Method and Apparatus for the Portable Identification Of Material Thickness And Defects Along Uneven Surfaces Using Spatially Controlled Heat Application

A method and apparatus for testing a material such as the water-wall tubes in boilers includes the use of a portable thermal line heater having radiation shields to control the amount of thermal radiation that reaches a thermal imager. A procedure corrects for variations in the initial temperature of the material being inspected. A method of calibrating the testing device to determine an equation relating thickness of the material to temperatures created by the thermal line heater uses empirical data derived from tests performed on test specimens for each material type, geometry, density, specific heat, speed at which the line heater is moved across the material and heat intensity.

Reilly, Thomas L.↗

Measurements of Nitrogen Dioxide Total Column Amounts using a Brewer Double Spectrophotometer in Direct Sun Mode

NO2 column amounts were measured for the past 2 years at Goddard Space Flight Center, Greenbelt, Maryland, using a Brewer spectrometer in direct Sun mode. A new bootstrap method to calibrate the instrument is introduced and described. This technique selects the cleanest days from the database to obtain the solar reference spectrum. The main advantage for direct Sun measurements is that the conversion uncertainty from slant column to vertical column is negligible compared to the standard scattered light observations where it is typically on the order of 100% (2sigma) at polluted sites. The total 2sigma errors of the direct Sun retrieved column amounts decrease with solar zenith angle and are estimated at 0.2 to 0.6 Dobson units (DU, 1 DU approx. equal to 2.7 10(exp 16) molecules cm(exp -2)), which is more accurate than scattered light measurements for high NO2 amounts. Measured NO2 column amounts, ranging from 0 to 3 DU with a mean of 0.7 DU, show a pronounced daily course and a strong variability from day to day. The NO2 concentration typically increases from sunrise to noon. In the afternoon it decreases in summer and stays constant in winter. As expected from the anthropogenic nature of its source, NO2 amounts on weekends are significantly reduced. The measurements were compared to satellite retrievals from Scanning Image Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY). Satellite data give the same average NO2 column and show a seasonal cycle that is similar to the ground data in the afternoon. We show that NO2 must be considered when retrieving aerosol absorption properties, especially for situations with low aerosol optical depth.

Cede, Alexander↗

Robust incoherent fiber optic bundle decoder

Apparatus and method for calibrating an incoherent fiber optic bundle for use in transmitting visual or infrared coherent images. The apparatus includes a computer, a computer video monitor, an objective lens adjacent to the input end of the bundle, a second lens adjacent the output end of the bundle, and a CCD camera. The camera transmits video data to the monitor to produce an illuminated fiber optic image. The coordinates for the center of each fiber is found through an imaging process and the output fibers coordinates are related to the input fiber coordinates and processed in the computer to produce a mapping lookup-table (LUT) unique to the specific fiber bundle. Remapping of the LUT due to changes in the lens focus, CCD camera, or the addition of an infrared filter is accomplished by a software utility in the computer.

Roberts, Hilary E.↗

CALIPSO Observations of Stratospheric Aerosols: A Preliminary Assessment

We have examined the 532-nm aerosol backscatter coefficient measurements by the Cloud- Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) for their use in the observation of stratospheric aerosol. CALIPSO makes observations that span from 82 S to 82 N each day and, for each profile, backscatter coefficient values reported up to approx. 40 km. The possibility of using CALIPSO for stratospheric aerosol observations is demonstrated by the clear observation of the 20 May 2006 eruption of Montserrat in the earliest CALIPSO data in early June as well as by observations showing the 7 October 2006 eruption of Tavurvur (Rabaul). However, the very low aerosol loading within the stratosphere makes routine observations of the stratospheric aerosol far more difficult than relatively dense volcanic plumes. Nonetheless, we found that averaging a complete days worth of nighttime only data into 5-deg latitude by 1-km vertical bins reveals a stratospheric aerosol data centered near an altitude of 20 km, the clean wintertime polar vortices, and a small maximum in the lower tropical stratosphere. However, the derived values are clearly too small and often negative in much of the stratosphere. The data can be significantly improved by increasing the measured backscatter (molecular and aerosol) by approximately 5% suggesting that the current method of calibrating to a pure molecular atmosphere at 30 km is most likely the source of the low values.

Thomason, Larry W.↗

Measurement of the Dielectric Constant of Seawater at L-Band: Techniques and Measurements

Satellite instruments, that will monitor salinity from space in the near future, require an accurate relationship between salinity/temperature and seawater dielectric constant. This paper will review measurements that were made of the dielectric constant of seawater during the past several years. The objective of the measurements is to determine the dependence of the dielectric constant of seawater on salinity and on temperature, more accurately than in the past. by taking advantage of modem instrumentation. The measurements of seawater permittivity have been performed as a function of salinity and temperature using a transmission resonant cavity technique. The measurements have been made in the salinity range of 10 to 38 psu and in the temperature range of IOU C to 35 C. These results will be useful in algorithm development for sensor systems such as SMOS and Aquarius. The measurement system consists of a brass microwave cavity that is resonant at 1.413 GHz. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The diameter of the tube has been made very small so that the amount of seawater introduced in the cavity is small - thus maintaining the sensitivity of the measurements and allowing the use of perturbation theory predicting the seawater permittivity. The change in resonant frequency and the change in cavity Q can be used to determine the real and imaginary pare of the dielectric constant of seawater introduced into the slender tube. The microwave measurements are made by an HPS722D network analyzer. The cavity has been immersed in a u~ateriethylene-glycol bath which is connected to a Lauda circulator. The circulator keeps the brass cavity at a temperature constant to within 0.01 degrees. The system is automated using a Visual Basic program to control the analyzer and to collect the data. The results of the dielectric constant measurements of seawater will be presented. The measurement results will be compared with permittivity values generated from the Kline and Swift relationship. Two methods of calibration will be discussed, The errors that each technique introduces into the measurement resulls will be reviewed. Temperature stability, frequency drift and the effect of increasing cavity transmission loss on the unloaded cavity Q will also be discussed.

Lang, R.↗

Method and Apparatus for Accurately Calibrating a Spectrometer

A calibration assembly for a spectrometer is provided. The assembly includes a spectrometer having n detector elements, where each detector element is assigned a predetermined wavelength value. A first source emitting first radiation is used to calibrate the spectrometer. A device is placed in the path of the first radiation to split the first radiation into a first beam and a second beam. The assembly is configured so that one of the first and second beams travels a path-difference distance longer than the other of the first and second beams. An output signal is generated by the spectrometer when the first and second beams enter the spectrometer. The assembly includes a controller operable for processing the output signal and adapted to calculate correction factors for the respective predetermined wavelength values assigned to each detector element.

Youngquist, Robert C.↗

Pyrometer

A non-contact pyrometer and method for calibrating the same are provided. The pyrometer includes a radiation sensor configured to measure at least a portion of a radiance signal emitted from a target medium and output a voltage that is a function of an average of the absorbed radiance signal, and an optical window disposed proximate the radiation sensor and configured to control a wavelength range of the radiance signal that reaches the radiation sensor. The pyrometer may further include a reflective enclosure configured to receive the target medium therein, wherein the radiation sensor and the optical window are disposed within the reflective enclosure, an amplifier in communication with an output of the radiation sensor, and a data acquisition system in communication with an output of the amplifier.

Quince, Asia N.↗

Detection of Operator Performance Breakdown as an Automation Triggering Mechanism

Performance breakdown (PB) has been anecdotally described as a state where the human operator "loses control of context" and "cannot maintain required task performance." Preventing such a decline in performance is critical to assure the safety and reliability of human-integrated systems, and therefore PB could be useful as a point at which automation can be applied to support human performance. However, PB has never been scientifically defined or empirically demonstrated. Moreover, there is no validated objective way of detecting such a state or the transition to that state. The purpose of this work is: 1) to empirically demonstrate a PB state, and 2) to develop an objective way of detecting such a state. This paper defines PB and proposes an objective method for its detection. A human-in-the-loop study was conducted: 1) to demonstrate PB by increasing workload until the subject reported being in a state of PB, and 2) to identify possible parameters of a detection method for objectively identifying the subjectively-reported PB point, and 3) to determine if the parameters are idiosyncratic to an individual/context or are more generally applicable. In the experiment, fifteen participants were asked to manage three concurrent tasks (one primary and two secondary) for 18 minutes. The difficulty of the primary task was manipulated over time to induce PB while the difficulty of the secondary tasks remained static. The participants' task performance data was collected. Three hypotheses were constructed: 1) increasing workload will induce subjectively-identified PB, 2) there exists criteria that identifies the threshold parameters that best matches the subjectively-identified PB point, and 3) the criteria for choosing the threshold parameters is consistent across individuals. The results show that increasing workload can induce subjectively-identified PB, although it might not be generalizable-only 12 out of 15 participants declared PB. The PB detection method based on signal detection analysis was applied to the performance data and the results showed that PB can be identified using the method, particularly when the values of the parameters for the detection method were calibrated individually.

multi-task environment↗

The Effect of Thin Film Adhesives on Mode I Interlaminar Fracture Toughness in Carbon Fiber Composites with Shape Memory Alloy Inserts

Shape Memory Alloy (SMA) was placed within Polymer Matrix Composite (PMC) panels alongside film adhesives to examine bonding. Double cantilever beam (DCB) testing was performed using ASTM D5528. C-scanning was performed before testing, modal acoustic emissions (MAE) were monitored during testing, and microscopy performed post-test. Data was analyzed using modified beam theory (MBT), compliance calibration (CC) and modified compliance calibration (MCC) methods. Fracture toughness for control specimens was higher than previously reported due to fiber-bridging. Specimens with SMAs and adhesives stabilized crack propagation. Results revealed SMA-bridging; a phenomenon mimicking fiber-bridging which increased the load and fracture toughness of SMA specimens.

Derek J Quade↗

MODIS and VIIRS Calibration History and Future Outlook

The MODIS is a key instrument for NASA’s EOS program, currently operated onboard the Terra and Aqua spacecraft launched in 1999 and 2002, respectively. The VIIRS is a MODIS follow-on instrument for the JPSS program. Adding to the ones operated onboard the S-NPP and NOAA-20 satellites launched in 2011 and 2017, respectively, three nearly identical VIIRS instruments will also be launched. This will enable the data records from MODIS and VIIRS to be extended beyond 2040. In addition to various applications and scientific studies of the Earth’s system, long-term data records from MODIS and VIIRS observations will greatly benefit the space-based climate observing system. This is attributed to the high-quality measurements and extensive calibration efforts, from pre-launch to post-launch. This paper provides an overview of MODIS and VIIRS calibration history and approaches applied to establish and maintain sensor calibration traceability and accuracy. It illustrates calibration and performance issues through different phases of the mission using examples derived from ground testing equipment, on-board calibrators, and other calibration targets. Moreover, discussed in this paper are outstanding challenges and future efforts to maintain and improve sensor calibration stability and long-term data quality, and to better support the space-based climate observing system.

MODIS↗

Space-borne Doppler Weather Radar Modeling for Radar Design Evaluation

A model has been developed to predict the reflectivity and Doppler performance of a spaceborne weather radar for atmospheric aerosol and cloud monitoring. The goal is to predict radar sensitivity, resolution, uncertainties and other key performance metrics vs. radar design parameters and hardware nonidealities. Analytical formulas are readily available to predict key performance metrics of a space-borne radar system as a function of design parameters such as antenna size, spacecraft velocity, transmit power, and receive noise figure. Effects of some system nonidealities such as antenna pointing errors, power amplifier nonlinearity and phase noise can be estimated using idealized methods. These analytical formulas use idealized forms of the antenna radiation pattern and weather statistics to predict system performance. However, it is desirable to have a more physical model based on discretized weather volumes in which the particle size distribution, Doppler distribution, and other parameters can be varied to study how the radar hardware design parameters and nonidealities affect the measurement of the weather reflectivity and Doppler characteristics. This would allow the radar designers to have more insight into what is being measured and the hardware parameters and errors that need to be carefully controlled to achieve best radar performance, as well as potential methods to calibrate the system or correct errors. This presentation will demonstrate some proof-of-concept Ka-band simulations where the discretized model agrees with the analytical formulas for a simple case where the elements in the discretized weather volume are defined by a constant reflectivity and simple velocity vectors. In particular, the system sensitivity and Doppler uncertainty are evaluated by analytical formulas as well as the discretized model. Future work will expand on this to include more complex weather scenarios and the addition of system nonidealities.

Sara Tucker↗

NMR, MRI, and spectroscopic MRI in inhomogeneous fields

A method for locally creating effectively homogeneous or "clean" magnetic field gradients (of high uniformity) for imaging (with NMR, MRI, or spectroscopic MRI) both in in-situ and ex-situ systems with high degrees of inhomogeneous field strength. THe method of imaging comprises: a) providing a functional approximation of an inhomogeneous static magnetic field strength B.sub.0({right arrow over (r)}) at a spatial position {right arrow over (r)}; b) providing a temporal functional approximation of {right arrow over (G)}.sub.shim(t) with i basis functions and j variables for each basis function, resulting in v.sub.ij variables; c) providing a measured value .OMEGA., which is an temporally accumulated dephasing due to the inhomogeneities of B.sub.0({right arrow over(r)}); and d) minimizing a difference in the local dephasing angle .phi.({right arrow over (r)},t)=.gamma..intg..sub.0.sup.t{square root over (|{right arrow over (B)}.sub.1({right arrow over (r)},t')|.sup.2+({right arrow over (r)}{right arrow over (G)}.sub.shimG.sub.shim(t')+.parallel.{right arrow over (B)}.sub.0({right arrow over (r)}).parallel..DELTA..omega.({right arrow over (r)},t'/.gamma/).sup.2)}dt'-.OMEGA. by varying the v.sub.ij variables to form a set of minimized v.sub.ij variables. The method requires calibration of the static fields prior to minimization, but may thereafter be implemented without such calibration, may be used in open or closed systems, and potentially portable systems.

47 OTHER INSTRUMENTATION↗

Problems of millipound thrust measurement. The "Hansen Suspension"

Considered in detail are problems which led to the need and use of the 'Hansen Suspension'. Also discussed are problems which are likely to be encountered in any low level thrust measuring system. The methods of calibration and the accuracies involved are given careful attention. With all parameters optimized and calibration techniques perfected, the system was found capable of a resolution of 10 {mu} lbs. A comparison of thrust measurements made by the 'Hansen Suspension' with measurements of a less sophisticated device leads to some surprising results.

Carta, David G.↗

Systems and methods to maintain optimum stoichiometry for reactively sputtered films

The present invention relates to systems and methods for preparing reactively sputtered films. The films are generally thin transition metal oxide (TMO) films having an optimum stoichiometry for any useful device (e.g., a sub-stoichiometric thin film for a memristor device). Described herein are systems, methods, and calibrations processes that employ rapid control of partial pressures to obtain the desired film.

Source record↗

NMR spin-echo amplitude estimation

Technologies applicable to NMR spin-echo amplitude estimation are disclosed. Example methods may calibrate for distortion of a shape and estimated amplitude of measured NMR spin or gradient echoes. NMR spin or gradient echo measurements may be performed on a sample. The measured NMR spin or gradient echoes may be used to calculate an echo-shape calibration factor. The echo-shape calibration factor may estimate an effect of echo shape on estimated spin or gradient echo amplitude(s) of the NMR spin or gradient echoes. The echo-shape calibration factor may be used to correct for underestimation or overestimation of the spin or gradient echo amplitude(s).

Walsh, David O.↗

Systems and methods for in-situ calibration of scintillation spectrometer

A radiation spectrometer includes a scintillator, a photomultiplier, and one or more light-emitting diodes (LEDs). The scintillator receives radiation from the environment and emits light that is indicative of an energy of the radiation. The photomultiplier receives the light and outputs an electrical signal that is in turn indicative of the energy of the radiation. Spectral data can be generated based upon the electrical signal, wherein the spectral data indicates a number of radiation events in each of several energy bins. The one or more LEDs can emit LED light through the scintillator and toward the photomultiplier, wherein the LED light causes an LED peak in the spectral data that can be used to identify an absolute energy of radiation events in the spectral data.

Pfeifer, Kent B.↗

Characterization of Impedance Void Meter Performance in Two-Phase Flow Measurement

Over the past sixty years, exclusive work has been done on two-phase flow measurement and plenty of measurement methods have been developed. Among them, impedance void meter is considered to be a simple instrument with a quick and reliable response. Impedance measurement technique in two-phase flow has existed for more than five decades. Impedance void meter consists of two electrodes flush mounted on the flow channel which allows measurements to be performed over the entire flow area. In principle, impedance void meter is based on the different electrical conductance of water and air. The two electrodes connected with cable and voltage supplies and the air-water mixture between them form a complete circuit. The change of gas fraction occupied in the flow area is reflected by the change of impedance in this part, and then the change of the voltage signal of the circuit. Using the relationship between void fraction and voltage signal, area averaged void fraction can be measured. In a previous study by Bolman et al., the flow pattern was found that has an effect on the performance of the impedance void meter. This is due to the difference of the flow structure that affects the impedance of the flow area. Olsen suggested that the impedance void meter should fulfill the following factors in order to get good measurement results: gas phase is finely dispersed in the measuring flow area; the channel cross section should be uninterrupted; there should be several bubble diameters between sources of current. For pipe measurement, it is impossible to meet all these requirement. In this case, it is necessary to use other independent void fraction measurement methods to calibrate impedance void meter. However, the calibration result varies for different flow patterns; thus for those situations in which identifying the flow pattern is difficult, the results may not be reliable. The possible solution should be found in an aspect of impedance void meter design itself. Much work has been done focusing on the geometric design of impedance void meters. This study found that the distance between the two electrodes of the impedance void meter has an effect on the measurement performance. The primary focus of this study is to characterize the performance and measurement range of an impedance void meter in regards to its geometry aspect. In order to achieve this goal, a sensitivity study of the electrode distance was performed by numerical simulation. Based on the simulation results, an experiment was performed using an impedance void meter with different electrode distances. Additionally, a gamma densitometer and a multi single-sensor conductivity probe were also applied for the measurement comparison. Drift flux model was also used for the experimental results comparison. (authors)