Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Single-beam plasma source deposition of carbon thin films

A single-beam plasma source was developed and used to deposit hydrogenated amorphous carbon (a-C:H) thin films at room temperature. The plasma source was excited by a combined radio frequency and direct current power, which resulted in tunable ion energy over a wide range. The plasma source could effectively dissociate the source hydrocarbon gas and simultaneously emit an ion beam to interact with the deposited film. Using this plasma source and a mixture of argon and C 2 H 2 gas, a-C:H films were deposited at a rate of ~26 nm/min. The resulting a-C:H film of 1.2 µm thick was still highly transparent with a transmittance of over 90% in the infrared range and an optical bandgap of 2.04 eV. Young’s modulus of the a-C:H film was ~80 GPa. The combination of the low-temperature high-rate deposition of transparent a-C:H films with moderately high Young’s modulus makes the single-beam plasma source attractive for many coatings applications, especially in which heat-sensitive and soft materials are involved. Here, the single-beam plasma source can be configured into a linear structure, which could be used for large-area coatings.

14 SOLAR ENERGY↗

Ion Fluxes and Neutral Gas Ionization Efficiency of the 100-kW Light-Ion Helicon Plasma Source Concept for the Material Plasma Exposure eXperiment

Linear plasma devices are cost-effective alternatives for testing materials under reactor-relevant divertor plasma conditions. In this work, we describe how an intense radio-frequency (RF) plasma source concept for the Material Plasma Exposure eXperiment (MPEX) is under development at Oak Ridge National Laboratory. The source concept, Proto-MPEX, aims to produce high-density background deuterium helicon plasmas ( n e > 3 × 10 19 m - 3 ) that are subsequently heated with additional RF and microwave systems to deliver reactor-relevant conditions for studies on plasma-material interaction. In this work, we focus on the plasma-producing stage and its effectiveness in converting input neutral gas into plasma, namely, the neutral gas ionization efficiency. We provide a direct quantitative measurement of the ionization efficiency by measuring the total ion flux arriving at the target region relative to the neutral gas injected at the source. Using 80 kW at 13.56 MHz and a source magnetic field of 0.05 T, the helicon plasma source delivers ion fluxes up to 1 × 10 24 m - 2 s - 1 and heat fluxes greater than 1 M W m - 2 to a target plate located 2 m away from the source. Under these conditions, we observe that the plasma source converts ~89% of the input neutral gas into plasma that arrives at the target as ion flux at a rate of 5 × 10 20 s - 1 . We demonstrate that because of the large pumping capacity of the plasma, neutral gas pumping systems are required only in the target region to maintain optimal plasma operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE POSITION/STRUCTURE STABILITY OF FOUR ICRF2 SOURCES

Four close radio sources in the International Celestial Reference Frame (ICRF) catalog were observed using phase referencing with the VLBA at 43, 23, and 8.6 GHz, and with VERA at 23 GHz over a one-year period. The goal was to determine the stability of the radio cores and to assess structure effects associated with positions in the ICRF. Although the four sources were compact at 8.6 GHz, the VLBA images at 43 GHz with 0.3 mas resolution showed that all were composed of several components. A component in each source was identified as the radio core using some or all of the following emission properties: compactness, spectral index, location at the end of the extended emission region, and stationary in the sky. Over the observing period, the relative positions between the four radio cores were constant to 0.02 mas, the phase-referencing positional accuracy obtained at 23 and 43 GHz among the sources, suggesting that once a radio core is identified, it remains stationary in the sky to this accuracy. Other radio components in two of the four sources had detectable motion in the radio jet direction. Comparison of the 23 and 43 GHz VLBA images with the VLBA 8.6 GHz images and the ICRF positions suggests that some ICRF positions are dominated by a moving jet component; hence, they can be displaced up to 0.5 mas from the radio core and may also reflect the motion of the jet component. Future astrometric efforts to determine a more accurate quasar reference frame at 23 and 43 GHz and from the VLBI2010 project are discussed, and supporting VLBA or European VLBI Network observations of ICRF sources at 43 GHz are recommended in order to determine the internal structure of the sources. A future collaboration between the radio (ICRF) and the optical frame of GAIA is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

SIMULTANEOUS OBSERVATIONS OF SiO AND H{sub 2}O MASERS TOWARD KNOWN STELLAR H{sub 2}O MASER SOURCES

We present the results of simultaneous observations of SiO v = 1, 2, {sup 29}SiO v = 0, J = 1-0, and H{sub 2}O 6{sub 16}-5{sub 23} maser lines toward 152 known stellar H{sub 2}O maser sources using the Yonsei 21 m radio telescope of the Korean VLBI Network from 2009 June to 2011 January. Both SiO and H{sub 2}O masers were detected from 62 sources with a detection rate of 40.8%. The SiO-only maser emission without H{sub 2}O maser detection was detected from 27 sources, while the H{sub 2}O-only maser without SiO maser detection was detected from 22 sources. Therefore, the overall SiO maser emission was detected from 89 sources, resulting in a detection rate of 58.6%. We have identified 70 new detections of the SiO maser emission. For both H{sub 2}O and SiO maser detected sources, the peak and integrated antenna temperatures of SiO masers are stronger than those of H{sub 2}O masers in both Mira variables and OH/IR stars and the relative intensity ratios of H{sub 2}O to SiO masers in OH/IR stars are larger than those in Mira variables. In addition, distributions of 152 observed sources were investigated in the IRAS two-color diagram.

79 ASTRONOMY AND ASTROPHYSICS↗

CONSTRAINING THE REDSHIFT EVOLUTION OF FIRST RADIO SOURCES IN RCS1 GALAXY CLUSTERS

We conduct a statistical analysis of the radio source population in galaxy clusters as a function of redshift by matching radio sources from the Faint Images of the Radio Sky at Twenty-Centimeters catalog with 618 optically selected galaxy clusters from the first Red-Sequence Cluster Survey (RCS1). The total number of excess radio source components (above the background level) per cluster is 0.14 {+-} 0.02 for clusters with 0.35 < z < 0.65 and is 0.10 {+-} 0.02 for clusters with 0.65 < z < 0.95. The richest clusters in the sample have more radio sources than clusters with low or intermediate richness. When we divide our sample into bins according to cluster richness, we do not observe any significant difference (>1.5{sigma}) in the number of radio sources per unit of cluster mass for the galaxy clusters with 0.35 < z < 0.65 as compared to the galaxy clusters with 0.65 < z < 0.95. Thus, the entire sample can be characterized by the number of (L{sub 1.4GHz} > 4.1 x 10{sup 24} W Hz{sup -1}) radio sources per unit (10{sup 14} M{sub sun}) mass, which we measure to be 0.031 {+-} 0.004. We further characterize the population of galaxy cluster-related radio sources through visual inspection of the RCS1 images, finding that although the radio activity of brightest cluster galaxies (BCGs) also does not strongly evolve between our high- and low-redshift samples, the lower-redshift, richest clusters are more likely to host radio-loud BCGs than the higher-redshift, richest clusters or poorer clusters at the 2{sigma} level. We also find evidence that the number of radio-loud cluster members that are not BCGs per cluster per unit mass is higher at high redshift than at low redshift, at the 3{sigma} level.

79 ASTRONOMY AND ASTROPHYSICS↗

FOREGROUND PREDICTIONS FOR THE COSMIC MICROWAVE BACKGROUND POWER SPECTRUM FROM MEASUREMENTS OF FAINT INVERTED RADIO SOURCES AT 5 GHz

We present measurements of a population of matched radio sources at 1.4 and 5 GHz down to a flux limit of 1.5 mJy in 7 deg{sup 2} of the NOAO Deep Field South. We find a significant fraction of sources with inverted spectral indices that all have 1.4 GHz fluxes less than 10 mJy and are therefore too faint to have been detected and included in previous radio source count models that are matched at multiple frequencies. Combined with the matched source population at 1.4 and 5 GHz in 1 deg{sup -2} in the ATESP survey, we update models for the 5 GHz differential number counts and distributions of spectral indices in 5 GHz flux bins that can be used to estimate the unresolved point source contribution to the cosmic microwave background temperature anisotropies. We find a shallower logarithmic slope in the 5 GHz differential counts than in previously published models for fluxes {approx}< 100 mJy as well as larger fractions of inverted spectral indices at these fluxes. Because the Planck flux limit for resolved sources is larger than 100 mJy in all channels, our modified number counts yield at most a 10% change in the predicted Poisson contribution to the Planck temperature power spectrum. For a flux cut of 5 mJy with the South Pole Telescope and a flux cut of 20 mJy with the Atacama Cosmology Telescope, we predict a {approx}30% and {approx}10% increase, respectively, in the radio source Poisson power in the lowest frequency channels of each experiment relative to that predicted by previous models.

79 ASTRONOMY AND ASTROPHYSICS↗

JVLA observations of IC 348 SW: Compact radio sources and their nature

We present sensitive 2.1 and 3.3 cm Jansky Very Large Array radio continuum observations of the region IC 348 SW. We detect a total of 10 compact radio sources in the region, 7 of which are first reported here. One of the sources is associated with the remarkable periodic time-variable infrared source LRLL 54361, opening the possibility of monitoring this object at radio wavelengths. Four of the sources appear to be powering outflows in the region, including HH 211 and HH 797. In the case of the rotating outflow HH 797, we detect a double radio source at its center, separated by ∼3''. Two of the sources are associated with infrared stars that possibly have gyrosynchrotron emission produced in active magnetospheres. Finally, three of the sources are interpreted as background objects.

79 ASTRONOMY AND ASTROPHYSICS↗

CHANDRA OBSERVATIONS OF 3C RADIO SOURCES WITH z < 0.3. II. COMPLETING THE SNAPSHOT SURVEY

We report on the second round of Chandra observations of the 3C snapshot survey developed to observe the complete sample of 3C radio sources with z < 0.3 for 8 ks each. In the first paper, we illustrated the basic data reduction and analysis procedures performed for the 30 sources of the 3C sample observed during Chandra Cycle 9, while here we present the data for the remaining 27 sources observed during Cycle 12. We measured the X-ray intensity of the nuclei and of any radio hot spots and jet features with associated X-ray emission. X-ray fluxes in three energy bands, i.e., soft, medium, and hard, for all the sources analyzed are also reported. For the stronger nuclei, we also applied the standard spectral analysis, which provides the best-fit values of the X-ray spectral index and absorbing column density. In addition, a detailed analysis of bright X-ray nuclei that could be affected by pile-up has been performed. X-ray emission was detected for all the nuclei of the radio sources in our sample except for 3C 319. Among the current sample, there are two compact steep spectrum radio sources, two broad-line radio galaxies, and one wide angle tail radio galaxy, 3C 89, hosted in a cluster of galaxies clearly visible in our Chandra snapshot observation. In addition, we also detected soft X-ray emission arising from the galaxy cluster surrounding 3C 196.1. Finally, X-ray emission from hot spots has been found in three FR II radio sources and, in the case of 3C 459, we also report the detection of X-ray emission associated with the eastern radio lobe as well as X-ray emission cospatial with radio jets in 3C 29 and 3C 402.

79 ASTRONOMY AND ASTROPHYSICS↗

THE WISE BLAZAR-LIKE RADIO-LOUD SOURCES: AN ALL-SKY CATALOG OF CANDIDATE γ-RAY BLAZARS

We present a catalog of radio-loud candidate γ-ray emitting blazars with WISE mid-infrared colors similar to the colors of confirmed γ-ray blazars. The catalog is assembled from WISE sources detected in all four WISE filters, with colors compatible with the three-dimensional locus of the WISE γ-ray emitting blazars, and which can be spatially cross-matched with radio sources from one of the three radio surveys: NVSS, FIRST, and/or SUMSS. Our initial WISE selection uses a slightly modified version of previously successful algorithms. We then select only the radio-loud sources using a measure of the radio-to-IR flux, the q {sub 22} parameter, which is analogous to the q {sub 24} parameter known in the literature but which instead uses the WISE band-four flux at 22 μm. Our final catalog contains 7855 sources classified as BL Lacs, FSRQs, or mixed candidate blazars; 1295 of these sources can be spatially re-associated as confirmed blazars. We describe the properties of the final catalog of WISE blazar-like radio-loud sources and consider possible contaminants. Finally, we discuss why this large catalog of candidate γ-ray emitting blazars represents a new and useful resource to address the problem of finding low-energy counterparts to currently unidentified high-energy sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Angular correlation of cosmic neutrinos with ultrahigh-energy cosmic rays and implications for their sources

Cosmic neutrino events detected by the IceCube Neutrino Observatory with energy 0∼> 3 TeV have poor angular resolutions to reveal their origin. Ultrahigh-energy cosmic rays (UHECRs), with better angular resolutions at 0>6 EeV energies, can be used to check if the same astrophysical sources are responsible for producing both neutrinos and UHECRs. We test this hypothesis, with statistical methods which emphasize invariant quantities, by using data from the Pierre Auger Observatory, Telescope Array and past cosmic-ray experiments. We find that the arrival directions of the cosmic neutrinos are correlated with 0≥ 10 EeV UHECR arrival directions at confidence level ≈ 90%. The strength of the correlation decreases with decreasing UHECR energy and no correlation exists at energy 0∼ 6 EeV . A search in astrophysical databases within 3{sup o} of the arrival directions of UHECRs with energy 0≥ 10 EeV, that are correlated with the IceCube cosmic neutrinos, resulted in 18 sources from the Swift-BAT X-ray catalog with redshift z≤ 0.06. We also found 3 objects in the Kühr catalog of radio sources using the same criteria. The sources are dominantly Seyfert galaxies with Cygnus A being the most prominent member. We calculate the required neutrino and UHECR fluxes to produce the observed correlated events, and estimate the corresponding neutrino luminosity (25 TeV–2.2 PeV) and cosmic-ray luminosity (500 TeV–180 EeV), assuming the sources are the ones we found in the Swift-BAT and Kühr catalogs. We compare these luminosities with the X-ray luminosity of the corresponding sources and discuss possibilities of accelerating protons to 0∼> 10 EeV and produce neutrinos in these sources.

79 ASTRONOMY AND ASTROPHYSICS↗

OPTICAL STUDY OF THE HYPER-LUMINOUS X-RAY SOURCE 2XMM J011942.7+032421

We present the identification and characterization of the optical counterpart to 2XMM J011942.7+032421, one of the most luminous and distant ultra-luminous X-ray sources (ULXs). The counterpart is located near a star-forming region in a spiral arm of the galaxy NGC 470 with u, g, and r magnitudes of 21.53, 21.69, and 21.71 mag, respectively. The luminosity of the counterpart is much larger than that of a single O-type star, indicating that it may be a stellar cluster. Our optical spectroscopic observations confirm the association of the X-ray source and the optical counterpart with its host galaxy NGC 470, which validates the high, ≳10{sup 41} erg s{sup -1}, X-ray luminosity of the source. Its optical spectrum is embedded with numerous emission lines, including H recombination lines, metallic forbidden lines, and more notably the high-ionization He II (λ4686) line. That line shows a large velocity dispersion of ≅410 km s{sup -1}, consistent with the existence of a compact (<5 AU) highly ionized accretion disk rotating around the central X-ray source. The ∼1.4 × 10{sup 37} erg s{sup -1} luminosity of the He II line emission makes the source one of the most luminous ULXs in that emission. This, together with the high X-ray luminosity and the large velocity dispersion of the He II emission, suggests that the source is an ideal candidate for more extensive follow-up observations for understanding the nature of hyper-luminous X-ray sources, a more luminous subgroup of ULXs, and more likely candidates for intermediate-mass black holes.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic Radioactive Source for Evaluating and Demonstrating Time-dependent Performance of Continuous Air Monitors

Evaluation of continuous air monitors in the presence of a plutonium aerosol is time intensive, expensive, and requires a specialized facility. The Radiation Protection Services Group at Los Alamos National Laboratory has designed a Dynamic Radioactive Source, intended to replace plutonium aerosol challenge testing. Furthermore, the Dynamic Radioactive Source is small enough to be inserted into the sampler filter chamber of a typical continuous air monitor. Time-dependent radioactivity is introduced from electroplated sources for real-time testing of a continuous air monitor where a mechanical wristwatch motor rotates a mask above an alpha-emitting electroplated disk source. The mask is attached to the watch’s minute hand, and as it rotates, more of the underlying source is revealed. The alpha activity we measured increases with time, simulating the arrival of airborne radioactive particulates at the air sampler inlet. The Dynamic Radioactive Source allows the temporal behavior of puff and chronic release conditions to be mimicked without the need for radioactive aerosols. The new system is configurable to different continuous air monitor designs and provides an in-house testing capability (benchtop compatible). It is a repeatable and reusable system and does not contaminate the tested air monitor. Test benefits include direct user control, realistic (plutonium) aerosol spectra, and iterative development of continuous air monitor alarm algorithms. We also used data obtained using the Dynamic Radioactive Source to elucidate alarm algorithms and to compare the response time of two commercial continuous air monitors.

07 ISOTOPE AND RADIATION SOURCES↗

Time-Integrated Neutrino Source Searches with 10 Years of IceCube Data

This Letter presents the results from pointlike neutrino source searches using ten years of IceCube data collected between April 6, 2008 and July 10, 2018. We evaluate the significance of an astrophysical signal from a pointlike source looking for an excess of clustered neutrino events with energies typically above ~1 TeV among the background of atmospheric muons and neutrinos. We perform a full-sky scan, a search within a selected source catalog, a catalog population study, and three stacked Galactic catalog searches. The most significant point in the northern hemisphere from scanning the sky is coincident with the Seyfert II galaxy NGC 1068, which was included in the source catalog search. The excess at the coordinates of NGC 1068 is inconsistent with background expectations at the level of 2.9σ after accounting for statistical trials from the entire catalog. The combination of this result along with excesses observed at the coordinates of three other sources, including TXS 0506+056, suggests that, collectively, correlations with sources in the northern catalog are inconsistent with background at 3.3σ significance. The southern catalog is consistent with background. Finally these results, all based on searches for a cumulative neutrino signal integrated over the 10 years of available data, motivate further study of these and similar sources, including time-dependent analyses, multimessenger correlations, and the possibility of stronger evidence with coming upgrades to the detector.

79 ASTRONOMY AND ASTROPHYSICS↗

A matrix-inversion method for gamma-source mapping from gamma-count data

In a previous paper it was proposed that a simple matrix inversion method could be used to extract source distributions from gamma-count maps, using simple models to calculate the response matrix. The method was tested using numerically generated count maps. In the present work a 100 kBq Co{sup 60} source has been placed on a gridded surface and the count rate measured using a NaI scintillation detector. The resulting map of gamma counts was used as input to the matrix inversion procedure and the source position recovered. A multi-source array was simulated by superposition of several single-source count maps and the source distribution was again recovered using matrix inversion. The measurements were performed for several detector heights. The effects of uncertainties in source-detector distances on the matrix inversion method are also examined. The results from this work give confidence in the application of the method to practical applications, such as the segregation of highly active objects amongst fuel-element debris. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deconvolution by finite-size-source effects of x-ray phase-contrast images

Purpose: In the hard x-ray region, the cross sections for the phase shift of low-Z elements are about 1000 times larger than the absorption ones. As a consequence, phase contrast is detectable even when absorption contrast is minimal or absent. Therefore, phase-contrast imaging could become a valid alternative to absorption contrast without delivering high dose to tissue/human body parts. Methods: To enhance the quality of phase-contrast images without increasing the dose, a possible approach could be the partial deconvolution of the finite source size effects by experimental phase-contrast images. The deconvolution procedure, the authors propose, employs the acquisition of two images on a suitable well-known test sample, one in contact and the other in phase-contrast conditions. Both acquired images are used along with a simulated phase-contrast image (obtained from the test sample in ideal conditions of pointlike source illumination) to correctly retrieve the experimental source distribution function. This information allows a generic experimental phase-contrast image, acquired in the same conditions, to be partially deconvolved by finite source size effects. Results: The performed experimental tests indicate that deconvolved images are equivalent to those which would be obtained with a source 40% smaller than the actual size. In turn, this finding is equivalent to an increase of the ''effective'' lateral spatial coherence length. The corresponding quality improvement of the phase-contrast imaging is directly deducible by the presence of many Fresnel fringes, much better visible with respect to the original experimental phase-contrast images. Conclusions: The use of a test standard sample, always possible in every experimental setup, to partially deconvolve the finite-size-source blurring effects shows that higher quality phase-contrast images could be readily available, making easier diagnoses and tissue/sample analyses. The method could give, in the future, the possibility to further lower the delivered dose to patients, organs, and tissues when compact room-sized and brilliant microfocus x-ray sources will be available for clinical applications in hospitals.

60 APPLIED LIFE SCIENCES↗

SU-E-T-212: Comparison of TG-43 Dosimetric Parameters of Low and High Energy Brachytherapy Sources Obtained by MCNP Code Versions of 4C, X and 5

Purpose: Different versions of MCNP code are widely used for dosimetry purposes. The purpose of this study is to compare different versions of the MCNP codes in dosimetric evaluation of different brachytherapy sources. Methods: The TG-43 parameters such as dose rate constant, radial dose function, and anisotropy function of different brachytherapy sources, i.e. Pd-103, I-125, Ir-192, and Cs-137 were calculated in water phantom. The results obtained by three versions of Monte Carlo codes (MCNP4C, MCNPX, MCNP5) were compared for low and high energy brachytherapy sources. Then the cross section library of MCNP4C code was changed to ENDF/B-VI release 8 which is used in MCNP5 and MCNPX codes. Finally, the TG-43 parameters obtained using the MCNP4C-revised code, were compared with other codes. Results: The results of these investigations indicate that for high energy sources, the differences in TG-43 parameters between the codes are less than 1% for Ir-192 and less than 0.5% for Cs-137. However for low energy sources like I-125 and Pd-103, large discrepancies are observed in the g(r) values obtained by MCNP4C and the two other codes. The differences between g(r) values calculated using MCNP4C and MCNP5 at the distance of 6cm were found to be about 17% and 28% for I-125 and Pd-103 respectively. The results obtained with MCNP4C-revised and MCNPX were similar. However, the maximum difference between the results obtained with the MCNP5 and MCNP4C-revised codes was 2% at 6cm. Conclusion: The results indicate that using MCNP4C code for dosimetry of low energy brachytherapy sources can cause large errors in the results. Therefore it is recommended not to use this code for low energy sources, unless its cross section library is changed. Since the results obtained with MCNP4C-revised and MCNPX were similar, it is concluded that the difference between MCNP4C and MCNPX is their cross section libraries.

60 APPLIED LIFE SCIENCES↗

A method for verification of treatment delivery in HDR prostate brachytherapy using a flat panel detector for both imaging and source tracking

Purpose: Verification of high dose rate (HDR) brachytherapy treatment delivery is an important step, but is generally difficult to achieve. A technique is required to monitor the treatment as it is delivered, allowing comparison with the treatment plan and error detection. In this work, we demonstrate a method for monitoring the treatment as it is delivered and directly comparing the delivered treatment with the treatment plan in the clinical workspace. This treatment verification system is based on a flat panel detector (FPD) used for both pre-treatment imaging and source tracking. Methods: A phantom study was conducted to establish the resolution and precision of the system. A pretreatment radiograph of a phantom containing brachytherapy catheters is acquired and registration between the measurement and treatment planning system (TPS) is performed using implanted fiducial markers. The measured catheter paths immediately prior to treatment were then compared with the plan. During treatment delivery, the position of the {sup 192}Ir source is determined at each dwell position by measuring the exit radiation with the FPD and directly compared to the planned source dwell positions. Results: The registration between the two corresponding sets of fiducial markers in the TPS and radiograph yielded a registration error (residual) of 1.0 mm. The measured catheter paths agreed with the planned catheter paths on average to within 0.5 mm. The source positions measured with the FPD matched the planned source positions for all dwells on average within 0.6 mm (s.d. 0.3, min. 0.1, max. 1.4 mm). Conclusions: We have demonstrated a method for directly comparing the treatment plan with the delivered treatment that can be easily implemented in the clinical workspace. Pretreatment imaging was performed, enabling visualization of the implant before treatment delivery and identification of possible catheter displacement. Treatment delivery verification was performed by measuring the source position as each dwell was delivered. This approach using a FPD for imaging and source tracking provides a noninvasive method of acquiring extensive information for verification in HDR prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

Automated High Power Permanent Borehole Seismic Source Systems for Long-Term Monitoring of Subsurface CO2 Containment and Storage

The geologic storage of CO2 emitted from fixed sources, such as coal or gas power plants, is currently considered one of the prime technologies for short term (~50 year) mitigation of greenhouse gas emissions. The subsurface storage of CO2 for greenhouse gas mitigation will require monitoring to verify that CO2 remains effectively trapped underground, thus permanent seismic sources are needed to provide 24/7 monitoring. GPUSA Inc. has developed and successfully demonstrated numerous prototype vibratory seismic sources with power and performance far beyond any available on the market. The primary objective of this project was to validate in an operational field environment GPUSA’s powerful, low cost, automated borehole seismic source systems for the CO2 storage monitoring application. GPUSA originally proposed the building and testing of two types of permanent sources but ended up building and delivering three types of permanent seismic sources. These sources were delivered to the field test site (Carbon Management Canada’s Containment and Monitoring site near Calgary), however, only two of the systems were able to be tested before the contract ended (despite two contract extensions). The reasons for the delay were primarily weather related both at the US preliminary field test site and Carbon Management Canada site. But in the end, based upon the preliminary field testing in the US and the limited testing that was completed at the Carbon Management Canada site, the results were very impressive, and in some cases far exceeding expectations.

02 PETROLEUM↗