Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Survival of endospores of Bacillus subtilis on spacecraft surfaces under simulated martian environments: implications for the forward contamination of Mars

Experiments were conducted in a Mars simulation chamber (MSC) to characterize the survival of endospores of Bacillus subtilis under high UV irradiation and simulated martian conditions. The MSC was used to create Mars surface environments in which pressure (8.5 mb), temperature (-80, -40, -10, or +23 degrees C), gas composition (Earth-normal N2/O2 mix, pure N2, pure CO2, or a Mars gas mix), and UV-VIS-NIR fluence rates (200-1200 nm) were maintained within tight limits. The Mars gas mix was composed of CO2 (95.3%), N2 (2.7%), Ar (1.7%), O2 (0.2%), and water vapor (0.03%). Experiments were conducted to measure the effects of pressure, gas composition, and temperature alone or in combination with Mars-normal UV-VIS-NIR light environments. Endospores of B. subtilis, were deposited on aluminum coupons as monolayers in which the average density applied to coupons was 2.47 x 10(6) bacteria per sample. Populations of B. subtilis placed on aluminum coupons and subjected to an Earth-normal temperature (23 degrees C), pressure (1013 mb), and gas mix (normal N2/O2 ratio) but illuminated with a Mars-normal UV-VIS-NIR spectrum were reduced by over 99.9% after 30 sec exposure to Mars-normal UV fluence rates. However, it required at least 15 min of Mars-normal UV exposure to reduce bacterial populations on aluminum coupons to non-recoverable levels. These results were duplicated when bacteria were exposed to Mars-normal environments of temperature (-10 degrees C), pressure (8.5 mb), gas composition (pure CO2), and UV fluence rates. In other experiments, results indicated that the gas composition of the atmosphere and the temperature of the bacterial monolayers at the time of Mars UV exposure had no effects on the survival of bacterial endospores. But Mars-normal pressures (8.5 mb) were found to reduce survival by approximately 20-35% compared to Earth-normal pressures (1013 mb). The primary implications of these results are (a) that greater than 99.9% of bacterial populations on sun-exposed surfaces of spacecraft are likely to be inactivated within a few tens of seconds to a few minutes on the surface of Mars, and (b) that within a single Mars day under clear-sky conditions bacterial populations on sun-exposed surfaces of spacecraft will be sterilized. Furthermore, these results suggest that the high UV fluence rates on the martian surface can be an important resource in minimizing the forward contamination of Mars. c2003 Elsevier Inc. All rights reserved.

Bacillus subtilis/growth & development/physiology/↗

Gas Contamination Effects on Pulse Tube Performance

Experiments were performed to quantify the effect of contamination in the helium working gas of a typical pulse tube cryocooler operating at 60 K with 1 W of applied heating load.

Gas Contamination helium gas heating load↗

DSCOVR Contamination Lessons Learned

The Triana observatory was built at NASA GSFC in the late 1990's, then placed into storage. After approximately ten years it was removed from storage and repurposed as the Deep Space Climate Observatory (DSCOVR). This presentation outlines the contamination control program lessons learned during the integration, test and launch of DSCOVR.

DSCOVR↗

Analysis of Process Gases and Trace Contaminants in Membrane-Aerated Gaseous Effluent Streams.

In membrane-aerated biofilm reactors (MABRs), hollow fibers are used to supply oxygen to the biofilms and bulk fluid. A pressure and concentration gradient between the inner volume of the fibers and the reactor reservoir drives oxygen mass transport across the fibers toward the bulk solution, providing the fiber-adhered biofilm with oxygen. Conversely, bacterial metabolic gases from the bulk liquid, as well as from the biofilm, move opposite to the flow of oxygen, entering the hollow fiber and out of the reactor. Metabolic gases are excellent indicators of biofilm vitality, and can aid in microbial identification. Certain gases can be indicative of system perturbations and control anomalies, or potentially unwanted biological processes occurring within the reactor. In confined environments, such as those found during spaceflight, it is important to understand what compounds are being stripped from the reactor and potentially released into the crew cabin to determine the appropriateness or the requirement for additional mitigation factors. Reactor effluent gas analysis focused on samples provided from Kennedy Space Center's sub-scale MABRs, as well as Johnson Space Center's full-scale MABRs, using infrared spectroscopy and gas chromatography techniques. Process gases, such as carbon dioxide, oxygen, nitrogen, nitrogen dioxide, and nitrous oxide, were quantified to monitor reactor operations. Solid Phase Microextraction (SPME) GC-MS analysis was used to identify trace volatile compounds. Compounds of interest were subsequently quantified. Reactor supply air was examined to establish target compound baseline concentrations. Concentration levels were compared to average ISS concentration values and/or Spacecraft Maximum Allowable Concentration (SMAC) levels where appropriate. Based on a review of to-date results, current trace contaminant control systems (TCCS) currently on board the ISS should be able to handle the added load from bioreactor systems without the need for secondary mitigation.

Gaseous Effluent Streams↗

Monolithic Trace-Contaminant Sorbents Fabricated from 3D-Printed Polymer Precursors

The current trace-contaminant (TC) removal technology for use in Extravehicular Activities (EVAs) involves the use of a packed bed of acid-impregnated granular charcoal, which is difficult to regenerate. In this paper, results are presented on the development of vacuum-regenerable TC sorbents for use in the Portable Life Support System (PLSS). The sorbents are derived from 3D-printed polymer monoliths (e.g., honeycomb structures), which are then carbonized and activated in order to develop porosity, and also to enhance the TC-sorption capacity. Results are presented on the following aspects of carbon-sorbent development: (1) precursor selection; (2) monolith fabrication; (3) shape retention and strength; (4) carbon surface and porosity characterization; (5) TC-sorption capacity and vacuum-regeneration; (6) pressure drop; and (7) sub-scale sorbent prototype. The use of predominantly microporous monolithic carbon is associated with the following benefits: (a) high TC-sorption capacity; (b) low pressure drop; (c) rapid vacuum (pressure-swing) desorption due to thin monolith walls and low pressure drop; (d) good thermal management (high thermal conductivity and low adsorption/desorption thermal effects associated with physisorption); and (e) good resistance to dusty environments.

Portable Life Support System (PLSS)↗

Clean Air Shower Curtain for Protection of Contamination Sensitive Telescopes on the Ariane 5 Launcher

The launch of the James Webb Space Telescope (JWST) was successfully performed by Ariane 5 from French Guiana on December 25th 2021. The unique nature of the JWST mission led to various adaptations of the Ariane 5 launch system to fulfill stringent cleanliness and hygrometry requirements all along the launch preparation. JWST integration and test activities in the Final Assembly Building (BAF) had to be performed in ISO Class 7 equivalent conditions under Volatile Organic Compounds (VOC) protection and monitoring. For this purpose, a dedicated air supply system equipped with Airborne Molecular Contamination (AMC) filters was installed in the umbilical mast. The fairing itself was specially sealed to protect the inner environment, and to, guarantee ISO Class 7, the BAF Composite Hall (BAF-HC) facilities were upgraded with a removable “Air Shower Curtain” (AShC) containment enclosure between the mobile platforms around JWST. The preparation of these Ariane 5 launch system adaptations started several years before the launch campaign with close cooperation and coordination between Arianespace, ArianeGroup, the European Space Agency (ESA) and the National Aeronautics and Space Administration (NASA). This paper describes their specificities and addresses the challenges experienced to achieve the successful mission preparation.

Contamination Control, James Webb Space Telescope,↗

Clean Air Shower Curtain for Protection of Contamination Sensitive Telescopes on the Ariane 5 Launcher

The launch of the James Webb Space Telescope (JWST) was successfully performed by Ariane 5 from French Guiana on December 25th 2021. The unique nature of the JWST mission led to various adaptations of the Ariane 5 launch system to fulfill stringent cleanliness and hygrometry requirements all along the launch preparation. JWST integration and test activities in the Final Assembly Building (BAF) had to be performed in ISO Class 7 equivalent conditions under Volatile Organic Compounds (VOC) protection and monitoring. For this purpose, a dedicated air supply system equipped with Airborne Molecular Contamination (AMC) filters was installed in the umbilical mast. The fairing itself was specially sealed to protect the inner environment, and to, guarantee ISO Class 7, the BAF Composite Hall (BAF-HC) facilities were upgraded with a removable “Air Shower Curtain” (AShC) containment enclosure between the mobile platforms around JWST. The preparation of these Ariane 5 launch system adaptations started several years before the launch campaign with close cooperation and coordination between Arianespace, ArianeGroup, the European Space Agency (ESA) and the National Aeronautics and Space Administration (NASA). This paper describes their specificities and addresses the challenges experienced to achieve the successful mission preparation.

Contamination Control, James Webb Space Telescope,↗

EMU Ventilation Loop Simulation and Assessment of Contamination of the EMU Sublimator Hydrophilic Coating

Controlling moisture is a critical function performed in the space suit during extra vehicular activity (EVA) missions. Currently, this function is carried out by a sublimator, which is coated with a hydrophilic material. Tests have shown that siloxane compounds can off gas from the helmet absorption pad extension (HAP-E) and helmet absorption band (HAB) when they are at elevated temperatures and initial testing indicated that siloxanes could damage the hydrophilic coating. Therefore, more representative testing was needed. Important test considerations were source and destination kinetics, system geometries, scrubbing efficacy by the activated charcoal from the Metox canister, and other benefits that derive from active condensation occurring on the hydrophilic coating during exposure. A ventilation loop that was originally constructed to test hardware for control of CO2 and trace contaminants under EVA conditions was modified to conduct the siloxane off gassing tests. A vacuum compatible acrylic chamber was installed to simulate the suit volume. A steel beaker located in the chamber contained the HAP-E and HAB materials and was heated with two band heaters. The flow exiting the chamber passed through a LiOH cannister, which contained carbon beds to simulate their function in the Metox. The flow then was directed into a smaller volume that contained a coupon, which was coated with the hydrophilic material and was maintained at 10°C (50°F). Moisture was injected upstream of the suit volume simulator to maintain the dew point between 12.7°C (55°F) and 18.3°C (65°F). The pressure was controlled to between 3.8 and 4.4 psia, and the flow was held at 6 acfm. The system was run for an equivalent of 25 ten-hour EVAs, where the HAP-E/HAB materials were changed out after each EVA. The effect of the potential off gassing on the coupon was measured after each EVA period.

PLSS↗

NASA Engineering and Safety Center Technical Bulletin No. 09-05: Self-Contained Oxygen Generator: Effects of Organic Contamination, Briquette Fracturing, Pressure Containment, and Variations in Chemical Composition

A Self-Contained Oxygen Generator (SCOG) produces breathable oxygen (O 2 ) by using chemically-reactive briquettes that begin producing O 2 when mechanically ignited. Contamination with organic material of, or manufacturing defects in, the briquettes have been shown to lead to conditions that can cause an explosive failure

Self Contained Oxygen Generator↗

Per- and Polyfluoroalkyl Substances: A Preliminary Evaluation of Groundwater Contamination in the Western States

Per- and Polyfluoroalkyl Substances (PFAS) are a manufactured group of chemicals that have been used since the 1940s. PFAS break down very slowly and studies show that exposure to these chemicals may cause negative reproductive effects, developmental delays in children, increased risk of some cancers, and interference with the body’s natural hormones. On June 15, 2022, EPA issued interim updated drinking water health advisories for the two most widely studied PFAS, perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS). The concentrations for the health advisory limits are 0.004 parts per trillion (ppt) and 0.02 ppt respectively. Because data is often reported in combined PFOA and PFOS concentrations, and for ease of data visualization, concentrations of the two chemicals will be discussed as a single, summed value and will be compared to the combined health advisory limits of 0.024 ppt. Due to the recently published near-zero health advisory limits and the known negative health effects, a map of estimated PFAS groundwater contamination was created using ArcGIS Pro and geostatistical tools to inform the public and determine which regions are most at-risk.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen Contaminant Detector

This presentation describes fiscal year 2022 status and accomplishments for NREL's Hydrogen Contaminant Detector project.

analyzer↗

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surface Regulating of a Double–Perovskite Electrode for Protonic Ceramic Fuel Cells to Enhance Oxygen Reduction Activity and Contaminants Poisoning Tolerance

Protonic ceramic fuel cells (PCFCs) are one of the most efficient energy conversion devices. However, the performance of current PCFCs is greatly limited by the sluggish oxygen reduction reaction (ORR) kinetics and the fast degradation of cathode due to contaminants poisoning (such as Cr species and steam). In this work, we report a surface regulating of a double perovskite PrBa 0.5 Sr 0.5 Co 1.5 Fe 0.5 O 5+δ (PBSCF) cathode by a Pr 0.9 Fe 0.7 Co 0.3 O 3 (PFC) catalyst coating to enhance the ORR activity and stability. When tested in direct contact with Cr in the air with 3% H 2 O at 650 °C, the polarization resistance (Rp) of the PFC-PBSCF electrode increases from $\approx$0.39 to 0.45 Ω cm 2 after 100 h operation; in contrast, the R p of a PBSCF electrode increases from 0.63 to 0.82 Ω cm 2 . Further, a PCFC with the PFC-PBSCF cathode demonstrates an excellent peak power density ($\approx$1.08 W cm -2 at 650 °C) and significantly enhanced durability (degradation rate of 0.03 % h -1 ), much better than those of the cells with a PBSCF cathode ($\approx$0.75 W cm -2 and degradation rate of 0.12 % h -1 ). Raman spectroscopy and density functional theory calculations indicate that the PFC catalyst coating diminishes the formation of Cr species, such as (Ba 1-x Sr x )CrO 4 , on the cathode surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the ATLAS top mass measurements and the potential for stealth stop contamination

The discovery of the stop — the Supersymmetric partner of the top quark — is a key goal of the physics program enabled by the Large Hadron Collider. Although much of the accessible parameter space has already been probed, all current searches assume the top mass is known. This is relevant for the “stealth stop” regime, which is characterized by decay kinematics that force the final state top quark off its mass shell; such decays would contaminate the top mass measurements. We investigate the resulting bias imparted to the template method based ATLAS approach. A careful recasting of these results shows that effect can be as large as 2.0 GeV, comparable to the current quoted uncertainty on the top mass. Thus, a robust exploration of the stealth stop splinter requires the simultaneous consideration of the impact on the top mass. Additionally, we explore the robustness of the template technique, and point out a simple strategy for improving the methodology implemented for the semi-leptonic channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗