Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL CONDITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

A miniaturized neuroprosthesis suitable for implantation into the brain

This paper presents current research on a miniaturized neuroprosthesis suitable for implantation into the brain. The prosthesis is a heterogeneous integration of a 100-element microelectromechanical system (MEMS) electrode array, front-end complementary metal-oxide-semiconductor (CMOS) integrated circuit for neural signal preamplification, filtering, multiplexing and analog-to-digital conversion, and a second CMOS integrated circuit for wireless transmission of neural data and conditioning of wireless power. The prosthesis is intended for applications where neural signals are processed and decoded to permit the control of artificial or paralyzed limbs. This research, if successful, will allow implantation of the electronics into the brain, or subcutaneously on the skull, and eliminate all external signal and power wiring. The neuroprosthetic system design has strict size and power constraints with each of the front-end preamplifier channels fitting within the 400 x 400-microm pitch of the 100-element MEMS electrode array and power dissipation resulting in less than a 1 degree C temperature rise for the surrounding brain tissue. We describe the measured performance of initial micropower low-noise CMOS preamplifiers for the neuroprosthetic.

Action Potentials/physiology↗

Uncertainty Quantification of Capacitor Switching Transient Location using Machine Learning

Identification of capacitor switching transient location provides valuable insight into the state of the associated equipment. Machine learning (ML) models, and convolutional neural networks (CNNs) in particular, have demonstrated remarkable performance in signal location. However, ML models are data driven whose predictions are affected by noise in data and may also suffer from large extrapolation errors when applied to new conditions. Uncertainty quantification (UQ) is necessary to ensure model trustworthiness and avoid overconfident predictions in extrapolation. Here, in this work, we propose a novel UQ method, called PI3NN, to quantify prediction uncertainty of ML models and integrate the method with CNNs for transient source location. PI3NN calculates Prediction Intervals by training 3 Neural Networks and uses root-finding methods to determine the interval precisely. Additionally, PI3NN can identify out-of-distribution (OOD) data in a nonstationary condition to avoid overconfident prediction. Results indicate that with PI3NN, transient signals are not only correctly identified, but when said signals are subject to corruptions characteristic of an actual power monitoring system (e.g. non-ideal sensors), the model recognizes when it is uncertain about its predictions, effectively letting the user know when to accept or discard the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An investigation of signal performance enhancements achieved through innovative pixel design across several generations of indirect detection, active matrix, flat-panel arrays

Active matrix flat-panel imager (AMFPI) technology is being employed for an increasing variety of imaging applications. An important element in the adoption of this technology has been significant ongoing improvements in optical signal collection achieved through innovations in indirect detection array pixel design. Such improvements have a particularly beneficial effect on performance in applications involving low exposures and/or high spatial frequencies, where detective quantum efficiency is strongly reduced due to the relatively high level of additive electronic noise compared to signal levels of AMFPI devices. In this article, an examination of various signal properties, as determined through measurements and calculations related to novel array designs, is reported in the context of the evolution of AMFPI pixel design. For these studies, dark, optical, and radiation signal measurements were performed on prototype imagers incorporating a variety of increasingly sophisticated array designs, with pixel pitches ranging from 75 to 127 {mu}m. For each design, detailed measurements of fundamental pixel-level properties conducted under radiographic and fluoroscopic operating conditions are reported and the results are compared. A series of 127 {mu}m pitch arrays employing discrete photodiodes culminated in a novel design providing an optical fill factor of {approx}80% (thereby assuring improved x-ray sensitivity), and demonstrating low dark current, very low charge trapping and charge release, and a large range of linear signal response. In two of the designs having 75 and 90 {mu}m pitches, a novel continuous photodiode structure was found to provide fill factors that approach the theoretical maximum of 100%. Both sets of novel designs achieved large fill factors by employing architectures in which some, or all of the photodiode structure was elevated above the plane of the pixel addressing transistor. Generally, enhancement of the fill factor in either discrete or continuous photodiode arrays was observed to result in no degradation in MTF due to charge sharing between pixels. While the continuous designs exhibited relatively high levels of charge trapping and release, as well as shorter ranges of linearity, it is possible that these behaviors can be addressed through further refinements to pixel design. Both the continuous and the most recent discrete photodiode designs accommodate more sophisticated pixel circuitry than is present on conventional AMFPIs - such as a pixel clamp circuit, which is demonstrated to limit signal saturation under conditions corresponding to high exposures. It is anticipated that photodiode structures such as the ones reported in this study will enable the development of even more complex pixel circuitry, such as pixel-level amplifiers, that will lead to further significant improvements in imager performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

Increased chromatin plasticity supports enhanced metastatic potential of mouse melanoma cells

Metastasis formation is strongly dependent on the migration capabilities of tumor cells. Recently it has become apparent that nuclear structure and morphology affect the cellular ability to migrate. Previously we found that migration of melanoma cells is both associated with and dependent on global chromatin condensation. Therefore, we anticipated that tumor progression would be associated with increased chromatin condensation. Interestingly, the opposite has been reported for melanoma. In trying to resolve this contradiction, we show that during growth conditions, tumor progression is associated with global chromatin de-condensation that is beneficial for faster proliferation. However, upon induction of migration, in both low- and high-metastatic mouse melanoma cells chromatin undergoes condensation to support cell migration. Our results reveal that throughout tumor progression induction of chromatin condensation by migration signals is maintained, whereas the organization of chromatin during growth conditions is altered. Thus, tumor progression is associated with an increase in chromatin dynamics. - Highlights: • In the B16 melanoma model higher aggressiveness is linked to chromatin decondensation. • High levels of condensed chromatin reduce the cellular proliferation rate. • Migration signals induce chromatin condensation in low and high metastatic B16 cells. • Migration of low and high metastatic B16 cells is dependent on chromatin condensation.

60 APPLIED LIFE SCIENCES↗

Visualizing ultrasound through computational modeling

The Doppler Ultrasound Hematocrit Project (DHP) hopes to find non-invasive methods of determining a person s blood characteristics. Because of the limits of microgravity and the space travel environment, it is important to find non-invasive methods of evaluating the health of persons in space. Presently, there is no well developed method of determining blood composition non-invasively. This projects hopes to use ultrasound and Doppler signals to evaluate the characteristic of hematocrit, the percentage by volume of red blood cells within whole blood. These non-invasive techniques may also be developed to be used on earth for trauma patients where invasive measure might be detrimental. Computational modeling is a useful tool for collecting preliminary information and predictions for the laboratory research. We hope to find and develop a computer program that will be able to simulate the ultrasound signals the project will work with. Simulated models of test conditions will more easily show what might be expected from laboratory results thus help the research group make informed decisions before and during experimentation. There are several existing Matlab based computer programs available, designed to interpret and simulate ultrasound signals. These programs will be evaluated to find which is best suited for the project needs. The criteria of evaluation that will be used are 1) the program must be able to specify transducer properties and specify transmitting and receiving signals, 2) the program must be able to simulate ultrasound signals through different attenuating mediums, 3) the program must be able to process moving targets in order to simulate the Doppler effects that are associated with blood flow, 4) the program should be user friendly and adaptable to various models. After a computer program is chosen, two simulation models will be constructed. These models will simulate and interpret an RF data signal and a Doppler signal.

Guo, Theresa W.↗

A systems biology perspective on Nrf2-mediated antioxidant response

Cells in vivo are constantly exposed to reactive oxygen species (ROS) generated endogenously and exogenously. To defend against the deleterious consequences of ROS, cells contain multiple antioxidant enzymes expressed in various cellular compartments to scavenge these toxic species. Under oxidative stresses, these antioxidant enzymes are upregulated to restore redox homeostasis. Such an adaptive response results from the activation of a redox-sensitive gene regulatory network mediated by nuclear factor E2-related factor 2. To more completely understand how the redox control system is designed by nature to meet homeostatic goals, we have examined the network from a systems perspective using engineering approaches. As with man-made control devices, the redox control system can be decomposed into distinct functional modules, including transducer, controller, actuator, and plant. Cells achieve specific performance objectives by utilizing nested feedback loops, feedforward control, and ultrasensitive signaling motifs, etc. Given that endogenously generated ROS are also used as signaling molecules, our analysis suggests a novel mode of action to explain oxidative stress-induced pathological conditions and diseases. Specifically, by adaptively upregulating antioxidant enzymes, oxidative stress may inadvertently attenuate ROS signals that mediate physiological processes, resulting in aberrations of cellular functions and adverse consequences. Lastly, by simultaneously considering the two competing cellular tasks-adaptive antioxidant defense and ROS signaling-we re-examine the premise that dietary antioxidant supplements is generally beneficial to human health. Our analysis highlights some possible adverse effects of these widely consumed antioxidants.

60 APPLIED LIFE SCIENCES↗

Systems and methods of monitoring acoustic pressure to detect a flame condition in a gas turbine

A method may detect a flashback condition in a fuel nozzle of a combustor. The method may include obtaining a current acoustic pressure signal from the combustor, analyzing the current acoustic pressure signal to determine current operating frequency information for the combustor, and indicating that the flashback condition exists based at least in part on the current operating frequency information.

42 ENGINEERING↗

The Application of Fiber Optic Wavelength Division Multiplexing in RF Avionics

This paper demonstrates a successful application of wavelength division multiplexing (WDM) to the avionics environment to support analog RF signal transmission. We investigate the simultaneous transmission of four RF signals (channels) over a single optical fiber. These four analog channels are sequentially multiplexed and demultiplexed at different points along a fiber optic backbone to more closely emulate the conditions found onboard aircraft. We present data from measurements of signal-to-noise ratio (SNR), transmission response (loss and gain), group delay that defines phase distortion, and dynamic range that defines nonlinear distortion. The data indicate that WDM is well-suited for avionics applications.

Ngo, Duc↗

Comment on 'Coherence measures for heralded single-photon sources'

A recent Brief Report [Phys. Rev. A 79, 035801 (2009)] investigates two figures of merit for heralded photon sources based on spontaneous parametric down-conversion with a continuous pump, namely, the time-averaged temporal coherence between the signal and idler beams and the time-averaged conditioned second-order degree of coherence for photons in the heralded arm. However, contrary to what is claimed, no one-arm second-order effect is actually measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gain and offset calibration reduces variation in exposure-dependent SNR among systems with identical digital flat-panel detectors

Purpose: The conditions under which vendor performance criteria for digital radiography systems are obtained do not adequately simulate the conditions of actual clinical imaging with respect to radiographic technique factors, scatter production, and scatter control. Therefore, the relationship between performance under ideal conditions and performance in clinical practice remains unclear. Using data from a large complement of systems in clinical use, the authors sought to develop a method to establish expected performance criteria for digital flat-panel radiography systems with respect to signal-to-noise ratio (SNR) versus detector exposure under clinical conditions for thoracic imaging. Methods: The authors made radiographic exposures of a patient-equivalent chest phantom at 125 kVp and 180 cm source-to-image distance. The mAs value was modified to produce exposures above and below the mAs delivered by automatic exposure control. Exposures measured free-in-air were corrected to the imaging plane by the inverse square law, by the attenuation factor of the phantom, and by the Bucky factor of the grid for the phantom, geometry, and kilovolt peak. SNR was evaluated as the ratio of the mean to the standard deviation (SD) of a region of interest automatically selected in the center of each unprocessed image. Data were acquired from 18 systems, 14 of which were tested both before and after gain and offset calibration. SNR as a function of detector exposure was interpolated using a double logarithmic function to stratify the data into groups of 0.2, 0.5, 1.0, 2.0, and 5.0 mR exposure (1.8, 4.5, 9.0, 18, and 45 {mu}Gy air KERMA) to the detector. Results: The mean SNR at each exposure interval after calibration exhibited linear dependence on the mean SNR before calibration (r{sup 2} = 0.9999). The dependence was greater than unity (m = 1.101 {+-} 0.006), and the difference from unity was statistically significant (p < 0.005). The SD of mean SNR after calibration also exhibited linear dependence on the SD of the mean SNR before calibration (r{sup 2} = 0.9997). This dependence was less than unity (m = 0.822 {+-} 0.008), and the difference from unity was also statistically significant (p < 0.005). Systems were separated into two groups: systems with a precalibration SNR higher than the median SNR (N = 7), and those with a precalibration SNR lower than the median SNR (N = 7). Posthoc analysis was performed to correct for expanded false positive results. After calibration, the authors noted differences in mean SNR within both high and low groups, but these differences were not statistically significant at the 0.05 level. SNR data from four additional systems and one system from those previously tested after replacement of its detector were compared to the 95% confidence intervals (CI) calculated from the postcalibration SNR data. The comparison indicated that four of these five systems were consistent with the CI derived from the previously tested 14 systems after calibration. Two systems from the paired group that remained outside the CI were studied further. One system was remedied with a grid replacement. The nonconformant behavior of the other system was corrected by replacing the image receptor. Conclusions: Exposure-dependent SNR measurements under conditions simulating thoracic imaging allowed us to develop criteria for digital flat-panel imaging systems from a single manufacturer. These measurements were useful in identifying systems with discrepant performance, including one with a defective grid, one with a defective detector, and one that had not been calibrated for gain and offset. The authors also found that the gain and offset calibration reduces variation in exposure-dependent SNR performance among the systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel Non‐Destructive Rapid Tool for Estimating Amino Acid Composition and Secondary Structures of Proteins in Solution

Abstract Amino‐acid protein composition plays an important role in biology, medicine, and nutrition. Here, a groundbreaking protein analysis technique that quickly estimates amino acid composition and secondary structure across various protein sizes, while maintaining their natural states is introduced and validated. This method combines multivariate statistics and the thermostable Raman interaction profiling (TRIP) technique, eliminating the need for complex preparations. In order to validate the approach, the Raman spectra are constructed of seven proteins of varying sizes by utilizing their amino acid frequencies and the Raman spectra of individual amino acids. These constructed spectra exhibit a close resemblance to the actual measured Raman spectra. Specific vibrational modes tied to free amino and carboxyl termini of the amino acids disappear as signals linked to secondary structures emerged under TRIP conditions. Furthermore, the technique is used inversely to successfully estimate amino acid compositions and secondary structures of unknown proteins across a range of sizes, achieving impressive accuracy ranging between 1.47% and 5.77% of root mean square errors (RMSE). These results extend the uses for TRIP beyond interaction profiling, to probe amino acid composition and structure.

Chemistry↗

Quantifying the Chiral Magnetic Effect from Anomalous-Viscous Fluid Dynamics

In this contribution we report a recently developed Anomalous-Viscous Fluid Dynamics (AVFD) framework, which simulates the evolution of fermion currents in QGP on top of the bulk expansion from data-validated VISHNU hydrodynamics. With reasonable estimates of initial conditions and magnetic field lifetime, the predicted CME signal is quantitatively consistent with change separation measurements in 200GeV Au-Au collisions at RHIC. We further develop the event-by-event AVFD simulations that allow direct evaluation of two-particle correlations arising from CME signal as well as the non-CME backgrounds. Lastly we report predictions from AVFD simulations for the upcoming isobaric (Ru-Ru v.s. Zr-Zr ) collisions that could provide the critical test of the CME in heavy ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Diurnal Variation of the Aerosol Optical Depth at the ARM SGP Site

Abstract This study examines the diurnal variation of the aerosol optical depth (AOD) at 355 nm observed by Raman lidar (RL) at the Atmospheric Radiation Measurement Program Southern Great Plains (SGP) site under both clear and cloudy‐sky conditions. Here only cloudy‐skies when the lidar signal is not fully attenuated are considered. The daytime AOD and its variation from the RL showed an excellent agreement with the Aerosol Robotic Network, demonstrating that the RL‐retrieved AOD is not affected by solar background contamination. The climatological annual‐mean daytime‐mean AOD is only slightly larger than the nighttime‐mean AOD (by 1%–3%). However, day‐to‐day variations are observed such that the daytime‐ and nighttime‐mean AOD difference for a given day can be large (about 95% of days have differences within 0.2). The seasonal AOD diurnal range (i.e., the difference between the maximum and minimum values) relative to the mean was 10%–15% except in the winter when it was 44%. The seasonal‐mean cloudy‐sky AOD diurnal variation is similar to that for clear‐sky, except that the AODs are larger (the annual‐mean cloudy‐sky AOD is larger than the clear‐sky by 24%). The aerosol lidar ratio diurnal variations are also examined, which are 10%–20% for all seasons with a minimum near 9 a.m. to 15 p.m. for all seasons except winter. Also presented is the annual‐mean AOD from the Cloud‐Aerosol Lidar and Infrared Pathfinder Satellite at SGP site: its daytime AOD is about 0.1 smaller than nighttime AOD because of daytime solar background contamination.

54 ENVIRONMENTAL SCIENCES↗

Rapid spin changes around a magnetar fast radio burst

Magnetars are neutron stars with extremely high magnetic fields (≳10 14 gauss) that exhibit various X-ray phenomena such as sporadic subsecond bursts, long-term persistent flux enhancements and variable rotation-period derivative. In 2020, a fast radio burst (FRB), akin to cosmological millisecond-duration radio bursts, was detected from the Galactic magnetar SGR 1935+2154, confirming the long-suspected association between some FRBs and magnetars. However, the mechanism for FRB generation in magnetars remains unclear. Here we report the X-ray observation of two glitches in SGR 1935+2154 within a time interval of approximately nine hours, bracketing an FRB that occurred on 14 October 2022. Each glitch involved a significant increase in the magnetar’s spin frequency, being among the largest abrupt changes in neutron-star rotation observed so far. Between the glitches, the magnetar exhibited a rapid spin-down phase, accompanied by an increase and subsequent decline in its persistent X-ray emission and burst rate. Here we postulate that a strong, ephemeral, magnetospheric wind provides the torque that rapidly slows the star’s rotation. The trigger for the first glitch couples the star’s crust to its magnetosphere, enhances the various X-ray signals and spawns the wind that alters magnetospheric conditions that might produce the FRB.

79 ASTRONOMY AND ASTROPHYSICS↗

BeyondPlanck: VII. Bayesian estimation of gain and absolute calibration for cosmic microwave background experiments

We present a Bayesian calibration algorithm for cosmic microwave background (CMB) observations as implemented within the global end-to-end BEYONDPLANCK framework and applied to the Planck Low Frequency Instrument (LFI) data. Following the most recent Planck analysis, we decomposed the full time-dependent gain into a sum of three nearly orthogonal components: one absolute calibration term, common to all detectors, one time-independent term that can vary between detectors, and one time-dependent component that was allowed to vary between one-hour pointing periods. Each term was then sampled conditionally on all other parameters in the global signal model through Gibbs sampling. The absolute calibration is sampled using only the orbital dipole as a reference source, while the two relative gain components were sampled using the full sky signal, including the orbital and Solar CMB dipoles, CMB fluctuations, and foreground contributions. We discuss various aspects of the data that influence gain estimation, including the dipole-polarization quadrupole degeneracy and processing masks. Comparing our solution to previous pipelines, we find good agreement in general, with relative deviations of -0.67% (-0.84%) for 30 GHz, 0.12% (-0.04%) for 44 GHz and -0.03% (-0.64%) for 70 GHz, compared to Planck PR4 and Planck 2018, respectively. We note that the BEYONDPLANCK calibration was performed globally, which results in better inter-frequency consistency than previous estimates. Additionally, WMAP observations were used actively in the BEYONDPLANCK analysis, which both breaks internal degeneracies in the Planck data set and results in an overall better agreement with WMAP. Finally, we used a Wiener filtering approach to smoothing the gain estimates. We show that this method avoids artifacts in the correlated noise maps as a result of oversmoothing the gain solution, which is difficult to avoid with methods like boxcar smoothing, as Wiener filtering by construction maintains a balance between data fidelity and prior knowledge. Although our presentation and algorithm are currently oriented toward LFI processing, the general procedure is fully generalizable to other experiments, as long as the Solar dipole signal is available to be used for calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

First real-time detection of surface dust in a tokamak

The first real-time detection of surface dust inside a tokamak was made using an electrostatic dust detector. A fine grid of interlocking circuit traces was installed in the NSTX vessel and biased to 50 V. Impinging dust particles created a temporary short circuit and the resulting current pulse was recorded by counting electronics. The techniques used to increase the detector sensitivity by a factor of x10 000 to match NSTX dust levels while suppressing electrical pickup are presented. The results were validated by comparison to laboratory measurements, by the null signal from a covered detector that was only sensitive to pickup, and by the dramatic increase in signal when Li particles were introduced for wall conditioning purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗