Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Catalyzing Disruptive Mobility Opportunities Through Transformational Aviation Power

Lightweight, efficient power production has been a pacing technology for aviation. Advances in airborne electric propulsion technology have enabled new aviation concepts in markets that previously were not dominated by aviation systems, largely because electric propulsion allows for efficient, integrated propulsion/aerodynamic/control solutions that were previously not practical with combustion-based power architectures. These new markets include automated package delivery, urban air mobility, and short-haul transportation. As these markets evolve, the impact of using electricity for airborne propulsion on an expanding mission set, as well as the sheer amount of energy consumed, will begin to challenge the energy harvesting and distribution paradigm as it exists today. Left unaddressed, these challenges could stymie the evolution of these new markets and mobility options. This paper identifies some of the potential systemic issues associated with the expanded use of electric propulsion and explores the requirements associated with alternate aviation power architectures. The recommended path includes the development of a new hybrid-electric aviation power architecture that can be used in conjunction with a portfolio of evolving battery-electric and combustion-based systems.

Borer, Nicholas K.↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗

Analysis of Multi-Output Hybrid Energy Systems Interacting with the Grid: Application of Improved Price-Taker and Price-Maker Approaches to Nuclear-Hydrogen Systems

The growing recognition of the value of hydrogen as an energy intermediate in supporting future power systems with high shares of variable renewable energy has prompted many studies to quantify the economic potential of multi-output hybrid systems, which are one type of integrated energy systems (IES). Because of the complexity of modeling multiple sectors, these studies typically use simplified modeling approaches to capture the interactions between sectors. In this study, we explore the implications of alternative modeling approaches for nuclear-hydrogen IES focusing on a power system in the Midwest United States. We combine highly resolved capacity expansion and production cost modeling tools of the power system with a detailed hydrogen system optimization tool to determine the optimal electrolyzer and storage sizing and optimal operations of the nuclear-hydrogen hybrid resource across three future study years. We compare economic and operational outcomes across a spectrum of modeling approaches, including a non-hybridized base approach; a traditional price-taker approach that does not include the impact of hydrogen production on the electricity system; a power-system-focused price-maker approach that does not account for temporal hydrogen constraints; and two improved price-taker and price-maker approaches that each address the impact of revenue-optimal levels of electricity production on the resulting power system and temporal hydrogen constraints on the overall feasible solution. Results show how a traditional price-taker approach can overestimate the economic benefits of multi-output nuclear-hydrogen IES compared to our two improved approaches that estimate both hydrogen system constraints and power system interaction. We find that hydrogen output requirements and storage size limits are key drivers to overall operations and some economic outcomes. Under our assumed constant hydrogen output requirement, storage costs, test system, and modeling approaches, our results indicate that hybridization can provide a net benefit, but results are sensitive to the treatment of hydrogen revenues and electricity prices as impacted by the power system evolution.

capacity expansion modeling↗

A novel photonic oscillator

We report a novel oscillator for photonic RF systems. This oscillator is capable of generating high-frequency signals up to 70 GHz in both electrical and optical domains and is a special voltage-controlled oscillator with an optical output port. It can be used to make a phase-locked loop (PLL) and perform all functions that a PLL is capable of for photonic systems. It can be synchronized to a reference source by means of optical injection locking, electrical injection locking, and PLL. It can also be self-phase locked and self-injection locked to generate a high-stability photonic RF reference. Its applications include high-frequency reference regeneration and distribution, high-gain frequency multiplication, comb-frequecy and square-wave generation, carrier recovery, and clock recovery. We anticipate that such photonic voltage-controlled oscillators (VCOs) will be as important to photonic RF systems as electrical VCOs are to electrical RF systems.

Yao, X. S.↗

ISS And Space Environment Interactions Without Operating Plasma Contactor

The International Space Station (ISS) will be the largest, highest power spacecraft placed in orbit. Because of this the design of the electrical power system diverged markedly from previous systems. The solar arrays will operate at 160 V and the power distribution voltage will be 120 V. The structure is grounded to the negative side of the solar arrays so under the right circumstances it is possible to drive the ISS potential very negative. A plasma contactor has been added to the ISS to provide control of the ISS structure potential relative to the ambient plasma. The ISS requirement is that the ISS structure not be greater than 40 V positive or negative of local plasma. What are the ramifications of operating large structures with such high voltage power systems? The application of a plasma contactor on ISS controls the potential between the structure and the local plasma, preventing degrading effects. It is conceivable that there can be situations where the plasma contactor might be non-functional. This might be due to lack of power, the need to turn it off during some of the build-up sequences, the loss of functionality for both plasma contactors before a replacement can be installed, similar circumstances. A study was undertaken to understand how important it is to have the contactor functioning and how long it might be off before unacceptable degradation to ISS could occur. The details of interaction effects on spacecraft have not been addressed until driven by design. This was true for ISS. If the structure is allowed to float highly negative impinging ions can sputter exposed conductors which can degrade the primary surface and also generate contamination due to the sputtered material. Arcing has been known to occur on solar arrays that float negative of the ambient plasma. This can also generate electromagnetic interference and voltage transients. Much of the ISS structure and pressure module surfaces exposed to space is anodized aluminum. The anodization thickness is very thin to provide the required solar absorptance and emittance. For conditions where ISS structure can charge negative a large percentage of the array voltage, the dielectric strength of this layer is low, and dielectric breakdown (arcing) can occur. The energy stored capacitively in the structure can be delivered to the arc. The mechanisms by which this energy is delivered and how much of the energy is available hasn't been fully quantified. Questions have been raised regarding the possibility of whether a sustained arc might result due to current collected by the solar arrays from local plasma. It was postulated that even if dielectric breakdown didn't occur, impacts due to micrometeoroids and space debris could penetrate thin layers of dielectric on ISS and initiate an arc due to the coupling provided by the dense local plasma produced by the impact. This was proven in experiments conducted jointly by MSFC and Auburn University. A target chamber with a simulated ionospheric plasma and a biased, anodized aluminum plate and a 1-microfarad capacitor was used. The plate was then impacted by 75-micron particles accelerated to orbital velocity. Arc discharges were sustained for higher voltages but a threshold appears below which no discharge was initiated. Most items without an exposed power system will float electrically near the local plasma potential. This is true of the Space Shuttle, an Astronaut on EVA, and similar items. The structure of ISS might be at a large negative voltage. Therefore, capacitively stored energy can be transferred during docking, installing external boxes and equipment and Astronaut contact with ISS structure. The circumstances of when this can happen and the resulting effects are evaluated in this study. Also, a crewmember on EVA might be in the vicinity of an arc. All safety aspects of such an encounter including charging, molten particles from the arc site and EMI have been evaluated. This paper will report on the total results of this study focussed on the 4A configuration, scheduled to be complete in November, 2000. Interactions such as arcing, debris induced arcs, sustained arcs, sputtering, contamination from sputtering and arcing, docking interactions and Astronaut safety issues will all be addressed.

Carruth, M. R., Jr.↗

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains - Task 2: Power Quality Filtering Using Nanocrystalline Soft Magnetic Inductor

The NASA RTAPS program on AC and DC Fault Management for Megawatt Electrified Power Train is a multi-year joint project with Pratt & Whitney (P&W), Collins Aerospace (CA), and RTX Technology Research Center (RTRC). This research program focuses on the high-voltage distribution issues that present a significant technological obstacle in the adoption of Electrified Aviation Propulsion (EAP) systems. One challenge to the adoption of high-voltage distribution systems with power electronic converters is the need for filter elements to limit the generation and propagation of noise, protect the cable systems from premature aging and prevent against excessive heating within subcomponents due to high-frequency induced currents. While increased distribution voltages aide in reducing the cable mass for a fixed power system, the associated mass with the filtering elements for power electronic converter can grow with increasing distribution voltages – thereby mitigating any benefit associated with increasing the distribution system voltage. To enable high-voltage distribution systems with high system specific power densities, new magnetic materials must be developed. Therefore, the second task of the NASA RTAPS program is associated with the design and application of advanced soft magnetic components for Megawatt class electric propulsion systems, specifically the motor drive system. This report covers the collaborative work between NASA Glenn Research Center (GRC), RTRC, P&W and CA in the development of three types of magnetic components over the span of the three-year program. These critical magnetic components are the DC side EMI filter, which limits the propagation of harmful electromagnetic noise to the rise of the distribution system, and the AC side damping with the dv/dt filter, which limits the fast rise time of the power electronic converter output voltage to limit the degradation on the cable/motor insulation systems. Each of these components are investigated from component level design and are optimized at the system level with a combined modelling and testing effort. In the final experimental evaluation of the NASA developed soft magnetic material with a dv/dt filter, a commercial-off-the-shelf (COTS) magnetic core and the GRC magnetic core are optimized and loaded at 320Arms to evaluate their difference in performance. After a run time of 30 minutes in a MW-class motor driver at RTRC, the NASA GRC cores were found to not only offer a lower temperature rise of nearly 25°𝐶, but also a reduction in measured core loss of 25% (12.75W to 9.5W).

Elecrified Aircraft Propulsion↗

Technique for Solving Electrically Small to Large Structures for Broadband Applications

Fast iterative algorithms are often used for solving Method of Moments (MoM) systems, having a large number of unknowns, to determine current distribution and other parameters. The most commonly used fast methods include the fast multipole method (FMM), the precorrected fast Fourier transform (PFFT), and low-rank QR compression methods. These methods reduce the O(N) memory and time requirements to O(N log N) by compressing the dense MoM system so as to exploit the physics of Green s Function interactions. FFT-based techniques for solving such problems are efficient for spacefilling and uniform structures, but their performance substantially degrades for non-uniformly distributed structures due to the inherent need to employ a uniform global grid. FMM or QR techniques are better suited than FFT techniques; however, neither the FMM nor the QR technique can be used at all frequencies. This method has been developed to efficiently solve for a desired parameter of a system or device that can include both electrically large FMM elements, and electrically small QR elements. The system or device is set up as an oct-tree structure that can include regions of both the FMM type and the QR type. The system is enclosed with a cube at a 0- th level, splitting the cube at the 0-th level into eight child cubes. This forms cubes at a 1st level, recursively repeating the splitting process for cubes at successive levels until a desired number of levels is created. For each cube that is thus formed, neighbor lists and interaction lists are maintained. An iterative solver is then used to determine a first matrix vector product for any electrically large elements as well as a second matrix vector product for any electrically small elements that are included in the structure. These matrix vector products for the electrically large and small elements are combined, and a net delta for a combination of the matrix vector products is determined. The iteration continues until a net delta is obtained that is within the predefined limits. The matrix vector products that were last obtained are used to solve for the desired parameter. The solution for the desired parameter is then presented to a user in a tangible form; for example, on a display.

Jandhyala, Vikram↗

Design Considerations for Distributed Energy Resource Honeypots and Canaries

There are now over 2.5 million Distributed Energy Resource (DER) installations connected to the U.S. power system. These installations represent a major portion of American electricity critical infrastructure and a cyberattack on these assets in aggregate would significantly affect grid operations. Virtualized Operational Technology (OT) equipment has been shown to provide practitioners with situational awareness and better understanding of adversary tactics, techniques, and procedures (TTPs). Deploying synthetic DER devices as honeypots and canaries would open new avenues of operational defense, threat intelligence gathering, and empower DER owners and operators with new cyber-defense mechanisms against the growing intensity and sophistication of cyberattacks on OT systems. Well-designed DER canary field deployments would deceive adversaries and provide early-warning notifications of adversary presence and malicious activities on OT networks. In this report, we present progress to design a high-fidelity DER honeypot/canary prototype in a late-start Laboratory Directed Research and Development (LDRD) project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Projection of distributed-collector solar-thermal electric power plant economics to years 1990-2000

A preliminary comparative evaluation of distributed-collector solar thermal power plants was undertaken by projecting power plant economics of selected systems to the 1990 to 2000 time frame. The selected systems include: (1) fixed orientation collectors with concentrating reflectors and vacuum tube absorbers, (2) one axis tracking linear concentrator including parabolic trough and variable slat designs, and (3) two axis tracking parabolic dish systems including concepts with small heat engine-electric generator assemblies at each focal point as well as approaches having steam generators at the focal point with pipeline collection to a central power conversion unit. Comparisons are presented primarily in terms of energy cost and capital cost over a wide range of operating load factors. Sensitvity of energy costs for a range of efficiency and cost of major subsystems/components is presented to delineate critical technological development needs.

Fujita, T.↗

High temperature antenna development for space shuttle, volume 1

Design concepts for high temperature flush mounted Space Shuttle Orbiter antenna systems are discussed. The design concepts include antenna systems for VHF, L-band, S-band, C-band and Ku-band frequencies. The S-band antenna system design was completed and test hardware fabricated. It was then subjected to electrical and thermal testing to establish design requirements and determine reuse capabilities. The thermal tests consisted of applying ten high temperature cycles simulating the Orbiter entry heating environment in an arc tunnel plasma facility and observing the temperature distributions. Radiation pattern and impedance measurements before and after high temperature exposure were used to evaluated the antenna systems performance. Alternate window design concepts are considered. Layout drawings, supported by thermal and strength analyses, are given for each of the antenna system designs. The results of the electrical and thermal testing of the S-band antenna system are given.

Kuhlman, E. A.↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

Rapid deployment of residential photovoltaic (PV) systems helps decarbonize our electricity supplies, but under certain circumstances, high-penetration PV may pose challenges to the electrical distribution grid. In a project funded by the U.S. Department of Energy's Solar Energy Technologies Office and Building Technologies Office, the National Renewable Energy Laboratory and its partners studied how flexible building loads and battery storage, when coordinated at home-level and community-level scales, can be used to address those challenges and enhance grid resilience. In this webinar, we will discuss the methodology, simulation and field pilot results, insights from partners, and lessons learned from the project.

artificial intelligence↗

An Evaluation of Co-Simulation for Modeling Coupled Natural Gas and Electricity Networks

Reliance on natural gas for power generation has increased the coupling between gas and power networks. While this coupling can bring operational and economic benefits, it can also yield challenges, as the constraints in one system can impact the other. Co-simulation can capture the constraints and interactions between these systems, but so far, there has been limited comparison of co-simulation results to those of an integrated model. In this work, we develop a new co-simulation framework using the HELICS platform and the SAInt tool for modeling transient gas and AC optimal power flow. We evaluate this co-simulation framework against a fully integrated version of the SAInt power and gas simulators, thus providing a benchmarking of the co-simulation approach. We compare results across the two approaches for two test networks and a network representing the Belgian power and gas networks, testing both normal operating conditions and cases with compressor disruptions. In each of the cases tested, we find nearly identical results from the two approaches across various metrics of interest, such as nodal pressure, gas flow rates, and active power generation. This alignment suggests that co-simulation can yield comparable results to fully integrated models for modeling coupled gas and electricity networks.

03 NATURAL GAS↗

Hydrogen and Battery Storage Technologies for Low-Cost Energy Decarbonization in Distribution Networks

Deep energy decarbonization cannot be achieved without high penetration of renewables. At higher renewable energy penetrations, the variability and intermittent nature of solar photovoltaic (PV) electricity can cause ramping issues with existing fossil fuel generation, requiring longer term energy storage to increase the reliability of grid operation. Here, a proton exchange membrane electrolyzer can produce H 2 and serves as a utility controllable load. The produced H 2 can then be stored and converted back into electricity, or mixed with natural gas, or used as transportation fuel, or chemical feedstock. This paper considers the perspective of the distribution system operator that operates the distributed energy resources on a standard IEEE 33-node distribution network considering the technical and physical constraints with the goal of minimizing total investment and operation cost. Different case studies, at very high PV penetrations are considered to show the challenges and path to net-zero emission energy production using H 2 energy. Sensitivity of utility PV costs and electrolyzer capital costs on producing H 2 at $\$1$ /kg are presented showing that the distribution network could produce 100% renewable electricity and H 2 could be produced at a cost of $\$1$ /kg by 2050 with conservative cost estimates and by 2030 with accelerated cost declines.

25 ENERGY STORAGE↗

Improvements in and test results for the 2 to 15 kilowatt Brayton cycle electrical subsystem

The electrical subsystem of the 2- to 15-kW Brayton power conversion system consists of the auxiliary electrical equipment required for an integrated, self-contained system. For the last 2 years the electrical subsystem has been undergoing extensive tests. The first year of testing resulted in determining the performance characteristics of the electrical subsystem. During the second year several significant changes and improvements were investigated. An inverter designed for motor starting the alternator performed successfully. Some of the changes that have been made are a new alternator speed pickup, which is independent of the alternator output voltage; new, more efficient power supplies for the control system; and a volts-per-hertz reference for the alternator voltage regulator. Test data were taken on the temperature distribution of the electrical subsystem at startup conditions over a cold-plate temperature range of 25 to -50 C.

Vrancik, J. E.↗

CCE Case Study: Baltavia Substation Power Outage

In this case study, we will examine a fictional event broadly inspired by the real power outages in Ukraine that took place in December 2015 and December 2016—both the result of cyber-enabled sabotage. The actual events of 2015 and 2016 were well-documented—the adversaries in these attacks gained access to a few power companies’ corporate networks, pivoted to industrial control system (ICS) networks, and created widespread physical effects in the form of power outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feasibility Analyses for the Microgrid of the Mountain in the Cordillera Central Region of Puerto Rico

Distributed energy resource (DER) development can benefit communities through improvement of access to reliable electricity and a resilient energy system. Many place-specific considerations must be accounted for when designing electrical systems with co-located generation and loads. This paper presents an overview of four studies focusing on different aspects for regional DER development in the Cordillera Central region of Puerto Rico, including a grid and load stability study with the introduction of solar energy generation, microgrid design based on the solar resource in the area, resilience considerations during power outage scenarios, and qualitative risk aspects for components in the microgrid. Additionally, a conceptual substation microgrid analysis is conducted using the Microgrid Design Toolkit (MDT) to evaluate trade-offs between cost and energy availability, providing insights into optimal design strategies. A microgrid resilience assessment is performed using the Resilient Nodal Cluster Analysis Tool (ReNCAT) to identify critical loads and evaluates their accessibility during outages, emphasizing the importance of community needs. Finally, a qualitative risk assessment utilizing Hazard and Operability Analysis (HAZOP) methods highlights potential hazards and mitigations for microgrid components, ensuring robust system design and operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incorporating Valve Switching Losses Into a Static Optimal Control Algorithm for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) has, in recent years, been proposed as an energy efficient alternative to conventional load-sensing architectures in mobile machines such as excavators and wheel-loaders. HHEA leverages the advantages of hydraulic power and electric power to eliminate throttling valves while also improving the energy and control performance of the system. The architecture utilizes a set of common pressure rails to provide a majority of power and and a small electric motor driven pump to modulate this power to meet the exact demand. Previous work has developed a computationally efficient Lagrange Multiplier approach for determining the optimal pressure rail selections that minimizes the energy losses in the system. The static model used considers only the energy use for each pressure rail selection but not the losses associated with the valves during the transition. This paper presents an approach to include the switching losses in the model and in the optimization procedure. To capture the switching losses, switching events between different rails and at various input and output flow rates were simulated with consideration of valve spool dynamics. A parameterized model that summarizes the losses is then obtained, allowing switching losses to be added to the previous energy analysis. The performance of the switching loss model was compared with reference data obtained from a high-fidelity simulation model. To incorporate the switching losses into optimal control algorithm, an efficient dynamic programming approach that prevents frequent switching is adopted in place of the Lagrange multiplier approach. The overall effect of switching losses on the energy consumption and optimal control decisions is presented. In general, switching losses contribute to about 9–10% of input energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic simulation of occupant-driven energy use in a bottom-up residential building stock model

The residential buildings sector is one of the largest electricity consumers worldwide and contributes disproportionally to peak electricity demand in many regions. Strongly driven by occupant activities, household energy consumption is stochastic and heterogeneous in nature. However, most residential energy models applied by industry use homogeneous, deterministic activity schedules, which work well for predictions of annual energy consumption, but can result in unrealistic hourly or sub-hourly electric load profiles, with exaggerated or muted peaks. The increasing proportion of variable renewable energy generators means that representing the heterogeneity and stochasticity of occupant behavior is now crucial for reliable planning at both bulk-power and distribution-system scales. This work presents a novel and open-source occupancy simulation approach that can simulate a diverse set of individual occupant and household event schedules for all major electricity, fuel, and hot water end uses. To accomplish this, we evaluated three alternative occupant activity simulation approaches before selecting a hybrid combining time-inhomogeneous Markov chains and probability-sampling of event durations and magnitudes. Further, we integrated the stochastic occupancy simulation with an open-source bottom-up physics-simulation building stock model and published a set of 550,000 diverse household end-use activity schedules representing a national housing stock. The simulator was verified against time-use survey data, and simulation results were validated against measured end-use electricity data for accuracy and reliability. While we use data for the United States, our application demonstrates how similar approaches could be applied using the time-use survey data collected in many countries around the world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗