Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPACE SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Investigation of electrical noise in selenium-immersed thermistor bolometers

The selenium immersed, thermistor bolometer, IR detector failed due to spurious and escalating electrical noise outburst as a function of time at elevated temperatures during routine ground based testing in a space simulated environment. Spectrographic analysis of failed bolometers revealed selenium pure zones in the insulating selenium arsenic (Se-As) glass film which surrounds the active sintered Mn, Ni, Co oxide flake. The selenium pure film was identified as a potentially serious failure mechanism. Significant changes were instituted in the manufacturing techniques along with more stringent process controls which eliminated the selenium pure film and successfully produced 22study bolometers.

Tarpley, J. L.↗

P78-2 (SCATHA) satellite thermal balance test, a laboratory test

Space simulation test programs can be carried out with a high probability of being troublefree with a competent staff, a well-maintained test facility and attention to interfaces; however, full-up thermal balance tests using the solar simulator, temperature control of infrared sources, the gimbal, a large number of thermocouples, and other requirements for a high fidelity thermal balance are still a challenge. The P78-2 (Scatha) satellite was successfully tested with one interruption and a four-day abbreviated retest to verify a modification. This was accomplished in spite of the new test crew, a facility beset with several operational problems, and marginal interface control. These problems were addressed with very good results. Subsequent tests have been highly successful.

Parrish, R. P., Jr.↗

Annealing radiation damaged silicon solar cells with a copper halide laser

The use of a multiply pulsed copper halide laser to significantly anneal out the damage to silicon solar cells caused by a simulated space radiation environment is investigated. Preliminary experiments demonstrate that the amount of damage can be decreased by 41% as measured by the maximum power generated.

Pivirotto, T. J.↗

A comparison of three liquid-ventilation cooling garments during treadmill exercise

A comparative study was made of the heat transfer performance and physiological effects of three different cooling garments used under sealed garments (simulating space suits) on five male subjects, during treadmill exercise. The mean exercise metabolic rate while walking at 0.9 m/s (2 mph) was 464 plus or minus 33 W. An equilibrium condition was never reached during the uncooled suited control runs and the subjects lost approximately two percent of body weight during the exercises. The mean weight loss with an Apollo-type garment was 0.35 plus or minus 0.10 kg, and 0.26 plus or minus 0.11 kg with the full-body cooling patch garment (garment 2). With the partial-coverage cooling patch (garment 3), the weight loss was 0.52 plus or minus 0.12 kg. The data showed an increase in the leg blood flow when the working muscles were not cooled by liquid flow (garment 3), and the arm blood flow remained unchanged with and without liquid cooling to the arms.

Webbon, B.↗

The Nimbus Satellite System - Remote sensing R&D platform of the 70's

In surveying the Nimbus series, attention is given to the early problems encountered in developing the Attitude Control System and in proving its operational characteristics in a simulated space environment. A table summarizing the experiments carried out with Nimbus satellites is included. Data from the Nimbus satellites are being used in oceanography, hydrology, geology, geomorphology, geography, cartography, agriculture, and meteorology.

Haas, I. S.↗

Long titanium heat pipes for high-temperature space radiators

Titanium heat pipes are being developed to provide light weight, reliable heat rejection devices as an alternate radiator design for the Space Reactor Power System (SP-100). The radiator design includes 360 heat pipes, each of which is 5.2 m long and dissipates 3 kW of power at 775 K. The radiator heat pipes use potassium as the working fluid, have two screen arteries for fluid return, a roughened surface distributive wicking system, and a D shaped cross section container configuration. A prototype titanium heat pipe, 5.5 m long, was fabricated and tested in space simulating conditions. Results from startup and isothermal operation tests are presented. These results are also compared to theoretical performance predictions that were used to design the heat pipe initially.

Girrens, S. P.↗

Software and system level tests of a test flight mercury ion thruster subsystem

A U.S. Air Force technology spacecraft flight is scheduled to carry an Ion Auxiliary Propulsion System (IAPS) as part of its experimental payload. This paper presents the results of the successful flight-software qualification and system-level tests which were performed on IAPS. The software tests were performed with an operating engineering model ion thruster and power processing unit, and failure/off-normal recovery modes, operation with and without temperature telemetry from the thruster vaporizers, and with closed-loop control or fixed setpoint operation of the thruster vaporizers. The system-level tests cover a wide range of thermal and operating conditions with the entire system exposed to a simulated space environment.

Robson, R. R.↗

Long titanium heat pipes for high-temperature space radiators

Titanium heat pipes are being developed to provide light weight, reliable heat rejection devices as an alternate radiator design for the Space Reactor Power System (SP-100). The radiator design includes 360 heat pipes, each of which is 5.2 m long and dissipates 3 kW of power at 775 K. The radiator heat pipes use potassium as the working fluid, have two screen arteries for fluid return, a roughened surface distributive wicking system, and a D-shaped cross-section container configuration. A prototype titanium heat pipe, 5.5-m long, has been fabricated and tested in space-simulating conditions. Results from startup and isothermal operation tests are presented. These results are also compared to theoretical performance predictions that were used to design the heat pipe initially.

Girrens, S. P.↗

Simultaneous thermal vacuum testing of GPS drives for NavStar

The solar array drive assemblies for the global positioning satellite (GPS) were built and the need to perform thermal vacuum acceptance testing on at least two complete units simultaneously is emphasized. The safety of the flight hardware is of primary importance. It is found that simultaneous space simulation testing of two complete drive packages requires only minor modification to the high vacuum pump stack. Attention is given to upgrading system safeties for high vacuum operation. Major modifications are designed and implemented for the thermal control system and supporting subsystems. The automated thermal control system and test bed hardware are of primary interest.

Brown, T. G.↗

Standardization in software conversion of (ROM) estimating

Technical problems and their solutions comprise by far the majority of work involved in space simulation engineering. Fixed price contracts with schedule award fees are becoming more and more prevalent. Accurate estimation of these jobs is critical to maintain costs within limits and to predict realistic contract schedule dates. Computerized estimating may hold the answer to these new problems, though up to now computerized estimating has been complex, expensive, and geared to the business world, not to technical people. The objective of this effort was to provide a simple program on a desk top computer capable of providing a Rough Order of Magnitude (ROM) estimate in a short time. This program is not intended to provide a highly detailed breakdown of costs to a customer, but to provide a number which can be used as a rough estimate on short notice. With more debugging and fine tuning, a more detailed estimate can be made.

Roat, G. H.↗

Fatigue induced cracking in aluminum LN-2 shroud of 39 foot vacuum chamber

Fourteen years after completion of Ford's 39-foot space simulation chamber, leaks began to appear in its LN2 shroud. Although the shroud had been tight since its acceptance, cracks appeared in 1983 in some of the field welds of the one inch tubes which interconnect the LN2 panels. The resulting leaks were large enough to prevent pump down to high vacuum and could be heard easily when the chamber was at ambient conditions. New cracks appeared during each thermal cycle making it impossible to utilize the chamber for thermal vacuum testing. The analysis presented here implies that many, if not all, of the aluminum LN2 shrouds now in use may be in various stages of fatigue failure. The probability is high that fatigue cracks are working through the aluminum tubing in heat-affected zones of some field welds. The cracks may not be apparent yet, but after the shroud has experienced a certain number of thermal cycles these cracks will work through the material and become serious leaks. Fortunately, appropriate planning, analysis, and checking can, with a relatively small expenditure of money, help to avoid large and unexpected shroud failures and keep the chamber operational as long as it is needed.

Edwards, A. A.↗

Wave emissions from dc and modulated electron beams on STS 3

During the third Space Shuttle Columbia flight (STS 3) in March 1982, investigations were conducted to assess the electrical, electromagnetic, and plasma environment of the orbiter and to diagnose wave emissions and related plasma effects due to the injection of an electron beam into the surrounding ionosphere. Attention is given to wave emissions and related plasma processes which were stimulated by the first electron beam emissions from the Space Shuttle. The on-orbit measurements are compared to measurements made in a space simulation chamber. Instrumentation and operations are considered along with the plasma effects of beam emissions, wave emissions from dc beams, wave emissions from VLF-modulated beams, and wave emissions from ELF-modulated beams.

Shawhan, S. D.↗

Evaluation and prediction of long-term environmental effects of nonmetallic materials

The properties of a number of nonmetallic materials were evaluated experimentally in simulated space environments in order to develop models for accelerated test methods useful for predicting such behavioral changes. Graphite-epoxy composites were exposed to thermal cycling. Adhesive foam tapes were subjected to a vacuum environment. Metal-matrix composites were tested for baseline data. Predictive modeling designed to include strength and aging effects on composites, polymeric films, and metals under such space conditions (including the atomic oxygen environment) is discussed. The Korel 8031-00 high strength adhesive foam tape was shown to be superior to the other two tested.

Papazian, H.↗

Cardiovascular Effects of Weightlessness

Physiological changes resulting from long term weightlessness are reviewed and activities conducted to study cardiovascular deconditioning at NASA Ames are discussed. Emphasis is on using monkeys in chair rest, water immersion, and tilt table studies to simulate space environment effects.

Short, K.↗

Effects of high energy radiation on the mechanical properties of epoxy-graphite fiber reinforced composites

In an effort to elucidate the changes in molecular structural and mechanical properties of epoxy/graphite fiber composites upon exposure to ionizing radiation in a simulated space environment, spectroscopic and surface properties of tetraglycidyl-4,4'-diamino diphenyl methane (TGDDM) red with diamino diphenyl sulfone (DDS) and T-300 graphite fiber were investigated following exposure to ionizing radiation. Cobalt-60 gamma radiation and 1/2 MeV electrons were used as radiation sources. The system was studied using electron spin resonance (ESR) spectroscopy, infrared absorption spectroscopy, contact angle measurements, and electron spectroscopy for chemical analysis.

Fornes, R. E.↗

Oxidation and emittance of superalloys in heat shield applications

Recently developed superalloys that form alumina coatings have a high potential for heat shield applications for advanced aerospace vehicles at temperatures above 1095C. Both INCOLOY alloy MA 956 (of the Inco Alloys International, Inc.), an iron-base oxide-dispersion-strengthened alloy, and CABOT alloy No. 214 (of the Cabot Corporation), an alumina-forming nickel-chromium alloy, have good oxidation resistance and good elevated temperature strength. The oxidation resistance of both alloys has been attributed to the formation of a thin alumina layer (alpha-Al2O3) at the surface. Emittance and oxidation data were obtained for simulated Space Shuttle reentry conditions using a hypersonic arc-heated wind tunnel. The surface oxides and substrate alloys were characterized using X-ray diffraction and scanning and transmission electron microscopy with an energy-dispersive X-ray analysis unit. The mass loss and emittance characteristics of the two alloys are discussed.

Wiedemann, K. E.↗

Oxidation and embrittlement of Ti-6Al-2Sn-4Zr-2Mo alloy

A thermogravimetric analysis monitoring study has been conducted for Ti-6Al-2Sn-4Zr-2Mo in the 593-760 C range, with a view to its total oxidation kinetics in laboratory air. In addition, tensile elongation was obtained for selected foil specimens after their exposure to simulated Space Shuttle reentry conditions. The total weight gain with time exhibited two parabolic stages separated by a transient region which is the result of a simultaneous increase in the parabolic growth rate constant for the oxide and in oxygen solubility at the oxide-metal interface. A model for the total oxidation kinetics accounting for the two individual components (oxide growth and solid solution formation) is proposed; the activation energy for oxygen diffusion in the alpha-solid solution is shown to approximate the activation energy for the degradation of tensile elongation of the alloy in its foil gage condition.

Shenoy, R. N.↗