Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

The DarkSide-20k TPC and underground argon cryogenic system

DarkSide-20k (DS-20k) will exploit the physical and chemical properties of liquid argon (LAr) housed within a large dual-phase time project chamber (TPC) in its direct search for dark matter. The TPC will utilize a compact, integrated design with many novel features to enable the 20t fiducial volume of underground argon. Underground Argon (UAr) is sourced from underground CO _2 2 wells and depleted in the radioactive isotope ^{39} 39 Ar, greatly enhancing the experimental sensitivity to dark matter interactions. Sourcing and transporting the \mathcal{O} 𝒪 (100t) of UAr for (DS-20k) is costly, and a dedicated single-closed-loop cryogenic system has been designed, constructed, and tested to handle the valuable UAr. We present an overview of the (DS-20k) TPC design and the first results from the UAr cryogenic system.

Thorpe, Thomas N.↗

Large Cryogenic Germanium Detector (Final Report)

The goal of this project was to investigate possible ways of increasing the size of cryogenic Ge detectors. This project identified two possible approaches to increasing the individual cryogenic Ge detector size. The first approach relies on using the existing technology for growing detector-grade (high-purity) germanium crystals of dislocation density 100-7000 cm -2 . The second approach is to consider dislocation-free Ge crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background Characterization and Discrimination in the Final Analysis of the CDMS II Phase of the Cryogenic Dark Matter Search

The Cryogenic Dark Matter Search (CDMS) is designed to detectWeakly-Interacting Massive Particles (WIMPs) in the Milky Way halo. The phase known as CDMS II was performed in the Soudan Underground Laboratory. The final set of CDMS II data, collected in 2007-8 and referred to as Runs 125-8, represents the largest exposure to date for the experiment. We seek collisions between WIMPs and atomic nuclei in disk-shaped germanium and silicon detectors. A key design feature is to keep the rate of collisions from known particles producing WIMP-like signals very small. The largest category of such background is interactions with electrons in the detectors that occur very close to one of the faces of the detector. The next largest category is collisions between energetic neutrons that bypass the experimental shielding and nuclei in the detectors. Analytical efforts to discriminate these backgrounds and to estimate the rate at which such discrimination fails have been refined and improved throughout each phase of CDMS. Next-generation detectors for future phases of CDMS require testing at cryogenic test facilities. One such facility was developed at the University of Minnesota in 2007 and has been used continuously since then to test detectors for the next phase of the experiment, known as SuperCDMS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling Dynamic Fracture of Cryogenic Pellets

This work is part of an investigation with the long-range objective of predicting the size distribution function and velocity dispersion of shattered pellet fragments after a large cryogenic pellet impacts a solid surface at high velocity. The study is vitally important for the shattered pellet injection (SPI) technique, one of the leading technologies being implemented at ORNL for the mitigation of disruption damage on current tokamaks and ITER. The report contains three parts that are somewhat interwoven. In Part I we formulated a self-similar model for the expansion dynamics and velocity dispersion of the debris cloud following pellet impact against a thick (rigid) target plate. Also presented in Part I is an analytical fracture model that predicts the nominal or mean size of the fragments in the debris cloud and agrees well with known SPI data. The aim of Part II is to gain an understanding of the pellet fracturing process when a pellet is shattered inside a miter tube with a sharp bend. Because miter tubes have a thin stainless steel (SS) wall a permanent deformation (dishing) of the wall is produced at the site of the impact. A review of the literature indicates that most projectile impact on thin plates are those for which the target is deformed and the projectile is perfectly rigid. Such impacts result in “projectile embedding” where the projectile speed is reduced to zero during the interaction so that all the kinetic energy (KE) of the projectile goes into the energy stored in plastic deformation. Much of the literature deals with perforation of the target. The problem here is quite different; the softer pellet easily undergoes complete material failure causing only a small transfer of KE to stored energy of wall deformation. For the real miter tube, we derived a strain energy function for the wall deflection using a non-linear (plastic) stress-strain relation for 304 SS. Using a dishing profile identical to the linear Kirchkoff-Love profile (for lack of a rigorously derived profile) we derived the strain energy associated with the deflection and applied a virtual work principle to find a relationship between the impact (load) pressure to the measured wall deflection depth. The inferred impact pressure was in good agreement with the expected pressure for oblique cryogenic pellet impacts where the pellet shear stress causing cleavage fracture is well above the yield stress for pure shear. The section is concluded with additional discussion on how this wall deformation data lends further support to the analytical fracture model presented in Part I. In Part III we present three different size distribution models. A summary, with a few brief suggestions for a follow on study, is provided at the end of this report.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionization Collection in Detectors of the Cryogenic Dark Matter Search

Determining the composition of dark matter is at the forefront of modern scientific research. There is compelling evidence for the existence of vast quantities of dark matter throughout the universe, however it has so-far eluded all direct detection efforts and its identity remains a mystery. Weakly interacting massive particles (WIMPs) are a favored dark matter candidate and have been the primary focus of direct detection for several decades. The Cryogenic Dark Matter Search (CDMS) has developed the Z-dependent Ionization and Phonon (ZIP) detector to search for such particles. Typically made from germanium, these detectors are capable of distinguishing between electromagnetic background and a putative WIMP signal through the simultaneous measurement of ionization and phonons produced by scattering events. CDMS has operated several arrays of these detectors at the Soudan Underground Laboratory (Soudan, MN, USA) resulting in many competitive (often world-leading) WIMP exclusion limits. This dissertation focuses on ionization collection in these detectors under the sub-Kelvin, low electric field, and high crystal purity conditions unique to CDMS. The design and performance of a fully cryogenic HEMT-based amplifier capable of achieving the SuperCDMS SNOLAB ionization energy resolution goal of 100 eVee is presented. The experimental apparatus which has been used to record electron and hole properties under CDMS conditions is described. Measurements of charge transport, trapping, and impact ionization as a function of electric field in two CDMS detectors are shown, and the ionization collection efficiency is determined. The data is used to predict the error in the nuclear recoil energy scale under both CDMSlite and iZIP operating modes. A two species, two state model is developed to describe how ionization collection and space charge generation in CDMS detectors are controlled by the presence of “overcharged” D- donor and A+ acceptor impurity states. The thermal stability of these states is exclusive to sub-Kelvin operation, explaining why ionization collection in CDMS detectors differs from similar semiconductor detectors operating at higher temperature. This work represents a solid foundation for the understanding ionization collection in CDMS detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

First 5 tower WIMP-search results from the Cryogenic Dark Matter Search with improved understanding of neutron backgrounds and benchmarking

Non-baryonic dark matter makes one quarter of the energy density of the Universe and is concentrated in the halos of galaxies, including the Milky Way. The Weakly Interacting Massive Particle (WIMP) is a dark matter candidate with a scattering cross section with an atomic nucleus of the order of the weak interaction and a mass comparable to that of an atomic nucleus. The Cryogenic Dark Matter Search (CDMS-II) experiment, using Ge and Si cryogenic particle detectors at the Soudan Underground Laboratory, aims to directly detect nuclear recoils from WIMP interactions. This thesis presents the first 5 tower WIMP-search results from CDMS-II, an estimate of the cosmogenic neutron backgrounds expected at the Soudan Underground Laboratory, and a proposal for a new measurement of high-energy neutrons underground to benchmark the Monte Carlo simulations. Based on the non-observation of WIMPs and using standard assumptions about the galactic halo [68], the 90% C.L. upper limit of the spin-independent WIMPnucleon cross section for the first 5 tower run is 6.6 × 10 -44 cm 2 for a 60 GeV/c 2 WIMP mass. A combined limit using all the data taken at Soudan results in an upper limit of 4.6×10 -44 cm 2 at 90% C.L.for a 60 GeV/c2 WIMP mass. This new limit corresponds to a factor of ~3 improvement over any previous CDMS-II limit and a factor of ~2 above 60 GeV/c 2 better than any other WIMP search to date. This thesis presents an estimation, based on Monte Carlo simulations, of the nuclear recoils produced by cosmic-ray muons and their secondaries (at the Soudan site) for a 5 tower Ge and Si configuration as well as for a 7 supertower array. The results of the Monte Carlo are that CDMS-II should expect 0.06 ± 0.02+0.18 -0.02 /kgyear unvetoed single nuclear recoils in Ge for the 5 tower configuration, and 0.05 ± 0.01+0.15 -0.02 /kg-year for the 7 supertower configuration. The systematic error is based on the available underground neutron data (that we are aware of) relevant to the unvetoed neutron population. Therefore, for the first 5 tower run, a prediction of < 0.2 events from cosmogenic neutrons was obtained. Furthermore, this thesis describes a proposal for a new measurement of the absolute flux of high-energy neutrons (>60 MeV) deep underground. The cosmogenic neutron detector could measure, at a depth of 2000 meters of water equivalent, a rate of 70 ± 8 (stat) events/year. Based on these studies, the benefits of using a neutron multiplicity meter as a component of active shielding in experiments with similar background concerns are described.

79 ASTRONOMY AND ASTROPHYSICS↗

Cryogenic Frostpoint Hygrometer (CFH) Instrument Handbook

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Cryogenic Frostpoint Hygrometer (CFH) is a small, balloon-borne instrument that provides highly accurate measurements of water vapor in the atmosphere. The CFH, although highly modified, is based upon the National Oceanic and Atmospheric Administration (NOAA)/Climate Monitoring and Diagnostic Laboratory (CMDL) frostpoint hygrometer (FPH) that has been flown in Boulder, Colorado, since 1980. The CFH has a significantly greater sensitivity to water vapor than standard radiosondes, as it can measure the frostpoint or dewpoint temperatures at an accuracy better than 0.2 K corresponding to water volume mixing ratios accuracies of only a few parts per million. The main instrument part is a small mirror, which is cooled by a cryogen in order to be covered with a thin layer of water vapor condensate. A pair of photodiodes detects the condensation on the temperature-controlled mirror. The phase of the condensate is controlled by a force-freezing algorithm, allowing for clear interpretation of the dew point versus frostpoint. The replacement of analog electronics with a microprocessor, a feedback controller, and thermistor calibration have led to improved accuracy and performance of the CFH over its predecessors. Further characteristics like reduced power consumption and low instrument weight made the CFH a successful instrument to perform in situ balloon-borne measurements of water vapor in the upper troposphere and lower stratosphere. CFH measurements are now used worldwide to validate radiosonde, satellite, and ground-based profiler measurements.

47 OTHER INSTRUMENTATION↗

Scanning Quantum Cryogenic Atom Microscope (Final Technical Report)

The SQCRAMscope, Scanning Quantum Cryogenic Atom Microscope, is a novel scanning probe microscope we developed during this DOE fund period. It is now capable of imaging transport in cryogenically cooled solid-state samples, as we have recently demonstrated with iron-based pnictide superconductors. As such, it opens a new frontier in the quantum-based metrology of materials and is the first example of the direct marriage of ultracold AMO physics with condensed matter physics. We predict the SQCRAMscope will become an important element in the toolbox for exploring strongly correlated and topologically nontrivial materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated Insulation System for Cryogenic Automotive Tanks (iCAT)

The objective of this project was to develop a state-of-the-art Integrated Insulation System for Cryogenic Automotive Tanks (iCAT) using new lightweight, commercially available materials applied with innovative methods that could demonstrate the DOE heat leak targets (< 5-7 W) for a 100 liter (L) cryogenic hydrogen storage tank and require little to no periodic maintenance. The project team focused on developing an integrated system based on a degraded vacuum (from 0.001 torr up to 0.1 torr) environment [Moderate Vacuum], and compared this system to the standard multi-layer insulation (MLI) high vacuum (HV) environment (< 10E-4 torr).

08 HYDROGEN↗

Millikelvin Cryogenics at Fermilab

Millikelvin cryogenics is an emergent area for Fermilab with broad applications in particle detection for the cosmic frontier and quantum information science. Fermilab Cryogenic Engineering currently supports multiple experiments, including the SuperCDMS SNOLAB and ADMX dark matter experiments, along with several millikelvin test facilities. More programs are expected to come online in future.

43 PARTICLE ACCELERATORS↗

NECQST: Novel Electronics for Cryogenic Quantum Sensors Technology

Development of low-noise cryogenic readout circuits for SNSPDs based on state-of-the art, commercially available SiGe HBT technology, operating at a range of 1-4 Kelvin. Targeting a reduction of the timing jitter of SNSPDs (from the current record of 2.7 ps FWHM at 400 nm), and a reduction in the power dissipation allowed by the development of dedicated low-noise cryogenic amplifiers, which will enable the scaling of ultra-low-jitter SNSPDs to large arrays. Such performance advances will directly benefit the Caltech/Fermilab INQNET (Intelligent Quantum Networks & Technologies) program, which aims to demonstrate high-rate quantum communication at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

C1Po2D-04: Cryogenic Testing of the First HL-LHC Q1/Q3 Cryo-Assembly at

In early 2023, Fermilab is conducting horizontal cryogenic testing of the first Q1/Q3 Cryo-Assembly for the high-luminosity LHC upgrade (HL-LHC). The Cryo-Assembly was installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of this test include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench.

Rabehl, R.↗

Development of an Advanced Hydrogen Energy Storage System using Aerogel in a Cryogenic Flux Capacitor

The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by the principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m 2 /g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature and high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, constructed from readily available commercial materials, and lends itself to a range of pressure applications. The project team designed and manufactured the CFC, integrating it into a set of temperature-controlled flow loops. The CFC test setup was validated against existing data from previous NASA work. Tests used bottled hydrogen gas for test validation. A cryogenic fluid, nitrogen, flowed through a metered control system. Hydrogen temperature, pressure, and flow rates, as well as the temperature control targets, provided all necessary control targets. The team analyzed the recorded data and updated the Technology Maturation Plan based on the results of the test, making recommendations for a follow-up test, scale-up, and maturation pathway. For the engineering development and maturation of CFC hydrogen storage technology, a Techno-Economic Assessment (TEA) and Commercialization Plan for the integration of this technology with various power generation assets were produced. A companion analytical model was developed, experimentally validated, compared against performance metric, and used to tune the model and scale up the technology.

08 HYDROGEN↗

Towards a Next Generation Search for Time-Reversal Violation Using Optically Addressable Nuclei in Cryogenic Solids (Final Technical Report, September 2018 - August 2023)

Certain rare pear-shaped nuclei have unmatched sensitivity to new kinds of forces between subatomic particles that are not the same when the arrow of time is reversed. Such forces are believed to be responsible for the near absence of antimatter in the observable Universe. These rare isotopes, some for the first time, will be produced in large numbers at the Facility for Rare Isotope Beams currently under operating at Michigan State University providing an unprecedented opportunity to probe for new physics. In anticipation, we are using abundant isotopes to develop new techniques to manipulate nuclei embedded inside an optically transparent solid at cryogenic temperatures. Implantation into a solid, such as neon and argon, is potentially an effective way to both efficiently capture and repeatedly probe the small number of rare nuclei, such as radium and protactinium. An optically transparent host medium at cryogenic temperatures would allow for the laser manipulation of the nuclei in a thermally quiet and stable environment for a wide variety of guest species such as polar molecules. In such systems, the nuclei are exposed to extraordinarily large electric fields and magnetic field gradients, which significantly amplifies the measurability of certain time-reversal violating effects. The potential sensitivity of this new approach could be at least a few hundred times greater than the current leading experiment which uses stable mercury atoms. We report on the design considerations and preliminary performance of an instrument used to produce and implant molecules into a frozen argon solid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monitoring Helium Cryogen Usage with iFix Software at IB1 Test Facility

At the IB1 facility of the Applied Physics and Superconducting Technology Directorate within the Cryogenic Division at Fermilab, liquid helium is essential to the testing activities. The test stands used require large amounts of Helium to test the thermal and superconducting cavities and magnets. The liquid helium that enters the test stand is monitored through a series of valves and controls to determine the start and stop for monitoring time. There are 3 phases of cryogen usage that must be considered for each stand, cooldown, warming and overnight mode. With a new system in place, cold hour tracking will be more objective and precise within each test stand ensuring better calculations for user s fees that will provide funding for the replenishment of helium and continual operation at IB1.

Trillo, Angelica↗

Cryogenic Testing of HL-LHC Q1/Q3 Cryo-Assemblies at Fermilab

Fermilab is conducting horizontal cryogenic testing of Q1/Q3 Cryo-Assemblies for the high-luminosity LHC upgrade (HL-LHC). Cryo-Assemblies are installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of these tests include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressures up to 18 bar with full helium recovery after a quench. This paper presents the operational experience gained from the first tests as well as improvements for subsequent tests.

Rabehl, R. [Fermilab]↗

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]↗

Fermilab PIP-II CDS & CM Cryogenic Controls System

Details on Final design for Cryogenic Electrical & Controls System for Fermilab' s next-gen particle accelerator PIP-II. Electrical Controls System includes instrumentation and controls of Cryogenics Distribution System and Cryomodules. Design includes Siemens PCS7 Controls System with 26 Remote IO Rittal Cabinets and 48 Relay Racks for Temperature Readouts, Valve Positioners, Level, Heater Controls etc. Electrical Drawings and Design have been completed with focus now on fabrication of the 26 Rittal Cabinets and 48 Relay Racks. All materials have been procured. EPICS will be used as a SCADA system communicating to S7 Controllers via OPC UA.

Patel, Pratik [Fermilab]↗