Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Theoretical Study of the B(sup 3) Sigma(sup -, sub u) - X(sup3)Sigma(sub g, sup -) and B"(sup 3)Pi(sub u) - X(sup 3)Sigma(sub g, sup -) Band Systems of S(sub 2)

Multireference configuration-interaction (MRCI) wavefunctions and potential energy curves have been calculated for the X(sup 3)Sigma(sub g,sup -), B(sup 3)Sigma(sub u, Sup -) and B"(sup 3)Pi((sub u) states of S(sub 2) using correlation consistent Gaussian basis sets. These wavefunctions are utilized to compute the the transition dipole moments of the B(sup 3)Sigma(sub g, sup -) - X(sup 3) Sigma(sub g, sup -) and B"(sup 3)Pi(sub u) - X(sup 3)Sigma(sub g, sup -) systems. Oscillator strengths, transition probabilities, and radiative lifetimes are computed for the X-B system and comparison is made with experimental data.

Pradhan, Atul D.↗

Effects of Radiation and a High Iron Load on Bone Mineral Density

Astronauts on long duration space flight missions to the moon or mars are exposed to radiation and have increase iron (Fe) stores, both of which can independently induce oxidative stress and may exacerbate bone mass loss and strength. We hypothesize a high Fe diet and a fractionated gamma radiation exposure would increase oxidative stress and lower bone mass. Three mo-old, SD rats (n=32) were randomized to receive an adequate Fe diet (45 mg Fe/kg diet) or a high Fe diet (650 mg Fe/kg diet) for 4 wks and either a cumulative 3 Gy dose (fractionated 8 x 0.375 Gy) of gamma radiation (Cs-137) or sham exposure starting on day 14. Elisa kit assessed serum catalase, clinical analyzer assessed serum Fe status and ex vivo pQCT scans measured bone parameters in the proximal/midshaft tibia and femoral neck. Mechanical strength was assessed by 3-pt bending and femoral neck test. There is a significant decrease in trabecular bone mineral density (BMD) from radiation (p less than 0.05) and a trend in diet (p=0.05) at the proximal tibia. There is a significant interaction in cortical BMD from the combined treatments at the midshaft tibia (p less than 0.05). There is a trending decrease in total BMD from diet (p=0.07) at the femoral neck. In addition, high serum Fe was correlated to low trabecular BMD (p less than 0.05) and high serum catalase was correlated to low BMD at all 3 bone sites (p less than 0.05). There was no difference in the max load of the tibia or femoral neck. Radiation and a high iron diet increases iron status and catalase in the serum and decreases BMD.

Yuen, E.↗

Atomic kinetics of laboratory photoionized plasmas relevant to astrophysics. Final report

The major goal of this project was to study the atomic and radiation physics of photoionized plasmas driven by a broadband x-ray flux and its impact on plasma x-ray heating and ionization, emissivity and opacity, and radiation-hydrodynamics. This problem is relevant to the physics of accretion disks surrounding black holes, x-ray binaries, and active galactic nuclei in astrophysics. In addition, it is also important for understanding non-equilibrium laboratory plasmas driven by a distribution of photons. To this end, and motivated by previous and ongoing gas-cell experiments performed by the PI at the Z facility of Sandia National Laboratories, we developed a new experimental platform at the 1MA Zebra pulsed power accelerator of the University of Nevada, Reno based on using a gas jet produced by a supersonic nozzle. The gas jet is turned into a photoionized plasma driven by the x- ray flux from a wire-array z-pinch. Establishing this new experimental platform at Zebra was a major goal of this project. In addition, we have also dedicated effort to continue complementary experiments at the Z facility using the gas-cell photoionized plasma set up with support from the Fundamental Science Program at Z as well as to perform data processing and analysis, and theory and modeling simulations, including electron kinetics and radiation-hydrodynamics. Since we seek to test and establish what physics models are needed to describe photoionized plasma guided by experimental observation, these complementary experimental efforts were central to achieving the goals of this project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectroscopy of the extreme ultraviolet background radiation

Observations in the FUV and soft X-ray bands suggest that the interstellar medium contains several components of high-temperature gas and should be emitting in the EUV. Indeed, diffuse radiation has been detected in the EUV with photometric instruments, but no special measurements exist below 520 A. A unique grazing-incidence spectrometer has been designed to study the diffuse emission between 80 and 650 A with 10 to 20-A resolution. The instrument was launched on a Black Brant sounding rocket from White Sands Missile Range on April 22, 1986. Preliminary analysis shows the expected geocoronal and interplanetary He I 584-A emission, and possibly other features which may originate in the hot ionized interstellar gas. Flux limits to these possible emission lines are compatible with previous broadband measurements.

Labov, Simon↗

A three-dimensional hydrodynamic treatment of the hot dark matter cosmological scenario

The study computes the evolution of the hot dark matter (HDM) model containing both baryonic matter and dark matter for a post recombination Friedmann-Robertson-Walker universe. A locally valid Newtonian approximation is used to model a representative piece of the universe with size much less than the horizon. For the HDM model with the present chosen normalization, the hard X-ray (1-10 keV) radiation intensity is less than that in the observations (Wu et al., 1991) by a factor of 30. In agreement with other work, it is found that baryonic matter is slightly antibiased over dark matter on the cell scale, 0.5/h Mpc = 667 kpc. The HDM model with the present chosen parameters does not overproduce X-ray-luminous clusters, and there is a negative evolution in the late epochs in the sense that the number density of X-ray clusters was higher at 0.5 redshift than at 0 redshift at the brightest end.

Cen, Renyue↗

Radiation hardness characterization of LKH-5 scintillating glass

Radiation hardness is an important property to examine in scintillators to help determine their expected lifetime in application cases where significant radiation dose is expected. Industrial imaging systems using 9 MV linear accelerators for x-ray radiography are one such application where significant radiation doses are expected to the scintillators used. Cadmium tungstate scintillators (CWO) and Thallium doped Cesium Iodide scintillators (CsI(Tl)) are used in some high energy cargo x-ray radiography systems. However, CWO has a high manufacturing cost for adequately uniform crystals and CsI(Tl) does not have sufficient radiation hardness. LKH-5 glass is being investigated as a potential low cost replacement for CWO and CsI(Tl). In this experiment 36 samples of a terbium doped silicate glass called LKH-5 were irradiated at doses up to 5 MRad using a 9 MV linear accelerator, and the change in their transmission properties was observed. Additionally, the glass was discovered to be a radiation hard glass due to the relatively small change in the transmission of the glass: less than 3% per cm at its emission peak of 550 nm and 5 MRad. This is similar to CWO which has a reported reduction in transmitted light of 2% per cm at 5 MRad and the emission peak of 475 nm and better than CsI(Tl) which is reported to have a reduction in transmitted light of 5% per cm at the emission peak of 550 nm and 4.2 MRad dose. Furthermore, an annealing procedure is described that returned the transmission of the glass to pre-irradiation values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multispectral variable magnification glancing incidence x ray telescope

A multispectral, variable magnification, glancing incidence, x-ray telescope capable of broadband, high resolution imaging of solar and stellar x-ray and extreme ultraviolet radiation sources is discussed. The telescope includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable mirror carriers, each providing a different magnification, are positioned behind the primary focus at an inclination to the optical axis. Each carrier has a series of ellipsoidal mirrors, and each mirror has a concave surface covered with a multilayer (layered synthetic microstructure) coating to reflect a different desired wavelength. The mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A detector such as an x-ray sensitive photographic film is positioned at the second respective focus of each mirror so that each mirror may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected mirror on the second carrier to receive the radiation.

Hoover, Richard B.↗

High resolution imaging with multilayer soft X-ray, EUV and FUV telescopes of modest aperture and cost

The development of multilayer reflective coatings now permits soft X-ray, EUV and FUV radiation to be efficiently imaged by conventional normal incidence optical configurations. Telescopes with quite modest apertures can, in principle, achieve images with resolutions which would require apertures of 1.25 meters or more at visible wavelengths. The progress is reviewed which has been made in developing compact telescopes for ultra-high resolution imaging of the sun at soft X-ray, EUV and FUV wavelengths, including laboratory test results and astronomical images obtained with rocket-borne multilayer telescopes. The factors are discussed which limit the resolution which has been achieved so far, and the problems which must be addressed to attain, and surpass the 0.1 arc-second level. The application of these technologies to the development of solar telescopes for future space missions is also described.

Walker, Arthur B. C., Jr.↗

Energetic Correlation Between Solar Flares and Coronal Mass Ejections

We find a strong correlation between the kinetic energies (KEs) of the coronal mass ejections (CMEs) and the radiated energies of the associated solar flares for the events that occurred during the period of intense solar activity between 18 October and 08 November 2003. CME start times, speeds, mass and KEs were taken from Gopalswamy et al. (2005), who used SOHO/LASCO observations. The GOES observations of the associated flares were analyzed to find the peak soft X-ray (SXR) flux, the radiated energy in SXRs (L(sub sxR)), and the radiated energy from the emitting plasma across all wavelengths (L(sub hot)). RHESSI observations were also used to find the energy in non-thermal electrons, ions, and the plasma thermal energy for some events. For two events, SORCE/TIM observations of the total solar irradiance during a flare were also available to give the total radiated flare energy (L(sub total)).W e find that the total flare energies of the larger events are of the same order of magnitude as the CME KE with a stronger correlation than has been found in the past for other time intervals.

Dennis, Brian R.↗

Neutron radiation hardness of aluminum gallium nitride UV LEDs at various wavelengths

Radiation hard diagnostics are critical to the success of nuclear fusion at National Ignition Facility, Z, ITER, and prolonged space explorations. We have first demonstrated the exceptional proton radiation hardness of initial GaN devices and qualified their space flight and deployment for missions such as the Laser Interferometer Space Antenna and International Space Station. We have further conducted neutron radiation hardness experiments at Los Alamos Neutron Science Center by opening a new high fluence beam station. During 2014–2016, we irradiated multiple Aluminum Gallium Nitride (AlGaN) LEDs with a maximum fluence of 2.4 × 1013 neutrons/cm2 in 3 years and generated 54 161 current–voltage (I–V) scan traces. Our data processing program analyzes each and all I–V traces. In addition, we retrieved local temperature records to analyze and remove temperature effects in the outdoor environment. The I–V curve families of AlGaN UV LEDs with emitting wavelengths of 265, 275, and 310 nm were compared. The I–V curves of 265 nm AlGaN UV LEDs have the smallest deviations from the average value, while the I–V curves for 310 nm AlGaN LEDs showed the largest deviations from the average value. We have reached another important recommendation for the optimal use of multiple AlGaN optoelectronic devices or imaging arrays for inertially confined fusion diagnostics: Shorter wavelength devices at 265 nm exhibit more consistent radiation hardness performance than the 310 nm devices. Higher aluminum content LEDs or AlxGa1–xN devices with higher mole fraction x for generating shorter wavelengths have better radiation hardness for fusion diagnostics.

Sun, K. -X. (ORCID:0000000224659235)↗

Space radiation effects on poly(aryl-ether-ketone) thin films and composites

The purpose of this study was to assess the space durability of poly(aryl-ether-ketone) (PEEK) in the forms of films and graphite fiber reinforced composites. The influence of the film's crystallinity on electron radiation stability was evaluated using X-ray diffraction, DSC, FTIR, and mechanical property tests. The mechanical properties of the composites material were evaluated after electron radiation and after electron radiation followed by thermal cycling simulating 30 years in geosynchronous orbit.

Funk, Joan G.↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

Variable magnification variable dispersion glancing incidence imaging x ray spectroscopic telescope

A variable magnification variable dispersion glancing incidence x ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x ray and extreme ultraviolet radiation sources includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carriers each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a multilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x ray sensitive photographic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.

Hoover, Richard↗

Variable magnification variable dispersion glancing incidence imaging x-ray spectroscopic telescope

A variable magnification variable dispersion glancing incidence x-ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x-ray and extreme ultraviolet radiation sources includes a pirmary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carries each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a mutlilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x-ray sensitive photogrpahic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.

Hoover, Richard B.↗

Variable magnification glancing incidence x ray telescope

A multispectral glancing incidence x ray telescope is disclosed, which capable of broadband, high resolution imaging of solar and stellar x ray and extreme ultraviolet radiation sources includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more ellipsoidal mirrors are positioned behind the primary focus at an inclination to the optical axis, each mirror having a concave surface coated with a multilayer synthetic microstructure coating to reflect a desired wavelength. The ellipsoidal mirrors are segments of respective ellipsoids having a common first focus coincident with the primary focus. A detector such as an x ray sensitive photographic film is positioned at the second focus of each of the ellipsoids so that each of the ellipsoidal mirrors may reflect the image at the first focus to the detector. In one embodiment the mirrors are inclined at different angles and has its respective second focus at a different location, separate detectors being located at the respective second focus. The mirrors are arranged so that the magnification and field of view differ, and a solenoid activated arm may withdraw at least one mirror from the beam to select the mirror upon which the beam is to impinge so that selected magnifications and fields of view may be detected.

Hoover, Richard↗

Atomic Data Needs for X-Ray Astronomy

This publication contains written versions of most of the invited talks presented at the workshop on Atomic Data Needs for X-ray Astronomy which was held at NASA's Goddard Space Flight Center on December 16-1 7 1999. The idea of hosting such a workshop emerged from an imminent need to update and complete current atomic datasets in anticipation of a new era of high quality X-ray spectra starting with the launching of Chandra and XMM-Newton observatories. At first, our vision of the workshop was of a short and limited attendance event, given the specialization of the topic. But it, was soon realized, from the response to the first workshop announcement, that the topic was of much interest, to researchers working in X-ray spectra (physicists and astronomers). As a result, the workshop grew to approximately 120 participants from several countries. The kind of atomic data that interests us are those parameters needed for analysis and modeling of spectra shortward of about about 100 A and relevant to ionic species of astronomical interest. The physical mechanisms of interest in the formation of spectra include photoionization. collisional ionization, recombination (radiative and dielectronic). collisional excitation (by electrons and protons). and radiative deexcitation. Unique to X-ray spectroscopy are the ionization and excitation processes from inner-closed shells. in addition to the challenges in interpret,ing the medium resolution (epsilon/delta epsilon is about 0.05 - 0.1) data obtained by current X-ray astronomy experiments. Line wavelengths are of interest too, particularly owing to the high resolution spectra from the new experiments. The workshop was divided into five major areas: Observational Spectroscopy, Theoretical Calculations of Atomic Data, Laboratory Measurements of Atomic Parameters. Spectra Modeling, and Atomic Databases. One comforting finding from the work shop is that the enthusiasm felt by X-ray astronomers about the new observational missions seems to be shared by theoretical and experimental physicists. Talks were presented about several exciting new projects and experimental and theoretical techniques devoted to X-ray spectroscopy. Simultaneously, several new tools for spectral analysis and modeling have recently been developed, together with improved atomic databases. These proceeding are expected to be of interests to producers and users of atomic data. Moreover. the contributions presented here have been written in a way that can be used by a general audience of scientists and graduate students in X-ray astronomy, modelling, and in computational and experimental atomic physics.

Kallman, Timothy↗

Framework for X-ray mirror surface shape fitting

For accurate characterization of grazing-incidence X-ray mirrors, we present a comprehensive framework to fit measured surface shapes (either slope or height) of X-ray mirrors used in synchrotron radiation and free-electron laser facilities. We summarize the closed-form expressions of some typical surface shapes of X-ray mirrors including elliptic cylinders, hyperbolic cylinders, ellipsoids, hyperboloids, and diaboloids. This framework is composed of four layers: definition of standard shapes with closed-form expressions, generation of theoretical surface with pose parameters (six degrees of freedom defining an object's position and orientation relative to a coordinate system), parameter optimization with the ability to select which parameters are fit and which are held constant, and the development of user-friendly fitting function wrappers for particular fitting tasks. A few practical fitting examples are demonstrated to verify the effectiveness of the proposed fitting framework. We discuss the physical meanings of the fitting parameters, and provide several examples using the elliptic cylinder and ellipsoid shapes to highlight some features of the framework. Moreover, we provide the presented framework as open-source codes (MATLAB and Python codes available at https://github.com/nsls2omf/xmf) to the community to encourage academic collaboration and further improvements.

36 MATERIALS SCIENCE↗

A real-time electronic imaging system for solar X-ray observations from sounding rockets

A real-time imaging system for displaying the solar coronal soft X-ray emission, focussed by a grazing incidence telescope, is described. The design parameters of the system, which is to be used primarily as part of a real-time control system for a sounding rocket experiment, are identified. Their achievement with a system consisting of a microchannel plate, for the conversion of X-rays into visible light, and a slow-scan vidicon, for recording and transmission of the integrated images, is described in detail. The system has a quantum efficiency better than 8 deg above 8 A, a dynamic range of 1000 coupled with a sensitivity to single photoelectrons, and provides a spatial resolution of 15 arc seconds over a field of view of 40 x 40 square arc minutes. The incident radiation is filtered to eliminate wavelengths longer than 100 A. Each image contains 3.93 x 10 to the 5th bits of information and is transmitted to the ground where it is processed by a mini-computer and displayed in real-time on a standard TV monitor.

Davis, J. M.↗