Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnosability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

The importance of cycle-by-cycle data in performing rapid battery technology development and validation

Lithium-ion battery (LiB) technology is playing a crucial role in transforming the predominantly fossil fuel-based transportation and stationary storage sectors to achieve a low-carbon economy. Rapid innovation in the LiB materials to electrode to cell design is happening to satisfy the performance, life, and safety metrics required by those myriads of applications. Lately, advanced analytics, such as machine-learning or artificial intelligence (ML/AI) techniques, are being used more frequently to aid in expedited LiB technology development, performance validation, and life prediction. The success of these techniques often relies on a large volume of well-defined and high-quality battery test data. On the other hand, most battery developers and research and development (R&D) communities are still following a classical approach to develop batteries, which is running calendar- and/or cycle-aging tests, performing reference performance tests (RPTs), and conducting post-mortem analyses periodically without paying attention to the wealth of data often not collected during the calendar or cycle life aging tests. This sparse data collection approach is time- and resource-intensive, requiring data capture and evaluation of months to years of RPT data to diagnose accurate battery state of performance, health, and safety. Even so, the underlying aging modes and mechanisms can be missed. If collected properly, battery test data during cycling or calendaring can be efficiently combined with ML/AI techniques to create powerful tools in the rapid diagnosis of battery state of performance, health, and safety along with insights into underlying aging modes and mechanisms. In this report, we discuss the importance of effective cycle-by-cycle (CBC) data collection with example case studies. Within a reasonable timeframe, RPT data are often inadequate in capturing many of the crucial battery aging dynamics, which often predominantly show up in CBC test data. Finally, we also show examples of ML/AI techniques that use CBC data in rapid diagnosis and projection of LiB state of health (SOH) to motivate the scientific community in collecting and using CBC data to facilitate expeditious technology development and validation.

25 ENERGY STORAGE↗

PINN surrogate of Li-ion battery models for parameter inference, Part I: Implementation and multi-fidelity hierarchies for the single-particle model

To plan and optimize energy storage demands that account for Li-ion battery aging dynamics, techniques need to be developed to diagnose battery internal states accurately and rapidly. Here, this study seeks to reduce the computational resources needed to determine a battery's internal states by replacing physics-based Li-ion battery models - such as the single-particle model (SPM) and the pseudo-2D (P2D) model - with a physics-informed neural network (PINN) surrogate. The surrogate model makes high-throughput techniques, such as Bayesian calibration, tractable to determine battery internal parameters from voltage responses. This manuscript is the first of a two-part series that introduces PINN surrogates of Li-ion battery models for parameter inference (i.e., state-of-health diagnostics). In this first part, a method is presented for constructing a PINN surrogate of the SPM. A multi-fidelity hierarchical training, where several neural nets are trained with multiple physics-loss fidelities is shown to significantly improve the surrogate accuracy when only training on the governing equation residuals. The implementation is made available in a companion repository (https://github.com/NREL/PINNSTRIPES). The techniques used to develop a PINN surrogate of the SPM are extended in Part II for the PINN surrogate for the P2D battery model, and explore the Bayesian calibration capabilities of both surrogates.

25 ENERGY STORAGE↗

Neural Posterior Estimation for Scalable and Accurate Inverse Parameter Inference in Li-Ion Batteries

Diagnosing the internal state of Li-ion batteries is critical for battery research, operation of real-world systems, and prognostic evaluation of remaining lifetime. By using physics-based models to perform probabilistic parameter estimation via Bayesian calibration, diagnostics can account for the uncertainty due to model fitness, data noise, and the observability of any given parameter. However, Bayesian calibration in Li-ion batteries using electrochemical data is computationally intensive even when using a fast surrogate in place of physics-based models, requiring many thousands of model evaluations. A fully amortized alternative is neural posterior estimation (NPE). NPE shifts the computational burden from the parameter estimation step to data generation and model training, reducing the parameter estimation time from minutes to milliseconds, enabling real-time applications. The present work shows that NPE can infer parameters equally or more accurately than Bayesian calibration, even if it leads to higher voltage reconstruction errors. We also demonstrate that the higher computational costs for data generation are tractable even in high-dimensional cases (ranging from 6 to 27 estimated parameters). The NPE method also offers several interpretability advantages over Bayesian calibration, such as local parameter sensitivity to specific regions of the voltage curve. The NPE method is demonstrated using an experimental fast charge dataset, with parameter estimates validated against measurements of loss of lithium inventory and loss of active material. The implementation is made available in a companion repository (https://github.com/NatLabRockies/BatFIT).

25 ENERGY STORAGE↗

In-cylinder flows of a motored four-stroke engine with flat-crown and slightly concave-crown pistons

The temporal and spatial evolution processes of the in-cylinder flow structures and turbulence intensities in the symmetry and offset planes of a motored four-valve, four-stroke engine during the intake and compression strokes are diagnosed by using a particle image velocimeter. Two pistons of different crown shapes (flat-crown and slightly concave-crown pistons) are studied. The inception, establishment, and evolution of the tumbling vortical flow structures during the intake and compression strokes are clearly depicted. Quantitative strengths of the rotating vortical flow motions are presented by a dimensionless parameter, the tumble ratio, which can represent the mean angular velocity of the vortices in the target plane. The turbulence intensity of the in-cylinder flow is also calculated by using the measured time-varying velocity data. The results show that the flat-crown piston induces higher bulk-averaged tumble ratio and turbulence intensity than the slightly concave-crown piston does because the tumble ratio and turbulence generated by the flat-crown piston in the offset planes during the compression stroke are particularly large. The engine with the flat-crown piston also presents larger torque and power outputs and lower hydrocarbon emission than that with the slightly concave-crown piston. This might be caused by the enhanced combustion in the engine cylinder due to the stronger tumble ratio and turbulence intensity. (author)

33 ADVANCED PROPULSION SYSTEMS↗

CAKE: Consistent Automatic Kinetic Equilibrium reconstruction

Magnetohydrodynamic equilibrium reconstructions with kinetic constraints are an essential input of many tokamak stability and transport analysis work- flows. The reconstructions themselves also contain useful information about pressure and current density distributions within the plasma which can be used to drive other calculations. While standardized magnetic-only, and partially kinetic equilibrium reconstruction is widely available and used, re- constructions for well diagnosed machines such as DIII-D, that incorporates a large and heterogeneous set of internal diagnostic measurements yet robustly reaching high numerical accuracy have been a time intensive, manual process. The Consistent Automatic Kinetic Equilibrium reconstruction tool (CAKE) has been developed and implemented at DIII-D for producing low error, kinetically constrained reconstructions without human intervention, and to identify strategies for doing so that would be broadly applicable. Here, the techniques employed to allow CAKE to handle data of limited quality and availability, as well as the full automation of the workflow may assist future efforts to form kinetic constraint profiles in real time plasma control applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Catalytic generation of methane at 60–100 °C and 0.1–300 MPa from source rocks containing kerogen Types I, II, and III

Low temperature (60 and 100 °C) and long-term (6 months to 5 years) heating of pre-evacuated and sterilized shales and coals containing kerogen Types I (Mahogany Shale), II (Mowry Shale and New Albany Shale), and III (Springfield Coal and Wilcox Lignite) with low initial maturities (vitrinite reflectance Ro 0.39–0.62%) demonstrates that catalytically generated hydrocarbons may explain the occurrence of some non-biogenic natural gas accumulations where insufficient thermal maturity contradicts the conventional thermal cracking paradigm. Extrapolation of the observed rate of catalytic methanogenesis in the laboratory suggests that significant amounts of sedimentary organic carbon can be converted to relatively dry natural gas over tens of thousands of years in sedimentary basins at temperatures as low as 60 °C. Here, our laboratory experiments utilized source rock (shale and coal) chips sealed in gold and Pyrex® glass tubes in the presence of hydrogen-isotopically contrasting waters. Parallel heating experiments applied hydrostatic pressures from 0.1 to 300 MPa. Control experiments constrained the influence of pre-existing and residual methane in closed pores of rock chips that was unrelated to newly generated methane. This study’s experimental methane yields at 60 and 100 °C are 5–11 orders of magnitude higher than the theoretically predicted yields from kinetic models of thermogenic methane generation, which strongly suggests a contribution of catalytic methanogenesis. Higher temperature, longer heating time, and lower hydrostatic pressure enhanced catalytic methanogenesis. No clear relationships were observed between kerogen type or total organic carbon content and methane yields via catalysis. Catalytic methanogenesis was strongest in Mowry Shale where methane yields at 60 °C amounted to ~2.5 μmol per gram of organic carbon after one year of hydrous heating at ambient pressure. In stark contrast to the earlier findings of hydrogen isotopic exchange between water and thermogenic methane in hydrous pyrolysis experiments above 300 °C, the hydrogen isotopic composition of added water exerted limited influence on the δ2H value of methane generated catalytically at low temperatures. We hypothesize that the catalytic sites responsible for methanogenesis are located in hydrophobic microenvironments with limited access to water. The δ13CCH4 values of methane generated catalytically at 60–100 °C range from ~–57.6 to –41.4‰ and are thus similar to typical thermogenic methane (δ13CCH4 >–50‰) and microbially generated methane (<–55‰). Future studies need to evaluate the possibility that clumped isotope characteristics of catalytically generated methane can diagnose the low-temperature regime of catalytic methanogenesis. Furthermore, testing of freshly cored anoxic rocks is needed to determine whether the use of archived, oxygen-exposed rocks in geochemical maturation/catalysis studies introduces artifacts in experimental hydrocarbon yields.

58 GEOSCIENCES↗

Self-consistent measurement of the equation of state of liquid deuterium

We combine experiments and theoretical models to characterize warm dense deuterium. A shockwave was driven in a planar target by the OMEGA laser without a standard pusher making the analysis independent of a quartz or aluminium pressure standard. The conditions of the shocked material were diagnosed with VISAR and optical pyrometry which yields the shock velocity (16.9+/- 0.9 km/s) and the temperature (0.57+/- 0.05 eV). We find a self-consistent description of the data when using ab initio simulations (DFT-MD), but not for other equation of state (EOS) models tested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detailed characterization of laser-produced astrophysically-relevant jets formed via a poloidal magnetic nozzle

We report that the collimation of astrophysically-relevant plasma ejecta in the form of narrow jets via a poloidal magnetic field is studied experimentally by irradiating a target situated in a 20 T axial magnetic field with a 40 J, 0.6 ns, 0.7 mm diameter, high-power laser. The dynamics of the plasma shaping by the magnetic field are studied over 70 ns and up to 20 mm from the source by diagnosing the electron density, temperature and optical self-emission. These show that the initial expansion of the plasma is highly magnetized, which leads to the formation of a cavity structure when the kinetic plasma pressure compresses the magnetic field, resulting in an oblique shock [A. Ciardi et al., Phys. Rev. Lett. 110, 025002 (2013)]. The resulting poloidal magnetic nozzle collimates the plasma into a narrow jet [B. Albertazzi et al., Science 346, 325 (2014)]. At distances far from the target, the jet is only marginally magnetized and maintains a high aspect ratio due to its high Mach-number (M~20) and not due to external magnetic pressure. The formation of the jet is evaluated over a range of laser intensities (10 12 –10 13 W/cm 2 ), target materials and orientations of the magnetic field. Lastly, plasma cavity formation is observed in all cases and the viability of long-range jet formation is found to be dependent on the orientation of the magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modelling K shell spectra from short pulse heated buried microdot targets

K shell X-ray emission measurements have been used to diagnose plasma conditions in short-pulse heated buried microdot targets on the Orion high power laser. These experiments have been used to validate simulations of short pulse laser-solid interaction that combine hybrid PIC modelling of the laser absorption with radiation-hydrodynamics simulations including an electron transport model. Comparison of these simulations with streaked K shell spectroscopy show the importance of including radial gradients in fitting the spectra. An example is presented of the emission of sulphur from a 50 µm diameter microdot sample buried in a plastic foil. Previously agreement between simulation and experiment was obtained only by treating the absorbed energy, electron temperature and beam divergence as fitting parameters. Overall, the good agreement obtained in this work used the measured laser energy and laser pulse length and calculated the laser-solid target interaction from first principles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review of the 10 th Non-LTE Code Comparison Workshop

This work reports on the results of the 10 th Non-LTE code comparison workshop, which was held at the University of San Diego campus November 28 through December 1, 2017. Non-equilibrium collisional-radiative models predict the electronic state populations and attendant emission and absorption characteristics of hot, dense matter and are used to help design and diagnose high-energy-density experiments. At this workshop, fifteen codes from eleven institutions contributed results for steady-state and time-dependent neon, aluminum, silicon, and chlorine cases relevant to a variety of high-density experimental and radiation-driven astrophysical systems. We focus on differences in the predictions from codes with different internal structure, completeness, density effects, and rate fidelity and the impact of those differences on hot, dense plasma diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Establishing an isoelectronic line ratio temperature diagnostic for soft X-ray absorption spectroscopy

For diagnosing temperatures of high-energy-density plasmas, relying on the ratio of a pair of isoelectronic spectral lines provides the alternative of ‘‘matched charge-state transits in different elements’’ to the more conventional, ‘‘unmatched charge-state transits in the same-element’’ spectral-line-ratio technique. In contrast to a novel previous establishment of isoelectronic emission-line ratio determination of plasma temperature, this report determines plasma temperature from the ratio of isoelectronic absorption spectral line pairs. Here, the feasibility of this technique is assessed from experimentally acquired transmission spectra, spanning the 7– 15 Å range, through a 0.4 μm MgO-NaF foil, tamped with CH, x-ray-radiation heated by a z-pinch dynamic hohlraum (ZPDH), and backlit by the brief X-ray burst upon imploding-wire stagnation on the Z pulsed-power facility at Sandia National Laboratories. As expected from the slight difference between interstage and isoelectronic absorption processes, a quantitative comparison between the value of isoelectronic-absorption-derived temperature and the value of inter-stage-absorption-derived temperature is shown to yield a well correlated, slight difference in inferred values of plasma temperature associated with local thermodynamic equilibrium.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and evaluation of virtual refrigerant mass flow sensors for fault detection and diagnostics

Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor map that relates refrigerant flow rate to measurements of inlet and outlet pressure, and inlet temperature measurements. The second model uses an energy-balance method on the compressor that uses a compressor map for power consumption, which is relatively independent of compressor faults that influence mass flow rate. The third model is developed using an empirical correlation for an electronic expansion valve (EEV) based on an orifice equation. The three VRMFs are shown to work well in estimating refrigerant mass flow rate for various systems under fault-free conditions with less than 5% RMS error. Each of the three mass flow rate estimates can be utilized to diagnose and track the following faults: 1) loss of compressor performance, 2) fouled condenser or evaporator filter, 3) faulty expansion device, respectively. For example, a compressor refrigerant flow map model only provides an accurate estimation when the compressor operates normally. When a compressor is not delivering the expected flow due to a leaky suction or discharge valve or other internal fault, the energy-balance or EEV model can provide accurate flow estimates. In this paper, the flow differences provide an indication of loss of compressor performance and can be used for fault detection and diagnostics.

Kim, Woohyun↗

Multi-Institution Prospective Trial of Reduced-Dose Craniospinal Irradiation (23.4 Gy) Followed by Conformal Posterior Fossa (36 Gy) and Primary Site Irradiation (55.8 Gy) and Dose-Intensive Chemotherapy for Average-Risk Medulloblastoma

Purpose: Limiting the neurocognitive sequelae of radiotherapy (RT) has been an objective in the treatment of medulloblastoma. Conformal RT to less than the entire posterior fossa (PF) after craniospinal irradiation might reduce neurocognitive sequelae and requires evaluation. Methods and Materials: Between October 1996 and August 2003, 86 patients, 3-21 years of age, with newly diagnosed, average-risk medulloblastoma were treated in a prospective, institutional review board-approved, multi-institution trial of risk-adapted RT and dose-intensive chemotherapy. RT began within 28 days of definitive surgery and consisted of craniospinal irradiation (23.4 Gy), conformal PF RT (36.0 Gy), and primary site RT (55.8 Gy). The planning target volume for the primary site included the postoperative tumor bed surrounded by an anatomically confined margin of 2 cm that was then expanded with a geometric margin of 0.3-0.5 cm. Chemotherapy was initiated 6 weeks after RT and included four cycles of high-dose cyclophosphamide, cisplatin, and vincristine. Results: At a median follow-up of 61.2 months (range, 5.2-115.0 months), the estimated 5-year event-free survival and cumulative incidence of PF failure rate was 83.0% {+-} 5.3% and 4.9% {+-} 2.4% ({+-} standard error), respectively. The targeting guidelines used in this study resulted in a mean reduction of 13% in the volume of the PF receiving doses >55 Gy compared with conventionally planned RT. The reductions in the dose to the temporal lobes, cochleae, and hypothalamus were statistically significant. Conclusion: This prospective trial has demonstrated that irradiation of less than the entire PF after 23.4 Gy craniospinal irradiation for average-risk medulloblastoma results in disease control comparable to that after treatment of the entire PF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adjuvant Therapy for Resected Gastric Cancer-Rapid, Yet Incomplete Adoption Following Results of Intergroup 0116 Trial

Purpose: The Southwest Oncology Group/Intergroup 0116 (INT-0116) trial showed that adjuvant chemoradiotherapy improves survival in high-risk gastric adenocarcinoma patients. This study examined the adoption of adjuvant treatment following the trial results and the factors associated with its use. Methods and Materials: Between 1996 and 2003, patients aged 18-85 years with resected gastric adenocarcinoma were identified in the Surveillance, Epidemiology, and End Results (SEER) database and classified as diagnosed before (January 1996 to April 2000) or after (May 2000 to December 2003) presentation of the INT-0116 trial findings. Univariate and multivariable models were used to determine the factors associated with use of adjuvant radiotherapy (RT). Results: Of 10,230 patients studied, 14.6% were given adjuvant RT before the INT-0116 trial, increasing to 30.4% afterward (p < 0.001). Significant increases in adjuvant RT from before to after INT-0116 were seen in all demographic categories. Younger patients were significantly more likely to receive adjuvant RT (44.5%, 18-59 years; 31.0%, 60-74 years; and 12.6%, 75-85 years, p < 0.0001). Married patients were significantly more likely to receive adjuvant RT (30.9%) than were unmarried patients (23.6%, p < 0.001). A greater depth of tumor invasion, worse nodal status, and more lymph nodes assessed were associated with adjuvant RT (p < 0.0001). The rate of adjuvant RT varied from 22.9-44.2% across SEER regions. On multiple logistic regression analysis, age, SEER region, marital status, assessed lymph nodes, tumor depth, and nodal status were all significant independent predictors of the use of adjuvant RT. Conclusion: Use of adjuvant RT doubled after the INT-0116 trial results became public; however, the fraction of patients receiving adjuvant RT is still low. Additional examination of the statistically significant and clinically relevant variability between different SEER regions, tumor characteristics, and patient demographics is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Possible Misinterpretation of Demarcated Solid Patterns of Radiation Fibrosis on CT Scans as Tumor Recurrence in Patients Receiving Hypofractionated Stereotactic Radiotherapy for Lung Cancer

Purpose: To retrospectively analyze opacity changes near primary lung cancer tumors irradiated by using hypofractionated stereotactic radiotherapy (HSRT) to determine the presence or absence of tumor recurrence. Methods and Materials: After review-board approval for a retrospective study, we examined data from 50 patients treated with curative intent for proven or highly suspected localized peripheral-lung cancer and followed up for at least 12 months. All patients had received 50 Gy in five fractions (80% isodose) and were followed up monthly with chest X-ray until clinical and X-ray findings stabilized. Follow-up computed tomography scans were performed 1 and 3 months after HSRT and thereafter at 3-month intervals during the first 2 years. Results: Median follow-up was 30.4 months (range, 12.0-73.8 months). Abnormal opacities that were suspicious for recurrent tumor appeared in 20 patients at a median of 20.7 months (range, 5.9-61.4 months). Only 3 patients were finally found to have recurrence; 14 were recurrence free but were suspected to have fibrosis, and findings for the other 3 patients were considered equivocal because of a short follow-up period ({<=}6 months). Conclusion: Radiation fibrosis, which may occur 1 year or longer after completion of HSRT, is difficult to distinguish from tumor recurrence. Even when opacities increase on follow-up radiologic scans, recurrence cannot be diagnosed conclusively based on image findings; biopsy occasionally is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pelvic Insufficiency Fracture After Pelvic Radiotherapy for Cervical Cancer: Analysis of Risk Factors

Purpose: To investigate the incidence, clinical characteristics, and risk factors of pelvic insufficiency fracture (PIF) after pelvic radiotherapy (RT) in cervical cancer. Methods and Materials: Medical records and imaging studies, including bone scintigraphy, CT, and MRI of 557 patients with cervical cancer who received whole-pelvic RT between January 1998 and August 2005 were reviewed. Results: Eighty-three patients were diagnosed as having PIF after pelvic RT. The 5-year cumulative incidence of PIF was 19.7%. The most commonly involved site was the sacroiliac joint. Pelvic pain developed in 48 patients (57.8%) at diagnosis. Eleven patients (13.3%) needed admission or narcotics because of severe pain, and others had good relief of symptoms with conservative management. In univariate analysis, age {>=}55 years (p < 0.001), anteroposterior/posteroanterior parallel opposing technique (p = 0.001), curative treatment (p < 0.001), and radiation dose {>=}50.4 Gy (p = 0.005) were the predisposing factors for development of PIF. Concurrent chemotherapy (p = 0.78) was not significant. Multivariate analysis showed that age {>=}55 years (p < 0.001), body weight <55 kg (p = 0.02), curative treatment (p = 0.03), and radiation dose {>=}50.4 Gy (p = 0.04) were significant predisposing factors for development of PIF. Conclusion: The development of PIF is not rare after pelvic RT. The use of multibeam arrangements to reduce the volume and dose of irradiated pelvic bone can be helpful to minimize the risk of fracture, especially in elderly women with low body weight.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Outcome of Combined Modalities for Buccal Cancers: Unilateral or Bilateral Neck Radiation?

Purpose: To evaluate the outcome of treatment for buccal cancers and assess the impact of unilateral vs. bilateral adjuvant neck radiation. Methods and Materials: We retrospectively reviewed the course of 145 patients newly diagnosed with buccal squamous cell carcinoma without distant metastases who completed definitive treatment between January 1994 and December 2000. Of 145 patients, 112 (77%) had Stage III or IV disease. All underwent radical surgery with postoperative radiotherapy (median dose, 64 Gy), including unilateral neck treatment in most (n = 120, 82.8%). After 1997, cisplatin-based concomitant chemoradiotherapy was given for high-risk patients with more than two involved lymph nodes, extracapsular spread, and/or positive margins. Results: The 5-year disease-specific survival rate for Stages I-IV was 87%, 83%, 61%, and 60%, respectively (p = 0.01). The most significant prognostic factor was N stage, with the 5-year disease-specific survival rate for N0, N1, and N2 being 79%, 65%, and 54%, respectively (p 0.001). For patients with more than two lymph nodes or positive extracapsular spread, cisplatin-based concomitant chemoradiotherapy improved locoregional control (p = 0.02). Locoregional control did not differ between patients undergoing unilateral or bilateral neck treatments (p = 0.95). Contralateral neck failure occurred in only 2.1%. Conclusions: In patients with buccal carcinoma after radical resection, ipsilateral neck radiation is adequate. Bilateral prophylactic neck treatment does not confer an added benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FDG-PET/CT Imaging for Staging and Target Volume Delineation in Preoperative Conformal Radiotherapy of Rectal Cancer

Purpose: To investigate the potential impact of using {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) on staging and target volume delineation for patients affected by rectal cancer and candidates for preoperative conformal radiotherapy. Methods and Materials: Twenty-five patients diagnosed with rectal cancer T3-4 N0-1 M0-1 and candidates for preoperative radiotherapy underwent PET/CT simulation after injection of 5.18 MBq/kg of FDG. Clinical stage was reassessed on the basis of FDG-PET/CT findings. The gross tumor volume (GTV) and the clinical target volume (CTV) were delineated first on CT and then on PET/CT images. The PET/CT-GTV and PET/CT-CTV were analyzed and compared with CT-GTV and CT-CTV, respectively. Results: In 4 of 25 cases (24%), PET/CT affected tumor staging or the treatment purpose. In 3 of 25 cases (12%) staged N0 M0, PET/CT showed FDG uptake in regional lymph nodes and in a case also in the liver. In a patient with a single liver metastasis PET/CT detected multiple lesions, changing the treatment intent from curative to palliative. The PET/CT-GTV and PET/CT-CTV were significantly greater than the CT-GTV (p = 0.00013) and CT-CTV (p = 0.00002), respectively. The mean difference between PET/CT-GTV and CT-GTV was 25.4% and between PET/CT-CTV and CT-CTV was 4.1%. Conclusions: Imaging with PET/CT for preoperative radiotherapy of rectal cancer may lead to a change in staging and target volume delineation. Stage variation was observed in 12% of cases and a change of treatment intent in 4%. The GTV and CTV changed significantly, with a mean increase in size of 25% and 4%, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗