Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TREAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Vacuum Hold-Down System for Heat-Treating Thin Films

In improved furnace concept for heat-treating thin films, vacuum ports in vacuum plate(s) hold films connected together in zones so vacuum applied separately to each zone. Allows material being held to shrink or expand while still being held in place. Unclamped zones expand or contract , relieving local stresses so entire sheet accommades thermally induced changes without cracking. Applications include manufacture of thin semiconductor films for solar cells and of membranes for electrolytic production of oxygen.

Collins, Earl R., Jr.↗

Simulated flight acoustic investigation of treated ejector effectiveness on advanced mechanical suppresors for high velocity jet noise reduction

Ten scale-model nozzles were tested in an anechoic free-jet facility to evaluate the acoustic characteristics of a mechanically suppressed inverted-velocity-profile coannular nozzle with an accoustically treated ejector system. The nozzle system used was developed from aerodynamic flow lines evolved in a previous contract, defined to incorporate the restraints imposed by the aerodynamic performance requirements of an Advanced Supersonic Technology/Variable Cycle Engine system through all its mission phases. Accoustic data of 188 test points were obtained, 87 under static and 101 under simulated flight conditions. The tests investigated variables of hardwall ejector application to a coannular nozzle with 20-chute outer annular suppressor, ejector axial positioning, treatment application to ejector and plug surfaces, and treatment design. Laser velocimeter, shadowgraph photograph, aerodynamic static pressure, and temperature measurement were acquired on select models to yield diagnositc information regarding the flow field and aerodynamic performance characteristics of the nozzles.

Brausch, J. F.↗

Significant long-term reduction in n-channel MESFET subthreshold leakage using ammonium-sulfide surface treated gates

Ammonium-sulfide (NH4)2S treated gates have been employed in the fabrication of GaAs MESFETs that exhibit a remarkable reduction in subthreshold leakage current. A greater than 100-fold reduction in drain current minimum is observed due to a decrease in Schottky gate leakage. The electrical characteristics have remained stable for over a year during undesiccated storage at room temperature, despite the absence of passivation layers.

Neudeck, P. G.↗

Shock-treated Lunar Soil Simulant: Preliminary Assessment as a Construction Material

In an effort to examine the feasibility of applying dynamic compaction techniques to fabricate construction materials from lunar regolith, preliminary explosive shock-loading experiments on lunar soil simulants were carried out. Analysis of our shock-treated samples suggests that binding additives, such as metallic aluminum powder, may provide the necessary characteristics to fabricate a strong and durable building material (lunar adobe) that takes advantage of a cheap base material available in abundance: lunar regolith.

Boslough, Mark B.↗

Round Heat-treated Chromium-molybdenum-steel Tubing Under Combined Loads

The results of tests of round heat-treated chromium-molybdenum-steel tubing are presented. Tests were made on tubing under axial load, bending load, torsional load, combined bending and axial load, combined bending and torsional load, and combined axial, bending, and torsional load. Tensile and compressive tests were made to determine the properties of the material. Formulas are given for the evaluation of the maximum strength of this steel tubing under individual or combined loads. The solution of an example is included to show the procedure to be followed in designing a tubular cantilever member to carry combined loads.

Osgood, William R↗

Fundamental Effects of Aging on Creep Properties of Solution-Treated Low-Carbon N-155 Alloy

A method is developed whereby the fundamental mechanisms are investigated by which processing, heat treatment, and chemical composition control the properties of alloys at high temperatures. The method used metallographic examination -- both optical and electronic --studies of x-ray diffraction-line widths, intensities, and lattice parameters, and hardness surveys to evaluate fundamental structural conditions. Mechanical properties at high temperatures are then measured and correlated with these measured structural conditions. In accordance with this method, a study was made of the fundamental mechanism by which aging controlled the short-time creep and rupture properties of solution-treated low-carbon n-155 alloy at 1200 degrees F.

Frey, D N↗

Influence of Chemical Composition on Rupture Properties at 1200 Degrees F. of Forged Chromium-Cobalt-Nickel-Iron Base Alloys in Solution-Treated and Aged Condition

The influence of systematic variations of chemical composition on rupture properties at 1200 degrees F. was determined for 62 modifications of a basic alloy containing 20 percent chromium, 20 percent nickel, 20 percent cobalt, 3 percent molybdenum, 2 percent tungsten, 1 percent columbium, 0.15 percent carbon, 1.7 percent manganese, 0.5 percent silicon, 0.12 percent nitrogen and the balance iron. These modifications included individual variations of each of 10 elements present and simultaneous variations of molybdenum, tungsten, and columbium. Laboratory induction furnace heats were hot-forged to round bar stock, solution-treated at 2200 degrees F., and aged at 1400 degrees F. The melting and fabrication conditions were carefully controlled in order to minimize all variable effects on properties except chemical composition. Information is presented which indicates that melting and hot-working conditions play an important role in high-temperature properties of alloys of the type investigated.

Reynolds, E E↗

In-plant testing of membranes to treat electroplating wastewater

This is the final report submitted for the work performed under the NASA Cooperative Agreement NCC3-301 for the project entitled 'In-Plant Testing of Membranes To Treat Electroplating Waste water'. The main objective of the research project was to determine if the crosslinked polyacrylic acid salt films developed by NASA scientists could be used for heavy metal removal from the wastewater generated by the metals-finishing or electroplating industry. A variety of tasks identified in the original proposal were completed. These included: (1) analysis of our industrial partner Aetna Plating's zinc electroplating process and its wastewater treatment needs for zinc removal; (2) design and construction of a laboratory-scale unit to continuously supply and remove the ion exchange films from the zinc wastewater; (3) performance of a series of runs on such a unit to determine its operating characteristics; and (4) design of a prototype unit for use at the industrial site. In addition, there were a number of tasks that had not been identified in the original proposal but were later judged to be necessary for the successful completion of the project. These were: (1) batch equilibrium and kinetic experiments with analysis of the experimental results to accurately determine the equilibrium and kinetic parameters for the ion exchange films; (2 ) simulation studies for proper design of the prototype unit; and (3) preliminary runs to exchange the films from H form to Calcium form.

Shah, D. B.↗

X-ray Photoelectron Spectroscopy Study of Argon-Plasma-Treated Fluoropolymers

Films of poly(tetrafluoroethylene) (PTFE) and of a tetrafluoroethylene-perfluoroalkyl vinyl ether (approximately 49:1) copolymer (PFA) were exposed to a radio-frequency argon plasma and then examined by X-ray photoelectron spectroscopy (XPS). The use of fluoropolymer films nearly free of surface hydrocarbon contamination as well as the use of a monochromatized X-ray source for XPS removed two factors contributing to conflicting reports on the effect of exposure time on the fluorine-to-carbon (F/C) and oxygen-to-carbon (O/C) ratios for several Ar-plasma-treated fluoropolymers. Contrary to literature indications, a common pattern was found for PTFE and PFA: a moderate decrease in F/C ratio (from 1.99 to 1.40, and from 1.97 to 1.57, respectively), together with a moderate increase in O/C ratio (from negligible to about 0.10, and from 0.012 to about O.10, respectively) at very short exposures, after which the F/C ratios remained essentially constant on prolonged exposures, while the O/C ratios for PTFE and PFA leveled off at 0.11 and 0.15, respectively. The XPS C(sub 1s), spectra for these polymers exposed to the Ar plasma for 20 min were similar and presented, besides a prominent peak at 292.0 eV (CF2,) and a minor peak at 294.0 or 294.1 eV (CF3), a composite band of four curve-resolved peaks (approximately 285-290 eV) representing various CH, CC, CO, CN, and CF functionalities.

Golub, Morton A.↗

A Comparison of Cilostazol and Pentoxifylline for Treating Intermittent Claudication

A randomized, double-blind, placebo-controlled, parallel-group, phase III multicenter trial was performed to evaluate the relative efficacy and safety of cilostazol and pentoxifylline. The study included 54 outpatient vascular clinics, including sites at Air Force, Veterans Affairs, tertiary care, and university hospitals in the United States. Of 922 consenting patients, 698 met the inclusion criteria, were randomized, and received treatment with either cilostazol 100 mg P0 twice a day, pentoxifylline 400 mg PO 3 times a day, or placebo. Treatment was double-dummy to ensure study blindness. Efficacy was primarily established by maximal walking distance (MWD), measured with constant-speed, variable-grade treadmill testing, assessed at baseline and at 4, 8, 12, 16, 20, and 24 weeks. Mean MWD of cilostazol-treated patients (n=227) was significantly improved at every visit compared with patients who received pentoxifylline (n=232) or placebo (n=239). After 24 weeks of cilostazol, mean MWD increased 53.9% (107.3 m) from baseline, and the effect had not plateaued. This was better (P < 0.001) than the 30.4% (64.4 m) MWD improvement with pentoxifylline. MWD improvement with pentoxifylline was similar (P = 0.82) to that of placebo (64.7 m). Deaths and serious adverse event rates were similar in each group. Common side effects included headache (27.8% with cilostazol, 11.2% with pentoxifylline, 11.7% with placebo), palpitations (17.2% with cilostazol, 2.2% with pentoxifylllne, 1.3% with placebo), and abnormal stools. Cilostazol was significantly better than pentoxifylline or placebo for increasing walking distances; pentoxifylline was no better than placebo.

Dawson, David L.↗

Polyimide-Silica Hybrids Containing Novel Phenylethynyl Imide Silanes as Coupling Agents for Surface-Treated Titanium Alloy

Polyimide-silica hybrids composed of an organic precursor containing a novel phenylethynyl imide silane and an inorganic precursor were evaluated as an adhesion-promoting interphase between surface-treated titanium alloy and a phenylethynyl-containing imide adhesive. The phenylethynyl groups present in the organic precursor, either as a pendent or end group, can bond chemically with a phenylethynyl-containing imide adhesive during processing, while the silane groups of the organic precursor would react chemically with the inorganic precursor. In addition, the inorganic precursor is able to react with the titanium alloy to form a stable bond with the metal oxide. Bond strength and durability were evaluated by single lap shear tests at various conditions. Lap shear specimens exhibited predominantly cohesive failure after a 3-d water boil with 92% retention of the initial room temperature strength. Morphology and chemical composition of the hybrid interphase were investigated with scanning electron microscopy, X-ray photoelectron spectroscopy, and Auger electron spectroscopy, which revealed development of a silicon-gradient, hybrid structure between the metal substrate and the adhesive.

Park, C.↗

Properties of M40J Carbon/PMR-II-50 Composites Fabricated with Desized and Surface Treated Fibers. Characterization of M40J Desized and Finished Fibers

To increase performance and durability of high temperature composites for potential rocket engine components, it is necessary to optimize wetting and interfacial bonding between high modulus carbon fibers and high temperature polyimide resins. It has been previously demonstrated that the electro-oxidative shear treatments used by fiber manufacturers are not effective on higher modulus fibers that have fewer edge and defect sites in the surface crystallites. In addition, sizings commercially supplied on most carbon fibers are not compatible with polyimides. This study was an extension of prior work characterizing the surface chemistry and energy of high modulus carbon fibers (M40J and M60J, Torray) with typical fluorinated polyimide resins, such as PMR-II-50. A continuous desizing system which utilizes environmentally friendly chemical- mechanical processes was developed for tow level fiber and the processes were optimized based on weight loss behavior, surface elemental composition (XPS) and morphology (FE-SEM) analyses, and residual tow strength of the fiber, and the similar approaches have been applied on carbon fabrics. Both desized and further treated with a reactive finish were investigated for the composite reinforcement. The effects of desizing and/or subsequent surface retreatment on carbon fiber on composite properties and performance including fiber-matrix interfacial mechanical properties, thermal properties and blistering onset behavior will be discussed in this presentation.

Allred, Ronald E.↗

Epstein-Barr virus and human immunodeficiency virus serological responses and viral burdens in HIV-infected patients treated with HAART

Epstein-Barr virus (EBV) associated non-Hodgkin lymphoma is recognized as a complication of human immunodeficiency virus (HIV) infection. Little is known regarding the influence of highly active antiretroviral therapy (HAART) on the biology of EBV in this population. To characterize the EBV- and HIV-specific serological responses together with EBV DNA levels in a cohort of HIV-infected adults treated with HAART, a study was conducted to compare EBV and HIV serologies and EBV DNA copy number (DNAemia) over a 12-month period after the commencement of HAART. All patients were seropositive for EBV at baseline. Approximately 50% of patients had detectable EBV DNA at baseline, and 27/30 had detectable EBV DNA at some point over the follow-up period of 1 year. Changes in EBV DNA copy number over time for any individual were unpredictable. Significant increases in the levels of Epstein-Barr nuclear antigen (EBNA) and Epstein-Barr early antigen (EA) antibodies were demonstrated in the 17 patients who had a good response to HAART. Of 29 patients with paired samples tested, four-fold or greater increases in titers were detected for EA in 12/29 (41%), for EBNA in 7/29 (24%), for VCA-IgG in 4/29 (14%); four-fold decreases in titers were detected in 2/29 (7%) for EA and 12/29 (41%) for EBNA. A significant decline in the titer of anti-HIV antibodies was also demonstrated. It was concluded that patients with advanced HIV infection who respond to HAART have an increase in their EBV specific antibodies and a decrease in their HIV-specific antibodies. For the cohort overall, there was a transient increase in EBV DNA levels that had declined by 12 months. Copyright 2002 Wiley-Liss, Inc.

NASA Discipline Regulatory Physiology↗

On the Development of an Efficient Parallel Hybrid Solver with Application to Acoustically Treated Aero-Engine Nacelles

A finite element solution to the convected Helmholtz equation in a nonuniform flow is used to model the noise field within 3-D acoustically treated aero-engine nacelles. Options to select linear or cubic Hermite polynomial basis functions and isoparametric elements are included. However, the key feature of the method is a domain decomposition procedure that is based upon the inter-mixing of an iterative and a direct solve strategy for solving the discrete finite element equations. This procedure is optimized to take full advantage of sparsity and exploit the increased memory and parallel processing capability of modern computer architectures. Example computations are presented for the Langley Flow Impedance Test facility and a rectangular mapping of a full scale, generic aero-engine nacelle. The accuracy and parallel performance of this new solver are tested on both model problems using a supercomputer that contains hundreds of central processing units. Results show that the method gives extremely accurate attenuation predictions, achieves super-linear speedup over hundreds of CPUs, and solves upward of 25 million complex equations in a quarter of an hour.

Watson, Willie R.↗

Methods for treating congestive heart failure

The invention features methods of treating or preventing congestive heart failure by administering a polypeptide containing an epidermal growth factor-like domain encoded by a neuregulin gene.

Marchionni, Mark↗

Heat Treated Carbon Fiber Material Selection Database

Carbon fibers are used in a variety high temperature applications and materials. However, one limiting factor in their transition into additional applications is an understanding of their functional properties during component processing and function. The requirements on the fibers are governed by the nature of the materials and the environments in which they will be used. The current carbon fiber vendor literature is geared toward the polymeric composite industry and not the ceramic composite industry. Thus, selection of carbon fibers is difficult, since their properties change as a function of heat treatment, processing or component operational temperature, which ever is greatest. To enable proper decisions to be made, a program was established wherein multiple fibers were selected and heat treated at different temperatures. The fibers were then examined for their physical and mechanical properties which are reported herein.

Effinger, M.↗

Medical Devices Assess, Treat Balance Disorders

You may have heard the phrase as difficult as walking and chewing gum as a joking way of referring to something that is not difficult at all. Just walking, however, is not all that simple physiologically speaking. Even standing upright is an undertaking requiring the complex cooperation of multiple motor and sensory systems including vision, the inner ear, somatosensation (sensation from the skin), and proprioception (the sense of the body s parts in relation to each other). The compromised performance of any of these elements can lead to a balance disorder, which in some form affects nearly half of Americans at least once in their lifetimes, from the elderly, to those with neurological or vestibular (inner ear) dysfunction, to athletes with musculoskeletal injuries, to astronauts returning from space. Readjusting to Earth s gravity has a significant impact on an astronaut s ability to balance, a result of the brain switching to a different "model" for interpreting sensory input in normal gravity versus weightlessness. While acclimating, astronauts can experience headaches, motion sickness, and problems with perception. To help ease the transition and study the effects of weightlessness on the body, NASA has conducted many investigations into post-flight balance control, realizing this research can help treat patients with balance disorders on Earth as well. In the 1960s, the NASA-sponsored Man Vehicle Laboratory at the Massachusetts Institute of Technology (MIT) studied the effects of prolonged space flight on astronauts. The lab s work intrigued MIT doctoral candidate Lewis Nashner, who began conducting NASA-funded research on human movement and balance under the supervision of Dr. Larry Young in the MIT Department of Aeronautics and Astronautics. In 1982, Nashner s work resulted in a noninvasive clinical technique for assessing the cooperative systems that allow the body to balance, commonly referred to as computerized dynamic posturography (CDP). CDP employs a series of dynamic protocols to isolate and assess balance function deficiencies. The technology was based on Nashner s novel, engineering-inspired concept of balance as an adaptable collaboration between multiple sensory and motor systems. CDP proved useful not only for examining astronauts, but for anyone suffering from balance problems. Today, CDP is the standard medical tool for objectively evaluating balance control.

Source record↗

Methods for Treating Congestive Heart Failure

The invention features methods of treating or preventing congestive heart failure by administering a polypeptide containing an epidermal growth factor-like domain encoded by a neuregulin gene.

Marchionni, Mark↗