Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “angular resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Infrared upconversion as a means of seeing in the dark

A new approach to seeing in the dark is described which is based on the principles of nonlinear optics employing a crystal such as lithium iodate. A nonlinear optical device capable of producing photons at higher frequencies from lower-frequency incident light is shown to upconvert infrared light directly into visible light. The major advantages of the infrared upconversion process is that it permits the infrared signal to be detected by photon-counting devices presently available for the visible spectral region, and that it can provide sensitivity to infrared radiation without the need for cryogenic cooling of the detector used. Early works on infrared upconversion are reviewed. The development of applications is discussed as to astronomical spectroscopy and infrared image upconversion involving either angular or positional resolution elements. The demonstration of infrared upconversion in rectangular waveguides of single-crystal GaAs by Anderson et al. (1971) indicates future possibilities in upconversion by the use of integrated optics devices.

Gurski, T. R.↗

Kinematics of supernova remnants in the Galaxy and LMC

The optical emission lines of six SNRs have been observed at very high angular and kinematic resolutions. Kinematic ion temperatures were derived, and evidence was found in shocked regions for Maxwellian microturbulence on scales approximately equal to or less than 0.01 pc, and for non-Maxwellian macroturbulence on scales greater than 0.1 pc. The widths of shocked regions in the Cygnus Loop and the existence of three types of spectral feature in the LMC remnants are discussed in terms of SNR evolution in cloudly interstellar media.

Shull, P., Jr.↗

The soft X-ray telescope for the SOLAR-A mission

The Soft X-ray Telescope (SXT) of the SOLAR-A mission is designed to produce X-ray movies of flares with excellent angular and time resolution as well as full-disk X-ray images for general studies. A selection of thin metal filters provide a measure of temperature discrimination and aid in obtaining the wide dynamic range required for solar observing. The co-aligned SXT aspect telescope will yield optical images for aspect reference, white-light flare and sunspot studies, and, possibly, helioseismology. This paper describes the capabilities and characteristics of the SXT for scientific observing.

Tsuneta, S.↗

Calibration of the AXAF Observatory: Overview

The Advanced X-ray Astrophysics Facility (AXAF) will soon begin its exploration of the x-ray universe, providing unprecedented angular and spectral resolution. Also unprecedented is the ambitious goal of calibrating the AXAF observatory to an accuracy of a few percent. Toward this end, AXAF science and engineering teams undertook an extensive calibration program at component, subsystem, and system levels. This paper is an overview of the system-level calibration activities, conducted over the past year at the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF).

Weisskopf, M.C.↗

Calibration of the AXAF Observatory: Overview

The Advanced X-ray Astrophysics Facility (AXAF) will soon begin its exploration of the x-ray universe, providing unprecedented angular and spectral resolution. Also unprecedented is the ambitious goal of calibrating the AXAF observatory to an accuracy of a few percent. Toward this end, AXAF science and engineering teams undertook an extensive calibration program at component, subsystem, and system levels. This paper is an overview of the system-level calibration activities, conducted over the past year at the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF).

Weisskopf, M. C.↗

Calibration of the AXAF Observatory: Overview

The Advanced X-ray Astrophysics Facility (AXAF) will soon begin its exploration of the X-ray universe, providing unprecedented angular and spectral resolution. Also unprecedented is the ambitious goal of calibrating the AXAF observatory to an accuracy of a few percent. Toward this end, AXAF science and engineering teams undertook an extensive calibration program at component, subsystem, and system levels. This paper is an overview of the system-level calibration activities, conducted over the past year at the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF).

Weisskopf, M. C.↗

The Calibration of AXAF: Overview

Soon, NASA's Advanced X-ray Astrophysics Facility (AXAF) will begin its exploration of the x-ray universe, providing unprecedent angular and spectral resolution. Here we summarize the results of the extensive calibration of the AXAF observatory, performed at MSFC's X-Ray Calibration Facility (XRCF), through the effort of several AXAF science and engineering teams.

Weisskopf, Martin C.↗

Polar Wind Measurements with TIDE/PSI and HYDRA on the Polar Spacecraft

The Thermal Ion Dynamics Experiment (TIDE) on the POLAR spacecraft has allowed sampling of the three-dimensional ion distributions with excellent energy, angular, and mass resolution. The companion Plasma Source Instrument, when operated, allows sufficient diminution of the electric potential to observe the polar wind at very high altitudes. In this presentation, we will describe the results of polar wind characteristics H+, He+, and 0+ as observed by TIDE at 5000 km and 8 RE altitudes. The relationship of the polar wind parameters with the solar zenith angle and with the day-night distance in the Solar Magnetic coordinate system will also be presented. We will compare these measurements with recent simulations of the photoelectron-driven polar wind using a couple fluid-semikinetic model. In addition, we will compare these polar wind observations with low-energy electrons sampled by the HYDRA experiment on POLAR to examine possible effects of the polar rain and photoelectrons and hopefully explain the large ion outflow velocity variations at POLAR apogee.

Su, Y. J.↗

Design and Performance of the HESSI Cryostat

The High Energy Solar Spectroscopic Imager (HESSI) spacecraft, to be launched in July 2000, will be used to observe the Sun with the finest angular and energy resolutions ever achieved from a few keV to hundreds of keV. The spacecraft will use an array of nine germanium (Ge) detectors, each 7.1 cm in diameter and 8.5 cm long, operating at 75K. The detectors are mounted in a cryostat on a common cold plate, and cooled by a small Stirling-cycle cryocooler. This paper describes the design of the cryostat, special accommodations for the Ge detectors, interfaces with the cryocooler, and thermal performance of the engineering test unit.

Boyle, R.↗

Methods of Viscosity Measurements in Sealed Ampoules

Viscosity of semiconductor and metallic melts is usually measured by oscillating cup method. This method utilizes the melts contained in vacuum sealed silica ampoules, thus the problems related to volatility, contamination, and high temperature and pressure can be alleviated. In a typical design, the time required for a single measurement is of the order of one hour. In order to reduce this time to a minute range, a high resolution (0.05 arc.sec) angular detection system is implemented in our design of the viscometer. Furthermore, an electromagnet generating a rotational magnetic field (RMF) is incorporated into the apparatus. This magnetic field can be used to remotely and non intrusively measure the electrical conductivity of the melt. It can also be used to induce a well controlled rotational flow in the system. The transient behavior of this flow can potentially yield the viscosity of the fluid. Based on RMF implementation, two novel viscometry methods are proposed in this work: a) the transient torque method, b) the resonance method. A unified theoretical approach to the three methods (oscillating cup, transient torque, and resonance) is presented along with the initial test results of the constructed apparatus. Advantages of each of the method are discussed.

Mazuruk, Konstantin↗

Final Qualification and Early On-Orbit Performance of the HESSI Cryocooler

The High Energy Solar Spectroscopic Imager (HESSI) spacecraft was launched on February 5, 2002. It now observes the Sun with the finest angular and energy resolutions ever achieved from a few keV to hundreds of keV, using an array of nine germanium detectors operating at 75K. The spacecraft was originally scheduled for launch in July 2000, but a vibration facility mishap damaged the primary structure of the spacecraft, along with the cryocooler, This paper describes issues in the qualification of a replacement for the original flight cooler, and describes early on-orbit performance.

Boyle, R. F.↗

Probing The Invisible Universe: The Case for Far-IR/Submillimeter Interferometry

The question "How did we get here and what will the future bring? captures the human imagination and the attention of the National Academy of Science s Astronomy and Astrophysics Survey Committee (AASC). Fulfillment of this fundamental goal requires astronomers to have sensitive, high angular and spectral resolution observations in the far-infrared submillimeter (far-IR-sub-mm) spectral region. With half the luminosity of the universe and vital information about galaxy, star and planet formation, observations in this spectral region require capabilities similar to those currently available or planned at shorter wavelengths. The scientific motivation, some mission concepts and technology requirements for far-IR-sub-mm space interferometers that can be developed in the 2010-2020 timeframe are summarized.

Leisawitz, D.↗

Probing the Invisible Universe: The Case for Far-IR/Submillimeter Interferometry

The question "How did we get here and what will the future bring?"captures the human imagination and the attention of the National Academy of Science's Astronomy and Astrophysics Survey Committee (AASC). Fulfillment of this fundamental goal requires astronomers to have sensitive, high angular and spectral resolution observations in the far-infrared/submillimeter (far- IR/sub-mm) spectral region. With half the luminosity of the universe and vital information about galaxy, star and planet formation, observations in this spectral region require capabilities similar to those currently available or planned at shorter wavelengths. In this paper we summarize the scientific motivation, some mission concepts and technology requirements for far-IR/sub-mm space interferometers that can be developed in the 2010-2020 timeframe.

Leisawitz, D.↗

The Chandra X-ray Observatory: An Astronomical Facility Available to the World

The Chandra X-ray observatory, one of NASA's "Great Observatories," provides high angular and spectral resolution X-ray data which is freely available to all. In this review I describe the instruments on chandra along with their current calibration, as well as the chandra proposal system, the freely-available Chandra analysis software package CIAO, and the Chandra archive. As Chandra is in its 6th year of operation, the archive already contains calibrated observations of a large range of X-ray sources. The Chandra X-ray Center is committed to assisting astronomers from any country who wish to use data from the archive or propose for observations

Smith, Randall K.↗

Reconstruction of 10(exp 20)ev Showers in EUSO and JEM EUSO

We describe the procedure to reconstruct 10(exp 20) ev showers in Extreme Universe Space Observatory (EUSO). We show the angular and energy resolution is excellent. We now apply this to the newly proposed Japanese JEM-EUSO and will present results at the meeting.

Andreev, V.↗

Development of a Silicon Tracker for the All-Sky Medium Energy Gamma-ray Observatory Prototype

The gamma-ray sky from several hundred keV to a hundred MeV has remained largely unexplored due to the challenging nature of detecting gamma rays in this regime. At lower energies, Compton scattering is the dominant interaction process whereas at higher energies pair production dominates, with a crossover at a few MeV. Thus, an instrument designed to work in this energy range must be optimized for both Compton and pair-production events. AMEGO, the All-sky Medium Energy Gamma-ray Observatory, a Probe-class mission in consideration for the 2020 decadal survey, is designed to operate at energies from 200 keV to > 10 GeV with over an order of magnitude increase in sensitivity and with superior angular and energy resolution compared to previous instruments. AMEGO comprises four major subsystems: a plastic anticoincidence detector for rejecting cosmic-ray events, a silicon tracker for tracking pair-production products and tracking and measuring the energies of Compton-scattered electrons, a cadmium-zinc-telluride (CZT) calorimeter for measuring the energy and location of Compton scattered photons, and a CsI calorimeter for measuring the energy of the pair-production products at high energies. A prototype instrument, known as ComPair, is under development at NASA’s Goddard Space Flight Center and the US Naval Research Laboratory. In this contribution, we provide details on the development of the silicon tracker subsystem.

Griffin, Sean↗

New Mission Concept: Investigation of the Galactic Center with the Galactic Center Explorer (GalCenEx)

The European Space Observatory INTEGRAL has been providing excellent results on X-ray and γ–ray astronomy since its launch in 2002. Among the most important results are the spectroscopy and imaging measurements of celestial γ-ray sources, including mapping the 511 keV radiation from the Galactic plane. However, the nature of the 511 keV positron annihilation line around the Galactic Center region is still a mystery. Similarly, the structure and nature of the Galactic Center supermassive black hole and its surroundings, as well as the structure of heavily populated sky regions such as Cygnus and Carina in γ-rays, remain unclear. We present a concept of a potential next-generation γ-ray telescope with the major science objectives: a) solve the mystery of the Galactic Center region 511 keV positron annihilation line by mapping the Galactic Center region with high energy (<1% FWHM) and angular (< 10 arcmin) resolution and with line sensitivity <10-5 ph cm-2 s-1; b) understand the nature of the Galactic Center supermassive black hole environment by creating a high-resolution spectral and intensity map of the surrounding region in 0.1 – 20 MeV γ rays; and c) explore Galactic chemical evolution and sites of explosive element synthesis by conducting high-sensitivity measurements of nuclear lines from Type 1a supernovae and other objects. The instrument is based on a novel high energy and position resolution CdZnTe Imager, coded aperture mask, and heavy-scintillator shield, and can be considered for a NASA Explorer mission.

Moiseev, Alexander↗

Multiabsorber Transition-Edge Sensors for X-Ray Astronomy

We are developing arrays of position-sensitive microcalorimeters for future x-ray astronomy applications. These position-sensitive devices commonly referred to as hydras consist of multiple x-ray absorbers, each with a different thermal coupling to a single-transition-edge sensor microcalorimeter. Their development is motivated by a desire to achieve very large pixel arrays with some modest compromise in performance. We report on the design, optimization, and first results from devices with small pitch pixels (<75 μm) being developed for a high-angular and energy resolution imaging spectrometer for Lynx. The Lynx x-ray space telescope is a flagship mission concept under study for the National Academy of Science 2020 decadal survey. Broadband full-width-half-maximum (FWHM) resolution measurements on a 9-pixel hydra have demonstrated ΔE(FWHM) = 2.23 ± 0.14 eV at Al-Kα, ΔE(FWHM) = 2.44 ± 0.29 eV at Mn-Kα, and ΔE(FWHM) = 3.39 ± 0.23 eV at Cu-Kα. Position discrimination is demonstrated to energies below <1 keV and the device performance is well-described by a finite-element model. Results from a prototype 20-pixel hydra with absorbers on a 50-μm pitch have shown ΔE(FWHM) = 3.38 ± 0.20 eV at Cr-Kα1. We are now optimizing designs specifically for Lynx and extending the number of absorbers up to 25/hydra. Numerical simulation suggests optimized designs could achieve ∼3 eV while being compatible with the bandwidth requirements of the state-of-the art multiplexed readout schemes, thus making a 100,000 pixel microcalorimeter instrument a realistic goal.

Smith, Stephen J.↗