Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

An initial measurement of a fast neutral spectrum for ion cyclotron range of frequency heated plasma using two-channel compact neutral particle analyzers in KSTAR

The accurate measurement of fast neutral particles from high energy ion tails is very important since it is a measure of ion cyclotron range of frequency (ICRF) or neutral beam (NB) ion heating. In KSTAR, fast neutral measurements have been carried out using a compact neutral particle analyzer based on the silicon photo diode since 2010. As a result, the fast neutral spectrum was observed consistent with the ion temperature, diamagnetic energy, and neutron flux in 2011. However, there was fast neutral count beyond the injected neutral beam energy in NB-only heating. Since it is difficult to expect the count unless the temperature is high enough to diffuse the fast ions beyond the beam energy it was required to identify what it is. During the 2012 campaign, the two-channel diode detectors with and without a particle stopper were used to distinguish fast neutral counts and other counts by a hard X-ray or neutrons. As a result, it was confirmed that the high energy component beyond the beam energy originated from a hard X-ray or neutrons. Finally, it was observed that faster neutrals are generated by ICRF heating and enhanced by electron cyclotron heating compared to NB-only heating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stimulated Raman scattering of laser in a plasma in the presence of a co-propagating electron beam

A relativistic electron beam co-propagating with a high power laser in plasma is shown to add to the growth of the stimulated Raman back scattering of the laser. The growth rate is sensitive to phase matching of electron beam with the plasma wave. In the case of phase mismatch, the growth rate drops by an order. The energy spread of the electron beam significantly reduces the effectiveness of the beam on the stimulated Raman process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quasi-optical design for systems to diagnose the electron temperature and density fluctuations on EAST

A system to simultaneously diagnose the electron temperature and density fluctuations is proposed for Experimental Advanced Superconducting Tokamak device. This system includes a common quasi-optical antenna, a correlation electron cyclotron emission (CECE) system that is used to measure the electron temperature fluctuations and a Doppler backscattering (DBS) system that is used to measure the electron density fluctuations. The frequency range of the proposed CECE system is 108-120 GHz, and this corresponds to a radial coverage of normalized radius ((R − R{sub 0})/a, R{sub 0} = 1850 mm, a = 450 mm) from 0.2 to 0.67 for the plasma operation with a toroidal magnetic field of 2.26 T. This paper focuses on the design of the quasi-optical antenna and aims at optimizing the poloidal resolution for different frequency bands. An optimum result gives the beam radius for the CECE system of 13-15 mm and this corresponds to a wave number range of k{sub θ} < 2.4 cm{sup −1}. The beam radius is 20-30 mm for V band (50-75 GHz) and 15-20 mm for W band (75-110 GHz).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validating and optimizing mismatch tolerance of Doppler backscattering measurements with the beam model (invited)

In this work, we use the beam model of Doppler backscattering (DBS), which was previously derived from beam tracing and the reciprocity theorem, to shed light on mismatch attenuation. This attenuation of the backscattered signal occurs when the wavevector of the probe beam’s electric field is not in the plane perpendicular to the magnetic field. Correcting for this effect is important for determining the amplitude of the actual density fluctuations. Previous preliminary comparisons between the model and Mega-Ampere Spherical Tokamak (MAST) plasmas were promising. In this work, we quantitatively account for this effect on DIII-D, a conventional tokamak. We compare the predicted and measured mismatch attenuation in various DIII-D, MAST, and MAST-U plasmas, showing that the beam model is applicable in a wide variety of situations. Finally, we performed a preliminary parameter sweep and found that the mismatch tolerance can be improved by optimizing the probe beam’s width and curvature at launch. This is potentially a design consideration for new DBS systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous reproduction of experimental profiles, fluxes, transport coefficients, and turbulence characteristics via nonlinear gyrokinetic profile predictions in a DIII-D ITER similar shape plasma

Experimental conditions obtained on the DIII-D tokamak in the ITER Similar Shape (ISS) have been compared extensively with nonlinear gyrokinetic simulation using the CGYRO code [Candy et al., J. Comput. Phys. 324, 73–93 (2016)] with comparisons spanning ion and electron heat fluxes, electron and impurity particle transport, and turbulent fluctuation levels and characteristics. Bayesian optimization techniques [Rodriguez-Fernandez et al., Nucl. Fusion 62(7), 076036 (2022)], combined with nonlinear gyrokinetics, have been used to obtain simultaneously Qi, Qe, and Γe flux-matched profiles that are found to be in good agreement with experimental profile measurements. Synthetic diagnostics were used to compare measured beam emission spectroscopy and correlation electron cyclotron emission turbulent fluctuations with nonlinear simulation. Although some disagreements exist, nonlinear simulations are found to be in generally good agreement with measured fluctuation levels, spectral shapes, and measured radial trends in low-k δne/ne and δTe/Te. Low (Li and C) and mid-Z (Ca) impurity transport was also compared with these flux-matched simulations. Fully stripped, low-Z impurities are well reproduced by the gyrokinetic modeling while clear disagreement exists in comparisons with mid-Z impurities. Nonlinear gyrokinetic investigation into the Z dependence of impurity transport in the ISS conditions is also performed, demonstrating clear trends of impurity diffusion with impurity Z (both D∝Z and D∝1/Z) that vary with the radial location studied. These trends are shown to result from the local dominance of ion temperature gradient or ∇n driven trapped electron mode turbulence and may contribute to the disagreement between simulation and experiment in mid-Z impurity transport. The results of this work represent one of the most complete validation studies of the gyrokinetic model performed to date and provide an example of new capabilities for predicting performance in future fusion devices.

Physics↗

Omniscopes: Large area telescope arrays with only NlogN computational cost

We show that the class of antenna layouts for telescope arrays allowing cheap analysis hardware (with correlator cost scaling as NlogN rather than N{sup 2} with the number of antennas N) is encouragingly large, including not only previously discussed rectangular grids but also arbitrary hierarchies of such grids, with arbitrary rotations and shears at each level. We show that all correlations for such a 2D array with an n-level hierarchy can be efficiently computed via a fast Fourier transform in not two but 2n dimensions. This can allow major correlator cost reductions for science applications requiring exquisite sensitivity at widely separated angular scales, for example, 21 cm tomography (where short baselines are needed to probe the cosmological signal and long baselines are needed for point source removal), helping enable future 21 cm experiments with thousands or millions of cheap dipolelike antennas. Such hierarchical grids combine the angular resolution advantage of traditional array layouts with the cost advantage of a rectangular fast Fourier transform telescope. We also describe an algorithm for how a subclass of hierarchical arrays can efficiently use rotation synthesis to produce global sky maps with minimal noise and a well-characterized synthesized beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The matter in extreme conditions instrument at the Linac Coherent Light Source

The LCLS beam provides revolutionary capabilities for studying the transient behavior of matter in extreme conditions. The particular strength of the Matter in Extreme Conditions instrument is that it combines the unique LCLS beam with high-power optical laser beams, and a suite of dedicated diagnostics tailored for this field of science. In this paper an overview of the beamline, the capabilities of the instrumentation, and selected highlights of experiments and commissioning results are presented.

43 PARTICLE ACCELERATORS↗

A real-time phase-space beam emittance monitoring system

An electron beam position and angle monitoring system, ps-BPM, has been shown to be able to measure the electron source position and angle at a single location in a beamline at a synchrotron source. This system uses a monochromator to prepare a photon beam whose energy is at that of the K -edge of an absorber filter. The divergence of the beam from the source gives an energy range that will encompass the K -edge of the filter. A measurement of the centre of the monochromatic beam and the K -edge location through the absorber filter gives the position and angle of the electron source. Here, it is shown that this system is also capable of measuring the source size and divergence at the same time. This capability is validated by measurement as the beam size in the storage ring was changed and by ray-tracing simulations. The system operates by measuring the photon beam spatial distribution as well as a K -edge filtered beam distribution. These additional measurements result in the ability to also determine the electron source size and divergence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-current lanthanum-hexaboride electron emitter for a quasi-stationary arc plasma generator

A high-current electron emitter on the basis of lanthanum hexaboride is developed for quasi-stationary arc plasma generators of ion sources. The emitter consists of a set of LaB{sub 6} washers interleaved with washers made of thermally extended graphite. The emitter is heated by the current flowing through the graphite washers. The thermal regime of emitter operation during plasma generation is considered. The emitter has been successfully used in the ion sources of the diagnostic injectors of fast hydrogen atomic beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LCLS RF Station Phase Anomaly Candidate Dataset

A public anomaly detection dataset constructed from RF station faults for phase at SLAC's LCLS (Linac Coherent Light Source). We have compiled a dataset of the RF station diagnostic phase data and the beam-position monitor (BPM) signals, alongside the hand labels, for a labeled study period. The dataset consists of two HDF5 files (one for train and one for test) containing the raw data, two CSV files containing information about the candidates. The CSV file for the test dataset also contains the label.

Liang, Jia [Stanford Univ., CA (United States). In↗

Double-probe potential measurements near the Spacelab 2 electron beam

As part of the Spacelab 2 mission the plasma diagnostics package (PDP) was released from the shuttle as a free-flying satellite. The PDP carried a quasi-static electric field instrument which made differential voltage measurements between two floating probes. At various times during the free flight, an electron beam was ejected from the shuttle. Large differential voltages between the double probes were recorded in association with the electron beam. However, analysis indicates that these large signals are probably not caused by ambient electric fields. Instead, they can be explained by considering three effects: shadowing of the probes from streaming electrons by the PDP chassis, crossing of the PDP wake by the probes, and spatial gradients in the fluxes of energetic electrons reaching the probes. Plasma measurements on the PDP show that energetic electrons exist in a region 20 m wide and up to at least 170 m downstream from the electron beam. At 80 or more meters downstream from the beam, the double probe measurements show that the energetic electron flux is opposite to the injection direction, as would be expected for a secondary returning electron beam produced by scattering of the primary electron beam.

Steinberg, J. T.↗

Experimental studies of an ECR plasma thruster

The Electron Cyclotron Resonance (ECR) thruster is a proposed electrodeless space electric propulsion device with interesting and little understood physics. A laboratory ECR thruster was run in a vacuum tank at pressures in the 10 exp -5 torr range using 2.12 GHz microwave beam and Ar gas propellant. Movable diagnostic probes (a Faraday cup and a gridded energy analyzer) measured plasma characteristics as propellant gas flow rate and input microwave power level were varied. Ion energy and flux data were used to calculate I(sp), propulsive efficiency, and thrust. The ion flux profiles show an unexpected depression on the thruster axis for low tank pressures that disappears as the tank pressure increases. Ion energies decrease as the flow rate and pressure increase, but the microwave power level affects the energy only negligibly. The calculated propulsion parameters demonstrate that the efficiency of the laboratory device is low, and that tank pressure greatly changes the performance.

Kaufman, D. A.↗

Passive spectroscopic diagnostics for magnetically confined fusion plasmas

Spectroscopy of radiation emitted by impurities and hydrogen isotopes plays an important role in the study of magnetically confined fusion plasmas, both in determining the effects of impurities on plasma behavior and in measurements of plasma parameters such as electron and ion temperatures and densities, particle transport, and particle influx rates. Spectroscopic diagnostics of plasma radiation that are excited by collisional processes in the plasma, which are termed passive spectroscopic diagnostics to distinguish them from active spectroscopic diagnostics involving injected particle and laser beams, are reviewed. A brief overview of the ionization balance in hot plasmas and the relevant line and continuum radiation excitation mechanisms is given. Instrumentation in the soft X-ray, vacuum ultraviolet, ultraviolet, visible, and near-infrared regions of the spectrum is described and examples of measurements are given. Paths for further development of these measurements and issues for their implementation in a burning plasma environment are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherent electron cooling proof of principle instrumentation design

The goal of the Coherent Electron Cooling Proof-of-Principle (CeC PoP) experiment being designed at RHIC is to demonstrate longitudinal (energy spread) cooling before the expected CD-2 for eRHIC. The scope of the experiment is to longitudinally cool a single bunch of 40 GeV/u gold ions in RHIC. This paper will describe the instrumentation systems proposed to meet the diagnostics challenges. These include measurements of beam intensity, emittance, energy spread, bunch length, position, orbit stability, and transverse and temporal alignment of electron and ion beams.

43 PARTICLE ACCELERATORS↗

First Steps Toward Incorporating Image Based Diagnostics Into Particle Accelerator Control Systems Using Convolutional Neural Networks

At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is especially appealing for non-intercepting diagnostics that could run continuously during beam operation. Here, we show results of a first step toward implementing such a controller: our trained CNN can predict multiple simulated downstream beam parameters at the Fermilab Accelerator Science and Technology (FAST) facility's low energy beamline using simulated virtual cathode laser images, gun phases, and solenoid strengths.

43 PARTICLE ACCELERATORS↗