Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Novel approaches in hadron spectroscopy

The last two decades have witnessed the discovery of a myriad of new and unexpected hadrons. The future holds more surprises for us, thanks to new-generation experiments. Understanding the signals and determining the properties of the states requires a parallel theoretical effort. To make full use of available and forthcoming data, a careful amplitude modeling is required, together with a sound treatment of the statistical uncertainties, and a systematic survey of the model dependencies. We review the contributions made by the Joint Physics Analysis Center to the field of hadron spectroscopy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectroscopy-based isotopic (δ 13 C) analysis for high spatial resolution of carbon exchange in the rhizosphere

The rhizosphere is a highly dynamic zone bridging plant roots with needed nutrient resources in soil. While the rhizosphere may be small, it has a disproportionally large impact on plant success and biomass production. A suite of rhizosphere-hosted microbial and geochemical interactions facilitate nutrient acquisition by plant roots, and, in turn, the roots stimulate these processes by supplying organic carbon into the rhizosphere. The small physical dimensions of the rhizosphere, however, can constrain efforts to elucidate key carbon exchange processes and their spatial extent and localization. We present a method for spatially resolved δ 13 C analysis of rhizosphere samples by coupling laser ablation (LA) sampling with isotopic analysis using capillary absorption spectroscopy (CAS) which differs from conventional mass spectrometer (MS) approaches. The CAS system has high sensitivity (requires fewer nanomoles of CO 2 per analysis) than comparable MS systems, which enables reduced sample size requirements to thereby improve spatial resolution (from 25 μm to as low as a projected 5 μm spatial resolution). We demonstrate the utility of CAS using rhizosphere samples from switchgrass plants exposed to 13 CO 2 . As a result, this technique will provide a capability for tracking the extent and spatial distribution of root exudate into the rhizosphere at highly detailed spatial scales.

59 BASIC BIOLOGICAL SCIENCES↗

Stationary and drone-assisted methane plume localization with dispersion spectroscopy

This work presents stationary and mobile retroreflector-based remote sensing techniques for methane leak localization and quantification using chirped laser dispersion spectroscopy equipped with a custom laser transceiver capable of continuous tracking of a flying drone and coupled with inverse atmospheric gas dispersion modeling. The techniques demonstrate the ability to localize leaks as low as 0.13 g CH 4 ·s -1 , which are up to 25 times smaller than those typically observed at natural gas facilities, as well as actively track a moving retroreflector mounted on a lightweight (~250 g) drone to enable spatial plume reconstruction. This system exhibited a 2.3 ppm-m sensitivity over pathlengths of 40–150 m. Source localization to within ±7 m is demonstrated using a modified horizontal radial plume mapping technique with a stationary retroreflector grid. Meanwhile, the mobile system utilizing a drone-mounted retroreflector is able to localize a controlled release within ±1 m of its source location and estimate leak rates using inversion techniques assuming type B Gaussian plume stability class within ±30% error with respect to the actual low flow rate releases.

47 OTHER INSTRUMENTATION↗

Development of chemometric models to classify solid-state U materials by micro-Raman spectroscopy

Discerning uranium (U) particles found in environmental sampling is of interest for monitoring the peaceful use of nuclear material. In this study, a soft independent modeling of class analogy (SIMCA) library was successfully developed for the classification of a four-class system consisting of α-U 3 O 8 , UO 2 , UO 2 (NO 3 ) 2 ·6H 2 O (UNH), and UO 2 O 2 ·4H 2 O (studtite) by Raman spectroscopy in the presence of matrix particulates and additional outliers. Spectral variability between numerous particles of each type revealed appreciable differences as a function of particle size with respect to hydration state and potential oxide phase within each class. Interclass variability was accounted for using both unsupervised and supervised chemometric models. The supervised SIMCA model displayed reasonable sensitivity for each U class and a high degree of specificity by returning whether a spectrum belonged to one class or not. This work demonstrates how Raman spectral features and chemometrics can be used to distinguish U materials from one another and from matrix materials such as flint clay. Combining the outlined chemometric approach with Raman mapping sequences could provide a rapid, nondestructive technique to characterize the chemical composition of a diverse collection of U compounds amid background samples for environmental sampling, nuclear forensics, and industrial applications.

Actinide↗

Pu(IV) quantification via visible–near-infrared absorption spectroscopy: tackling interferences using D-optimal design and partial least squares

Here, this study presents a novel analytical approach for quantifying Pu(IV) in glove box environments using fiber-optic-based visible–near-infrared absorption spectroscopy in combination with partial least squares regression (PLSR) and design of experiments. The method addresses significant challenges posed by overlapping spectral features arising from Nd(III), which is a common fission product impurity, and the speciation variability of Pu(IV) nitrato complexes in HNO 3 concentrations ranging from 2.5 to 11 M. A curated training set consisting of data from 20 samples was developed via D-optimal design to enable robust PLSR model calibration for Pu(IV) using the near-infrared band near 1050 nm. The training set was acquired from samples in cuvettes with a 1-cm path length and was used to build the PLSR model. The robustness of the model was validated with data collected using a dip probe with a 1-cm path length and varying Pu(IV) concentrations. The strong performance of the model indicates good model transfer from cuvette to dip probe and highlights the potential for in situ measurements and online monitoring of reactions in a crystallization reactor vessel. The results demonstrate that this combined spectroscopic and chemometric approach can accurately and simultaneously quantify Pu(IV) and HNO 3 , thereby offering a promising tool for real-time monitoring in process environments.

Actinide↗

The use of a digital micromirror array as a temporal gate and spatial-filtering device for laser-induced breakdown spectroscopy and laser ablation molecular isotopic spectrometry

A digital micromirror array (DMMA) is used in a simple and inexpensive approach for spatially resolved temporal gating of atomic emission detection in laser-induced breakdown spectroscopy (LIBS). Selected mirrors in the array are actuated at a time delayed from the primary laser pulse, permitting optical gating with a response time of 160 ns while using a conventional CCD detector. Detector gating is shown to decrease noise from short-lived spectroscopic background (both continuum and N II from air), improving signal-to-background ratios by 22-times for selected samples and emission lines. The utility of rapid temporal gating is also demonstrated for the optical detection of isotopes using the laser-ablation molecular isotope spectrometry (LAMIS) experiment. Additionally, optical temporal gating and spatial filtering are used to isolate regions of the laser-induced plasma, enhancing signal from molecular emission. The potential of the simple technique for use in field-portable LIBS and LAMIS experiments is explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post-landing major element quantification using SuperCam laser induced breakdown spectroscopy

The SuperCam instrument on the Perseverance Mars 2020 rover uses a pulsed 1064 nm laser to ablate targets at a distance and conduct laser induced breakdown spectroscopy (LIBS) by analyzing the light from the resulting plasma. SuperCam LIBS spectra are preprocessed to remove ambient light, noise, and the continuum signal present in LIBS observations. Prior to quantification, spectra are masked to remove noisier spectrometer regions and spectra are normalized to minimize signal fluctuations and effects of target distance. In some cases, the spectra are also standardized or binned prior to quantification. To determine quantitative elemental compositions of diverse geologic materials at Jezero crater, Mars, we use a suite of 1198 laboratory spectra of 334 well-characterized reference samples. The samples were selected to span a wide range of compositions and include typical silicate rocks, pure minerals (e.g., silicates, sulfates, carbonates, oxides), more unusual compositions (e.g., Mn ore and sodalite), and replicates of the sintered SuperCam calibration targets (SCCTs) onboard the rover. For each major element (SiO 2 , TiO 2 , Al 2 O 3 , FeO T , MgO, CaO, Na 2 O, K 2 O), the database was subdivided into five “folds” with similar distributions of the element of interest. One fold was held out as an independent test set, and the remaining four folds were used to optimize multivariate regression models relating the spectrum to the composition. We considered a variety of models, and selected several for further investigation for each element, based primarily on the root mean squared error of prediction (RMSEP) on the test set, when analyzed at 3 m. In cases with several models of comparable performance at 3 m, we incorporated the SCCT performance at different distances to choose the preferred model. Shortly after landing on Mars and collecting initial spectra of geologic targets, we selected one model per element. Subsequently, with additional data from geologic targets, some models were revised to ensure results that are more consistent with geochemical constraints. The calibration discussed here is a snapshot of an ongoing effort to deliver the most accurate chemical compositions with SuperCam LIBS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elemental fractionation in aerosol laser-induced breakdown spectroscopy with nanosecond and femtosecond laser ablation

For the purpose of realizing atmospheric radiation plume tracking, laser-induced breakdown spectroscopy (LIBS) was performed to characterize Cs atomic emissions from airborne nanoparticles in a binary particle matrix using nanosecond and femtosecond laser ablation. As a surrogate to multi-element nuclear fallout particulates, both Cs and Na solutions were mixed with Cu at a 1:1.45 M concentration ratio and aerosolized to study elemental fractionation in atomic emissions, revealing Na I resonance emissions are enhanced whereas Cs I resonance emissions are reduced with Cu present despite sharing similar electronic and chemical properties. Femtosecond laser ablation reduced elemental fractionation effects by more than 50% while retaining the same temporal fractionation trends for Cs and Na. The origin of elemental fractionation in aerosol LIBS was further investigated using Al and Ti aerosols which revealed that the particle matrix induces changes to the local plasma temperature, population of atomic states, and subsequent molecular association and emission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing analytical merits of laser-induced breakdown spectroscopy of hydrogen isotopes using an orthogonal double-pulsing scheme

Accurate detection and quantification of hydrogen isotopes in solid materials are vital for diverse applications, including fusion energy, hydrogen storage, and tritium production. Laser-induced breakdown spectroscopy (LIBS) is a well established, rapid, standoff method for this purpose, but it faces challenges related to the analytical merits required for isotopic analyses. In this study, we enhance the analytical and detection capabilities of traditional single-pulse LIBS by implementing an orthogonal double pulsing approach, focusing on the analysis of a range of 2 H concentrations in Zircaloy-4 substrates (acting as a proxy for 3 H). The double-pulse experiments employed an orthogonal re-heating configuration with two nanosecond Nd:YAG lasers. We systematically evaluated critical parameters affecting the signal intensity in double-pulse LIBS, including interpulse delay, ambient gas pressure, and heating laser energy. Finally, our results demonstrate that employing an orthogonal double-pulse scheme significantly enhances 2 H α emission while minimizing line broadening and self-absorption, ultimately improving the technique’s analytical capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Real-time monitoring of trace noble gases using laser-induced breakdown spectroscopy—An investigation of the impact of bulk gas on plasma properties and sensitivity

The impact of Ar and He bulk gases on laser-induced breakdown spectroscopy (LIBS) real-time monitoring of trace Xe and Kr was assessed. LIBS is being developed as a monitoring tool for measuring noble gas transport in molten salt systems, in which traditional sensors may face challenges associated with radiation, corrosive materials, and/or mixed phases. The plasma temperature and electron densities of LIBS plasmas were measured in both static and various flowing Ar and He streams (0–5 L min −1 ). The use of an Ar bulk gas resulted in higher plasma temperature, greater electron densities by an order of magnitude, and extended plasma lifetime compared with when He bulk gas was used. Gas flow rate was found to have little impact on plasma temperature; however, its effect on electron density was significant, indicating the need to consider flow rate–specific models. Matrix effects on emission peaks were reported for both bulk gases. Due to these matrix effects, multivariate models were developed for Xe and Kr ranging from 0 to 700 ppm in both bulk gases. Although the predictive behavior was similar (root mean square error of prediction ranging from 11.1 to 20.6 ppm), the limits of detection were superior in He (Xe: 22.9 ppm, Kr: 30.4 ppm). Furthermore, these models were employed in demonstrative real-time tests (>1 h), which showed strong predictive precision (relative standard deviation <5 %) regardless of the bulk gas. Ultimately, this study provides a guide for the considerations required when developing gaseous LIBS models for real-time monitoring.

Gas flow effects↗

Spectral line-shape in collinear laser spectroscopy after atomic charge exchange

Collinear laser spectroscopy experiments on fast, neutral beams have been extensively used for studies on short-lived radioactive nuclei, taking advantage of its high sensitivity. The resulting resonance line-shape is known to show significant distortion, due to the energy exchange during the charge-exchange neutralization process, which can cause large systematic uncertainty in the determined centroid. A model for the line shape was constructed and simulated to be compared to measured Al, Si, and Ni hyperfine spectra. It is shown that the distortion is caused mainly by the transfer of electron into many different energy levels in the projectile atom and subsequent decays, rather than secondary inelastic collisions, which were often assumed in the line shape analysis before. Furthermore, the model can also be applied to other projectile–alkali pairs, providing a reliable line-shape with less fitting parameters than conventional phenomenological models.

Atom↗

Effects of oxygen on the adsorption/oxidation of aqueous Sb(III) by Fe-loaded biochar: An X-ray absorption spectroscopy study

Fe-loaded biochar (FeBC) has been considered for Sb(III) adsorption, but the effects of oxygen (O 2 ) on the adsorption need further investigation. Liquid-/solid-phase analyses were conducted to investigate the role of O 2 in the Sb(III) adsorption by FeBC. The adsorption was best described by the pseudo-second-order (PSO) model for kinetic results and by the Langmuir model for thermodynamic results. More than 96.8 % of Sb(III) was adsorbed by FeBC, and available O 2 increased the liquid-phase Sb(III) oxidation efficiency by 2.1–7.5 times. The peak changes at ~1640 and 3450 cm -1 in FTIR spectra indicated the occurrence of inner-sphere complexation between Sb(III)/Sb(V) and hydroxyl (–OH)/carboxyl (–COOH) groups in FeBC under aerobic and anaerobic conditions. Fe/Sb X-ray absorption spectroscopy (XAS) analysis results showed aqueous Sb(III) complexed to the edge-sharing Fe(III)-O-Fe(III) in FeBC. Regardless of whether O 2 was available or not, solid-phase edge-sharing Fe(III)-O-Sb(V) complexes (~3.05 Å), which had lower toxicity and migration ability than aqueous Sb(III), formed through a ligand-to-metal charge-transfer (LMCT) process. More than 91 % of adsorbed Sb(III) was oxidized to edge-sharing Fe(III)-O-Sb(V) complexes in 3 h. Additionally, the Sb(V) from liquid-phase oxidation could also directly complex to the Fe(III)-O-Fe(III) and form edge-sharing Fe(III)-O-Sb(V) complexes. Here these results provide evidence to inform further FeBC application for the Sb-contaminated water treatment.

54 ENVIRONMENTAL SCIENCES↗

Determine Oxidation State of Transition Metals in Molten Salt Corrosion using Electron Energy Loss Spectroscopy

This work utilizes electron energy loss spectroscopy (EELS) to identify oxidation state of alloying elements in Ni-based alloys after exposure to molten chloride salt systems. Pure Ni and Ni 20Cr model alloy were corroded in molten ZnCl2 and KCl-MgCl2 under argon atmosphere at various temperatures. Oxidation states of Cr (Cr3+) and Ni (Ni2+) in the molten salt after corrosion were determined by monitoring changes in the L2,3 edges of corresponding EELS spectra. Oxidation state mapping technique using principal component analysis and multiple linear least squares fitting in HyperSpy Python package was developed.

36 MATERIALS SCIENCE↗

CDB-AP: An application for coincidence Doppler broadening spectroscopy analysis

Coincidence Doppler Broadening (CDB) Positron Annihilation Spectroscopy (PAS) is a material analysis technique that can be used to non-destructively measure characteristics of structural defects in samples. Analyzing and comparing large datasets obtained using this technique, however, can be complicated and time intensive. The Coincidence Doppler Broadening Analysis Program (CDB-AP) is a graphical user interface that facilitates rapid analysis of many data files while using transparent processes. It is already used in three laboratories at Idaho National Laboratory and can be used in laboratories worldwide.

36 MATERIALS SCIENCE↗

Interfacial bond characterization of epoxy adhesives to aluminum alloy and carbon fiber-reinforced polyamide by vibrational spectroscopy

Vibrational spectroscopic technique has been utilized to investigate interfacial bonding chemistry of two epoxy adhesive products, XP0012 and XP5005F, on plasma-treated AA6061 and carbon fiber-reinforced polyamide 66 (CFRP-PA66) surfaces. The change in vibrational peak ratios was measured by attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy to deduce bonding mechanisms. Both adhesives showed strong crosslinking polymerization of hydroxyl- and amine-initiated epoxy ring opening on AA6061 surface, but on CFRP surface XP0012 formed a simple amide linkage by the reaction of surface hydroxyl groups and nitrile groups of curing agent, and XP5005F formed a crosslinked network by hydroxyl-initiated epoxy ring opening polymerization. The different interfacial bonding formation of two adhesives on CFRP-PA66 surface is attributed to additive effect. Addition of additives to epoxy adhesives (XP5005F) changed the interfacial bonding mechanism on CFRP-PA66 surface, rather forming hydroxyl-initiated epoxy opening crosslinking polymerization than a simple amide bond formation (XP0012). The interfacial bonding chemistry was also proved by addition of bisphenol A (BA) to a simplified model diglycidyl ether of bisphenol A/dicyandiamide (DGEBA/DICY) epoxy system. When BA was added to the model DGEBA/DICY system, epoxy ring gradually decreased on CFRP-PA66 surface, while without BA, DGEBA/DICY showed only decrease in a nitrile peak intensity in ATR-FTIR. In conclusion, the foregoing different types of interfacial chemical bonds at the adhesive/CFRP-PA66 interfaces can affect the lap shear behavior of the joint.

36 MATERIALS SCIENCE↗

Methanol adsorption and dissociation on GaP(110) studied by ambient pressure X-ray photoelectron spectroscopy

Ambient pressure X-ray photoelectron spectroscopy (AP-XPS) was used to investigate methanol (CH 3 OH) adsorption and reaction on the GaP(110) surface. Exposure of CH 3 OH to GaP(110) at room temperature led to the formation of at least four different surface species as indicated by analysis of C 1s and O 1s XPS features. By combining AP-XPS data with density functional theory calculations, the surface species were identified as methoxy (CH 3 O*), formaldehyde (CH 2 O*), and paired methanol (p-CH 3 O*H) and methoxy (p-CH 3 O*) species, where “paired” means that they belong to a hydrogen-bonded methoxy-methanol complex. Asterisk * here indicates an adsite. The formation of CH 2 O* via the dehydrogenation of CH 3 O* was shown to be limited by the availability of vacant phosphorus (P) sites on GaP(110). With an increase in CH 3 OH pressure, the fractional coverage of CH 3 O* species reached 0.55, and the surface P sites were completely saturated with hydrogen. Under a constant CH 3 OH pressure of 0.5 Torr, the surface concentration of the paired species and of CH 2 O* remained constant until 400 K. At higher temperatures, thermally driven reactions led to a significant increase in the concentration of surface CH x * species, which suggests that C-O bond cleavage of the CH 3 O group is the dominant decomposition mechanism on GaP(110). In conclusion, based on the reactivity of GaP(110) toward CH 3 OH dehydrogenation, elevated temperatures and CH 3 OH pressures may be used to functionalize this surface.

36 MATERIALS SCIENCE↗

Chemometrics and visible diffuse reflectance spectroscopy to classify plutonium dioxide

Diffuse reflectance (DR) spectra in the Vis-NIR (∼380–1050 nm) region were acquired for a series of PuO 2 samples with a spot size of about 10 × 10 μm. Two batches of six PuO 2 samples, synthesized approximately 7.5 months apart, were prepared using both Pu(III) and Pu(IV) oxalate precursors at three distinct calcination temperatures (450, 650, and 950 °C). This yielded a total of 12 PuO 2 samples and 433 DR spectra. The DR spectrum of PuO 2 contained numerous peaks in the visible region, and characteristic features were identified with respect to calcination temperature and chemistry. A distinct peak multiplet near 615 nm was observed for samples prepared at low calcination temperatures, and a peak near 660 nm was observed for higher calcination temperatures. A multivariate classification strategy based on principal component analysis (PCA) was developed to distinguish PuO 2 calcination temperatures of 450, 650, and 950 °C with 100 % accuracy. Classification results also indicate the potential to distinguish chemical processing history (i.e., Pu(III) or Pu(IV)) based on the spectra with 72 % accuracy based on k-nearest neighbors applied to the PCA scores. Partial least squares discriminant analysis was used to identify variation among batches with 88 % accuracy and found that peaks near 669, 681, 811, and 970 nm were the most useful for predicting the batch identity. Here, this work demonstrates how micro-diffuse reflectance spectroscopy and chemometrics can be used to classify PuO 2 processing history based on Vis-NIR spectral features. Combining the chemometric approach with mapping sequences could provide a rapid, nondestructive approach to classify Pu oxide materials for environmental, forensics, and nonproliferation applications.

Actinide↗