Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transformers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Increased Agrobacterium-mediated transformation and rooting efficiencies in canola (Brassica napus L.) from hypocotyl segment explants

An efficient protocol for the production of transgenic Brassica napus cv. Westar plants was developed by optimizing two important parameters: preconditioning time and co-cultivation time. Agrobacterium tumefaciens-mediated transformation was performed using hypocotyls as explant tissue. Two variants of a green fluorescent protein (GFP)-encoding gene--mGFP5-ER and eGFP--both under the constitutive expression of the cauliflower mosaic virus 35S promoter, were used for the experiments. Optimizing the preconditioning time to 72 h and co-cultivation time with Agrobacterium to 48 h provided the increase in the transformation efficiency from a baseline of 4% to 25%. With mGFP5-ER, the transformation rate was 17% and with eGFP it was 25%. Transgenic shoots were selected on 200 mg/l kanamycin. Rooting efficiency was 100% on half-strength Murashige and Skoog medium with 10 g/l sucrose and 0.5 mg/l indole butyric acid in the presence of kanamycin.

NASA Discipline Life Sciences Technologies↗

Cereal transformation through particle bombardment

The review focuses on experiments that lead to stable transformation in cereals using microprojectile bombardment. The discussion of biological factors that affect transformation examines target tissues and vector systems for gene transfer. The vector systems include reporter genes, selectable markers, genes of agronomic interest, and vector constructions. Other topics include physical parameters that affect DNA delivery, selection of stably transformed cells and plant regeneration, and analysis of gene expression and transmission to the progeny.

NASA Discipline Plant Biology↗

Effect of track structure and radioprotectors on the induction of oncogenic transformation in murine fibroblasts by heavy ions

The oncogenic potential of high-energy 56Fe particles (1 GeV/nucleon) accelerated with the Alternating Gradient Synchrotron at the Brookhaven National Laboratory was examined utilizing the mouse C3H 10T1/2 cell model. The dose-averaged LET for high-energy 56Fe is estimated to be 143 keV/micrometer with the exposure conditions used in this study. For 56Fe ions, the maximum relative biological effectiveness (RBEmax) values for cell survival and oncogenic transformation were 7.71 and 16.5 respectively. Compared to 150 keV/micrometer 4He nuclei, high-energy 56Fe nuclei were significantly less effective in cell killing and oncogenic induction. The prostaglandin E1 analog misoprostol, an effective oncoprotector of C3H 10T1/2 cells exposed to X rays, was evaluated for its potential as a radioprotector of oncogenic transformation with high-energy 56Fe. Exposure of cells to misoprostol did not alter 56Fe cytotoxicity or the rate of 56Fe-induced oncogenic transformation.

NASA Discipline Radiation Health↗

The Effect Stacking Fault Segregation and Phase Transformations have on Creep Strength in Ni-based Superalloys

In this study, two commercially similar polycrystalline Ni-based disk superalloys (LSHR and ME3) were creep tested at 760C and 552MPa to approximately 0.3% plastic strain. LSHR consistently displayed superior creep properties at this stress/temperature regime even though the microstructural characteristics between the two alloys were comparable. High resolution structural and chemical analysis, however, revealed significant differences between the two alloys among active gamma prime shearing modes involving superlattice intrinsic and extrinsic stacking faults. In ME3, Co and Cr segregation and Ni and Al depletion were observed along the intrinsic faults - revealing a gamma prime -to- gamma phase transformation. Conversely in LSHR, an alloy with a higher W content, Co and W segregation was observed along the intrinsic faults. This observation combined with scanning transmission electron microscopy (STEM) simulations confirm a gamma prime-to-D019 phase transformation along the intrinsic faults in LSHR. Using experimental observations and density functional theory calculations, a novel local phase transformation strengthening mechanism is proposed that could be further utilized to improve the high temperature creep capabilities of Ni-base disk alloys.

Superalloy↗

Integrated Computational Materials Engineering (ICME) Capability Maturity Levels for Ecosystems Enabling Digital Transformation

Digital engineering (DE) and integrated computational materials engineering (ICME) are widely recognized as critical enablers of faster, more affordable, and more reliable aerospace systems. However, many organizations have struggled to realize the promised return on investment (ROI) from digital initiatives. A primary reason is the absence of a shared, decision-focused framework that distinguishes simple digitization of existing workflows from true digital transformation that fundamentally changes how engineering decisions are made. This paper introduces an ICME capability maturity framework that fills this gap. The framework defines six cumulative ICME capability maturity levels (CMLs), explicitly tied to decision authority, engineering integration, optimization, and uncertainty management across material, process, structure, and performance scales. It is designed to complement established readiness metrics such as technology readiness levels (TRLs), manufacturing readiness levels (MRLs), and integration readiness levels (IRLs), by addressing a missing dimension: the conditions required for model-informed decision authority across scales. A unifying figure and capability table illustrate the six-level ICME Capability Maturity Framework, showing how organizations progress from digitization—with limited or negative ROI—to true digital transformation, where ICME-enabled workflows deliver measurable improvements in decision quality, cycle time, risk reduction, and reuse. The framework is intended for both technical practitioners and executive leadership, providing a common language to assess current state, guide roadmaps, align software ecosystem investments, and set realistic expectations for digital transformation outcomes. A regulatory-relevant statement clarifying the relationship between ICME capability and existing certification frameworks is provided.

ICME↗

Dynamic-Phasor Model of Transformer Inrush Simulation for Unbalanced Distribution System

Abstract— Power system stability is a critical concern, with respect to the increasing distributed energy resources, microgrids, and emphasis on enhancing resiliency. For stability analysis and evaluation, modeling and simulation capabilities are important. In this paper, the authors’ previous work on modeling transformer inrush dynamics is improved with a new formulation of the key equation that converts the dynamic-phasor into real-time value. Simulation results in an electromechanical time-scale are compared with PSCAD results in an electromagnetic time-scale to demonstrate the improvement. The impact of simulation step size is discussed. A bug in PSCAD transformer setting that leads to incorrect magnetizing flux and current under Delta winding type is identified and reported. In addition, explanations and analysis are provided on two modeling techniques utilized since the previous work. This work is being incorporated into the next release of GridLAB-D. The improved transformer inrush calculation enables more accurate predictions of current amplitudes for analyzing the dynamics of distribution operation and control.

power transformers, power system simulation, satur↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems: Preprint

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

New Transformer Testing Approach Reduces Reactor Down Time

The ATR-774 transformer yard has been in operation for 57 years. It's old, outdated, and reaching end of life. Plant health has decided to construct a new transformer yard, which will require testing. I've explored the standards library and compiled a list of tests that need to be performed on the transformer yard. This effort led to a significant speed-up in the testing process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seismic Resilience of Large Power Transformer Bushings & Non-SF6 Industrial Base Scan Review

Large (high voltage) power transformers (LPT), and more specifically, their bushings, are known to be susceptible to seismic failure. With bushing failure, a transformer will have to be replaced, which has a considerable lead time, adding to the power outage duration. Cost-efficient, proven solutions are not currently available to mitigate this risk, which can persist for the more than 30-year life of a particular transformer. This work will focus on developing and demonstrating a hardware solution to address seismic vulnerabilities and reduce outage risks from LPT failure. Sulfur Hexafluoride (SF6) is a specialty gas with excellent electrical insulation properties which has been used extensively in the power industry. This gas is unfortunately also one of the most potent greenhouse gases known to humanity. A 2014 report by the Intergovernmental Panel on Climate Change found that SF6 has a global warming potential (GWP) 23,000 times higher than Carbon Dioxide, and has the highest GWP of all gases assessed (Myhre 2013). SF6 is almost exclusively man-made and is produced for use as an insulator in high voltage electrical equipment. This makes the production and use of SF6 one of the leading sources of anthropogenic climate change. To fully eliminate the environmental impacts of SF6, alternative technology is needed. The ideal replacement would be a technology that can fulfil the same role as SF6, at the same cost or cheaper, but without adverse environmental effects. Currently, no technology fits this description, however several promising technologies have begun to enter the market. An industry scan was performed to assess the state of industry adoption and manufacturing capability for SF6-free alternative technologies for use at the high-voltage level, and the primary barriers to broader adoption.

10 SYNTHETIC FUELS↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

Stacked Low-Inertia Converter or Solid-State Transformer: Modeling and Model Predictive Priority-Shifting Control for Voltage Balance

This paper presents control challenges of stacked low-inertia converter (SLIC) or cascaded reduced dc-link solid-state transformer (SST) and proposes a novel model predictive priority-shifting (MPPS) control with implicit modulator and a discrete-time large-signal model for voltage balancing and dc-link regulation. Low-inertia converters, featuring small electrolytic capacitor-less dc links, dramatically reduce cost, size, and weight compared to conventional solutions. However, without a large dc-link buffer, the input and output are tightly coupled, leading to significant control challenges. The control becomes even more challenging with these converters stacked input-series output-parallel (ISOP) for medium-voltage (MV) grid, which causes coupling between the modules besides the coupling within each module. This paper analyzes the multi-objective, multi-degree of freedom control problem, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. First, distribution of control efforts under controller saturation is critical because multiple control objectives can be conflicting, especially when the module voltages are unbalanced and are being restored. The MPPS can shift the priorities to address this issue. Second, due to the low inertia and high dc-link ripple, classic space vector pulse-width modulation (SVPWM), average model with small-ripple assumption, and control design based on small-signal model cannot accurately modulate, model, and control the nonlinear reduced dc link. Therefore, a discrete-time large-signal model of the M-S4T is established to derive the predictive control in the MPPS. The MPPS and the PI control are compared in MV simulations to show the issue of applying the PI to the SLIC and the effectiveness of the MPPS for voltage balancing and dc-link regulation in a deadbeat manner. Finally, the proposed control is tested on a 5 kV ISOP SiC SST prototype to verify priority shifting to address controller saturation issue and fast and robust voltage balancing.

14 SOLAR ENERGY↗

DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer

This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.

14 SOLAR ENERGY↗

Grid Ready, Flexible Large Power Transformer

GE Research and its partner Prolec GE have proposed a novel and breakthrough concept to improve the flexibility and interchangeability of large power transformers (LPTs). LPTs refer in this report to transformers with a power rating equal or greater than 100 MVA. The concept consists of a 3-phase autotransformer bank having one specified high voltage side (HV) voltage and three configurable low voltage side (LV) voltage taps. Moreover, the leakage impedance is adjustable offline using taps which allows to accommodate short-circuit requirements for a wide range of LPTs applications. The research performed aimed to develop and validate a cost-effective design of a flexible LPT and to demonstrate its competitiveness with the LPT fleet currently in operation in the U.S. The concept is intended for the long-term replacement of existing LPTs. In this project, the U.S based population of LPTs was analyzed to determine their commonality in power, voltage classes, and impedance range. Up to 9,700 units, currently deployed in the NERC’s Eastern and Western interconnection regions, were evaluated. This analysis yielded the specifications of two flexible LPTs to be designed to demonstrate the manufacturability and competitiveness of the concept: a 345 kV, 230 MVA and a 230 kV, 100 MVA LPTs. The two LPTs are both configurable to 161 kV, 138 kV, and 115 kV on the LV side and allow leakage impedance variation between 4% and 14%. The design output showed that the flexible LPT is manufacturable and competitive with conventional LPT. The proposed design has a power efficiency of 99.5% and a total active part weight increase ranging only between 15% and 28% relative to conventional LPTs it can be substituted with. Indeed, for the flexible LPT, the higher the LV side voltage is, the higher is its power rating. Hence, flexible LPTs are more competitive when compared with the largest conventional LPT they can replace. Power systems analyses were carried out to evaluate the performance of the flexible LPT when replacing an existing conventional LPT. These analyses showed that short-circuit and inrush currents will remain respectively within 15% and 9.4% of their original levels suggesting that no substations equipment is likely to be replaced due the installation of the flexible LPT. In addition, the analyses showed that the transient overvoltage anticipated at the impedance configuration switch will be manageable and will not pose any particular risk during lightning or switching events. This research proved that the deployment of flexible LPTs in the U.S power grid can greatly improve the grid reliability and its resiliency especially in the event of the loss of multiple LPTs. Moreover, the concept can significantly help reduce LPTs’ spare inventory by providing a high spare coverage level. The performed analysis showed that the designed 345 kV flexible LPT can serve as a spare for up to 34 units currently in operation in the U.S while the designed 230 kV flexible LPT can replace up to 101 units. Flexible LPTs offer new opportunities to U.S utilities to improve interchangeability of LPTs in the transmission system and to better strategize the upcoming renewal of about 70% of the population of LPTs anticipated to retire within the next two decades.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA Enterprise Digital Transformation Initiative Strategic Framework & Implementation Approach

Since 1958, NASA has delivered its enduring bold purpose, characterized in the 2022 NASA Strategic Plan as a mission to discover, explore, innovate, and advance solutions to the problems of flight, within and outside the Earth’s atmosphere, for the benefit of humankind. The NASA Strategic Plan also recognizes that this mission will be delivered differently as it looks to a future marked by radical global change, which is in part being driven by digital advances. For this reason, in late 2020 NASA established an Enterprise Digital Transformation (DT) agency-level strategic initiative to accelerate and coordinate leveraging digital advances to transform the way the Agency works, the experience of its workforce and the agility of its workplace. This paper documents NASA’s DT strategic framework and associated implementation approach, with the DT strategic initiative serving to ignite, connect, integrate, and facilitate DT progress across a federated organizational operating model.

digital transformation↗

Phase Transformation Contributions to Heat Capacity and Impact on Thermal Diffusivity, Thermal Conductivity, and Thermoelectric Performance

Abstract The accurate characterization of thermal conductivity κ, particularly at high temperature, is of paramount importance to many materials, thermoelectrics in particular. The ease and access of thermal diffusivity D measurements allows for the calculation of κ when the volumetric heat capacity, ρc p , of the material is known. However, in the relation κ = ρc p D , there is some confusion as to what value of c p should be used in materials undergoing phase transformations. Herein, it is demonstrated that the Dulong–Petit estimate of c p at high temperature is not appropriate for materials having phase transformations with kinetic timescales relevant to thermal transport. In these materials, there is an additional capacity to store heat in the material through the enthalpy of transformation Δ H . This can be described using a generalized model for the total heat capacity for a material where φ is an order parameter that describes how much latent heat responds “instantly” to temperature changes. Here, C pφ is the intrinsic heat capacity (e.g., approximately the Dulong–Petit heat capacity at high temperature). It is shown experimentally in Zn 4 Sb 3 that the decrease in D through the phase transition at 250 K is fully accounted for by the increase in c p , while κ changes smoothly through the phase transition. Consequently, reports of κ dropping near phase transitions in widely studied materials such as PbTe and SnSe have likely overlooked the effects of excess heat capacity and overestimated the thermoelectric efficiency, zT .

Agne, Matthias T.↗

Understanding Strain‐Induced Phase Transformations in BiFeO 3 Thin Films

Experiments demonstrate that under large epitaxial strain a coexisting striped phase emerges in BiFeO 3 thin films, which comprises a tetragonal‐like ( T ′) and an intermediate S ′ polymorph. It exhibits a relatively large piezoelectric response when switching between the coexisting phase and a uniform T ′ phase. This strain‐induced phase transformation is investigated through a synergistic combination of first‐principles theory and experiments. The results show that the S ′ phase is energetically very close to the T ′ phase, but is structurally similar to the bulk rhombohedral ( R ) phase. By fully characterizing the intermediate S ′ polymorph, it is demonstrated that the flat energy landscape resulting in the absence of an energy barrier between the T ′ and S ′ phases fosters the above‐mentioned reversible phase transformation. This ability to readily transform between the S ′ and T ′ polymorphs, which have very different octahedral rotation patterns and c / a ratios, is crucial to the enhanced piezoelectricity in strained BiFeO 3 films. Additionally, a blueshift in the band gap when moving from R to S ′ to T ′ is observed. These results emphasize the importance of strain engineering for tuning electromechanical responses or, creating unique energy harvesting photonic structures, in oxide thin film architectures.

36 MATERIALS SCIENCE↗

Quantification of High‐Temperature Transition Al 2 O 3 and Their Phase Transformations**

Abstract High‐temperature treatment of γ‐Al 2 O 3 can lead to a series of polymorphic transformations, including the formation of δ‐Al 2 O 3 and θ‐Al 2 O 3 . Quantification of the microstructure in the range where δ‐ and θ‐Al 2 O 3 are formed represents a formidable challenge, as both phases accommodate a high degree of structural disorder. In this work, we explore the use of an XRD recursive‐stacking formalism for the quantification of high‐temperature transition aluminas. We formulate the recursive‐stacking methodology for modelling of disorder in δ‐Al 2 O 3 and twinning in θ‐Al 2 O 3 and show that explicitly accounting for the disorder is necessary to reliably model the XRD patterns of high‐temperature transition alumina. We also use the recursive stacking approach to study phase transformation during high‐temperature (1050 °C) treatment. We show that the two different intergrowth modes of δ‐Al 2 O 3 have different transformation characteristics and that a significant portion of δ‐Al 2 O 3 is stabilized with θ‐Al 2 O 3 even after prolonged high‐temperature exposures.

Kovarik, Libor↗

Morphogenic Regulator-Mediated Transformation of Maize Inbred B73

Maize B73 is a reference genome and has long been a major resource for genetics and molecular biology research. We have developed an efficient B73 transformation protocol by enabling somatic embryogenesis through differential co-expression of maize morphogenic regulators BBM and WUS2. We describe a successful protocol that utilizes Agrobacterium tumefaciens strain AGL1 harboring binary vector PHP78891 that comprises a BBM and WUS2 expression cassette as well as a green fluorescent protein (GFP) reporter cassette. The PHP78891 vector also contains, within the T-DNA region, a CRE/lox recombination system flanking the CRE/BBM/WUS2 co-expression cassette driven by the desiccation inducible RAB17 promoter that allows removal of the BBM/WUS2 cassette. Introduction and co-expression of BBM and WUS2 induced direct somatic embryogenesis (SE) in non-regenerable maize B73 from immature embryo explants. Removal of the CRE/BBM/WUS2 cassette is essential to allow regeneration to fertile plants. The GFP expression cassette outside the lox excision sites is retained in the transgenic plant genome, allowing subsequent phenotypic analysis of calli and regenerated transgenic events. This transformation system enables a selectable marker-free transformation process by taking advantage of BBM/WUS2-induced SE as a developmental selection system.

59 BASIC BIOLOGICAL SCIENCES↗