Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPACE SIMULATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Effect of thruster pulse length on thruster-exhaust damage of S13G white thermal control coatings

Rocket exhaust products which strike thermal control surfaces cause changes in solar absorptance (Alpha Sub s) and thermal emittance (Epsilon) of these surfaces. A study was made of the effect of rocket pulse duration on exhaust damage to S13G white coatings. Two pulse lengths were used - 14 msec and 50 msec. An MMH/N204 bipropellant 5-lb thrust rocket was fired into a simulated space environment with a vacuum of 0.00001 torr, a liquid helium temperature enclosure, and solar radiation. The changes in solar absorptance and thermal emittance of S13G white coatings due to rocket exhaust were made in-situ for total firing times of 58 seconds with 14 msec pulses and 223.7 sec with 50 msec pulses. The solar absorptance of S13G increased 25 percent due to 223.7 sec of exposure to 50 msec pulses and the thermal emittance was unaffected. The ratio of Alpha Sub s/Epsilon therefore increased by 25 percent. The short 14 msec pulse exhaust exposure caused between 40 and 70 percent increase in solar absorptance and a decrease of between 13 and 18 percent in thermal emittance. The corresponding increase in Alpha Sub s/Epsilon ratio was between 80 and 100 percent. Ultraviolet radiation was present in the short pulse test and may have contributed to the large damage of that test.

Sommers, R. D.↗

The Automated Primate Research Laboratory (APRL)

A description is given of a self-contained automated primate research laboratory to study the effects of weightlessness on subhuman primates. Physiological parameters such as hemodynamics, respiration, blood constituents, waste, and diet and nutrition are analyzed for abnormalities in the simulated space environment. The Southeast Asian pig-tailed monkey (Macaca nemistrina) was selected for the experiments owing to its relative intelligence and learning capacity. The objective of the program is to demonstrate the feasibility of a man-tended primate space flight experiment.

Pace, N.↗

Degradation of learned skills: Effectiveness of practice methods on visual approach and landing skill retention

Flight control and procedural task skill degradation, and the effectiveness of retraining methods were evaluated for a simulated space vehicle approach and landing under instrument and visual flight conditions. Fifteen experienced pilots were trained and then tested after 4 months either without the benefits of practice or with static rehearsal, dynamic rehearsal or with dynamic warmup practice. Performance on both the flight control and procedure tasks degraded significantly after 4 months. The rehearsal methods effectively countered procedure task skill degradation, while dynamic rehearsal or a combination of static rehearsal and dynamic warmup practice was required for the flight control tasks. The quality of the retraining methods appeared to be primarily dependent on the efficiency of visual cue reinforcement.

Sitterley, T. E.↗

A modified quadrupole mass spectrometer with custom RF link rods driver for remote operation

A commercial quadrupole residual gas analyzer system has been upgraded for operation at extended cable lengths. Operation inside a vacuum chamber for the standard quadrupole nude head is limited to approximately 2 m from its externally located rf/dc generator because of the detuning of the rf oscillator circuits by the coaxial cable reactance. The advance of long distance remote operation inside a vacuum chamber for distances of 45 and 60 m was made possible without altering the quadrupole's rf/dc generator circuit by employing an rf link to drive the quadrupole rods. Applications of the system have been accomplished for in situ space simulation thermal/vacuum testing of sophisticated payloads.

Tashbar, P. W.↗

Development of techniques for advanced optical contamination measurement with internal reflection spectroscopy, phase 1, volume 1

The feasibility of monitoring volatile contaminants in a large space simulation chamber using techniques of internal reflection spectroscopy was demonstrated analytically and experimentally. The infrared spectral region was selected as the operational spectral range in order to provide unique identification of the contaminants along with sufficient sensitivity to detect trace contaminant concentrations. It was determined theoretically that a monolayer of the contaminants could be detected and identified using optimized experimental procedures. This ability was verified experimentally. Procedures were developed to correct the attenuated total reflectance spectra for thick sample distortion. However, by using two different element designs the need for such correction can be avoided.

Hayes, J. D.↗

Degradation of learned skills. Static practice effectiveness for visual approach and landing skill retention

The effectivess of an improved static retraining method was evaluated for a simulated space vehicle approach and landing under instrument and visual flight conditions. Experienced pilots were trained and then tested after 4 months without flying to compare their performance using the improved method with three methods previously evaluated. Use of the improved static retraining method resulted in no practical or significant skill degradation and was found to be even more effective than methods using a dynamic presentation of visual cues. The results suggested that properly structured open loop methods of flight control task retraining are feasible.

Sitterley, T. E.↗

Remote control circuit breaker evaluation testing

Engineering evaluation tests were performed on several models/types of remote control circuit breakers marketed in an attempt to gain some insight into their potential suitability for use on the space shuttle vehicle. Tests included the measurement of several electrical and operational performance parameters under laboratory ambient, space simulation, acceleration and vibration environmental conditions.

Bemko, L. M.↗

Evaluation report for toggle switches: Micro Switch and Cutler-Hammer models per MIL-S-3950

Several models of hermetically sealed toggle switches meeting the requirements of MIL-S-3950, were evaluated to determine the probability that they would withstand the environmental requirements of, and therefore be suitable for use on, the space shuttle vehicle. The evaluation was started with a comparison of the environmental requirements for space shuttle hardware. This was followed with in-house testing for those environments where a reasonably firm conclusion could not be drawn in the comparison. Space simulation, acceleration, and vibration testing were performed in-house.

Labberton, D.↗

A remote operation quadrupole mass spectrometer using a custom radio-frequency link approach

A commercial quadrupole mass spectrometer (residual gas analyzer, RGA) system has been modified to operate at large separations of its electronics console and sensing head. The methods implemented have made practical applications, as well as operation, of such a system possible for the first time. This advance was stimulated by a need for placing sensors at remote (45 or 60 m) chamber locations for space simulation testing of orbital flight spacecraft. Emphasis is placed on instrument functional requirements and describing the hardware changes and adjustment techniques necessary to assure operation at the extended cable lengths.

Tashbar, P. W.↗

Study of acoustic emission during mechanical tests of large flight weight tank structure

A PPO-insulated, flight-weight, subscale, aluminum tank was monitored for acoustic emissions during a proof test and during 100 cycles of environmental test simulating space flights. The use of a combination of frequency filtering and appropriate spatial filtering to reduce background noise was found to be sufficient to detect acoustic emission signals of relatively small intensity expected from subcritical crack growth in the structure. Several emission source locations were identified, including the one where a flaw was detected by post-test x-ray inspections. For most source locations, however, post-test inspections did not detect flaws; this was partially attributed to the higher sensitivity of the acoustic emission technique than any other currently available NDT method for detecting flaws. For these non-verifiable emission sources, a problem still remains in correctly interpreting observed emission signals.

Mccauley, B. O.↗

Better vacuum by removal of diffusion-pump-oil contaminants

The complex problem of why large space simulation chambers do not realize true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance were identified, and some advances in vacuum distillation-fractionation technology were achieved which resulted in a two-decade-or-more lower ultimate pressure. Data are presented to show the overall or individual contaminating effects of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and for reclaiming contaminated oil by high-vacuum molecular distillation are described. Conceptual self-cleansing designs and operating procedures are proposed for modifying large diffusion pumps into high-efficiency distillation devices. The potential exists for application of these technological advancements to other disciplines, such as medicine, biomedical materials, metallurgy, refining, and chemical (diffusion-enrichment) processing.

Buggele, A. E.↗

Particulate contamination spectrometer. Volume 1: Technical report

A laser particulate spectrometer (LPS) system was developed to measure the size and speed distributions of particulate (dusts, aerosols, ice particles, etc.) contaminants. Detection of the particulates was achieved by means of light scattering and extinction effects using a single laser beam to cover a size range of 0.8 to 275 microns diameter and a speed range of 0.2 to 20 meter/second. The LPS system was designed to operate in the high vacuum environment of a space simulation chamber with cold shroud temperatures ranging from 77 to 300 K.

Schmitt, R. J.↗

Development of an advanced spacecraft water and waste materials processing system

An Integrated Waste Management-Water System (WM-WS) which uses radioisotopes for thermal energy is described and results of its trial in a 4-man, 180 day simulated space mission are presented. It collects urine, feces, trash, and wash water in zero gravity, processes the wastes to a common evaporator, distills and catalytically purifies the water, and separates and incinerates the solid residues using little oxygen and no chemical additives or expendable filters. Technical details on all subsystems are given along with performance specifications. Data on recovered water and heat loss obtained in test trials are presented. The closed loop incinerator and other projects underway to increase system efficiency and capacity are discussed.

Murray, R. W.↗

Combined environmental effects on polymers

A series of space simulation tests on FEP Teflon and other polymeric thermal control coatings was conducted using UV, electrons, protons and Lyman-alpha wavelength vacuum UV radiation. Interest was centered on simulating synchronous altitude radiation environment conditions. Physical changes in materials included loss of specularity and introduction of a high density of photographable tracking defects on a microscopic scale. An example shows the discharge of trapped electrons when dielectric strength is exceeded. This leaves a portion of the Teflon volume no longer clear, but diffusely transmitting and reflecting. Thermophysical changes included degradation of solar absorptance coefficients as much as five-fold. The situation that prevails for earth orbit contrasted with polymer performance in the solar wind. It is suggested that conductive overcoatings be developed for polymers and other flexible materials, comparable or superior to those available for fused silica SSMs.

Fogdall, L. B.↗

Thermoelastic analysis of solar window of a vacuum chamber

It has been noted during space simulation test programs that the chamber penetration window becomes the limiting factor as the solar intensity increases. The temperature at the center of the window normally attains a level of 550 C, while the edge temperature remains at about 35 C. The stresses produced by this thermal gradient combined with the atmospheric pressure are studied within the framework of classical theory of elasticity. The solution for the problem is obtained by solving the static uncoupled thermoelastic equations for a circular blank, subjected to nonuniform heat on one face, by introduction of two auxiliary variables. The displacements are expressed in terms of Bessel functions and parameters of interest are computed at various mesh points of the window. The maximum principal stresses thus obtained show that even with steep temperature gradient, the safety factor is acceptable.

Amba-Rao, C. L.↗

Ultraviolet corona detection sensor study

The feasibility of detecting electrical corona discharge phenomena in a space simulation chamber via emission of ultraviolet light was evaluated. A corona simulator, with a hemispherically capped point to plane electrode geometry, was used to generate corona glows over a wide range of pressure, voltage, current, electrode gap length and electrode point radius. Several ultraviolet detectors, including a copper cathode gas discharge tube and a UV enhanced silicon photodiode detector, were evaluated in the course of the spectral intensity measurements. The performance of both silicon target vidicons and silicon intensified target vidicons was evaluated analytically using the data generated by the spectroradiometer scans and the performance data supplied by the manufacturers.

Schmitt, R. J.↗

Nonelastomeric Rod Seals for Advanced Hydraulic Systems

Advanced high temperature hydraulic system rod sealing requirements can be met by using seals made of nonelastomeric (plastic) materials in applications where elastomers do not have adequate life. Exploratory seal designs were optimized for advanced applications using machinable polyimide materials. These seals demonstrated equivalent flight hour lives of 12,500 at 350 F and 9,875 at 400 F in advanced hydraulic system simulation. Successful operation was also attained under simulated space shuttle applications; 96 reentry thermal cycles and 1,438 hours of vacuum storage. Tests of less expensive molded plastic seals indicated a need for improved materials to provide equivalent performance to the machined seals.

Hady, W. F.↗

Passivation of pigment particles for thermal control coatings

The preparation of a matrix of 48 samples consisting of pigments and pigmented paints is described. The results obtained from testing these samples by electron spin resonance and by in situ spectral reflectance measurements in space simulation tests are presented. Conclusions and recommendations for further research are given.

Sancier, K. M.↗