Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Utilities Power Change: Engaging Commercial Customers in Workplace Charging

Using electricity to power vehicles can help advance energy security and reduce emissions, and also presents a new market opportunity for utilities looking to diversify and offer an added benefit to commercial customers. By providing plug-in electric vehicle (PEV) charging stations for their employees, commercial customers can help attract and retain a cutting-edge workforce. These employers also signal a commitment to sustainability and demonstrate progressive leadership and a willingness to adopt advanced technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studies on the Effects of High Renewable Penetrations on Driving Point Impedance and Voltage Regulator Performance: National Renewable Energy Laboratory/Sacramento Municipal Utility District Load Tap Changer Driving Point Impedance Project

Voltage regulators perform as desired when regulating from the source to the load and when regulating from a strong source (utility) to a weak source (distributed generation). (See the glossary for definitions of a strong source and weak source.) Even when the control is provisioned for reverse operation, it has been observed that tap-changing voltage regulators do not perform as desired in reverse when attempting regulation from the weak source to the strong source. The region of performance that is not as well understood is the regulation between sources that are approaching equal strength. As part of this study, we explored all three scenarios: regulator control from a strong source to a weak source (classic case), control from a weak source to a strong source (during reverse power flow), and control between equivalent sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SEE Action Guide for States: Evaluation, Measurement, and Verification Frameworks$-$Guidance for Energy Efficiency Portfolios Funded by Utility Customers

This guide describes frameworks for evaluation, measurement, and verification (EM&V) of utility customer–funded energy efficiency programs. The authors reviewed multiple frameworks across the United States and gathered input from experts to prepare this guide. This guide provides the reader with both the contents of an EM&V framework, along with the processes used to develop and update these frameworks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DISTINCT: Diversity in Solar Talent Through INnovative Curriculum and Training: An Integrated Research and Education Approach towards Creating Diversity and Advancing Utility-Scale Solar Technology

The DISTINCT project research objective is to develop an innovative N-port power converter for a utility-scale PV system that is modular, compact and cost-effective and that will enable the integration of a high-frequency, high-voltage solid-state transformer. The novelty of the proposed research is the electrical power conversion architecture using an N-port converter system that replaces the output 60Hz transformer with an integrated high-frequency low-weight solid-state transformer reducing power electronics and BOS costs to meet SunShot goals through modularity and direct high-voltage interconnection. A challenge in direct integration with a 13.8kV line is the high voltage handling capacity of the converters combined with high efficiency operation. The front-end converter for each port is a Neutral-Point Clamped (NPC) Multi-Level dc-dc Dual-Active Bridge (ML-DAB) which allows Maximum Power Point Tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is an inverter with H-bridge configuration or NPC configuration. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e. 13.8 kV). The cascaded inverters have the inherent advantage of using lower rated devices, smaller filters and low Total Harmonic Distortion (THD) required for PV grid interconnection. Our analysis and simulation results show improved performance on cost, efficiency, service life with zero downtime and THD. A comprehensive control scheme is presented to ensure the maximum power from each port and each phase are sent to the grid. A functional prototype of a 2-port converter with ML-DAB and cascaded H-bridges has been designed, built, and tested in a laboratory setup to verify the target technical metrics. The N-port converter system due to its modular structure with individual control per port can be easily adapted to integrate functionalities that go well beyond the conventional grid support functions and mitigates impacts of forecasted fast ramp downs or ramp ups and single-fault conditions by automatic reconfiguration of the output.

14 SOLAR ENERGY↗

Materials and Fuels Complex West Campus Utility Corridor Preliminary Engineering Report

The current MFC wastewater system provides reliable and adequate disposal to the facilities within MFC; however, in anticipation of immediate and future growth, MFC desires to make upgrades to accommodate increased staffing levels and additional facilities at the complex. BEA has worked with J-U-B to evaluate the current wastewater system and to identify future improvements to the facility to provide wastewater service for future growth. This PER summarizes the improvements in accordance with Idaho Administrative Code IDAPA 58.01.16.411. These improvements are part of the MFC West Campus Utility Corridor project and consist of a new gravity collection system, pressurized forcemains, and a lift station.

42 ENGINEERING↗

What were the use patterns observed at the highly-utilized direct current fast charge sites?

This paper will examine the use of the most highly utilized DCFC units in the EV Project, and analyze the conditions under which the user elected to charge at those DCFCs. The DCFC stations examined for this paper had an average of 33 charge events per week. There were 20 DCFC stations that were used an average 20.8 to 66 times per week The user-based conditions evaluated for this paper include the battery’s indicated state-of-charge (SOC) at charge start, the distance away from home that the fast-charge took place, the day of the week that the PEV driver elected to fast-charge, and the time of day when the charge took place.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-economic Evaluation of Utility-Scale Power Plants Based on the Indirect sCO 2 Brayton Cycle - Report

This report presents the results of a techno-economic analysis (TEA) of a coal-fired utility scale power plant based on the indirect supercritical carbon dioxide (sCO 2 ) Brayton cycle using an oxy-fired circulating fluidized bed (CFB). A baseline plant configuration was examined as well as three variations to the sCO 2 power cycle examining the impact of reheat (Rht), main compressor intercooling (IC), and a combination of reheat and main compressor intercooling (RhtIC). Each plant configuration was assessed at two turbine inlet temperatures of 620 °C and 760 °C.

20 FOSSIL-FUELED POWER PLANTS↗

Techno-economic Evaluation of Utility-Scale Power Plants Based on the Indirect sCO2 Brayton Cycle - Presentation

This presentation discusses the results of a techno-economic analysis (TEA) of a coal-fired utility scale power plant based on the indirect supercritical carbon dioxide (sCO2) Brayton cycle using an oxy-fired circulating fluidized bed (CFB). A baseline plant configuration was examined as well as three variations to the sCO2 power cycle examining the impact of reheat (Rht), main compressor intercooling (IC), and a combination of reheat and main compressor intercooling (RhtIC). Each plant configuration was assessed at two turbine inlet temperatures of 620 °C and 760 °C.

Brayton power cycle↗

Evaluating Utility Costs Savings for EV Charging Infrastructure [Slides]

This analysis was conducted under the first round of the Solar Energy Innovation Network (SEIN), a program led by the National Renewable Energy Laboratory (NREL) that assembles diverse teams of stakeholders to research solutions to real-world challenges associated with solar energy adoption. As part of the Solar Energy Innovation Network, NREL used a tool called REopt to evaluate the impact on utility costs of light duty electric vehicle (EV) charging stations in Minnesota. The analysis models EV chargers at medium offices in Minneapolis, Minnesota. Specifically, the analysis explores three questions: (a) How can photovoltaics (PV) and stationary storage be co-deployed with EV charging infrastructure to lower the cost of purchasing grid electricity? (b) What are the potential savings of co-locating EV charging infrastructure with (behind the meter of) a commercial building? and (c) What savings can be gained from optimizing the times at which the EVs are charged to decrease lifecycle costs? Note that this presentation is not indented to be presented widely, but is just to provide ReOpt outputs for the partner's use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Applying Non-Energy Impacts from Other Jurisdictions in Cost-Benefit Analyses of Energy Efficiency Programs: Resources for States for Utility Customer-Funded Programs

Avoided energy and capacity costs are the primary yardstick utilities use to determine which energy efficiency programs are cost-effective for their customers. But sometimes "non-energy impacts" — not commonly recognized as directly associated with energy generation, transmission and distribution — represent substantial benefits, such as improving comfort, air quality and public health. Considering whether and how to include non-energy impacts is an important part of cost-benefit analyses for these programs. This report offers practical considerations for deciding which non-energy impacts to include and how to apply values or methods from other jurisdictions. Researchers reviewed studies quantifying non-energy impacts used in 30 states and applied a five-point system to indicate transferability of a value or method from each study for 16 categories of non-energy impacts: Water resource costs and benefits; Other fuels costs and benefits; Avoided environmental compliance costs; Environmental impacts; Productivity; Health and safety; Asset value; Energy and/or capacity price suppression effects; Avoided costs of compliance with Renewable Portfolio Standard requirements; Avoided credit and collection costs; Avoided ancillary services; Comfort; Economic development and job impacts; Public health impacts; Energy security impacts; Increased reliability. The U.S. Department of Energy’s Building Technologies Office supported this work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Process Intensification for Electrochemical Utilization of CO 2

The conversion of CO 2 to value-added products is an attractive approach for reducing the cost of CO 2 capture. Formic acid (FA) is a multipurpose industrial chemical feedstock for formic acid fuel cells, additives in the textile and agricultural sectors, cleaning products, and corrosion inhibitors. FA can be produced directly from CO 2 via a two-electron process facilitated with DC electricity supplied via renewable/intermittent power sources [1]. The state-of-the-art method for industrial FA production is the Kemira process, which uses methanol, sodium methoxide, and CO to produce methyl formate that is subsequently hydrolyzed to formic acid. Conversely, an electrochemical approach reduces the number of chemical input for FA production, but conventional electrochemical processes for CO 2 reduction to FA continue to suffer from selectivity issues where the electrocatalyst produces a wide range of products. These competing products include FA, hydrogen, carbon monoxide, methanol, and methane that reduce faradaic efficiency by up to 50% [2]. The CAER-Andora process features an enzymatic catalyst with high selectivity for FA production with turn-over-frequency >85 s-1. The CAER-Andora process combines an electrochemical cell that features graphite electrodes and an electrochemically facile charge mediator, combined with an immobilized proprietary catalyst inside a FA production cell. These processes work together to 1) reduce faradaic inefficiencies by producing only FA, 2) protect the valuable catalyst from deactivation by overpotentials, and 3) provide a modular system configuration that facilitates independent optimization of the electrochemical and production cells. Operating at <3 V, the CAER-Andora process currently produces ~1 mM FA/hour with >90% CO2 to FA conversion in the production cell, and progress towards the intensification of the CO 2 utilization process will be discussed.

20 FOSSIL-FUELED POWER PLANTS↗

Implications of a regional resource adequacy program on utility integrated resource planning: Study for the Western United States

LBNL collaborated with the Western Interstate Energy Board and the University of Texas, Austin to investigate the implications of a regional resource adequacy (RA) program on utility integrated resource planning. This report is focused on an active policy discussion to develop a novel voluntary program to share capacity resource and improve RA in the Western Interconnection. This report identifies two RA components of IRP that will be highly impacted by a regional RA program: resource capacity accreditation and RA targets. There are at least four resources that will require specific attention for their capacity credit calculation: (1) variable renewable resources, (2) demand-side resources, (3) hydropower, and (4) contracts. It will then be necessary to decide on a RA target reliability metric (e.g., a planning reserve margin) that is at least the minimum requirement in IRPs to ensure consistency in RA requirement calculations. The report finds that load forecasting and transmission expansion analyses will be moderately impacted, but that most of IRP components will not be significantly impacted. The report includes (i) a review of traditional resource adequacy practices in IRP; (ii) a case study of an existing regional RA program that interacts with IRP (Southwest Power Pool) and (iii) an overview of the NWPP regional resource adequacy proposal that is the object of this work. This paper does not (1) advocate for or against a regional RA program for the NWPP, (2) make detailed design recommendations for this program, or (3) assess its benefits and costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Policy and Regulatory Environment for Utility-Scale Energy Storage: India

This report is part of a series investigating the potential for utility-scale energy storage in South Asia. The first part of the work is focused on opportunities and barriers for energy storage within existing policy and regulatory frameworks in the region. This report applies the previously-developed Energy Storage Readiness Assessment to evaluate the policy and regulatory environment for energy storage in India. Forthcoming reports will expand this analysis to other countries in South Asia. These evaluations are designed to provide insights on the opportunities and barriers for energy storage growth and deployment in each country. The second part of this work consists of techno-economic analysis to understand the drivers of energy storage investments in South Asia. Using NREL’s power system planning and operational models of South Asia, this analysis will identify potential storage applications and growth under various cost, policy, and demand growth scenarios. In addition, the regulatory and policy barriers and incentive mechanisms identified in the first task will be incorporated into the modeling task to understand their impact on energy storage deployment and operation. Together these studies will inform the applications and value of energy storage on South Asia power systems and policy and regulatory pathways to realize this value.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Universal Utility Data Exchange (UUDEX) - Workflow Design - Rev 1

This workflow design document describes the process of establishing a Universal Utility Data Exchange (UUDEX) Connection between two or more UUDEX Endpoints. The existing processes required to establish a data link using Inter Control Center Communications Protocol (ICCP) are very time consuming, from both the perspectives of effort and calendar time. The intent of UUDEX is to provide a more streamlined alternative. The UUDEX Workflow is also used to establish UUDEX Connections to exchange data other than that found in traditional ICCP data exchanges such as exchanges of power system model files, security events and mitigations, disturbance reports, and market data.

97 MATHEMATICS AND COMPUTING↗

Barriers to Broader Utilization of Fault Detection Technologies for Improving Residential HVAC Equipment Efficiency

Faults in residential heating, ventilating, and air conditioning (HVAC) equipment may occur due to poor installation practices or develop over time, and these faults can negatively impact system efficiency, thermal comfort, and equipment lifespan. Automated fault detection and diagnostic (AFDD) technologies identify energy wasting HVAC faults, such as low indoor airflow and improper refrigerant charge, and guide technicians in improving system efficiency. For residential HVAC, AFDD consists of a range of fault detecting and diagnostic capabilities, sensor configurations, and target applications. AFDD technology can either be permanently installed by the original equipment manufacturer (OEM) using embedded sensors or as an add-on product either during or after installation. Additionally, several advanced installation tools and refrigerant gauge sets include AFDD features for temporary use during equipment installation and tune-ups. Some technologies can detect a fault but have limited diagnostic capabilities. For example, a single-point measurement from the home's thermostat or energy monitor can provide certain fault detection capability by analyzing the equipment runtime or energy consumption. These technologies, though limited at determining the cause of a given fault, may have significant energy savings potential due to their low cost and prevalence in the residential HVAC market. Despite the potential benefits, fault detection technologies face many technical and market barriers preventing broad adoption. Beyond the cost barriers due to the added sensor requirements and technology development, fault detection technologies face many implementation and adoption barriers such as installer training, customer awareness, standardized communication protocols, and methods of test for evaluating accuracy. The purpose of this whitepaper is to characterize market and technical barriers impeding broader utilization of fault detection technology for residential HVAC energy efficiency applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Universal Utility Data Exchange (UUDEX) Phase 4 Demonstration Environment and Results

This report provides an overview of the environment used by the Pacific Northwest National Laboratory (PNNL) in the Universal Utility Data Exchange (UUDEX) Phase 4 demonstration, and description of the demonstrations performed in the environment. The UUDX Phase 4 demonstration took place on March 31, 2021, with representatives from PNNL and the two project sub-contractors, OATI and MITRE, performing the demonstration for members of the UUDEX Industry Advisory Board (IAB). The demonstration tasks were based on the previous Phase 3 demonstration but conducted in a multi-site environment. Additional demonstrations showed features that were developed since the Phase 3 demonstration. The development environment was constructed by PNNL programming staff using the previously developed UUDEX Functional Design, Protocol Design, and Workflow Design documents as a starting point. The environment was augmented with subject creation management and access control security data structures and workflows, and data exchange structure documents developed as part of Phase 3 and Phase 4.

97 MATHEMATICS AND COMPUTING↗