Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric currents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Experimental design for the evaluation of high-T(sub c) superconductive thermal bridges in a sensor satellite

Infrared sensor satellites, which consist of cryogenic infrared sensor detectors, electrical instrumentation, and data acquisition systems, are used to monitor the conditions of the earth's upper atmosphere in order to evaluate its present and future changes. Currently, the electrical connections (instrumentation), which act as thermal bridges between the cryogenic infrared sensor and the significantly warmer data acquisition unit of the sensor satellite system, constitute a significant portion of the heat load on the cryogen. As a part of extending the mission life of the sensor satellite system, the researchers at the National Aeronautics and Space Administration's Langley Research Center (NASA-LaRC) are evaluating the effectiveness of replacing the currently used manganin wires with high-temperature superconductive (HTS) materials as the electrical connections (thermal bridges). In conjunction with the study being conducted at NASA-LaRC, the proposed research is to design a space experiment to determine the thermal savings on a cryogenic subsystem when manganin leads are replaced by HTS leads printed onto a substrate with a low thermal conductivity, and to determine the thermal conductivities of HTS materials. The experiment is designed to compare manganin wires with two different types of superconductors on substrates by determining the heat loss by the thermal bridges and providing temperature measurements for the estimation of thermal conductivity. A conductive mathematical model has been developed and used as a key tool in the design process and subsequent analysis.

Scott, Elaine P.↗

Electric field observations by incoherent scatter radar in the auroral zone.

Analysis of ion drift velocity measurements, made for a 24-hour period in February 1972 by the incoherent scatter radar at Chatanika, Alaska (L = 5.7), provides a detailed view of electric fields and currents in the auroral zone. Large northward electric fields were seen in the evening sector, and an abrupt change to southward occurred at the start of a midnight sector substorm. The westward electric field was generally much smaller than the north-south electric field but showed a rapid increase at the time of a westward auroral surge. Study of global magnetograms and all-sky camera photographs has led to the identification of five substorms during the 24-hour observation period. These substorms were sufficiently separated in time to allow identification of the electric field and current variations in late afternoon, evening, and morning local time sectors.

Banks, P. M.↗

The effect of solar array degradation on electric propulsion spacecraft performance.

Current estimates of solar-electric-propulsion spacecraft performance are based upon a solar-array output power which is degraded by approximately 10-13% to account for possible losses caused by proton, electron and micrometeorite damage. Past studies have used a worst case analysis in which the maximum degradation was taken to occur at the beginning of the mission. This paper presents a comparison of mission studies using a hypothetical exponential decrease in power with time, with those using a sudden degradation of solar power. These comparisons indicate that the performance gain by using a time varying degradation during the mission is quite small for outbound missions in the solar system. In addition an indication of the power allocation strategy to be followed during a mission is presented.

Sauer, C. G., Jr.↗

Understanding the Capabilities and Limitations of the Controls and Operations of High Voltage Direct Current (HVdc) Converters in Interconnected Electric Power Systems

This project will seek to build a fundamental understanding, and capability, to model and simulate the controls and operations of high voltage direct current (HVdc) converter stations in an electromagnetic simulation environment. While HVdc stations have been operated in the United States for over 50 years, these are typically simple two terminal point-to-point systems. Recently multi-terminal systems have begun to be deployed. The challenge with these new multi-terminal systems is that they often use different control schemes on the different terminals. The interactions of existing and new controls, and the fact that HVdc systems are rates in the 1,000’s of MWs means that small control instabilities can have dramatic impacts to bulk power systems. Despite these challenges, the operational capabilities of HVdc make them an attractive option for the transfer of the large amounts of renewable electricity that will be necessary for decarbonization of the nation’s electrical infrastructure and other sectors.

42 ENGINEERING↗

Projecting Future Energy Production from Operating Wind Farms in North America. Part II: Statistical Downscaling

Abstract Capacity factors (CFs) derived from daily expected power at 22 operating wind farms in different regions of North America are used as predictands to train statistical downscaling algorithms using output from ERA5. The statistical downscaling models are then used to make CF projections for a suite of CMIP6 Earth System Models (ESMs). Downscaling is performed using a hybrid statistical approach that employs synoptic types derived using k -means clustering applied to sea level pressure fields with variance corrections applied as a function of the pressure gradient intensity. ESMs exhibit marked variability in terms of the skill with which the frequency of synoptic types and pressure gradients are reproduced relative to ERA5, and that differential skill is used to infer differential credibility in the associated CF projections. Projections of median annual mean CF [P50(CF)] in each 20-yr period from 1980 to 2099 show evidence of declines at most wind farms except in parts of the southern Great Plains, although the magnitude of the changes is strongly dependent on the ESM. For example, P50(CF) in 2080–99 deviate from those in 1980–99 by from −3.1 to +0.2 percentage points in the Northeast. The largest-magnitude declines in P50(CF) ranging from −3.9 to −2 percentage points are projected for the southern West Coast. CF trends exhibit marked seasonality and are strongly linked to changes in the relative intensity of future synoptic patterns, with much less impact from shifts in the occurrence of synoptic types over time. Internal climate modes continue to play a significant role in inducing interannual variability in wind power production, even under high radiative forcing scenarios. Significance Statement We describe how future climate changes may affect wind resources and wind power generation. Near-term changes in projected wind power electricity generation potential at operating wind farms over North America are small, but by the end of the current century electricity production is projected to decrease in many areas but may increase in parts of the southern Great Plains. The amount of change in projected wind power production is a strong function of the Earth system model that is downscaled and also depends on the continued presence of internally forced climate variability. An additional dependence on the amount of greenhouse gas–induced global warming indicates the transition of the energy sector to low-carbon sources may assist in maintaining the abundant U.S. wind resource.

Meteorology & Atmospheric Sciences↗

Nanosecond Structural Dynamics during Electrical Melting of Charge Density Waves in 1⁢T-TaS 2

Electrical control of charge density waves has been of immense interest, as the strong underlying electron-lattice interactions potentially open new, efficient pathways for manipulating their ordering and, consequently, their electronic properties. However, the transition mechanisms are often unclear as electric field, current, carrier injection, heat, and strain can all contribute and play varying roles across length scales and timescales. Here, we provide insight on how electrical stimulation melts the room temperature charge density wave order in 1T-TaS 2 by visualizing the atomic and mesoscopic structural dynamics from quasistatic to nanosecond pulsed melting. Using a newly developed ultrafast electron microscope setup with electrical stimulation, we reveal the order and strain dynamics during voltage pulses as short as 20 ns. The order parameter dynamics across a range of pulse amplitudes and durations support a thermally driven mechanism even for fields as high as 19 kV cm -1 . In addition, time-resolved imaging reveals a heterogeneous, mesoscopic strain response across the flake, including MHz-scale acoustic resonances that emerge during sufficiently short pulsed excitation which may modulate the order. In conclusion, these results suggest that metallic charge density wave phases like studied here may be more robust to electronic switching pathways than insulating ones, motivating further investigations at higher fields and currents in this and other related systems.

36 MATERIALS SCIENCE↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗

Electron-radiation effects on the ac and dc electrical properties and unpaired electron densities of three aerospace polymers

The effects of gigarad-level total absorbed doses from 1-MeV electrons on the post-irradiation alternating-current (ac) and direct-current (dc) electrical properties and the unpaired electron densities have been studied for Kapton, Ultem, and Mylar. The unpaired electron densities (determined from electron paramagnetic resonance spectroscopy) and the dc electrical conductivities of the irradiated materials were monitored as functions of time following the exposures to determine their decay characteristics at room temperature. The elevated-temperature ac electrical dissipations of the Ultem and Mylar were affected by the radiation. The dc conductivity of the Kapton increased by five orders of magnitude, while the dc conductivities of the Ultem and Mylar increased by less than an order of magnitude, due to the radiation. The observed radiation-generated changes in the ac electrical dissipations are explained in terms of known radiation-generated changes in the molecular structures of the three materials. A preliminary model relating the dc electrical conductivity and the unpaired electron density in the Kapton is proposed.

Long, Sheila Ann T.↗

Effect of Initial Velocity on One-Dimensional, Ambipolar, Space-Charge Currents

Oppositely directed flows of positive and negative charges constitute an ambipolar current. A general case is analyzed in which the charges traverse the evacuated space between plane-parallel boundaries and all particles of a given charge species are monoenergetic. It is assumed that the charges may possess non-vanishing initial kinetic energy. This represents an extension of analyses by Langmuir and Muller-Lubeck for vanishing initial kinetic energy. Sample calculations of dimensionless current densities, electric and potential fields, and charge-density distributions are exhibited for cases where the electric field is assumed to vanish at one boundary but the species initial velocities may not. It is shown that resulting ion currents may be several times the Child's law limit if initial kinetic energies are of the order of the potential energy.

SPACE CHARGE↗

Fault Detection and Diagnosis in Spacecraft Electrical Power Systems

The ability to accurately identify and isolate failures in the electrical power system (EPS) is critical to ensure the reliability of spacecraft. This paper proposes a novel solution to the problem of fault detection and diagnosis in direct current (DC) electric power systems for spacecraft. Autonomous operation becomes essential during deep space missions that lack the ability to monitor and control the spacecraft from ground locations. The current state of EPS fault supervision is insufficient to guarantee highly reliable operation. To solve this issue, a combination of model-based and knowledge-based techniques are used in a hierarchical framework to improve the diagnostic performance of the system. Noise, disturbances, and modeling errors are considered in the design of the fault detection system. Practical considerations related to spacecraft flight hardware and software are accounted for in the system design for flight applications. To assess the functionality of the design, a wide array of failures are simulated in a series of experiments. The experiments showed that the technique improved the capability of the autonomous system by increasing the number of fault types diagnosed. The significance of this study is to provide a framework capable of advanced diagnostics of an EPS with little to no interaction from human operators.

Autonomous Power Systems↗

A universal steady state I-V relationship for membrane current

A purely electrical mechanism for the gating of membrane ionic channel gives rise to a simple I-V relationship for membrane current. Our approach is based on the known presence of gating charge, which is an established property of the membrane channel gating. The gating charge is systematically treated as a polarization of the channel protein which varies with the external electric field and modifies the effective potential through which the ions migrate in the channel. Two polarization effects have been considered: 1) the up or down shift of the whole potential function, and 2) the change in the effective electric field inside the channel which is due to familiar effect of the effective reduction of the electric field inside a dielectric body because of the presence of surface charges on its surface. Both effects are linear in the channel polarization. The ionic current is described by a steady state solution of the Nernst-Planck equation with the potential directly controlled by the gating charge system. The solution describes reasonably well the steady state and peak-current I-V relationships for different channels, and when applied adiabatically, explains the time lag between the gating charge current and the rise of the ionic current. The approach developed can be useful as an effective way to model the ionic currents in axons, cardiac cells and other excitable tissues.

NASA Discipline Regulatory Physiology↗