. Target foil polarization has been previously addressed in a 1997 publication “A precise target for Møller polarimetry” by de Bever et al. (1997) at a level of precision sufficient for experiments up to this point. Several shortcomings with the previous published value require revisiting the result prior to MOLLER. Here, we utilize the existing world data to provide a best estimate for target polarization for both nickel and iron foils including uncertainties in magnetization, high-field and temperature dependence, and fractional contribution to magnetization from orbital effects. We determine the foil electron spin polarization at 294 K to be 0.08020 ± 0.00018 (@4 T applied field) for iron and 0.018845+/-0.000053 (@2 T applied field) for nickel. Finally, we conclude with a brief discussion of additional systematic uncertainties to Møller polarimetry using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GaAs/AlGaAs superlattice miniband detector with 14.5 microns peak response

Extended long wavelength infrared detection with a miniband-type AlGaAs/GaAs superlattice structure is reported. The experimental response band of the detector is peaked near 14.5 microns in good agreement with the theoretical response, provided that electron-elecltron interactions are taken into account. The detector operates at a low bias voltage, which could lead to important advantages in application to IR focal plane arrays.

Bandara, K. M. S. V.↗