Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Charging location selection of an incoming electric vehicle for large EV depot infrastructure

As the use of renewable energy resources increases within charging infrastructures, the risk that charging an additional load within the charging infrastructure will create a violation of the applicable grid code also increases. In an embodiment, a charging location is selected for an incoming load based on a load flow analysis, to thereby mitigate the risk of a violation. This selection process may also account for the charging schedule of the load and the capacity of available charging stations (e.g., fast charging vs. slow charging).

Hafiz, Faeza↗

2022 Summer Resource Adequacy in the ERCOT Region

This report is a 2022 update to the National Energy Technology Laboratory (NETL) report that examined the potential system performance of the Electric Reliability Council of Texas (ERCOT) system during the summer of 2021. Anticipated summer reserve margins in ERCOT have risen year-over-year from the 15.7 percent reported in ERCOT’s Final Seasonal Assessment of Resource Adequacy (SARA) for Summer 2021 to 22.8 percent in the Final SARA for Summer 2022, driven mostly by increases in wind and solar generation. Using data from ERCOT’s 2022 Summer SARA, Capacity, Demand and Reserves (CDR) reports, and historical performance data obtained from ERCOT and Hitachi Energy Velocity Suite, six economic dispatch scenarios using PROMOD were developed to assess the risk to ERCOT of a load shedding event for Summer 2022. The results suggests that ERCOT may be facing a very tight resource adequacy situation, with the potential for a serious shortfall during the summer peak, usually the end of July through mid-August, if demand and generator outage rates significantly exceed peak levels. Under these conditions, ERCOT will need to call on its operating tools, including Energy Emergency Alerts (EEA) and calls to conserve electricity, to maintain reliability and continue serving load. Those measures alone may not be sufficient to avert a shedding of load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗

Techno-Economic Analysis of a Thermally Integrated Solid Oxide Fuel Cell and Compressed Air Energy Storage Hybrid System

Natural-gas-fueled solid oxide fuel cell (SOFC) systems have the potential for high-efficiency conversion of carbon to power due to the underlying electrochemical conversion process while readily facilitating carbon capture through the separation of the fuel and oxidant sources. Compressed air energy storage (CAES) technology can potentially store significant quantities of energy for later use with a high round-trip efficiency and lower cost when compared with state-of-the-art battery technology. The base load generation capability of SOFC can be coupled with CAES technology to provide a potentially flexible, low-carbon solution to meet the fluctuating electricity demands imposed by the increasing share of intermittent variable renewable energy (VRE) production. SOFC and CAES can be hybridized through thermal integration to maximize power output during periods of high electrical demand and then store power when either demand is low or renewable generation reduces power prices. The techno-economics of a low-carbon hybrid SOFC and CAES system was developed and investigated in the present study. The proposed hybrid system was found to be cost-competitive with other power-generating base-load facilities when power availability was considered. The hybrid system shows increased resilience to changes in a high VRE grid market scenario.

25 ENERGY STORAGE↗

Fast Charging Infrastructure for Electrifying Road Trips to and from National Parks in the Western United States

This study investigated the fast-charging infrastructure needed by 2030 to enable seamless electrified road trips to and from national parks and monuments in seven western states: Washington, Oregon, Idaho, Wyoming, Utah, Nevada, and Arizona. It also estimated impacts to the electric grid. The research team investigated how on-route charging infrastructure projections change with different parameters or assumptions, as do related charging loads and grid impacts. NREL conducted the study in partnership with utility service provider PacifiCorp and Utah State University as part of the Western Smart Regional EV Adoption and Infrastructure at Scale project.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

A data-driven model for thermodynamic properties of a steam generator under cycling operation

The varying electricity demand from coal power plants due to the intermittent nature of renewable sources leads to load-follow and on/off operations referred to as cycling. Cycling causes transients of properties such as pressure and temperature within various components of the steam generation system.These transients cause increased damage because of fatigue and creep-fatigue interactions shortening the life of components. An algorithm is developed to identify cycling operations from the gross power data. The data-driven model based on artificial neural networks (ANN) is developed using 10 years data from Coal Creek Station power plant located in North Dakota, USA to estimate properties of the steam generator components during cycling operations. Furthermore, the uniqueness of this model is the ability to predict component properties for the cycling as well as base-load operations and is reported for the first time. The ANN model estimates the component properties, for a given gross power profile and initial conditions, as they vary during cycling operations. As a representative example, the ANN estimates are presented for the superheater outlet pressure, reheater inlet temperature, and flue gas temperature at the air heater inlet. The changes in these variables as a function of the gross power over the time duration are compared with measurements to assess the predictive capability of the model. Mean square errors of 4.49E-04 for superheater outlet pressure, 1.62E-03 for reheater inlet temperature, and 4.14E-04 for flue gas temperature at the air heater inlet were observed.

01 COAL, LIGNITE, AND PEAT↗

Experimental demonstration and performance evaluation of a complex fenestration system for daylighting and thermal harvesting

Two significant design strategies for mitigating building energy consumption are daylight redirection and solar energy harvesting. Effective daylighting implementation enhances the amount of useful natural light within a space and offsets the need for electric lighting. Solar energy harvesting systems can mitigate energy costs from mechanical systems by managing incoming thermal loads or capturing solar energy that can be used to supplement thermal systems in the building. While there are many available façade-based technologies that can perform daylighting or solar thermal energy harvesting, there remains a limitation in available systems that can perform both of them simultaneously. This paper, describes the design and experimental demonstration of a Liquid Filled Prismatic Louver (LFPL) system, which combines both energy-saving strategies. The LFPL system was installed in a south-facing room in New York City and evaluated for indoor daylight penetration and potential for thermal energy harvesting. Daylight redirection is achieved through the prismatic louver geometry and proper orientation, whereas thermal energy harvesting is achieved through IR absorption from the liquid (e.g., water) within the prisms. Daylighting performance was evaluated by illuminance measurements at key locations within the space, whereas thermal harvesting performance was evaluated through temperature measurements and thermal imaging analysis. We show that the LFPL system, with all prismatic elements oriented at the same angle, achieve a 2-fold and 8-fold enhancement in daylight redirection to the ceiling, for prism orientations of 10° and 20°, respectively. We also demonstrate the system’s capability to adjust to specific lighting needs, within the space, through the dynamic individual orientation of prismatic elements; thus, achieving a concentrated ceiling illuminance enhancement of ~100 times and ~200 times at 2.5 and 4.3 m away from the window sill, providing workplane illuminance enhancement of 6 and 2 times more than in the case of the control room with regular windows. Furthermore, we illustrate a reduction of potential heating loads at locations close to the window from the combination of infrared absorption in the water volume and the redirection of the incoming solar radiation, leading to a reduction of the workplane temperature by an average of 7–10 °C.

14 SOLAR ENERGY↗

Benchmarking Demand Flexibility in Commercial Buildings and Flattening the Duck – Addressing Baseline and Commissioning Challenges

With the transition from our traditional electric grid to a cleaner grid with renewable power generation, there is a need to enable building loads to be flexible. Load shedding and shifting will be essential for flattening the “Duck” for decarbonization. This paper explored the trend in the timing of DR events as a reflection of the grid’s needs using recent four years of event data from 203 retail stores in 11 states. The events are becoming significantly shorter with 2-hour duration being the most popular; shifting to late afternoon and early evening is another trend beyond California. Benchmarking will be essential for accounting DF as a reliable grid resource. This paper addresses a challenging aspect of benchmarking – inaccuracies in counterfactual baseline methods can introduce significant DF metrics variations in addition to weather and building characteristics related factors. The conventional “10/10” with adjustment baseline method has inherent limitation by design for load shifting applications. Therefore, it is imperative to identify alternative methods. This study compared three hourly regression baseline methods with “10/10” methods using two groups of commercial buildings that participated in DR programs: (1) 121 big-box retail stores, and (2) 11 office buildings in CA. The 14-day hourly outdoor temperature regression method was found to produce least error in the tested datasets and is promising for load shifting. The paper also pointed out that commissioning issues can also be a significant barrier for achieving consistent DF performance, which building managers and utilities should be aware of.

Liu, Jingjing↗

Preparing Distribution Utilities for the Future - Evolving Customer Consumption in Renewable Rich Grids: A Novel Analytical Framework

The research collaboration between NREL and BYPL focuses on the challenges caused by renewable integration into the power grid at large. Since the challenges and opportunities vary depending on the point of interconnection (distribution or transmission) the research team identified two tracks for research as listed below: 1. Power procurement - This research track focuses on the challenges and opportunities caused by GW scale renewable integration at the transmission level. Specifically, this track focuses on the contribution that utility-scale renewable energy procurement provides to distribution utilities, both from energy and capacity perspectives. In this track of research, utility customers are only considered as traditional (one-directional) consumers of energy. 2. Distributed energy resources - This research track focuses on the challenges and opportunities caused by many small-scale distributed renewable resource integrations at the distribution systems. At the power distribution level, distribution utilities may face not only new solar energy technologies, but also battery energy storage and electric vehicles as well. These three technologies (solar PV, battery energy storage, and electric vehicles) combined, pose unique challenges to distribution utilities. This track focuses on assessing the net-load evolution that distribution utilities observe as these emerging technologies make their way to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Status and Trends in the U.S. Voluntary Green Power Market (2021 Data)

Voluntary green power, for the purposes of this report, refers to renewable energy procurement by retail electricity customers above state renewable energy mandates. In this report, we present data and key trends for voluntary green power markets, except for a small portion of voluntary purchasing where no data are available. In 2021, about 8 million retail electricity customers procured about 244 million megawatt-hours (MWh) of voluntary green power (Figure ES-1), representing about 27% of all U.S. renewable energy sales, about 39% of non-hydro renewable energy sales, and about 6% of all U.S. retail electricity sales. Most of the remainder of U.S. renewable energy sales reflects renewable energy procured by load-serving entities to comply with state renewable energy mandates, also known as compliance-based procurement.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Connecting Risk and Resilience for a Power System Using the Portland Hills Fault Case Study

Active seismic faults in the Pacific Northwest area have encouraged electric utilities in the region to deeply contemplate and proactively intervene to support grid resilience. To further this effort this research introduces Monte Carlo (MC)-based power system modeling as a means to inform the Performance Based Earthquake Engineering method and simulates 100,000 sample earthquakes of a 6.8 magnitude (M6.8) Portland Hills Fault (PHF) scenario in the Portland General Electric (PGE) service territory as a proof of concept. This paper also proposes the resilience metric Seismic Load Recovery Factor (SLRF) to quantify the recovery of a downed power system and thus can be used to quantify earthquake economic risk. Using MC results, the SLRF was evaluated to be 19.7 h and the expected economic consequence cost of a M6.8 PHF event was found to be $\$180$ million with an annualized risk of $\$90,000$ given the event’s 1 in 2000 year probability of occurrence. The MC results also identified the eight most consequential substations in the PGE system—i.e., those that contributed to maximum load loss. This paper concludes that retrofitting these substations reduced the expected consequence cost of a M6.8 PHF event to $117 million.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Integration with High Performance Computing Systems for Microreactor Operation

Multiple nuclear microreactor concepts are currently being developed across several sizes and fuel types with high performance computing (HPC) systems anticipated to be end-users of the power. Nuclear microreactors are small in size, portable, produce less than 10 MW electric, operate autonomously, and have a refueling interval of as many as 10 years. However, their load-follow is also generally limited to 10%/minute or worse whereas the power variance in HPC systems easily exceeds this constraint under normal operations. This study explores an approach that requires no load-follow from the microreactor but integrates the HPC system with a microgrid built from commercial-off-the-shelf components. Three typical HPC architectures are explored in the context of microgrid operation in this study. Components of power quality and transient response are empirically measured for five different HPC load-follow response levels using a self-contained mobile datacenter connected to the microgrid capable of integration with a nuclear microreactor.

microgrids↗

Dry-pressed lithium nickel cobalt manganese oxide (NCM) cathodes enabled by holey graphene host

There is an increasing demand for electric vehicle batteries with higher energy densities that can be manufactured with low cost utilizing environmentally friendly processes. Lithium nickel cobalt manganese oxides (NCM), such as LiNi(0.5)Co(0.2)Mr(0.3)O(2) (NCM523), are commonly used in commercial lithium ion batteries for electric vehicle applications. These cathodes are typically fabricated using environmentally hazardous, energy intensive, and time-consuming solvent-based slurry casting processes. Polymeric binders, also required for cathode preparation, add weight and can undergo parasitic reactions during battery cycling. Here we report a facile, solvent-free, binder-free, and rapid cold-press electrode fabrication process to prepare high mass loading NCM cathodes within minutes. This process is enabled by the use of holey graphene, a unique lightweight, compressible carbon nanomaterial that serves as both a binder and an electrically conductive matrix. NCM cathodes fabricated by this method are stable and exhibit good active material utilization. A significant advantage for the dry-press process is that the electrode mass loadings can be readily increased simply by adding more composite powder to the compression molding die, resulting in improved areal capacities that are attractive for applications requiring high energy per unit footprint. (C) 2020 Elsevier Ltd. All rights reserved.

25 ENERGY STORAGE↗

Resilience of the Electric Grid Through Trustable IoT-Coordinated Assets

The electricity grid has evolved from a physical system to a cyberphysical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) including renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. We propose a framework in this paper for achieving grid resilience through suitably coordinated assets including a network of Internet of Things devices. A local electricity market is proposed to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. With this SA, we show that a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. Multiple demonstrations are carried out using a high-fidelity cosimulation platform, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

distributed energy resources↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Validated model of a thermoelectric heat pump clothes dryer using secondary pumped loops

The energy associated with clothes drying makes up 4% of the total residential electrical energy consumption in the US. The cost is high since most clothes dryers use electric resistance heating which is inexpensive but also energy inefficient. State-of-the-art vapor-compression heat pump clothes dryers offer significant energy savings but have limited market penetration in the US. Here, a new configuration of clothes dryer was studied that utilizes a solid-state thermoelectric heat pump with pumped secondary water loops and conventional fin-and-tube water-to-air heat exchangers. Experimental results are presented for the thermoelectric dryer prototype with a combined energy factor of 6.89 lb BDW /kWh (specific moisture extraction rate of 1.71 kg w /kWh) and a dry time of 84 min for a standard load size of 8.45 lb (3.83 kg) with 57.5% starting moisture content. This is a 85% energy efficiency improvement over baseline electric resistance dryers. The efficiency and drying time results achieved are similar to vapor compression heat pump dryers. Compared to previous air-based thermoelectric clothes dryers, the energy efficiency has been increased by 6%, but drying time has been reduced by as much as 47% using secondary pumped loops and separate heat exchangers, which represents a significant advancement in the technology. In addition to the experimental prototype, a model was also developed to study the performance. The model was validated against experimental prototype data and used to identify the range of performance (dry time and efficiency) that could be expected of the design.

42 ENGINEERING↗

Probabilistic impact of electricity tariffs on distribution grids considering adoption of solar and storage technologies

This study models the role of electricity tariffs on the long-term adoption of photovoltaic and storage technologies as well as the consequent impact on the distribution grid. An adoption model that captures the economic rationality of tariff-driven investments and considers the stochastic nature of individual consumers’ decisions is proposed. This model is then combined with a probabilistic load flow to evaluate the long-term impacts of the adoption on the voltage profiles of the distribution grid. To illustrate the methodology, different components of the electricity tariffs, including solar compensation mechanisms and time differentiation of Time-of-Use (ToU) rates, are evaluated, using a case study involving a section of a medium-voltage network with 118 nodes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution Operations: The Evolution of Distributed Energy Resources [Guest Editorial]

Utilities around the world are experiencing change with the increasing digitalization of their systems and those of their customers. Efforts to decarbonize the electric power system have led to growth in renewable energy resources, particularly distributed energy resources (DERs), such as generation, storage, and flexible load, both in front of and behind the meter. As this change occurs in any given utility service area, new tools, such as advanced distribution management systems (ADMSs), are needed to manage utility operations, planning, and business issues, some of which are discussed here.

distributed energy resources, DER, decarbonize, re↗