Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Technology Solutions Case Study: Combustion Safety for Appliances Using Indoor Air

This case study describes how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

Building America↗

Technology Case Studies: Retrofit Integrated Space and Water Heating - Field Assessment

Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water and forced air space heating. Called 'Combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent.

boiler based combi systems↗

Building America Case Study: Combustion Safety Simplified Test Protocol, Chicago Illinois, and Minneapolis, Minnesota

"9Combustion safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Science Behind 'The Martian' - Staying Warm on Mars

Set in the not-too-distant future, “The Martian” is the story of an astronaut stranded on Mars who has to rely on his own wit and ingenuity to survive the planet’s hostile conditions. If Mark Watney’s mission were real, Oak Ridge National Laboratory would be playing a vital role in his survival, as it would be the sole source of the Plutonium-238 needed for the RTG, as well as the fuel’s containment material in the form of iridium clad vent sets.

07 ISOTOPE AND RADIATION SOURCES↗

Pool scrubbing under jet injection regime: An enhancement of the SPARC90 code

The SPARC90 code was developed to calculate the aerosol pool trapping during vent discharge processes, at low gas velocities. However, there are accident sequences, like SGTR core meltdown sequences, at which particle laden gases reach the aqueous ponds at very high velocities and new particle removal mechanisms become effective right at the inlet. As a result of the shearing off of roll wave water crests, water droplets are entrained in the gas core and sweep out aerosol particles, mainly by inertial impaction and interception. This paper summarizes the update of the SPARC90 code based on state-of-the-art equations for jet hydrodynamics and aerosol removal. Equations for variables like droplets population, size and velocity have been implemented. Based on the anticipated conditions in case of an SGTR severe accident sequence, comparisons of estimates from this new version (SPAR90-Jet) and the original one are set in terms of decontamination factor. Even though further work is still ahead, this work highlights how substantial particle retention at the pool inlet can reach under jet regime and how different aerosol removal mechanisms are with respect to the globule injection regime. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Severe Accident Research Directions after Fukushima

The accidents at the Fukushima Daiichi nuclear power station in March of 2011 renewed interest globally in the nature, causes, and health and economic consequences of severe accidents involving core damage and containment impairment. As a result of these accidents, research has been conducted into the modeling and phenomenological understanding of the accidents at Fukushima and the response and effectiveness of mitigating measures such as emergency water injection, primary system depressurization and containment venting actions. An important example of this is the jointly conducted OECD-NEA organized Benchmark of the Fukushima Accidents (BSAF project) where accident reconstruction analyses using computer codes such as MELCOR and MAAP are ongoing. Even prior to the Fukushima accidents, the Sandia/NRC sponsored State of Art Reactor Consequence Analyses (SOARCA) foreshadowed the accidents in Japan where long-term and short-term station blackout accidents in boiling water reactors with Mark-1 containment were analyzed showing striking similarities to the accidents at Fukushima. These analyses also highlighted important differences in our prior understanding, in particular the importance of suppression pool thermal stratification and the extraordinary operation of the Fukushima Unit-2 reactor core isolation cooling (RCIC) system, prompting addition research into both of these areas. Additionally, the focus of the world's major computer codes on modeling the Fukushima accidents in the BSAF effort, led to several 'Crosswalk' comparisons between code predictions, highlighting subtle but important modeling differences between the codes and identifying areas where modeling improvements can be made. Collectively, these research areas are aimed at improving our understanding of severe accident progression and real-world response of safety related systems and components, and should lead to improved accident response and mitigation capabilities in the future. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ascent velocity and dynamics of the Fiumicino mud eruption, Rome, Italy: MUD ASCENT VELOCITY

drilling triggered the eruption of mud near the international airport of Fiumicino (Rome, Italy). We monitored the evolution of the eruption and collected samples for laboratory characterization of physicochemical and rheological properties. Over time, muds show a progressive dilution with water; the rheology is typical of pseudoplastic fluids, with a small yield stress that decreases as mud density decreases. The eruption, while not naturally triggered, shares several similarities with natural mud volcanoes, including mud componentry, grain-size distribution, gas discharge, and mud rheology. We use the size of large ballistic fragments ejected from the vent along with mud rheology to compute a minimum ascent velocity of the mud. Computed values are consistent with in situ measurements of gas phase velocities, confirming that the stratigraphic record of mud eruptions can be quantitatively used to infer eruption history and ascent rates and hence to assess (or reassess) mud eruption hazards.

58 GEOSCIENCES↗

An experimental study of the role of subsurface plumbing on geothermal discharge

In order to better understand the diverse discharge styles and eruption intervals observed at geothermal features, we performed here three series of laboratory experiments with differing plumbing geometries. A single, straight conduit that connects a hot water bath (flask) to a vent (funnel) can originate geyser-like periodic eruptions, continuous discharge like a boiling spring, and fumarole-like steam discharge, depending on the conduit length and radius. The balance between the heat loss from the conduit walls and the heat supplied from the bottom determines whether and where water can condense which in turn controls discharge style. Next, we connected the conduit to a cold water reservoir through a branch, simulating the inflow from an external water source. Colder water located at a higher elevation than a branching point can flow into the conduit to stop the boiling in the flask, controlling the periodicity of the eruption. When an additional branch is connected to a second cold water reservoir, the two cold reservoirs can interact. Our experiments show that branching allows new processes to occur, such as recharge of colder water and escape of steam from side channels, leading to greater variation in discharge styles and eruption intervals. This model is consistent with the fact that eruption duration is not controlled by emptying reservoirs. We show how differences in plumbing geometries can explain various discharge styles and eruption intervals observed in El Tatio, Chile, and Yellowstone, USA.

58 GEOSCIENCES↗

Flow‐to‐fracture transition in a volcanic mush plug may govern normal eruptions at Stromboli

Abstract Stromboli is a model volcano for studying eruptions driven by degassing. The current paradigm posits that Strombolian eruptions represent the bursting of gas slugs ascending through melt‐filled conduits, but petrological observations show that magma at shallow depth is crystalline enough to form a three‐phase plug consisting of crystals, bubbles, and melt. We combine a 1‐D model of gas flushing a crystalline mush with a 3‐D stress model. Our results suggest that localized gas segregation establishes hot conduits of mobile magma within a stagnant plug. The plug is prone to tensile failure controlled by gas overpressure and tectonic stress, with failure most likely beneath the observed vent locations. We hence argue that Strombolian eruptions are related to plug failure rather than flow. Our proposed three‐phase model of the shallow plumbing system may provide a promising framework for integrating geophysical, petrological, and morphological observations at Stromboli and in open‐system volcanism more generally.

Suckale, J.↗

Monitoring and Modeling Caprock Integrity at the In Salah Carbon Dioxide Storage Site, Algeria

The In Salah gas development project, initiated in 2004, involves the long-term storage of waste carbon dioxide associated with natural gas production at several central Algerian fields. Rather then vent the extracted CO 2 into the atmosphere the operators, BP, Sonatrach, and Statoil chose to have the gas compressed, dehydrated, transported, and injected into a deep saline aquifer leg of the Krechba gas reservoir (Matheison et al. 2011). For this effort three horizontal state-of-the-art injection wells were drilled to a depth of 1500-1800m, using geo-steering technology to follow the roughly 20m thick reservoir. To maximize the injectivity, the wells were oriented perpendicular to the direction of maximum stress, the dominant fracture direction. Long-term plans were to store up to 17 million tonnes of carbon dioxide during the life of the program (Matheison et al. 2010). The project at In Salah was a pioneering effort in several respects and involved the investment of over 100 million dollars by the member companies. One feature that distinguishes In Salah from several other industrialscale CO 2 sequestration projects, such as Sleipner (Chadwick et al. 2012), Weyburn (White et al. 2011), Decatur (Kaven et al. 2014), and Aquastore (Worth et al. 2014) is the generally smaller storage volume in terms of overall reservoir thickness and lower average porosities of around 15%. With the exception of Weyburn, these other sites are characterized by generally thick sequences of high porosity sandstones. Therefore, one might expect that the pressure buildup near the wells could be larger at In Salah, with consequences for reservoir deformation and caprock strain. The role of fractures in providing storage and increasing reservoir permeability is one factor that would likely impact the pressure distribution around the well. However, the detailed effect of existing fractures on flow was not established prior to the injection at In Salah. The unique features of the In Salah storage site point to the importance of wellbore, geophysical, and geochemical monitoring to ensure that the integrity of the storage complex is maintained both during and after injection. In 2005 a Joint Industry Project (JIP) was set up, in an effort to use various geophysical, geochemical, and production techniques to monitor the fate of the injected carbon dioxide (Matheison et al. 2011). Here in this paper we describe the efforts made to monitoring the fate of the injected carbon dioxide, the state of the caprock, the estimated outcome of the storage effort, and some of the uncertainties that remain.

58 GEOSCIENCES↗

A Morphologically Stable Li/Electrolyte Interface for All-Solid-State Batteries Enabled by 3D-Micropatterned Garnet

Morphological degradation at the Li/solid-state electrolyte (SSE) interface is a prevalent issue causing performance fading of all-solid-state batteries (ASSBs). To maintain the interfacial integrity, most ASSBs are operated under low current density with considerable stack pressure, which significantly limits their widespread usage. In this work, a novel 3D-micropatterned SSE (3D-SSE) that can stabilize the morphology of the Li/SSE interface even under relatively high current density and limited stack pressure is reported. Under the pressure of 1.0 MPa, the Li symmetric cell using a garnet-type 3D-SSE fabricated by laser machining shows a high critical current density of 0.7 mA cm –2 and stable cycling over 500 h under 0.5 mA cm –2 . This excellent performance is attributed to the reduced local current density and amplified mechanical stress at the Li/3D-SSE interface. These two effects can benefit the flux balance between Li stripping and creep at the interface, thereby pre-venting interfacial degradation such as void formation and dendrite growth.

3D-micropatterned garnet↗

An Arduino based automatic pressure evaluation system to quantify growth of non‐model anaerobes in culture

Abstract Measuring the growth rate of non‐model anaerobic microbes typically requires the use of time‐consuming and often destructive manual measurements. Here, an Arduino based automatic pressure evaluation system (A‐APES) was developed to automatically measure the rate of fermentation gas production as a proxy for microbial growth in anaerobic systems. The A‐APES system measures accumulated gas pressure in sealed cultures accurately at high‐resolution, while venting the system at programmed intervals to prevent over pressurization. The utility of A‐APES is demonstrated in this study by quantifying the growth rate and phases of a biomass‐degrading anaerobic gut fungus, which cannot be otherwise measured via conventional techniques due to its association with particulate substrates. Given the utility of the A‐APES approach, we provide a complete construction guide to fabricate the device, which is three times less expensive compared to existing commercial alternatives.

Wilken, St. Elmo↗

Spatial mapping of dissolved methane using an in situ sensor in Puget Sound

Release of methane, as gas bubbles or in the dissolved phase, from the seafloor has been observed in coastal waters (< 200 m) and deep ocean basins (> 1000 m). Methane dissolution within the water column affects the geochemistry of the surrounding water, leading to localized oxygen loss and potential escape to the atmosphere, particularly from shallower sites. Traditional methods for detecting and quantifying dissolved methane rely on collecting discrete water samples for ship- or land-based ex situ analysis and post processing. Here, we report on the use of a reduced response time, in situ methane sensor, the Sensor for Aqueous Gases in the Environment (SAGE), for detecting and quantifying dissolved methane concentrations in a wide range of seafloor environments. During a Fall 2022 research cruise on the R/V Thomas G. Thompson in Puget Sound, SAGE was integrated onto a towed conductivity/temperature/depth rosette and deep-sea camera system with live-stream 1 Hz telemetry and used to spatially map the concentration of methane approximately 1 m above the seafloor. The site had been previously identified as an active methane plume field characterized by gas bubbles, fluid venting, and a faulted seabed. The widespread background dissolved concentration of methane measured by SAGE was 83 nM, and a range of 78–670 nM was observed throughout the survey. The results highlight the capacity of SAGE to map the spatial and temporal variability of dissolved methane concentrations in situ and to identify and localize sites of variable methane emissions from the seafloor.

Padilla, Alexandra M. [Woods Hole Oceanographic In↗

Implications of Underground Nuclear Explosion Cavity Evolution for Radioxenon Isotopic Composition

Abstract Isotopic ratios of radioxenons sampled in the atmosphere or subsurface can be used to verify the occurrence of an underground nuclear explosion (UNE). Differences in the half-lives of radioactive xenon precursors and their decay-chain networks produce different time-dependent concentration profiles of xenon isotopes allowing isotopic ratios to be used for tracking UNE histories including estimating the time of detonation. In this study, we explore the potential effects of post-detonation cavity processes: precipitation of iodine precursors, gas seepage, and prompt venting on radioxenon isotopic evolution which influences UNE histories. Simplified analytical models and closed-form solutions yielding a potentially idealized radioactive decay/ingrowth chain in a closed and well-mixed system typically have limited application by not including the partitioning of the radionuclide inventory between a gas phase and rock melt created by the detonation and by ignoring gas transport from the cavity to host rock or ground surface. In reality, either subsurface transport or prompt release that is principally responsible for gas signatures violates the closed-system (or batch-mode) assumption. A closed-form solution representing time-dependent source-term activities is extended by considering the cavity partitioning process, slow seepage, and/or prompt release of gases from the cavity and applied to realistic systems.

Sun, Yunwei (ORCID:0000000194801439)↗

Characterization of Archaeal Community in Contaminated and Uncontaminated Surface Stream Sediments

Abstract Archaeal communities from mercury and uranium-contaminated freshwater stream sediments were characterized and compared to archaeal communities present in an uncontaminated stream located in the vicinity of Oak Ridge, TN, USA. The distribution of the Archaea was determined by pyrosequencing analysis of the V4 region of 16S rRNA amplified from 12 streambed surface sediments. Crenarchaeota comprised 76% of the 1,670 archaeal sequences and the remaining 24% were from Euryarchaeota. Phylogenetic analysis further classified the Crenarchaeota as a Freshwater Group, Miscellaneous Crenarchaeota group, Group I3, Rice Cluster VI and IV, Marine Group I and Marine Benthic Group B; and the Euryarchaeota into Methanomicrobiales, Methanosarcinales, Methanobacteriales, Rice Cluster III, Marine Benthic Group D, Deep Sea Hydrothermal Vent Euryarchaeota 1 and Eury 5. All groups were previously described. Both hydrogen- and acetate-dependent methanogens were found in all samples. Most of the groups (with 60% of the sequences) described in this study were not similar to any cultivated isolates, making it difficult to discern their function in the freshwater microbial community. A significant decrease in the number of sequences, as well as in the diversity of archaeal communities was found in the contaminated sites. The Marine Group I, including the ammonia oxidizer Nitrosopumilus maritimus, was the dominant group in both mercury and uranium/nitrate-contaminated sites. The uranium-contaminated site also contained a high concentration of nitrate, thus Marine Group I may play a role in nitrogen cycle.

08 HYDROGEN↗