Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Tomographic Hard X-ray Phase Contrast Micro- and Nano-imaging at TOMCAT

This article illustrates the phase contrast instrumentation installed at the Tomographic Microscopy and Coherent Radiology beamline (TOMCAT) of the Swiss Light Source. Our experimental framework has been designed to extract phase information at spatial resolutions covering three orders of magnitude. For moderate (5-10 microns) resolutions we implemented a two-gratings interferometer, operated at energies between 14 and 40 keV. For high resolution (1-5 microns) we obtain phase information thanks to a modified transport of intensity approach. For very high-resolutions (0.1-0.5 microns) we developed a broadband hard X-ray full-field microscope operated in Zernike-phase contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electric Field Reconstruction in the Image Plane of a High-Contrast Coronagraph Using a Set of Pinholes around the Lyot Plane

In a setup similar to the self coherent camera, we have added a set of pinholes in the diffraction ring of the Lyot plane in a high-contrast stellar Lyot coronagraph. We describe a novel complex electric field reconstruction from image plane intensity measurements consisting of light in the coronagraph's dark hole interfering with light from the pinholes. The image plane field is modified by letting light through one pinhole at a time. In addition to estimation of the field at the science camera, this method allows for self-calibration of the probes by letting light through the pinholes in various permutations while blocking the main Lyot opening. We present results of estimation and calibration from the High Contrast Imaging Testbed along with a comparison to the pair-wise deformable mirror diversity based estimation technique. Tests are carried out in narrow-band light and over a composite 10% bandpass.

coronagraphs↗

Efficient prediction of attosecond two-colour pulses from an X-ray free-electron laser with machine learning

Abstract X-ray free-electron lasers are sources of coherent, high-intensity X-rays with numerous applications in ultra-fast measurements and dynamic structural imaging. Due to the stochastic nature of the self-amplified spontaneous emission process and the difficulty in controlling injection of electrons, output pulses exhibit significant noise and limited temporal coherence. Standard measurement techniques used for characterizing two-coloured X-ray pulses are challenging, as they are either invasive or diagnostically expensive. In this work, we employ machine learning methods such as neural networks and decision trees to predict the central photon energies of pairs of attosecond fundamental and second harmonic pulses using parameters that are easily recorded at the high-repetition rate of a single shot. Using real experimental data, we apply a detailed feature analysis on the input parameters while optimizing the training time of the machine learning methods. Our predictive models are able to make predictions of central photon energy for one of the pulses without measuring the other pulse, thereby leveraging the use of the spectrometer without having to extend its detection window. We anticipate applications in X-ray spectroscopy using XFELs, such as in time-resolved X-ray absorption and photoemission spectroscopy, where improved measurement of input spectra will lead to better experimental outcomes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging properties and its improvements of scanning/imaging x-ray microscope

A scanning / imaging X-ray microscope (SIXM) system has been developed at SPring-8. The SIXM consists of a scanning X-ray microscope with a one-dimensional (1D) X-ray focusing device and an imaging (full-field) X-ray microscope with a 1D X-ray objective. The motivation of the SIXM system is to realize a quantitative and highly-sensitive multimodal 3D X-ray tomography by taking advantages of both the scanning X-ray microscope using multi-pixel detector and the imaging X-ray microscope. Data acquisition process of a 2D image is completely different between in the horizontal direction and in the vertical direction; a 1D signal is obtained with the linear-scanning while the other dimensional signal is obtained with the imaging optics. Such condition have caused a serious problem on the imaging properties that the imaging quality in the vertical direction has been much worse than that in the horizontal direction. In this paper, two approaches to solve this problem will be presented. One is introducing a Fourier transform method for phase retrieval from one phase derivative image, and the other to develop and employ a 1D diffuser to produce an asymmetrical coherent illumination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cloud Overlapping Detection Algorithm Using Solar and IR Wavelengths With GOSE Data Over ARM/SGP Site

One of the most perplexing problems in satellite cloud remote sensing is the overlapping of cloud layers. Although most techniques assume a 1-layer cloud system in a given retrieval of cloud properties, many observations are affected by radiation from more than one cloud layer. As such, cloud overlap can cause errors in the retrieval of many properties including cloud height, optical depth, phase, and particle size. A variety of methods have been developed to identify overlapped clouds in a given satellite imager pixel. Baum el al. (1995) used CO2 slicing and a spatial coherence method to demonstrate a possible analysis method for nighttime detection of multilayered clouds. Jin and Rossow (1997) also used a multispectral CO2 slicing technique for a global analysis of overlapped cloud amount. Lin et al. (1999) used a combination infrared, visible, and microwave data to detect overlapped clouds over water. Recently, Baum and Spinhirne (2000) proposed 1.6 and 11 microns. bispectral threshold method. While all of these methods have made progress in solving this stubborn problem, none have yet proven satisfactory for continuous and consistent monitoring of multilayer cloud systems. It is clear that detection of overlapping clouds from passive instruments such as satellite radiometers is in an immature stage of development and requires additional research. Overlapped cloud systems also affect the retrievals of cloud properties over the ARM domains (e.g., Minnis et al 1998) and hence should identified as accurately as possible. To reach this goal, it is necessary to determine which information can be exploited for detecting multilayered clouds from operational meteorological satellite data used by ARM. This paper examines the potential information available in spectral data available on the Geostationary Operational Environmental Satellite (GOES) imager and the NOAA Advanced Very High Resolution Radiometer (AVHRR) used over the ARM SGP and NSA sites to study the capability of detecting overlapping clouds

Kawamoto, Kazuaki↗

Complex Pupil Masks for Aberrated Imaging of Closely Spaced Objects

Current approach demonstrates the suppression of optical side-lobes and the contraction of the main lobe in the composite image of two object points of the optical system under the influence of defocusing effect when an asymmetric phase edges are imposed over the apodized circular aperture. The resolution of two point sources having different intensity ratio is discussed in terms of the modified Sparrow criterion, functions of the degree of coherence of the illumination, the intensity difference and the degree of asymmetric phase masking. Here we have introduced and explored the effects of focus aberration (defect-of-focus) on the two-point resolution of the optical systems. Results on the aberrated composite image of closely spaced objects with amplitude mask and asymmetric phase masks forms a significant contribution in astronomical and microscopic observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absorber height effects on SWA restrictions and 'Shadow' LER

As extreme-ultraviolet lithography (EUVL) approaches introduction at the 22-nm half-pitch node, several key aspects of absorber height effects remain unexplored. In particular, sidewall angle (SWA) restrictions based on the height of the mask absorber has not yet been clearly defined. In addition, the effects of absorber height on line-edge roughness (LER) from shadowing has not been examined. We make an initial investigation into how tight SWA constraints are and the extent to which shadow LER alters basic LER. Our approach to SWA aims to find SWA restrictions based on 10% of the total CD error budget (10% of CD). Thus, we allot the SWA budget a {+-}0.2nm tolerance for 22nm half-pitch. New with EUVL is the off-axis illumination system. One potential pitfall that must be carefully monitored is the effect of mask absorber height blocking light from reaching, and therefore, correctly detecting, the base edge position of a feature. While mask features can correctly compensate sizing to target at the wafer, the effects of this shadowing on LER have not yet been investigated. Specifically, shadow LER may exacerbate or mitigate the inherent LER on the mask. Shadowing may also cause a difference in the observed LER on the right and left side of the features. We carefully probe this issue for a range of spatial frequencies. We do rigorous aerial image modeling of mask features with a nominal SWA of 80 degrees and correctly sized to target 22nm features measured at the top, 70nm TaN absorber on a 40 bilayer ML mirror with a 2.5nm Ru cap. Simulations were on a 4X system with an ideal pupil of NA = 0.32, illumination wavelength 13.4nm at 6{sup o} off-axis, and disk source shape with partial coherence factor of {sigma} = 0.50. We first implement a defocus offset to the aerial image so that best focus lies at a nominal zero defocus value. We then calculate the depth of focus (DOF) for which the image-log-slope (ILS) delivers a contrast is greater than 50%, an arbitrary standard for a good quality photoresist to print. Using this DOF, we optimize the process window and adjust the intensity threshold from it's nominal value to a new optimal value. From this optimized intensity threshold, we calculated the aerial image CD through focus for a range of angles around the nominal SWA value. From this, we can find out how much the SWA needs to be constrained by in order to keep the {+-}10% CD error budget tolerance required. For SWA of 80 degrees, we found the nominal SWA is tightly constrained by 0.5 degrees. We repeated these calculations for other nominal values of SWA 85 and 88 degrees, and found that CD sensitivity to nominal SWA is relatively independent. In examining shadow LER, we use FDTD simulations to obtain a rigorous solution for the source intensity immediately after the patterned TaN mask absorber pattern on a 2.5nm Ru capped 40 bilayer ML mirror. The optical system was comprised of an ideal pupil map, NA = 0.32, 13.4nm light at 4{sup o} off-axis, and annular source shape with partial coherence factor of {sigma} = 0.35-0.55. We assumed a 90{sup o} SWA. For the basic 2D shape of the mask that we exactly replicated through height, we created mask LER by generating a sine wave of full amplitude 4nm, equivalent to 4nm LER, (wafer dim.), confined along it's length to precisely CD=22nm, for sine waves with spatial frequencies (full period) of 25, 50, 75, 100, 125, 150, 175, and 200nm (wafer dim.), and illuminated at both {phi}=0{sup o} (perpendicular, shadowing) and {phi}=90{sup o} (parallel, no shadowing). Results show that even off-axis illumination perpendicular to the lines and spaces gives minimal difference between the left and right LER to at most 0.1nm difference at best focus. We followed up this study by repeating the data for a mask designed with 2nm LER with similar results. A plot of the transfer functions for LER of both 2nm and 4nm compared to the contrast of simple 50% duty cycle lines and spaces shows that LER has a unique transfer function as well as a linear response to LER amplitude. In the course of our investigation of SWA, we found that the nominal angle has no effect on process window size, and neither does sensitivity on changing angle alter as a function of nominal angle. For nominal 80{sup o}, 85{sup o}, 88{sup o} SWA, the amount of angle tolerance for 0.2nm change in CD was in total 0.5{sup o}. For shadow LER, we found minimal difference between left and right LER when illuminated perpendicularly to the pattern, to at most 0.1nm LER at best focus. CTFs confirm the uniqueness and linearity of an LER transfer function as opposed to the traditional MTF, as shown in a previous study. In the future we wish to expand our work on shadow LER into the regime where the k{sub 1}-factor of the optic is stressed. In particular, 16nm lines and spaces on an NA = 0.32 optic with off-axis illumination.

36 MATERIALS SCIENCE↗

Critical aspects of nano-indentation technique in application to hardened cement paste

Several open questions related to the experimental protocol and processing of data acquired by the nano-indentation (NI) technique are investigated. The volume fractions of mechanically different phases obtained from statistical NI (SNI) analysis are shown to be different from those obtained by back-scattered electron (BSE) image analysis and X-ray diffraction (XRD) method on the same paste. Judging from transmission electron microscope (TEM) images, the representative volume element of low-density calcium-silicate hydrates (C-S-H) can be considered to be around 500 nm, whereas for high-density C-S-H it is about 100 nm. This raises the question how the appropriate penetration depth for NI experiments should be selected. Changing the maximum load from 1 mN to 5 mN, the effect of penetration depth on the experimental results is studied. As an alternative to the SNI method, a 'manual' indentation method is proposed, which combines information from BSE and atomic-force microscopy (AFM), coupled to the NI machine. The AFM allows to precisely indent a high-density C-S-H rim around unhydrated clinkers in cement paste. Yet the results from that technique still show a big scatter.

36 MATERIALS SCIENCE↗

Application of THz probe radiation in low-coherent tomographs based on spatially separated counterpropagating beams

A principle of designing a high-resolution low-coherent THz tomograph, which makes it possible to investigate media with a high spatial resolution (in the range λ{sub 0} – 2λ{sub 0}, where λ{sub 0} is the average probe wavelength) is considered. The operation principle of this tomograph implies probing a medium by radiation with a coherence length of 8λ{sub 0} and recording a hologram of a focused image of a fixed layer of this medium using spatially separated counterpropagating object and reference beams. Tomograms of the medium studied are calculated using a temporal approach based on application of the time correlation function of probe radiation. (terahertz radiation)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer Model Calibration Based on Image Warping Metrics: An Application for Sea Ice Deformation

Arctic sea ice plays an important role in the global climate. Sea ice models governed by physical equations have been used to simulate the state of the ice including characteristics such as ice thickness, concentration, and motion. More recent models also attempt to capture features such as fractures or leads in the ice. These simulated features can be partially misaligned or misshapen when compared to observational data, whether due to numerical approximation or incomplete physics. In order to make realistic forecasts and improve understanding of the underlying processes, it is necessary to calibrate the numerical model to field data. Traditional calibration methods based on generalized least-square metrics are flawed for linear features such as sea ice cracks. We develop a statistical emulation and calibration framework that accounts for feature misalignment and misshapenness, which involves optimally aligning model output with observed features using cutting-edge image registration techniques. Here, this work can also have application to other physical models which produce coherent structures.

54 ENVIRONMENTAL SCIENCES↗

Observation of quasi-coherent edge fluctuations in Ohmic plasmas on NSTX

A quasi-coherent mode with frequency f = 40 kHz is observed in Ohmic plasmas in NSTX with the gas puff imaging diagnostic (GPI). This mode is located predominantly just inside the separatrix, with a maximum fluctuation amplitude similar to that of the broadband turbulence in the same frequency range. The quasi-coherent mode has a poloidal wavelength 16 cm and a poloidal velocity 49 km/s in the electron diamagnetic direction, which are similar to the characteristics expected from a linear drift-wave like mode in the edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast nano-imaging and nano-spectroscopy

Ultrafast pump–probe nano-imaging combines scanning probe-based optical near-field microscopy with ultrafast spectroscopy to enable imaging with deep sub-wavelength spatial resolution, femtosecond temporal resolution and simultaneous spectral resolution. Ultrafast nano-imaging has gained increased attention for its ability to provide far-from-equilibrium excitation and excited-state contrast. With coherent and nonlinear probing, coupled electron, spin and lattice dynamics on elementary timescale and length scale can be resolved. Through nano-movies, ultrafast nano-imaging visualizes correlated quantum dynamics underlying the properties of solid-state materials, semiconductors, molecular electronic, photonic, photovoltaic and other functional materials. With nanometre spatial resolution, this method probes elementary dynamic processes across multiple length scales that are otherwise obscured in conventional ultrafast spectroscopy in which heterogeneities are spatially averaged. Furthermore, this Primer describes the theoretical background and experimental implementation of ultrafast nano-imaging; signal interpretation and modelling; representative examples and a perspective for the future development of the field.

Microscopy↗

Millimeter Wave Synthetic Aperture Imaging System with a Unique Rotary Scanning System

In recent years, millimeter wave imaging techniques, using synthetic aperture focusing and holographical approaches, have shown tremendous potential for nondestructive testing applications, involving materials and structures used in space vehicles, including the space shuttle external fuel tank spray on foam insulation and its acreage heat tiles. The ability of signals at millimeter wave frequencies (30 - 300 GHz) to easily penetrate inside of low loss dielectric materials, their relatively small wavelengths, and the possibility of detecting coherent (magnitude and phase) reflections make them suitable for high resolution synthetic aperture focused imaging the interior of such materials and structures. To accommodate imaging requirements, commonly a scanning system is employed that provides for a raster scan of the desired structure. However, most such scanners, although simple in design and construction, are inherently slow primarily due to the need to stop and start at the beginning and end of each scan line. To this end, a millimeter wave synthetic aperture focusing system including a custom-designed transceiver operating at 35 - 45 GHz (Q-band) and unique and complex rotary scanner was designed and developed. The rotary scanner is capable of scanning an area with approximately 80 cm in diameter in less than 10 minutes at step sizes of 3 mm and smaller. The transceiver is capable of producing accurate magnitude and phase of reflected signal from the structure under test. Finally, a synthetic aperture focusing algorithm was developed that translates this rotary-obtained magnitude and phase into a synthetic aperture focusing image of inspected structures. This paper presents the design of the transceiver and the rotary scanning system along with showing several images obtained with this system from various complicated structures.

Ghasr, M. T.↗

Megahertz-rate shock-wave distortion cancellation via phase conjugate digital in-line holography

Abstract Holography is a powerful tool for three-dimensional imaging. However, in explosive, supersonic, hypersonic, cavitating, or ionizing environments, shock-waves and density gradients impart phase distortions that obscure objects in the field-of-view. Capturing time-resolved information in these environments also requires ultra-high-speed acquisition. To reduce phase distortions and increase imaging rates, we introduce an ultra-high-speed phase conjugate digital in-line holography (PCDIH) technique. In this concept, a coherent beam passes through the shock-wave distortion, reflects off a phase conjugate mirror, and propagates back through the shock-wave, thereby minimizing imaging distortions from phase delays. By implementing the method using a pulse-burst laser setup at up to 5 million-frames-per-second, time-resolved holograms of ultra-fast events are now possible. This technique is applied for holographic imaging through laser-spark plasma-generated shock-waves and to enable three-dimensional tracking of explosively generated hypersonic fragments. Simulations further advance our understanding of physical processes and experiments demonstrate ultra-high-speed PCDIH techniques for capturing dynamics.

Science & Technology - Other Topics↗

Untangling the contributions of image charge and laser profile for optimal photoemission of high-brightness electron beams

Using our model for the simulation of photoemission of high brightness electron beams, we investigate the virtual cathode physics and the limits to spatio-temporal and spectroscopic resolution originating from the image charge on the surface and from the profile of the exciting laser pulse. By contrasting the effect of varying surface properties (leading to expanding or pinned image charge), laser profiles (Gaussian, uniform, and elliptical), and aspect ratios (pancake- and cigar-like) under different extraction field strengths and numbers of generated electrons, we quantify the effect of these experimental parameters on macroscopic pulse properties such as emittance, brightness (4D and 6D), coherence length, and energy spread. Based on our results, we outline optimal conditions of pulse generation for ultrafast electron microscope systems that take into account constraints on the number of generated electrons and on the required time resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comprehensive Northern Hemisphere Particle Microphysics Data Set From the Precipitation Imaging Package

Microphysical observations of precipitating particles are critical data sources for numerical weather prediction models and remote sensing retrieval algorithms. However, obtaining coherent data sets of particle microphysics is challenging as they are often unindexed, distributed across disparate institutions, and have not undergone a uniform quality control process. This work introduces a unified, comprehensive Northern Hemisphere particle microphysical data set from the National Aeronautics and Space Administration precipitation imaging package (PIP), accessible in a standardized data format and stored in a centralized, public repository. Data is collected from 10 measurement sites spanning 34° latitude (37°N–71°N) over 10 years (2014–2023), which comprise a set of 1,070,000 precipitating minutes. The provided data set includes measurements of a suite of microphysical attributes for both rain and snow, including distributions of particle size, vertical velocity, and effective density, along with higher-order products including an approximation of volume-weighted equivalent particle densities, liquid equivalent snowfall, and rainfall rate estimates. The data underwent a rigorous standardization and quality assurance process to filter out erroneous observations to produce a self-describing, scalable, and achievable data set. Case study analyses demonstrate the capabilities of the data set in identifying physical processes like precipitation phase-changes at high temporal resolution. Bulk precipitation characteristics from a multi-site intercomparison also highlight distinct microphysical properties unique to each location. This curated PIP data set is a robust database of high-quality particle microphysical observations for constraining future precipitation retrieval algorithms, and offers new insights toward better understanding regional and seasonal differences in bulk precipitation characteristics.

54 ENVIRONMENTAL SCIENCES↗