Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VISIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Melt-grown semi-insulating Mn:β-Ga 2 O 3 single crystals exhibiting unique visible absorptions and luminescence

In this study, several acceptor dopants have been explored in β-Ga 2 O 3 to produce semi-insulating substrates and epitaxial films. Fe and Mg make up the majority of research thus far; however, other transition metals provide potential alternatives for optimized performance. β-Ga 2 O 3 bulk single crystals were grown by the Czochralski and vertical gradient freeze methods with a nominal dopant concentration of 0.25 at. % Mn. Ultraviolet-visible-near infrared spectroscopy and photoluminescence revealed polarization- and orientation-dependent optical absorptions (pleochroism) coupled with an orange luminescence. All samples were electrically insulating, on the order of 10 9 –10 11 ohm cm at room temperature, indicative of acceptor doping. Actual dopant concentrations of the intentionally doped transition metal and background impurities were determined via glow discharge mass spectrometry, indicating the macroscale segregation behavior. High-temperature resistivity measurements indicated an experimental acceptor level of 1.7 ± 0.2 eV. Hydrogenation of samples resulted in an increase in the orange luminescence and O–H stretching modes observable in the infrared spectrum. Density functional theory calculations were performed to determine the likely site-occupancy and acceptor level of Mn in the bandgap.

36 MATERIALS SCIENCE↗

Characterization of the LCLS “nanosecond two-bunch” mode for x-ray speckle visibility spectroscopy experiments

The generation of two X-ray pulses with tunable nanosecond scale time separations has recently been demonstrated at the Linac Coherent Light Source using an accelerator based technique. This approach offers the opportunity to extend X-ray Photon Correlation Spectroscopy techniques to the yet unexplored regime of nanosecond timescales by means of X-ray Speckle Visibility Spectroscopy. As the two pulses originate from two independent Spontaneous Amplified Stimulated Emission processes, the beam properties fluctuate from pulse pair to pulse pair, but as well between the individual pulses within a pair. However, two-pulse XSVS experiments require the intensity of the individual pulses to be either identical in the ideal case, or with a accurately known intensity ratio. We present the design and performances of a non-destructive intensity diagnostic based on measurement of scattering from a transparent target using a high-speed photo-detector. Individual pulses within a pulse pair with time delays as short as 0.7 ns can be resolved. Moreover, using small angle coherent scattering, we characterize the averaged spatial overlap of the focused pulse pairs. Furthermore, the multi-shot average-speckle contrasts from individual pulses and pulse pairs are compared.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication and testing of diamond-machined gratings in ZnSe, GaP, and bismuth germanate for the near infrared and visible

High quality immersion gratings for infrared applications have been demonstrated in silicon and germanium. To extend this technology to shorter wavelengths other materials must be investigated. We selected three materials, zinc selenide, gallium phosphide and bismuth germanate (Bi{sub 4}Ge{sub 3}O{sub 12}), based on high refractive index, good visible transmission and commercial availability in useful sizes. Crystal samples were diamond turned on an ultra-precision lathe to identify preferred cutting directions. Using this information we diamond-flycut test gratings over a range of feed rates to determine the optimal cutting conditions. For both ZnSe and GaP good surface quality was achieved at feed rates up to 1.0 cm/minute using a special compound angle diamond tool with negative rake angles on both cutting surfaces. The surface roughness of the groove facets was about 4 nm. A Zygo interferometer measured grating wavefront errors in reflection. For the ZnSe the RMS error was < {lambda}/20 at 633nm. More extensive testing was performed with a HeNe laser source and a cooled CCD camera. These measurements demonstrated high relative diffraction efficiency (> 80%), low random groove error (2.0 nm rms), and Rowland ghost intensities at < 0.1%. Preliminary tests on bismuth germanate show high tool wear.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visibility of microcalcification clusters and masses in breast tomosynthesis image volumes and digital mammography: A 4AFC human observer study

Purpose: To investigate the visibility of simulated lesions in digital breast tomosynthesis (BT) image volumes compared with 2D digital mammography (DM). Methods: Simulated lesions (masses and microcalcifications) were added to images of the same women acquired on a DM system (Mammomat Novation, Siemens) and a BT prototype. The same beam quality was used for the DM and BT acquisitions. The total absorbed dose resulting from a 25-projection BT acquisition and reconstruction (BT{sub 25}) was approximately twice that of a single DM view. By excluding every other projection image from the reconstruction (BT{sub 13}), approximately the same dose as in DM was effected. Simulated microcalcifications were digitally added with varying contrast to the DM and BT images. Simulated masses with 8 mm diameter were also added to BT images. A series of 4-alternative forced choice (4AFC) human observer experiments were conducted. Four medical physicists participated in all experiments, each consisting of 60 trials per experimental condition. The observers interpreted the BT image volumes in cine-mode at a fixed image sequence speed. The required threshold contrast (S{sub t}) to achieve a detectability index (d') of 2.5 (i.e., 92.5% correct decisions) was determined. Results: The S{sub t} for mass detection in DM was approximately a factor of 2 higher than required in BT indicating that the detection of masses was improved under BT conditions compared to DM. S{sub t} for microcalcification detection was higher for BT than for DM at both BT dose levels (BT{sub 25} and BT{sub 13}), with a statistically significant difference in S{sub t} between DM and BT{sub 13}. These results indicate a dose-dependent decrease in detection performance in BT for detection of microcalcifications. Conclusions: In agreement with previous investigations, masses of size 8 mm can be detected with less contrast in BT than in DM indicating improved detection performance for BT. However, for the investigated microcalcifications, the results of this study indicate potentially worse performance for BT than for DM at the same dose level.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-407: Evaluation of the Stopping Power and Imaging Visibility for Iodine Based Contrast in Proton Therapy

Purpose: The purpose of this study was to investigate the difference between calculated and measured relative linear stopping power (RLSP) for contrast medium in proton therapy. Furthermore, the visibility for different concentrations in prostate phantom on orthogonal X-ray system was evaluated Methods and Materials: In prostate cancer patient, rectal balloon along with the contrast media was used to visualize the balloon position, thus facilitating the patient setup during each fraction of the uniform scanning proton treatment. There were no fiducial markers implanted in the prostate for this patient. A blue wax phantom with outer dimensions 10cm(H) x 14.5cm(L) x 10cm(W) was made in house. To hold iodine based contrast solution, a rectangular shaped hole with dimensions 7cm(H) x 8cm(L) x 4cm(W) was made inside the phantom. Organically bound 8.5% iodine based Cystografin Dilute contrast agent with molecular formula C11H9I3N2O4.C7H17NO5 was used in this study. Six solutions were prepared; each mixture of water and iodine based contrast agent at different concentrations as 0%, 5%, 10%, 20%, 30% and 50%. During computed tomographic(CT) simulation, solutions were placed together at the isocenter of CT and scanned at 120kVp using the same protocol as for prostate cancer patients. The treatment planning was done in CMS-XiO system. Multi-layer-ion-chamber (MLIC) was used to measure residual proton range. Results: The 50% concentration contrast solution was used during treatment for better visualization on orthogonal X-ray image. The measured RLSP for 5%, 10%, 20%, 30% & 50% solutions were 1.005, 1.010, 1.018, 1.023 & 1.033; and similarly calculated RLSP from XiO were 1.090, 1.135, 1.222, 1.299 & 1.448 respectively. Conclusion: The treatment planning system could overestimates the relative stopping power of contrast solution with high concentrations. It is recommended to override the contrast with measured RLSP for high atomic number based contrast solution in treatment planning for proton therapy.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-JeP2-01: Inter-Observer Delineation Comparison of Visible Glandular Breast Tissue On Magnetic Resonance Imaging and Computed Tomography (prone and Supine)

Purpose: Breast cancers predominantly arise from Glandular Breast Tissue (GBT). If the GBT can be treated effectively post-operatively utilising radiotherapy this may be adequate volumetric coverage for adjuvant breast radiotherapy. Adequate imaging of the GBT is necessary and will be assessed between MRI and CT modalities. GBT visualisation is acknowledged to be qualitatively superior on Magnetic Resonance Image (MRI) compared to Computed Tomography (CT), the current radiotherapy imaging standard, however this has not been quantitatively assessed. For radiotherapy purposes it is important that any treatment volume can be consistently defined between observers. This study investigates the consistency of CT and MRI GBT contours for potential radiotherapy planning. Methods: Ten experts (9 breast radiation oncologists and 1 radiologist) contoured the extent of the visible GBT for 33 patients on MRI and CT (both without contrast), which was performed according to a contouring guideline in supine and prone patient positions. The GBT volume was not a conventional whole breast radiotherapy planning volume, but rather the extent of GBT that was indicated from the CT or MR imaging. Volumes were compared utilizing the dice similarity coefficient (DSC), kappa statistic, and Hausdorff Distances (HDs) to ascertain the modality that was most consistently volumed. Results: The inter-observer concordance was of substantial agreement (kappa above 0.6) for the CT supine, CT prone, MRI supine and MRI prone datasets. The MRI GBT volumes were larger than the CT GBT volumes (p<0.001). Inter-observer conformity was higher for CT than MRI, although the magnitude of this difference was small (VOI<0.04). Conformity between modalities (CT and MRI) was in agreement for both prone and supine, DSC=0.75. Prone GBT volumes were larger than supine for both MRI and CT. Conclusion: MRI improves the extent of GBT delineation. The role of MRI guided, GBT-targeted radiotherapy requires investigation in a clinical trial. This work was supported by a grant number APP1033237 from Cancer Australia and the National Breast Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Large-area low-noise flexible organic photodiodes for detecting faint visible light

Silicon photodiodes are the foundation of light-detection technology; yet their rigid structure and limited area scaling at low cost hamper their use in several emerging applications. A detailed methodology for the characterization of organic photodiodes based on polymeric bulk heterojunctions reveals the influence that charge-collecting electrodes have on the electronic noise at low frequency. The performance of optimized organic photodiodes is found to rival that of low-noise silicon photodiodes in all metrics within the visible spectral range, except response time, which is still video-rate compatible. Solution-processed organic photodiodes offer several design opportunities exemplified in a biometric monitoring application that uses ring-shaped, large-area, flexible, organic photodiodes with silicon-level performance.

47 OTHER INSTRUMENTATION↗

Mechanisms of ZnO Luminescence in the Visible Spectral Region

Existing models of zinc oxide luminescence in the visible spectral region are considered and comparatively analyzed. Experiments are performed with ceramics obtained from initial ZnO powder and ZnO powders annealed in vacuum (ZnO-vac) and in air (ZnO-air). The luminescence characteristics of the ceramics, namely, emission and excitation spectra, kinetics, and temperature stability, are studied. The ZnO-vac ceramics exhibits green luminescence caused by neutral oxygen vacancies. The luminescence of ZnO-air ceramics is shifted to the red and is presumably related to residual lithium impurity. The ceramics differ in the luminescence excitation spectra, time characteristics, and temperature stability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging of spatial distributions of the millimeter wave intensity by using the Visible Continuum Radiation from a discharge in a Cs–Xe mixture. Part II: Demonstration of application capabilities of the technique

The paper presents the second part of the review on a high-sensitive technique for time-resolved imaging and measurements of the 2D intensity profiles of millimeter-wave radiation by means of Visible Continuum Radiation emitted by the positive column of a medium-pressure Cs-Xe DC Discharge (VCRD method). The first part of the review was focused on the operating principles and fundamentals of this new technique [Plasma Phys. Rep. 43, 253 (2017)]. The second part of the review focuses on experiments demonstrating application of this imaging technique to measure the parameters of radiation at the output of moderate-power millimeter-wave sources. In particular, the output waveguide mode of a moderate-power W-band gyrotron with a pulsed magnetic field was identified and the relative powers of some spurious modes at the outputs of this gyrotron and a pulsed D-band orotron were evaluated. The paper also reviews applications of the VCRD technique for real-time imaging and nondestructive testing with a frame rate of higher than 10 fps by using millimeter waves. Shadow projection images of objects opaque and transparent for millimeter waves have been obtained using pulsed watt-scale millimeter waves for object illumination. Near video frame rate millimeter-wave shadowgraphy has been demonstrated. It is shown that this technique can be used for single-shot screening (including detection of concealed objects) and time-resolved imaging of time-dependent processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emission intensity in the visible and IR spectral ranges from Si-based structures formed by direct bonding with simultaneous doping with erbium (Er) and europium (Eu)

The photo- and electroluminescence spectra of silicon-based structures formed by direct bonding with simultaneous doping with rare-earth metals are studied. It is shown that emission in the visible and IR spectral ranges can be obtained from n-Si:Er/p-Si and n-Si:Eu/p-Si structures fabricated by the method suggested in the study. The results obtained make this method promising for the fabrication of optoelectronic devices.

36 MATERIALS SCIENCE↗

A CVD Diamond-Based Photodetector for the Visible and Near-IR Spectral Range

A photodetector for the visible and near-IR spectral range has been created on the basis of a chemical- vapor-deposited diamond modulation-doped with boron. The detected electromagnetic radiation is absorbed in a thin Cr (7 nm)–Au (5.5 nm) bimetallic sublayer deposited on the surface of a modulationdoped diamond film comprising a highly doped (up to 5 × 10{sup 19} cm{sup –3}) 3-nm-thick delta-layer, low-doped (~10{sup 17} cm{sup –3}) 800-nm-thick sublayer, and highly doped (10{sup 20} cm{sup –3}) ~10-μm-thick sublayer with an ohmic Ti(50 nm)/Pt(15 nm)/Au(30 nm) contact. Holes generated in the bimetallic sublayer diffuse into diamond and are accelerated by an electric field in the low-doped sublayer to form a response photocurrent. The ampere/watt responsivity of the photodetector reaches 1 μA/W at a radiation wavelength of 445 nm and 0.18 μA/W at 1.06 μm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ Visible Light and Thermal Imaging Data from a Laser Powder Bed Fusion Additive Manufacturing Process Co-Registered to X-ray Computed Tomography and Fatigue Data

This dataset is comprised of in situ sensing data collected during a laser-based powder bed fusion additive manufacturing process, as well as rasterized scan path information, post-build X-ray computed tomography (XCT), and fatigue test results. A total of 64 cylinders, approximately 15 mm in diameter and 102 mm tall, were printed out of stainless steel 316H on a Colibrium Additive Concept Laser M2 Series 5 machine. Parameters known to produce dense material were used to construct 56 of these cylinders, while the remaining 8 cylinders were printed with relatively high energy density parameters prone to producing keyhole pores. In addition, two spatter generation blocks were constructed upstream of the 64 cylinders such that ejecta produced during the melting of the spatter generators were stochastically seeded onto the 64 cylinders. Based on previous experiments, these spatter particles were theorized to produce stochastic lack-of-fusion pores. During the construction of the build, high-resolution images of reflected light in the visible spectrum were captured both before and after recoating for each print layer. Additionally, temporally integrated thermal imaging in the near infrared spectrum produced integrated sum and max images on a layerwise basis. The multimodal in situ data has been co-registered to the build plate coordinate system, allowing for identification of process anomalies (e.g., spatter particles) apparent in the two sensors. Following construction of the build, the cylinders were subjected to XCT to identify internal flaws, and the resulting data have also been registered to the build plate coordinate system. Finally, 60 of the 64 cylinders were machined into fatigue coupons conforming to ASTM E466 and subsequently subjected to either high- or -low-cycle fatigue testing. The results of the fatigue tests have also been included in the dataset, and the XCT data corresponded to the approximate location of the gauge sections of the machine fatigue specimen geometry.

42 ENGINEERING↗

Comment on the reported fiber attenuations in the visible regime in 'Fabrication of glass photonic crystal fibers with a die-cast process'

We comment on the recent paper by Zhou et al. [Appl. Opt.45, 4433 (2006)APOPAI0003-693510.1364/AO.45.004433], in which transmission losses of 0.2-0.3 dB/m were claimed across the wavelength range 420-900 nm in a high-index (nd=1.80518 at 587.6 nm) SF6 glass-based photonic crystal fiber fabricated by novel die-cast technique. If confirmed, these losses are at least 1 order of magnitude lower than previous reported losses of SF6 photonic crystal fibers from other fabrication approaches. Here we present a statistic survey on the relationship between the refractive index and the bulk material attenuation, based on a large number of commercial Schott optical glasses with the nd ranging between 1.40 and 2.05. It shows that the loss of a high-index (nd=1.80) glass optical fiber should be at the levels of 10-50 dB/m at 420 nm and 1-10 dB/m at 500 nm, respectively. Moreover, the material attenuation of such a high-index glass fiber should intrinsically show a large decay, from 10-50 dB/m at 420 nm to the level of 1 dB/m at 700 nm, which arises from the tail on the UV absorption edge of the high-index glass extending to the visible region. Therefore, we conclude that: (1) the low loss of 0.2-0.3 dB/m reported in the cited paper is abnormally one or two magnitudes lower than the material attenuation that a high-index (nd=1.80) glass optical fiber should have in the range between 420 and 500 nm and that (2) the flat loss curve between 420 and 700 nm in the cited paper deviates greatly from the intrinsic behavior of a high-index (nd=1.80) glass fiber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visible (400- to 700-nm) chirped-grating-coupled waveguide spectrometer

An integrable on-chip spectrometer, based on a transversely-chirped-grating waveguide-coupler for the 400- to 700-nm visible spectral range is demonstrated. For a fixed angle of incidence, the coupling wavelength is dependent on the local grating period and the waveguide structure. The transversely-chirped-input grating is fabricated on a SiO 2 -Si 3 N 4 -SiO 2 waveguide atop a Si substrate by interferometric lithography in two sections on a single silicon substrate. A uniform period grating, separated from the input coupler by a propagation region, is provided for out-coupling to a 2048 element CMOS detector array. The incident light with wavelength spanning 400- to 700-nm is coupled into waveguide at 33.5° through the chirped grating coupler. A resolution of ∼ 1.2 nm is demonstrated without any signal processing reconstruction.

Wang, Xuemei↗

Broadband and linear polarization metasurface carpet cloak in the visible

In the past few years, carpet cloaking has attracted interest because of its feasibility at optical frequencies and potential in stealth technologies. Metasurfaces have been proposed as a method to engineer ultra-thin carpet cloaking surfaces due to their abilities to manipulate wavefronts, polarization, and phase at subwavelength scale. However, achieving broadband carpet cloaking with a significant bandwidth is one of the key remaining challenges for metasurface designs. To date, broadband carpet cloaking based on metasurfaces has not been achieved, and operation has been limited to discrete wavelengths. In this work, we propose and numerically demonstrate a novel metasurface design for broadband carpet cloaking with linear polarization at visible wavelengths from 650 nm to 800 nm. Overall, our proposed method is a promising approach for broadband structured interfaces.

42 ENGINEERING↗

Telecom-to-visible quantum frequency converter on a silicon nitride chip

Quantum frequency conversion serves a key role in the realization of hybrid quantum networks by interfacing between wavelength-incompatible platforms. Here we present what is believed to be the first quantum frequency converter connecting visible and telecom domains on a silicon nitride (SiN) chip, using Bragg-scattering four-wave mixing to upconvert heralded single photons from 1260 to 698 nm, which covers a 192 THz span. We examine the noise sources in SiN and devise approaches to suppress noise photons at the source and target frequencies to enable measurements at the single-photon level. We demonstrate an on-chip conversion efficiency of 5% in photon flux and describe design modifications that can be implemented to significantly improve it. Our results pave the way for the implementation of complementary metal-oxide-semiconductor (CMOS)-compatible devices in quantum networks.

59 BASIC BIOLOGICAL SCIENCES↗

Application of visible and near-infrared spectroscopy to classification of Miscanthus species

Here, the feasibility of visible and near infrared (NIR) spectroscopy as tool to classify Miscanthus samples was explored in this study. Three types of Miscanthus plants, namely, M. sinensis , M. sacchariflorus and M. fIoridulus , were analyzed using a NIR spectrophotometer. Several classification models based on the NIR spectra data were developed using line discriminated analysis (LDA), partial least squares (PLS), least squares support vector machine regression (LSSVR), radial basis function (RBF) and neural network (NN). The principal component analysis (PCA) presented rough classification with overlapping samples, while the models of Line_LSSVR, RBF_LSSVR and RBF_NN presented almost same calibration and validation results. Due to the higher speed of Line_LSSVR than RBF_LSSVR and RBF_NN, we selected the line_LSSVR model as a representative. In our study, the model based on line_LSSVR showed higher accuracy than LDA and PLS models. The total correct classification rates of 87.79 and 96.51% were observed based on LDA and PLS model in the testing set, respectively, while the line_LSSVR showed 99.42% of total correct classification rate. Meanwhile, the lin_LSSVR model in the testing set showed correct classification rate of 100, 100 and 96.77% for M. sinensis , M. sacchariflorus and M. fIoridulus , respectively. The lin_LSSVR model assigned 99.42% of samples to the right groups, except one M. fIoridulus sample. The results demonstrated that NIR spectra combined with a preliminary morphological classification could be an effective and reliable procedure for the classification of Miscanthus species.

59 BASIC BIOLOGICAL SCIENCES↗

Drone flight visible images, digital elevation maps, and geotiffs, Council, Seward Peninsula, Alaska, USA, July 2017

Remote sensing data collected from Lawrence Berkeley National Laboratory’s (LBNL) unmanned aerial system (UAS) quadcopter platform – Inspire-1 – operated by the Ameriflux Management Project (ameriflux.lbl.gov) Technical Team. The Insprire-1 is a visible imagery UAS platform that simultaneously measures very high spatial resolution optical red/green/blue (RGB) at regular intervals along each flight path. This package includes data from four flight paths over the NGEE Arctic Council Road Site near mile marker 71 in the Seward Peninsula, Alaska in July 2017. Derived image products for each flight include ortho-mosaiced RGB, an RGB-based digital surface model (DSM) using the structure from motion (SfM) technique, and a digital terrain model (DTM). Ancillary aircraft data, flight mission parameters, and general flight conditions are also included. Unprocessed and processed data products are included in this package (processing levels 0-2). This metadata document contains flight campaign, instrument and file metadata, along with a description of data processing levels, data products and file naming scheme.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic) was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy’s Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy’s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗