Quantitative Measurements of Electronically Excited CH Concentration in Normal Gravity and Microgravity Coflow Laminar Diffusion Flames

With the conclusion of the SLICE campaign aboard the ISS in 2012, a large amount of data was made available for the analysis of the effect of microgravity on laminar coflow diffusion flames. Previous work focused on the study of sooty flames in microgravity as well as the ability of numerical models to predict its formation in a simplified buoyancy-free environment. The current work shifts the investigation to soot-free flames, putting an emphasis on the chemiluminescence emission from electronically excited CH (CH*). This radical species is of significant interest in combustion studies: it has been shown that the electronically excited CH spatial distribution is indicative of the flame front position and, given the relatively simple diagnostic involved with its measurement, several works have been done trying to understand the ability of electronically excited CH chemiluminescence to predict the total and local flame heat release rate. In this work, a subset of the SLICE nitrogen-diluted methane flames has been considered, and the effect of fuel and coflow velocity on electronically excited CH concentration is discussed and compared with both normal gravity results and numerical simulations. Experimentally, the spectral characterization of the DSLR color camera used to acquire the flame images allowed the signal collected by the blue channel to be considered representative of the electronically excited CH emission centered around 431 nm. Due to the axisymmetric flame structure, an Abel deconvolution of the line-of-sight chemiluminescence was used to obtain the radial intensity profile and, thanks to an absolute light intensity calibration, a quantification of the electronically excited CH concentration was possible. Results show that, in microgravity, the maximum flame electronically excited CH concentration increases with the coflow velocity, but it is weakly dependent on the fuel velocity; normal gravity flames, if not lifted, tend to follow the same trend, albeit with different peak concentrations. Comparisons with numerical simulations display reasonably good agreement between measured and computed flame lengths and radii, and it is shown that the integrated electronically excited CH emission scales proportionally to the computed total heat release rate; the two-dimensional electronically excited CH spatial distribution, however, does not appear to be a good marker for the local heat release rate.

chemiluminescence↗

Quantitative Measurements of CH* Concentration in Normal Gravity and Microgravity Coflow Laminar Diffusion Flames

With the conclusion of the SLICE campaign aboard the ISS in 2012, a large amount of data was made available for the analysis of the effect of microgravity on laminar coflow diffusion flames. Previous work focused on the study of sooty flames in microgravity as well as the ability of numerical models to predict its formation in a simplified buoyancy-free environment. The current work shifts the investigation to soot-free flames, putting an emphasis on the chemiluminescence emission from electronically excited CH (CH*). This radical species is of significant interest in combustion studies: it has been shown that the CH* spatial distribution is indicative of the flame front position and, given the relatively simple diagnostic involved with its measurement, several works have been done trying to understand the ability of CH* chemiluminescence to predict the total and local flame heat release rate. In this work, a subset of the SLICE nitrogen-diluted methane flames has been considered, and the effect of fuel and coflow velocity on CH* concentration is discussed and compared with both normal gravity results and numerical simulations. Experimentally, the spectral characterization of the DSLR color camera used to acquire the flame images allowed the signal collected by the blue channel to be considered representative of the CH* emission centered around 431 nm. Due to the axisymmetric flame structure, an Abel deconvolution of the line-of-sight chemiluminescence was used to obtain the radial intensity profile and, thanks to an absolute light intensity calibration, a quantification of the CH* concentration was possible. Results show that, in microgravity, the maximum flame CH* concentration increases with the coflow velocity, but it is weakly dependent on the fuel velocity; normal gravity flames, if not lifted, tend to follow the same trend, albeit with different peak concentrations. Comparisons with numerical simulations display reasonably good agreement between measured and computed flame lengths and radii, and it is shown that the integrated CH* emission scales proportionally to the computed total heat release rate; the two-dimensional CH* spatial distribution, however, does not appear to be a good marker for the local heat release rate.

microgravity↗

High Ice Water Concentrations in the 19 August 2015 Coastal Mesoconvective System

During August 2015, NASA's DC-8 research aircraft was flown into High Ice Water Content (HIWC) events as part of a three-week campaign to collect airborne radar data and to obtain measurements from microphysical probes. Goals for this flight campaign included improved characterization of HIWC events, especially from an airborne radar perspective. This paper focuses on one of the flight days, in which a coastal mesoscale convective system (MCS) was investigated for HIWC conditions. The system appears to have been maintained by bands of convection flowing in from the Gulf of Mexico. These convective bands were capped by a large cloud canopy, which masks the underlying structure if viewed from an infrared sensing satellite. The DC-8 was equipped with an IsoKinetic Probe that measured ice concentrations of up to 2.3 g m(exp -3) within the cloud canopy of this system. Sustained measurements of ice crystals with concentrations exceeding 1 g m(exp -3) were encountered for up to ten minutes of flight time. Airborne Radar reflectivity factors were found to be weak within these regions of high ice water concentrations, suggesting that Radar detection of HIWC would be a challenging endeavor. This case is then investigated using a three-dimensional numerical cloud model. Profiles of ice water concentrations and radar reflectivity factor demonstrate similar magnitudes and scales between the flight measurements and model simulation. Also discussed are recent modifications to the numerical model's ice-microphysics that are based on measurements during the flight campaign. The numerical model and its updated ice-microphysics are further validated with a simulation of a well-known case of a supercell hailstorm measured during the Cooperative Convective Precipitation Experiment. Differences in HIWC between the continental supercell and the coastal MCS are discussed.

Proctor, Fred H.↗

Space PV Concentrators for Outer Planet and Near-Sun Missions, Using Ultra-Light Fresnel Lenses Made with Vanishing Tools

At the past four PVSCs [1-4], our team has presented recent advances in our space photovoltaic concentrator technology. In the past year, under a NASA-funded Small Business Innovation Research (SBIR) program, our team has made additional progress in the development of space photovoltaic concentrators for outer planet and near-sun missions. One noteworthy innovation is in the scalable method of producing the ultra-light Fresnel lenses which provide the optical concentration of sunlight for both point-focus and line-focus concentrators. The new method uses "vanishing" lens molding tools. The paper will present the latest advances in this technology.

O'Neill, Mark↗

Implementation Concept of Operation for a Multi-Purpose Cassegrain Solar Concentrator, Micro-Spectrometers, and Electrostatic Neutralizers to Enable In Situ Construction Activities plus Lunar, Planetary, and Deep Space Science Exploration on the Moon

The ability to utilize regolith would support human missions to the Moon and Mars by both stabilizing the surface as well as the use of indigenous resources. Precision landing requirements include surface stabilization to prevent damage or contamination due to regolith projectiles as a result of plume interaction with regolith. The use of indigenous resources rather than hauling materials from Earth appears to be economically a palatable option by converting indigenous resources to usable products. However, such activities have new technical challenges to overcome the issues related to lunar environmental conditions, a wide range of temperature fluctuation, extremely high vacuum, and electrostatically charged fine regolith dusts. For both the regolith sintering and extraction of resources onsite, a Cassegrain solar concentrator was studied for not only sintering lunar regolith into a hardened stabilized surface, but also other multiple applications. This report illustrates a Cassegrain solar concentrator that has multi-functional capabilities for space missions. Proper design and implementation of high-performance lightweight composite materials for the primary mirror of the Cassegrain concentrator can offer multiple capabilities to be performed on the Moon. The multiple applications studied with Cassegrain concentrators are (1) Solar sintering for landing pad and habitats, (2) Harvest of volatiles: H2O, O2, H2, and He-3, (3) Space antenna for telemetry and telecommunication, and (4) Space telescope with 20-meter aperture that exceeds the space telescopes to date in terms of the State-of-Art (SOA) in resolution and aperture diameter. In this study, a key emphasis was placed on the NASA Langley-developed boron nitride nanotube (BNNT) nanocomposite technology which is ideal for the segmented primary mirror structure of the Cassegrain system because it promises a very low coefficient of thermal expansion (CTE) and negligible Poisson ratio. Also, BNNT nanocomposites offer several noticeable benefits, such as light weight, radiation shielding capability, and mechanical strength for structural applications. Additionally, the NASA Langley-developed bullet-like micro-spectrometer and electrostatic power generator were reviewed for mineral mapping applications and electrostatic power generation and dust mitigation from electrostatically charged regolith.

landing pad↗

Retrieving Particulate Matter Concentrations over the Contiguous United States Using CALIOP Observations

Using twelve years (2007-2018) of NASA Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) near-surface 532 nm aerosol extinction retrievals, multi-year mean and trends of particulate matter (PM) concentrations are derived over the contiguous United States (CONUS). Different from past studies that use column integrated aerosol optical thickness, here only near-surface CALIOP aerosol extinction is used for deriving near-surface PM with aerodynamic diameters less than 2.5 µm (PM2.5) concentrations using an innovative, bulk-mass-modeling-based method. Compared against ground based PM2.5 measurements from the U.S. Environmental Protection Agency (EPA), an encouraging relationship between CALIOP-derived PM2.5 and EPA-observed PM2.5 (Deming slope = 0.89; RMSE = 3.42 µg/m3; mean bias = -1.00 µg/m3) is found using combined daytime/nighttime CALIOP data. Also, comparable trends in PM2.5 concentrations from the EPA and daytime and nighttime CALIOP data are found for most of the eastern CONUS and imply that air quality is generally improving over this region for the study period. Over the western CONUS, a seasonal analysis reveals that PM2.5 trends are positive during the more active wildfire season (June through November) but negative for other months. This study suggests that lidar data show promise in their use for obtaining PM2.5 estimates and provides motivation to further explore aerosol extinction-based PM concentration retrievals in anticipation of future space-based lidar missions.

CALIOP↗

Comparing Analysis of Hydrogen Concentration in Astromaterials Nominally Anhydrous Minerals by Multiple SIMS

Secondary Ion Mass Spectrometry (SIMS) is utilized to determine hydrogen (H) concentration in astromaterials nominally anhydrous minerals (NAMs) and their inclusions [e.g., 1]. This data is interpreted to refine the volatile history of planetary bodies. Four instruments are being used to compare H concentration analysis: a large geometry SIMS (The University of Hawaiʻi Cameca IMS 1280), a compact SIMS (Arizona State University (ASU) Cameca IMS 6f), and two Cameca NanoSIMS 50L at ASU and NASA-Johnson Space Center (JSC). Results on the first three instruments are available. Although fundamentally similar, SIMS instruments and their modifications [2] may produce different values or pose advantages for H analysis, especially for shocked samples that are susceptible to contamination filling their fractures. New data from the IMS 1280 is reported, using its microchannel plate (MCP) to image high H signals in grain fractures during pre-sputtering to avoid them as much as possible. Between fractures, 16 OH/ 30 Si was measured with a Cs + 4 nA primary beam, 30 micron spot size, and central ~5x5 micron collection area. First order comparison of H concentration (reported in ppm H 2 O) is achieved on a terrestrial gem quality clinopyroxene (SLP114, 162±12 ppm H 2 O [3]), with 157±7 and 215±40 ppm H 2 O by the IMS 1280 and 6f respectively. SIMS comparison is then extended to analysis of two Martian shergottites: RBT 04262 and NWA 5789. Due to a dense fracture network (< 20 micron) in RBT 04262, only one clinopyroxene hosted glassy inclusion was analyzed (n=6, ≤1 ppm H 2 O), while six olivine grains in NWA 5789 (n=12, ≤ 2 ppm H 2 O) (1s ±0.21) were analyzed. Higher concentrations were obtained for RBT 04262 olivine by the ASU NanoSIMS 50L (up to 350 ppm H 2 O [4]), and IMS 6f (300+ ppm H 2 O, [5]), for which contamination in fractures could not be avoided. Work on the JSC NanoSIMS 50L will further develop the SIMS comparison.

J.-M. Dudley↗

Prediction of Concentrated Vortex Aerodynamics: Current CFD Capability Survey

Concentrated vortex flows contribute to the aerodynamic performance of aircraft at elevated load conditions. For military interests, the vortex flows are exploited at maneuver conditions of combat aircraft and missiles. For transport interests, the vortex flows are exploited at takeoff and landing conditions as well as at select transonic conditions. Aircraft applications of these vortex flows are reviewed with a historical perspective followed by a discussion of the underlying physics of a concentrated vortex flow. A hierarchy of computational fluid dynamics simulation technology is then presented followed by findings from a capability survey for predicting concentrated vortex flows with computational fluid dynamics. Results are focused on military and civil aircraft; only limited results are included for missiles. Opportunities for predictive capability advancement are then reported with comments related to digital transformation interests. A hierarchical approach that merges a physics-based perspective of the concentrated vortex flows with a systems engineering viewpoint of the air vehicle is also used to frame much of the discussion.

vortex flow↗

Particle Deformation and Concentration Polarization in Electroosmotic Transport of Hydrogels through Pores

In this article, we report detection of deformable, hydrogel particles by the resistive-pulse technique using single pores in a polymer film. The hydrogels pass through the pores by electroosmosis and cause formation of a characteristic shape of resistive pulses indicating the particles underwent dehydration and deformation. These effects were explained via a non-homogeneous pressure distribution along the pore axis modeled by the coupled Poisson-Nernst-Planck and Navier Stokes equations. The local pressure drops are induced by the electroosmotic fluid flow. Our experiments also revealed the importance of concentration polarization in the detection of hydrogels. Due to the negative charges as well as branched, low density structure of the hydrogel particles, concentration of ions in the particles is significantly higher than in the bulk. As a result, when electric field is applied across the membrane, a depletion zone can be created in the vicinity of the particle observed as a transient drop of the current. Our experiments using pores with openings between 200 and 1600 nm indicated the concentration polarization dominated the hydrogels detection for pores wider than 450 nm. The results are of importance for all studies that involve transport of molecules, particles and cells through pores with charged walls. The developed inhomogeneous pressure distribution can potentially influence the shape of the transported species. The concentration polarization changes the interpretation of the resistive pulses; the observed current change does not necessarily reflect only the particle size but also the size of the depletion zone that is formed in the particle vicinity.

Vlassiouk, Ivan V↗

Focusing particle concentrator with application to ultrafine particles

Technology is presented for the high efficiency concentration of fine and ultrafine airborne particles into a small fraction of the sampled airflow by condensational enlargement, aerodynamic focusing and flow separation. A nozzle concentrator structure including an acceleration nozzle with a flow extraction structure may be coupled to a containment vessel. The containment vessel may include a water condensation growth tube to facilitate the concentration of ultrafine particles. The containment vessel may further include a separate carrier flow introduced at the center of the sampled flow, upstream of the acceleration nozzle of the nozzle concentrator to facilitate the separation of particle and vapor constituents.

47 OTHER INSTRUMENTATION↗

Solar concentrator with integrated tracking and light delivery system with summation

A solar light distribution system includes a solar light concentrator that is affixed externally to a light transfer tube. Solar light waves are processed by the concentrator into a collimated beam of light, which is then transferred through a light receiving port and into the light transfer tube. A reflector redirects the collimated beam of light through the tube to a light distribution port. The interior surface of the light transfer tube is highly reflective so that the light transfers through the tube with minimal losses. An interchangeable luminaire is attached to the light distribution port and provides light inside of a structure. A sun tracking device rotates the concentrator and the light transfer tube to optimize the receiving of solar light by the concentrator throughout the day. The system provides interior lighting that uses only renewable energy sources, and releases no carbon dioxide emissions into the atmosphere.

14 SOLAR ENERGY↗

Solar concentrator with integrated tracking and light delivery system with collimation

A solar light distribution system includes a solar light concentrator that is affixed externally to a light transfer tube. Solar light waves are processed by the concentrator into a collimated beam of light, which is then transferred through a light receiving port and into the light transfer tube. A reflector directs the collimated beam of light through the tube to a light distribution port. The interior surface of the light transfer tube is highly reflective so that the light transfers through the tube with minimal losses. An interchangeable luminaire is attached to the light distribution port and distributes light inside of a structure. A sun tracking device rotates the concentrator and the light transfer tube to optimize the receiving of solar light by the concentrator throughout the day. The system provides interior lighting, uses only renewable energy sources, and releases no carbon dioxide emissions into the atmosphere.

14 SOLAR ENERGY↗

Droplet Number Concentration Value Added Product

Cloud droplet number concentration is an important factor in understanding aerosol-cloud interactions. As aerosol concentration increases, it is expected that droplet number concentration (Nd) will increase and droplet size will decrease, for a given liquid water path. This will greatly affect cloud albedo as smaller droplets reflect more shortwave radiation; however, the magnitude and variability of these processes under different environmental conditions is still uncertain.McComiskey et al. (2009) have implemented a method, based onBoers and Mitchell (1994), for calculating Nd from ground-based remote sensing measurements of optical depth and liquid water path. They show that the magnitude of the aerosol-cloud interactions (ACI) varies with a range of factors, including the relative value of the cloud liquid water path (LWP), the aerosol size distribution, and the cloud updraft velocity. Estimates of Nd under a range of cloud types and conditions and at a variety of sites are needed to further quantify the impacts of aerosol cloud interactions. In order to provide data sets for studying aerosol-cloud interactions, the McComiskey et al. (2009) method was implemented as the Droplet Number Concentration (NDROP) value-added product (VAP).

Chitra Sivaraman, PNNL↗

Luminescent solar concentrators and related methods of manufacturing

Luminescent solar concentrators in accordance with various embodiments of the invention can be designed to minimize photon thermalization losses and incomplete light trapping using various components and techniques. Cadmium selenide core, cadmium sulfide shell (CdSe/CdS) quantum dot (“QD”) technology can be implemented in such devices to allow for near-unity QDs and sufficiently large Stokes shifts. Many embodiments of the invention include a luminescent solar concentrator that incorporates CdSe/CdS quantum dot luminophores. In further embodiments, anisotropic luminophore emission can be implemented through metasurface/plasmonic antenna coupling. In several embodiments, red-shifted luminophores are implemented. Additionally, top and bottom spectrally-selective filters, such as but not limited to selectively-reflective metasurface mirrors and polymeric stack filters, can be implemented to enhance the photon collection efficiency. In some embodiments, luminescent solar concentrator component is optically connected in tandem with a planar Si subcell, forming a micro-optical tandem luminescent solar concentrator.

Needell, David R.↗

Complex concentrated alloys: materials, methods, and techniques for manufacture

Complex concentrated alloys include five or more elements, at least one of which is ruthenium. Example complex concentrated alloys can include nickel and chromium, iron, ruthenium, molybdenum, and/or tungsten. Example complex concentrated alloys have single phase microstructure of face centered cubic (FCC) and can be homogenous. Example complex concentrated alloys can exhibit improved corrosion resistance.

Lu, Pin↗

Evaluation of Background Concentrations of Contaminants in an Unusual Desert Arroyo Near a Uranium Mill Tailings Disposal Cell - 12260

The U.S. Department of Energy (DOE) Office of Legacy Management (LM) manages 27 sites that have groundwater containing uranium concentrations above background levels. The distal portions of the plumes merge into background groundwater that can have 50 μg/L or more uranium. Distinguishing background from site-related uranium is often problematic, but it is critical to determining if remediation is warranted, establishing appropriate remediation goals, and evaluating disposal cell performance. In particular, groundwater at disposal cells located on the upper Cretaceous Mancos Shale may have relatively high background concentrations of uranium. Elevated concentrations of nitrate, selenium, and sulfate accompany the uranium. LM used geologic analogs and uranium isotopic signatures to distinguish background groundwater from groundwater contaminated by a former uranium processing site. The same suite of contaminants is present in groundwater near former uranium processing sites and in groundwater seeps emanating from the Mancos Shale over a broad area. The concentrations of these contaminants in Many Devils Wash, located near LM's Shiprock disposal cell, are similar to those in samples collected from many Mancos seeps, including two analog sites that are 8 to 11 km from the disposal cell. Samples collected from Many Devils Wash and the analog sites have high AR values (about 2.0)-in contrast, groundwater samples collected near the tailings disposal cell have AR values near 1.0. These chemical signatures raise questions about the origin of the contamination seeping into Many Devils Wash. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pilot Plant Test of Removal of Co-60 and Cs-137 from the Evaporator Concentrates of Forsmark unit 3 - 17158

A pilot plant test has been conducted to treat evaporator concentrates at Forsmark BWR NPP unit 3 in Sweden using Fortum's selective ion exchanger technology. The concentrate contains an array of radionuclides of which C-60 and Cs-137 are radiologically the most important ones. Concentrate also contained a high salt content ∼ 20 g/l and high organic carbon loading ∼ 1 g/l The pilot system consisted of pre-treatment (mechanical filters, activated carbon, UV oxidation) and Cs and Co selective ion exchangers. CsTreat ion exchanger was very effective in removing Cs from the evaporator concentrate: {sup 137}Cs activity was lowered from the initial value 280 MBq/m{sup 3} to below detection limit 550 Bq/m{sup 3}. Removing Co was more complicated: results suggest that Co is bound to organic chelating compounds, thus fairly compete oxidation of organic carbon was required in order to achieve good ion exchange results. Finally, after total organic carbon (TOC) was treated to below 50 ppm, {sup 60}Co activity was lowered from the initial value of 57 MBq/m{sup 3} to 2.7 kBq/m{sup 3}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RO concentrated water treatment equipment for risk reduction of contaminated water stored in tank in Fukushima NPS - 16655

At the Fukushima Daiichi Nuclear Power Station (NPS) site, concentrated waste water was stored in tanks, awaiting treatment to remove radionuclides using various multi-nuclide removal systems. To accelerate the treatment for risk reductions of radiation dose and tank leakage, we constructed reverse-osmosis (RO) concentrated water treatment equipment. The equipment consists of filters and five adsorbent vessels containing Cs-Sr simultaneous adsorbents with the removal ability of Sr being 1/1000(max) to 1/100(min), and the overall treatment capacity of 500 to 900 m{sup 3}/day. We developed a simulation code to calculate the Sr concentration of outlet water for each vessel in order to evaluate the bed life of the media. The simulation code makes it possible to plan when to change media in the vessels during the equipment operation. The successful treatment of concentrated waste water was conducted using the equipment from January to May 2015. Total amount of water treated was 82,194 m{sup 3}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗