Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Active Structural Acoustic Control of Interior Noise on a Raytheon 1900D

An active structural acoustic control system has been demonstrated on a Raytheon Aircraft Company 1900D turboprop airliner. Both single frequency and multi-frequency control of the blade passage frequency and its harmonics was accomplished. The control algorithm was a variant of the popular filtered-x LMS implemented in the principal component domain. The control system consisted of 21 inertial actuators and 32 microphones. The actuators were mounted to the aircraft's ring frames. The microphones were distributed uniformly throughout the interior at head height, both seated and standing. Actuator locations were selected using a combinatorial search optimization algorithm. The control system achieved a 14 dB noise reduction of the blade passage frequency during single frequency tests. Multi-frequency control of the first 1st, 2nd and 3rd harmonics resulted in 10.2 dB, 3.3 dB and 1.6 dB noise reductions respectively. These results fall short of the predictions which were produced by the optimization algorithm (13.5 dB, 8.6 dB and 6.3 dB). The optimization was based on actuator transfer functions taken on the ground and it is postulated that cabin pressurization at flight altitude was a factor in this discrepancy.

Palumbo, Dan↗

An Examination of the U.S. Regional Airline Policies Regarding Child Restraint Systems

A prior study examined the policies of U.S. air carriers with regard to the use of infant restraint systems on board commercial aircraft. This study expands on that earlier study by examining the policies of commuter air carriers in the United States regarding the use of infant restraint systems. The management policy of the commuter air carriers has been investigated and officials of the commuter air carriers were surveyed to determine how the carriage of infants onboard their aircraft varied among commuter airlines. The topics investigated included seat space for infants, restraint systems for infants, and amenities for infant passengers. The results of this study have been analyzed to ascertain if any recommendations can be made to the commuter airlines regarding the carriage of infants onboard their aircraft.

Carstenson, Larry↗

Determining Usability Versus Cost and Yields of a Regional Transport

Regional transports are designed to operate on air networks having the basic characteristics of short trip distances and low density passengers/cargo, i.e. small numbers of passengers per flight. Regional transports passenger capacity is from 10 to 100 seats and operate on routes from 350 to 1000 nautical miles (nm). An air network operated by regional transports has the following characteristics: (1) connecting regional centers; (2) operating on low density passengers/cargo flow services with minimum two frequencies per day; (3) operating on high density passengers/cargo flow with more than two frequencies per day; and (4) operating supplemental services whenever market demands in order to help bigger capacity aircraft already operating the same routes. In order to meet passenger requirements providing low fares and high or required number of frequencies, airlines must constantly monitor operational costs and keep them low. It is obvious that costs of operating aircraft must be lower than yield obtained by transporting passengers and cargo. The requirement to achieve favorable yield/cost ratio must provide the answer to the question of which aircraft will best meet a specific air network. An air network is defined by the number of services, the trip distance of each service, and the number of flights (frequencies) per day and week.

Gvozdenovic, Slobodan↗

Ignition Resistance of Polymeric Materials to Particle Impact in High-Pressure Oxygen

Particle impact ignition has been the primary cause of numerous fires in oxygen systems. This ignition phenomenon is known to occur where particles are present in high-velocity gas, and where impact occurs on a flammable material. The particle impact ignition behavior of many metals has been widely studied, but the particle impact ignition behavior of polymeric materials is relatively unknown. Particle impact ignition in polymeric materials is a concern as these materials are commonly used in component seat and seal applications, where high-velocity particle impacts can occur. This study evaluates several polymeric materials and compares the minimum temperature required for ignition (threshold temperature) of these materials: Kel-F 81 (CTFE), Teflon (PTFE), PEEK, Vespel SP-21, and Nylon 6/6. The materials were configured as targets in the White Sands Test Facility high-velocity particle impact test system. Gaseous oxygen was flowed at 4000 psi and sonic velocity, and the targets were impacted with 2000-micron aluminum 2017 particles. This paper discusses the results of these tests and ranks the materials according to their threshold temperatures at these conditions.

Forsyth, Elliot T.↗

Orthostatic Intolerance and Motion Sickness After Parabolic Flight

Orthostatic intolerance is common in astronauts after prolonged space flight. However, the "push-pull effect" in military aviators suggests that brief exposures to transitions between hypo- and hypergravity are sufficient to induce untoward autonomic cardiovascular physiology in susceptible individuals. We therefore investigated orthostatic tolerance and autonomic cardiovascular function in 16 healthy test subjects before and after a seated 2-hr parabolic flight. At the same time, we also investigated relationships between parabolic flight-induced vomiting and changes in orthostatic and autonomic cardiovascular function. After parabolic flight, 8 of 16 subjects could not tolerate a 30-min upright tilt test, compared to 2 of 16 before flight. Whereas new intolerance in non-Vomiters resembled the clinical postural tachycardia syndrome (POTS), new intolerance in Vomiters was characterized by comparatively isolated upright hypocapnia and cerebral vasoconstriction. As a group, Vomiters also had evidence for increased postflight fluctuations in efferent vagal-cardiac nerve traffic occurring independently of any superimposed change in respiration. Results suggest that syndromes of orthostatic intolerance resembling those occurring after space flight can occur after a brief (i.e., 2-hr) parabolic flight.

Schlegel, Todd T.↗

Ethnic Differences in Physical Fitness, Blood Pressure and Blood Chemistry in Women (AGES 20-63)

This study examined the role of ethnicity on the aerobic fitness, blood pressure, and selected blood chemistry values of women. One hundred twenty-four females (mean age 41.37 +/- 9.0) were medically Examined at the NASA/Johnson Space Center occupational health clinic. Ethnic groups consisted of 23 Black (B), 18 Hispanic (H) and 83 Non-minority (NM). Each woman had a maximum Bruce treadmill stress test (RER greater than or = 1.1) and a negative ECG. Indirect calorimetry, skinfolds, self-report physical activity (NASA activity scale), seated blood pressure, and blood chemistry panel determined VO2max, percent fat, level of physical activity, blood pressure and blood chemistry values. ANOVA revealed that the groups did not differ (p greater than 0.05) in age, VO2 max, weight, percent fat, level of physical activity, total cholesterol, or HDL-C. However, significant differences (p greater than 0.05) were noted in BMI, diastolic blood pressure, and blood chemistries. BMI was 3.17 higher in H than in NM; resting diastolic pressures were 5.69 and 8.05 mmHg. lower in NM and H than in B; triglycerides were 48.07 and 37.21 mg/dl higher in H than in B and NM; hemoglobin was .814 gm/dl higher in NM than B; fasting blood sugar was 15.41 mg/dl higher in H than NM; The results of this study showed that ethnic groups differed in blood pressure and blood chemistry values but not aerobic fitness or physical activity. There was an ethnic difference in BMI but not percent fat.

Ayers, G. W.↗

Physiologic and Functional Responses of MS Patients to Body Cooling Using Commercially Available Cooling Garments

Personal cooling systems are widely used in industrial and aerospace environments to alleviate thermal stress. Increasingly they are also used by heat sensitive multiple sclerosis (HSMS) patients to relieve symptoms and improve quality of life. There are a variety of cooling systems commercially available to the MS community. However, little information is available regarding the comparative physiological changes produced by routine operation of these various systems. The objective of this study was to document and compare the patient response to two passive cooling vests and one active cooling garment. The Life Enhancement Technology, Inc. (LET) lightweight active cooling vest with cap, the MicroClimate Systems (MCS) Change of Phase garment, and the Steele Vest were each used to cool 13 male and 13 female MS subjects (31 to 67 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 C), were tested with one of the cooling garments. Oral, fight and left ear temperatures were logged manually every 5 min. An-n, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. Each subject was given a series of subjective and objective evaluation tests before and after cooling. The LET and Steele vests test groups had similar, significant (P less than 0.01) cooling effects on oral and ear canal temperature, which decreased approximately 0.4 C, and 0.3 C, respectively. Core temperature increased (N.S.) with all three vests during cooling. The LET vest produced the coldest (P less than 0.01) skin temperature. Overall, the LET vest provided the most improvement on subjective and objective performance measures. These results show that the garment configurations tested do not elicit a similar thermal response in all MS patients. Cooling with the LET active garment configuration resulted in the lowest body temperatures for the MS subjects; cooling with the MCS vest was least effective. For functional responses, the LET test group performed better than the other two vests.

Ku, Yu-Tsuan E.↗

A Dynamical Model for The Jupiter Thermocline

A new conceptual model for the observed banded wind structure of the giant outer planets is proposed, assuming a smoothly distributed potential vorticity (PV) atop a layer of deeply seated, latitudinally variable stratification. With a vanishing horizontal entropy contrast presumably enforced at the bottom of the flow layer by the underlying convection, the thermal-wind balance of observed cloud-top motions implies a mapping of constant potential temperature surfaces, nearly vertical at upper tropospheric levels, down to a deeper, flatter, but variably sloped 'thermocline.' For a generally colder-poleward distribution of isentropes consistent with the strong equatorial jets of both Jupiter and Saturn, this kind of mapping would also imply a poleward decreasing static stability. The proposed temperature-stability distribution is just the reverse of the Earth's troposphere, where the strongest latitudinal potential temperature gradients are at the bottom instead of the top, with static stability generally increasing toward the pole. The warmer-stabler correlation for Jupiter would be consistent, however, with a nearly monotonic distribution of PV from low to high latitudes, over planetary scales for which the planetary vorticity dominates the relative vorticity of the jets. In this way efficient PV mixing for the isentropically bounded thermocline can account for the dynamical maintenance of the cyclonic flanks of the equatorial jet. Over latitudinal intervals comparable to the internal deformation scale, however, the gradient of the absolute vorticity is dominated by the flow curvature, with the local latitudinal gradient of the static stability proportional to the local potential temperature gradient and therefore the local variation in geostrophic velocity. The resulting correlation of velocities and vorticity gradients implies an alternation of the flow over the internal deformation radius set by the vertical entropy contrast.

Allison, Michael↗

ASCAN Training: Egress and Parasail Training

Footage shows astronaut candidates during emergency egress and parasail training, performing such activities as practicing seat ejection procedures, power line landing, and parachute landing and release.

Source record↗

Coronal Heating and the Magnetic Flux Content of the Network

Previously, from analysis of SOHO coronal images in combination with Kitt Peak magnetograms, we found that the quiet corona is the sum of two components: the large-scale corona and the coronal network. The large-scale corona consists of all coronal-temperature (T approximately 10(exp 6) K) structures larger than supergranules (greater than approximately 30,000 kilometers). The coronal network (1) consists of all coronal-temperature structures smaller than supergranules, (2) is rooted in and loosely traces the photospheric magnetic network, (3) has its brightest features seated on polarity dividing lines (neutral lines) in the network magnetic flux, and (4) produces only about 5% of the total coronal emission in quiet regions. The heating of the coronal network is apparently magnetic in origin. Here, from analysis of EIT coronal images of quiet regions in combination with magnetograms of the same quiet regions from SOHO/MDI and from Kitt Peak, we examine the other 95% of the quiet corona and its relation to the underlying magnetic network. We find: (1) Dividing the large-scale corona into its bright and dim halves divides the area into bright "continents" and dark "oceans" having spans of 2-4 supergranules. (2) These patterns are also present in the photospheric magnetograms: the network is stronger under the bright half and weaker under the dim half. (3) The radiation from the large-scale corona increases roughly as the cube root of the magnetic flux content of the underlying magnetic network. In contrast, the coronal radiation from an active region increases roughly linearly with the magnetic flux content of the active region. We assume, as is widely held, that nearly all of the large-scale corona is magnetically rooted in the network. Our results suggest that either the coronal heating in quiet regions has a large non-magnetic component, or, if the heating is predominantly produced via the magnetic field, the mechanism is significantly different than in active regions.

Falconer, D. A.↗

Structural and Acoustic Numerical Modeling of a Curved Composite Honeycomb Panel

The finite and boundary element modeling of the curved section of a composite honeycomb aircraft fuselage sidewall was validated for both structural response and acoustic radiation. The curved panel was modeled in the pre-processor MSC/PATRAN. Geometry models of the curved panel were constructed based on the physical dimensions of the test article. Material properties were obtained from the panel manufacturer. Finite element models were developed to predict the modal parameters for free and supported panel boundary conditions up to a frequency of 600 Hz. Free boundary conditions were simulated by providing soft foam support under the four comers of the panel or by suspending the panel from elastic bands. Supported boundary conditions were obtained by clamping the panel between plastic tubing seated in grooves along the perimeter of a stiff and heavy frame. The frame was installed in the transmission loss window of the Structural Acoustic Loads and Transmission (SALT) facility at NASA Langley Research Center. The structural response of the curved panel due to point force excitation was predicted using MSC/NASTRAN and the radiated sound was computed with COMET/Acoustics. The predictions were compared with the results from experimental modal surveys and forced response tests on the fuselage panel. The finite element models were refined and updated to provide optimum comparison with the measured modal data. Excellent agreement was obtained between the numerical and experimental modal data for the free as well as for the supported boundary conditions. Frequency response functions (FRF) were computed relating the input force excitation at one panel location to the surface acceleration response at five panel locations. Frequency response functions were measured at the same locations on the test specimen and were compared with the calculated FRF values. Good agreement was obtained for the real and imaginary parts of the transfer functions when modal participation was allowed up to 3000 Hz. The validated finite element model was used to predict the surface velocities due to the point force excitation. Good agreement was obtained between the spatial characteristics of the predicted and measured surface velocities. The measured velocity data were input into the acoustic boundary element code to compute the sound radiated by the panel. The predicted sound pressure levels in the far-field of the panel agreed well with the sound pressure levels measured at the same location.

Grosveld, Ferdinand W.↗

Further Investigations of Control Surface Seals for the X-38 Re-Entry Vehicle

NASA is currently developing the X-38 vehicle that will be used to demonstrate the technologies required for a potential crew return vehicle (CRV) for the International Space Station. This vehicle would serve both as an ambulance for medical emergencies and as an evacuation vehicle for the Space Station. Control surfaces on the X-38 (body flaps and rudder/fin assemblies) require high temperature seals to limit hot gas ingestion and transfer of heat to underlying low-temperature structures to prevent over-temperature of these structures and possible loss of the vehicle. NASAs Johnson Space Center (JSC) and Glenn Research Center (GRC) are working together to develop and evaluate seals for these control surfaces. This paper presents results for compression. flow, scrub, and arc jet tests conducted on the baseline X-38 rudder/fin seal design. Room temperature seal compression tests were performed at low compression levels to determine load versus linear compression, preload. contact area, stiffness. and resiliency characteristics under low load conditions. For all compression levels that were tested, unit loads and contact pressures for the seals were below the 5 lb/in. and 10 psi limits required to limit the loads on the adjoining Shuttle thermal tiles that the seals will contact. Flow rates through an unloaded (i.e. 0% compression) double arrangement were twice those of a double seal compressed to the 20% design compression level. The seals survived an ambient temperature 1000 cycle scrub test over relatively rough Shuttle tile surfaces. The seals were able to disengage and re-engage the edges of the rub surface tiles while being scrubbed over them. Arc jet tests were performed to experimentally determine anticipated seal temperatures for representative flow boundary conditions (pressures and temperatures) under simulated vehicle re-entry conditions. Installation of a single seat in the gap of the test fixture caused a large temperature drop (1710 F) across the seal location as compared to an open gap condition (140 F) confirming the need for seals in the rudder/fin gap location. The seal acted as an effective thermal barrier limiting heat convection through the seal gap and minimizing temperature increases downstream of the seal during maximum heating conditions.

Dunlap, Patrick H., Jr.↗

The Exercise and Environmental Physiology of Extravehicular Activity

Over the history of human expansion into space, extravehicular activity (EVA) has become indispensable for both daily living in weightlessness and for further space exploration. The physiological factors involved in the performance of extensive EVA, necessary for construction and maintenance of the International Space Station and during future human interplanetary missions, require further examination. An understanding of the physiological aspects of exercise and thermoregulation in the EVA environment will help to insure the health, safety, and efficiency of working astronauts. To that end, this review will focus on the interaction of the exercise and environmental aspects of EVA, as well as exercise during spaceflight and ground-based simulations such as bed-rest deconditioning. It will examine inflight exercise thermoregulation, and exercise, muscular strength, supine vs. seated exercise, exercise thermoregulation, and exercise in a hypobaric environment. Due to the paucity of data from controlled human research in this area, it is clear that more scientific studies are needed to insure safe and efficient extravehicular activity.

Cowell, S. A.↗

Coronal Heating and the Magnetic Flux Content of the Network

Previously, from analysis of SOHO/EIT coronal images in combination with Kitt Peak magnetograms (Falconer et al 1998, ApJ, 501, 386-396), we found that the quiet corona is the sum of two components: the e-scale corona and the coronal network. The large-scale corona consists of all coronal-temperature (T approx. 10(exp 6) K) structures larger than supergranules (>approx.30,000 km). The coronal network (1) consists of all coronal-temperature structures smaller than supergranules, (2) is rooted in and loosely traces the photospheric magnetic network, (3) has its brightest features seated on polarity dividing fines (neutral lines) in the network magnetic flux, and (4) produces only about 5% of the total coronal emission in quiet regions. The heating of the coronal network is apparently magnetic in origin. Here, from analysis of EIT coronal images of quiet regions in combination with magnetograms of the same quiet regions from SOHO/MDI and from Kitt Peak, we examine the other 95% of the quiet corona and its relation to the underlying magnetic network. We find: (1) Dividing the large-scale corona into its bright and dim halves divides the area into bright "continents" and dark "oceans" having spans of 2-4 supergranules. (2) These patterns are also present in the photospheric magnetograms: the network is stronger under the bright half and weaker under the dim half. (3) The radiation from the large-scale corona increases roughly as the cube root of the magnetic flux content of the underlying magnetic network. In contrast, Fisher et A (1998, ApJ, 508, 985-998) found that the coronal radiation from an active region increases roughly linearly with the magnetic flux content of the active region. We assume, as is widely held, that nearly all of the large-scale corona is magnetically rooted in the network. Our results, together with the result of Fisher et al (1999), suggest that either the coronal heating in quiet regions has a large non-magnetic component, or, if the heating is predominantly produced via the magnetic field, the mechanism is significantly different than in active regions. This work is funded by NASA's Office of Space Science through the Solar Physics Supporting Research and Technology Program and the Sun-Earth Connection Guest Investigator Program.

Falconer, D. A.↗

Physiologic Responses Produced by Active and Passive Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to document and compare the subjects' response to three cooling vests in their recommended configurations. The Life Enhancement Tech (LET) lightweight active cooling vest with cap, the MicroClimate Systems Change of Phase garment (MCS), and the Steele Vest were each used to cool the chest regions of 12 male and 8 female Healthy subjects (21 to 69 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approx. 22 C), were tested for 60 min. with one of the cooling garments. The LET active garment had an initial coolant fluid inlet temperature of 60 F, and was ramped down to 50 F. Oral, right and left ear canal temperatures were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. For men, all three vests had similar, significant cooling effects. Decreases in the average rectal temperature, oral temperature, and ear canal temperatures were approximately 0.2 C, 0.2 C and 0.1 C, respectively. In contrast to the men, the female subjects wearing the MCS and Steel vests had similar cooling responses in which the core temperature remained elevated and oral and ear canal temperatures did not drop. The LET active garment cooled most of the female subjects in this study; rectal, oral and ear temperature decreased about 0.2 C, 0.3 C and 0.3 C, respectively. These results show that the garment configurations tested do not elicit a similar thermal response in all subjects. A gender difference is evident. The LET active garment configuration was most effective in decreasing temperatures of the female subjects; the MCS vest was least effective. For male subjects, the three vests appear to be more nearly equivalent. The active garment system under study included a cooling cap, which may account for some of the difference in response.

Ku, Yu-Tsuan E.↗

Hemodynamic Responses to Head and Neck Cooling

Personal thermoregulatory systems which provide head and neck cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objective of this study was to measure the scalp temperature and circulatory responses during use of one commercially available thermal control system. The Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used in this study. Two EEG electrodes and one skin temperature transducer were placed on the anterior midline of the scalp to measure the scalp blood and temperature. Blood flow was measured using a bipolar impedance rheograph. Ten subjects, seated in an upright position at normal room temperature, were tested at high, medium, moderate, moderate-low and low coolant temperatures. Scalp blood flow was recorded continuously using a computer data acquisition system with a sampling frequency of 200 Hz. Scalp temperature and cooling helmet Inlet temperature was logged periodically during the test period. This study quantifies the effect of head cooling upon scalp temperature and blood flow. These data may also be used to select operational specifications of the head cooling system for biomedical applications such as the treatment of migraine headaches, scalp cooling during chemotherapy, and cooling of multiple sclerosis patients.

Ku, Yu-Tsuan E.↗

STS-109 Flight Day 1 Highlights

While in orbit around Earth, the crew of STS-109 aboard the Columbia Orbiter will service the Hubble Space Telescope (HST) in five extravehicular activities (EVA). In this video, prelaunch activities are shown including the positioning of the astronauts in their seats prior to liftoff. Liftoff is also shown, as is the escape flight. A comment is also made concerning the announcement shortly after liftoff that there was restricted flow in one of two freon loops in the Orbiter's radiator.

Source record↗

Nonlinear Propagating Features in the Stratosphere of Jupiter Generated by the Impact of SL-9

Among the more intriguing features observed by HST after the impacts of the fragments of Shoemaker-Levy 9 were rings, encircling several of the impact sites, that expanded radially at constant velocities of order 450-500 m/s. One credible suggestion has been that the rings are stratospheric manifestations of linear gravity waves seated in the troposphere (Ingersoll and Kanamori, 1995). In this scenario the waves are made visible by a condensible material of unknown composition. Based on simulations of the comet impact by Zahnle and Mac Low (1995), we suggest an alternative hypothesis, namely that the rings are nonlinear stratospheric gravity waves which break and entrain impact debris material in the breaking wave front. The computations produce just such a feature, with the nonlinear breaking wave front in the stratosphere propagating radially away from the impact site with the correct speed. The computed ring of material is located in an altitude region where the static stability profile has a local maximum and therefore forms a waveguide. Because entrained impact debris forms the ring feature in the model, a condensate of some unknown composition is not required in order to view the wave front. However, there is one severe problem with the computed nonlinear wave: in contrast to a linear wave, it slows down. The computed feature stops within 1000 seconds, while the observed feature lasted at least 10,000 seconds. Since the nonlinear breaking wave front is a natural product of our impact simulations, we are now investigating the conditions that will enable the breaking wave front to propagate further, in accord with the observations. The results of these computations will be presented.

Young, R. E.↗