Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Synthesis and evaluation of polymers for use in early warning fire alarm devices

Conjugated polyacetylene polymers and one condensation polyene, all containing a high degree of conjugated unsaturation, were synthesized. These polymers were characterized by chemical analysis and by thermogravimetric analysis, as well as for their film-forming capability and gas/polymer interactions. It was found that those that had a high degree of conjugated unsaturation and had resonance - stabilizing groups were very thermally stable to 200 C, e.g., poly(dicyanoacetylene), poly(ethynylferrocene) and poly(phenylacetylene); while those with labile moieties, such as poly(p-formamidophenylacetylene), among others, suffered some degradation when heated in air. When subjected to gas/polymer interaction effects, the greatest change in electrical conductance was observed when ammonia was used as the gas and poly(p-nitrophenylacetylene) was the detector. Other polymers showed similar behavior. For example, poly(ethynylcarborane), considered to be an electron acceptor also showed a change in electrical conductance when exposed to ammonia, while poly(ethynylpyridine) and poly(ethylidenepyridazine) responded to carbon monoxide. However, for "fire gases" (gases from smoldering cotton), poly(ethynylferrocene) was the most responsive. Thus, the concept of polymers with different electronegativities forming charge-transfer complexes with different gases was found to be operable.

Byrd, N. R.↗

State-of-the-art Space Telescope Digicon performance data

The Digicon has been chosen as the detector for the High Resolution Spectrograph and the Faint Object Spectrograph of the Space Telescope. Both tubes are 512 channel, parallel-output devices and feature CsTe photocathodes on MgF2 faceplates. Using a computer-assisted test facility, the tubes have been characterized with respect to diode array performance, photocathode response (1100-9000 A), and imaging capability. Data are presented on diode dark current and capacitance distributions, pulse height resolution, photocathode quantum efficiency, uniformity and blemishes, dark count rate, distortion, resolution, and crosstalk.

Ginaven, R. O.↗

Low-cycle Fatigue and Dynamic Fracture in Gold Thin Films on SiN Supported Membranes

This slide presentation focuses on the dynamic mechanical response and fatigue behavior in sub-micron thick Au-films deposited onto amorphous Si(sub X)N(sub y) substrates, with spider-web geometry, that were subjected to forced vibration (3-axis random vibration with 2 kHz roll-off frequency). The work is to advance cyrogenic detectors that can operate at 100mK, that is required to create cryogenic detectors that are to search for present day signatures of the big bang.

fatigue↗

Ge photocapacitive MIS infrared detectors

An undoped Ge photocapacitive detector is reported which has peak normalized detectivities at wavelengh 1.4 microns and chopping frequencies 13-1000 Hz of 9 x 10 to the 12th, 4 x 10 to the 9th cm Hz to the 1/2th/W operating respectively at temperatures 77, 195, and 295 K. The observed temperature, spectral, and frequency response of the signal and noise are explained in terms of the measured space charge and interface state properties of the device.

Binari, S. C.↗

Investigation of CCD-digicon detector system characteristics

The reported investigation was undertaken with the aim to develop state-of-the-art detector technology for use in astronomical observations. Basic properties of the Digicon concept are to be extended to the two-dimensional capabilities of CCDs. The basic CCD-Digicon tube configuration utilizes a thinned, backside-illuminated CCD in place of the linear, discrete diode array at the back end of a windowed space telescope (ST) design Digicon tube. It is pointed out that the detector system built around the considered device promises to exhibit high photometric accuracy in combination with large numbers of uniform independent resolution elements. Potential applications include space astronomy missions with capability for observations extending into the extreme ultraviolet spectral region. Attention is given to continuing investigations into the characteristics of CCD response to backside photoelectron bombardment, taking into account the development of charge pulse centroiding readout techniques in combination with magnetic deflection substepping.

Hier, R. G.↗

Observing gamma-ray bursts with the INTEGRAL spectrometer SPI

The spectrometer for INTEGRAL (SPI) is a germanium spectrometer with a wide field of view and will provide the International Gamma Ray Astrophysics Laboratory (INTEGRAL) mission with the opportunity of studying gamma ray bursts. Simulations carried out to assess the response of the instrument using data from real burst data as input are reported on. It is shown that, despite the angular resolution of 3 deg, it is possible to locate the direction of bursts with an accuracy of a few arcmin, while offering the high spectral resolution of the germanium detectors. It is remarked that the SPI field of view is similar to the size of the halo of bursts expected around M 31 on galactic models. The detectability of bursts with such a halo is discussed.

Skinner, G. K.↗

Deconvolution of Energy Spectra in the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC) balloon-borne experiment is designed to perform cosmic- ray elemental spectra measurements from below 100 GeV up to tens TeV for nuclei from hydrogen to iron. The instrument is composed of a silicon matrix detector followed by a carbon target, interleaved with scintillator tracking layers, and a segmented BGO calorimeter composed of 320 individual crystals totalling 18 radiation lengths, used to determine the particle energy. The technique for deconvolution of the energy spectra measured in the thin calorimeter is based on detailed simulations of the response of the ATIC instrument to different cosmic ray nuclei over a wide energy range. The method of deconvolution is described and energy spectrum of carbon obtained by this technique is presented.

Batkov, K. E.↗

Using Model-Based Reasoning for Autonomous Instrument Operation

Multiprobe missions are an important part of NASA's future: Cluster, Magnetospheric Multi Scale, Global Electrodynamics and Magnetospheric Constellation are representatives from the Sun-Earth Connections Theme. To make such missions robust, reliable, and affordable, ideally the many spacecraft of a constellation must be at least as easy to operate as one spacecraft is today. To support this need for scalability, science instrumentation must become increasingly easy to operate, even as this same instrumentation becomes more capable and advanced. Communication and control resources will be at a premium for future instruments. Many missions will be out of contact with ground operators for extended periods either to reduce operations cost or because of orbits that limit communication to weekly perigee transits. Autonomous capability is necessary if such missions are to effectively achieve their operational objectives. An autonomous system is one that acts given its situation in a mission appropriate manner without external direction to achieve mission goals. To achieve this capability autonomy must be built into the system through judicious design or through a built-in intelligence that recognizes system state and manages system response. To recognize desired or undesired system states, the system must have an implicit or explicit understanding of its expected states given its history and self observations. The systems we are concerned with, science instruments, can have stringent requirements for system state knowledge in addition to requirements driven by health and safety concerns. Without accurate knowledge of the system state, the usefulness of the science instrument may be severely limited. At the same time, health and safety concerns often lead to overly conservative instrument operations further reducing the effectiveness of the instrument. These requirements, coupled with overall mission requirements including lack of communication opportunities and tolerance of environmental hazards, frame the problem of constructing autonomous science instruments. we are developing a model of the Low Energy Neutral Atom instrument (LENA) that is currently flying on board the Imager for Magnetosphere-to-Aurora Global Exploration (IMAGE) spacecraft. LENA is a particle detector that uses high voltage electrostatic optics and time-of-flight mass spectrometry to image neutral atom emissions from the denser regions of the Earth's magnetosphere. As with most spacecraft borne science instruments, phenomena in addition to neutral atoms are detected by LENA. Solar radiation and energetic particles from Earth's radiation belts are of particular concern because they may help generate currents that may compromise LENA's long term performance. An explicit model of the instrument response has been constructed and is currently in use on board IMAGE to dynamically adapt LENA to the presence or absence of energetic background radiations. The components of LENA are common in space science instrumentation, and lessons learned by modelling this system may be applied to other instruments. This work demonstrates that a model-based approach can be used to enhance science instrument effectiveness. Our future work involves the extension of these methods to cover more aspects of LENA operation and the generalization to other space science instrumentation.

Johnson, Mike↗

The direct deconvolution of X-ray spectra

The method of deconvolution of proportional counter X-ray spectra as outlined by Blissett and Cruise is reviewed with particular emphasis on low-energy spectra. This method involves the expansion of the incident spectrum in terms of a set of orthonormal singular functions which propagate independently through the detector matrix. When applied to low-energy detectors which typically exhibit absorption features in their efficiency curves, the initial Blissett and Cruise prescription is shown to be unstable. Alternative methods for handling the efficiency are described and evaluated. In the deconvolution of steep spectra, additional distortions are shown to arise as a result of sidelobe oscillations in the effective response functions. A selective weighting procedure is thus introduced to suppress spurious features of this type. Finally, the role of filtering in the deconvolution procedure is discussed and several suitable forms for the filter are suggested.

Kahn, S. M.↗

Influence of large-scale motion on turbulent transport for confined coaxial jets. Volume 1: Analytical analysis of the experimental data using conditional sampling

The existence of large scale coherent structures in turbulent shear flows has been well documented. Discrepancies between experimental and computational data suggest a necessity to understand the roles they play in mass and momentum transport. Using conditional sampling and averaging on coincident two component velocity and concentration velocity experimental data for swirling and nonswirling coaxial jets, triggers for identifying the structures were examined. Concentration fluctuation was found to be an adequate trigger or indicator for the concentration-velocity data, but no suitable detector was located for the two component velocity data. The large scale structures are found in the region where the largest discrepancies exist between model and experiment. The traditional gradient transport model does not fit in this region as a result of these structures. The large scale motion was found to be responsible for a large percentage downstream at approximately the mean velocity of the overall flow in the axial direction. The radial mean velocity of the structures was found to be substantially greater than that of the overall flow.

Brondum, D. C.↗

CALISTO: A Cryogenic Far-Infrared/Submillimeter Observatory

We present a design for a cryogenically cooled large aperture telescope for far-infrared astronomy in the wavelength range 30 micrometers to 300 micrometers. The Cryogenic Aperture Large Infrared Space Telescope Observatory, or CALISTO, is based on an off-axis Gregorian telescope having a 4 m by 6 m primary reflector. This can be launched using an Atlas V 511, with the only optical deployment required being a simple hinged rotation of the secondary reflector. The off-axis design, which includes a cold stop, offers exceptionally good performance in terms of high efficiency and minimum coupling of radiation incident from angles far off the direction of maximum response. This means that strong astronomical sources, such as the Milky Way and zodiacal dust in the plane of the solar system, add very little to the background. The entire optical system is cooled to 4 K to make its emission less than even this low level of astronomical emission. Assuming that detector technology can be improved to the point where detector noise is less than that of the astronomical background, we anticipate unprecedented low values of system noise equivalent power, in the vicinity of 10(exp -19) WHz(exp -0.5), through CALISTO's operating range. This will enable a variety of new astronomical investigations ranging from studies of objects in the outer solar system to tracing the evolution of galaxies in the universe throughout cosmic time.

Cryogenic Aperture Large Infrared Space Telescope ↗

Smoke Detection for the Orion Crew Exploration Vehicle

The Orion Crew Exploration Vehicle (CEV) requires a smoke detector for the detection of particulate smoke products as part of the Fire Detection and Suppression (FDS) system. The smoke detector described in this paper is an adaptation of a mature commercial aircraft design for manned spaceflight. Changes made to the original design include upgrading the materials and electronic to space-qualified parts, and modifying the mechanical design to withstand launch and landing loads. The results of laboratory characterization of the response of the new design to test particles are presented.

Sutin, Brian M.↗

Influence of large-scale motion on turbulent transport for confined coaxial jets. Volume 2: Navier-Stokes calculations of swirling and nonswirling confined coaxial jets

The existence of large scale coherent structures in turbulent shear flows has been well documented. Discrepancies between experimental and computational data suggest a necessity to understand the roles they play in mass and momentum transport. Using conditional sampling and averaging on coincident two-component velocity and concentration velocity experimental data for swirling and nonswirling coaxial jets, triggers for identifying the structures were examined. Concentration fluctuation was found to be an adequate trigger or indicator for the concentration-velocity data, but no suitable detector was located for the two-component velocity data. The large scale structures are found in the region where the largest discrepancies exist between model and experiment. The traditional gradient transport model does not fit in this region as a result of these structures. The large scale motion was found to be responsible for a large percentage of the axial mass transport. The large scale structures were found to convect downstream at approximately the mean velocity of the overall flow in the axial direction. The radial mean velocity of the structures was found to be substantially greater than that of the overall flow.

Weinberg, B. C.↗

Deployment of a Fast-GCMS System to Measure C2 to C5 Carbonyls, Methanol and Ethanol Aboard Aircraft

Through funding of this proposal, a fast response gas chromatograph/mass spectrometer (FGCMS) instrument to measure less than or equal to C4 carbonyl compounds and methanol was developed for the NASA GTE TRACE-P (Global Tropospheric Experiment, Transport And Chemical Evolution Over The Pacific) mission. The system consists of four major components: sample inlet, preconcentration system, gas chromatograph (GC), and detector. The preconcentration system is a custom-built cryogen-conservative system. The GC is a compact, custom-built unit that can be temperature programmed and rapidly cooled. Detection is accomplished with an Agilent Technologies 5973 mass spectrometer. The FGCMS instrument provides positive identification because the compounds are chromatographically separated and mass selected. During TRACE-P, a sample was analyzed every 5 minutes. The FGCMS limit of detection was between 5 and 75 pptv, depending on the compound. The entire instrument package is contained in a standard NASA instrument rack (106 cm x 61 cm x 135 cm), consumes less than 1200 watts and is fully automated with LabViEW 6i. Methods were developed or producing highly accurate gas phase standards for the target compounds and for testing the system in the presence of potential interferents. This report presents data on these tests and on the general overall performance of the system in the laboratory and aboard the DC-8 aircraft during the mission. Vertical profiles for acetaldehyde, methanol, acetone, propanal, methyl ethyl ketone, and butanal from FGCMS data collected over the entire mission are also presented.

Apel, Eric C.↗

Characterizing Weak-Link Effects in Mo/Au Transition-Edge Sensors

We are developing Mo/Au bilayer transition-edge sensors (TESs) for applications in X-ray astronomy. Critical current measurements on these TESs show they act as weak superconducting links exhibiting oscillatory, Fraunhofer-like, behavior with applied magnetic field. In this contribution we investigate the implications of this behavior for TES detectors, under operational bias conditions. This includes characterizing the logarithmic resistance sensitivity with temperature, (alpha, and current, beta, as a function of applied magnetic field and bias point within the resistive transition. Results show that these important device parameters exhibit similar oscillatory behavior with applied magnetic field, which in turn affects the signal responsivity, noise and energy resolution.

Smith, Stephen↗

MODIS Reflective Solar Bands On-Orbit Calibration and Performance

The design of the MODIS instrument was driven by the scientific community's desire to have near-daily global coverage at moderate resolution (1 km) with a comprehensive spectral coverage from visible to long-wave infrared wavelengths. Since their launches in 1999 and 2002, respectively, the Terra and Aqua MODIS instruments have made continuous global observations and generated numerous data products to help users worldwide with their studies of the Earth's system and its short- and long-term changes. The 20 reflective solar bands (RSB) with wavelengths from 0.41 to 2.2 m collect data at three nadir spatial resolutions: 250 m, 500 m, and 1 km. The solar diffuser (SD) coupled with the solar diffuser stability monitor (SDSM) provide a reflectance-based calibration on-orbit. In addition, lunar observations and response trends from pseudo-invariant desert sites are used to characterize the response versus scan- angle changes on-orbit. This paper provides a brief overview of MODIS RSB calibration algorithms, as implemented in the latest Level 1B version 6.1, operational activities, on-orbit performance, remaining challenges and potential improvements. Results from the SD and SDSM measurements show a wavelength and mirror side dependent degradation in RSB responses, with the largest degradation at the shortest wavelengths, particularly for Terra MODIS. Aqua MODIS has experienced far less degradation of its optics and on-board calibrators compared to Terra MODIS, resulting in an overall better performance. With the exception of Aqua band 6, there have been no new noisy or inoperable detectors in the RSB of either instrument during post-launch operations. As the instruments age and continue to endure the space environment, the detectors and optical systems degrade. The challenges associated with incorporating these on-orbit changes to ensure a production of high-quality calibrated L1B data products are also discussed in this paper.

solar diffuser stability monitor↗

Rocket/Radar Sporadic-E Experiment Conducted during the El Coqui 2 Campaign

In order to investigate the complex electrodynamics and neutral-plasma coupling inherent to sporadic-E layers in the earth's mid-latitude ionosphere, a series of rocket/radar experiments were planned as part of the NASA El Coqui H Campaign from Tortuguero Launch Range, Puerto Rico, in March-April, 1998. The rocket experiments consisted of two pairs of "mother-daughter" payloads with limited apogees so that the payloads "hovered" in the sporadic-E region (95-125 km). Each payload pair included vector DC and AC electric field detectors, a highly accurate flux-gate DC magnetometer, an ion mass spectrometer, an ionization gauge, and spaced-electric field receivers to measure the wavelength and phase velocity of the unstable plasma waves. Separate rockets were included to simultaneously carry aloft TMA trails to measure the neutral wind and its velocity shear, believed responsible for the sporadic-E layer formation. In addition to the rocket experiments, incoherent scatter radar measurements of plasma density and drift velocity were gathered almost every night during the 3 week campaign. Continuous VHF backscatter radar operations were carried out from a site near Salinas, Puerto Rico, where 3-m backscatter echoes were observed associated with sporadic-E and other types of low altitude ionospheric layers. Other radars that operated during the campaign included an HF backscatter system near Ponce, Puerto Rico, and a second VHF backscatter radar set up near Aguadila Puerto Rico. On 24 March 1998, one of the instrumented rockets was launched, attaining an apogee of 129 km. The payloads successfully pierced an intense sporadic-E layer observed by both the Arecibo radar and the in-situ density and ion mass spectrometer probes. In-situ DC electric fields revealed very low (about 1-2 mV/m) ambient fields with small amplitude structures of the same order. No high frequency (short scale) waves were observed, consistent with the VHF backscatter observations at the time of the launch. An overview of the observations will be presented.

Pfaff, R.F.↗