Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Murchison widefield array observations of anomalous variability: a serendipitous night-time detection of interplanetary scintillation

We present observations of high-amplitude rapid (2 s) variability toward two bright, compact extragalactic radio sources out of several hundred of the brightest radio sources in one of the 30{sup ∘}×30{sup ∘} Murchison Widefield Array (MWA) Epoch of Reionization fields using the MWA at 155 MHz. After rejecting intrinsic, instrumental, and ionospheric origins we consider the most likely explanation for this variability to be interplanetary scintillation (IPS), likely the result of a large coronal mass ejection propagating from the Sun. This is confirmed by roughly contemporaneous observations with the Ooty Radio Telescope. We see evidence for structure on spatial scales ranging from <1000 to >10{sup 6} km. The serendipitous night-time nature of these detections illustrates the new regime that the MWA has opened for IPS studies with sensitive night-time, wide-field, low-frequency observations. This regime complements traditional dedicated strategies for observing IPS and can be utilized in real-time to facilitate dedicated follow-up observations. At the same time, it allows large-scale surveys for compact (arcsec) structures in low-frequency radio sources despite the 2{sup ′} resolution of the array.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

In this work, liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by γ interactions from 228 Th (2615 keV), 226 Ra (1764 keV), and 60 Co (1332 keV and 1173 keV) calibration sources, over a range of electric fields. The W value that defines the recombination-independent energy scale is measured to be 11.5±0.5 (syst.) ±0.1 (stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV scale, which deviate from extrapolations of lower-energy data. Additionally, a semiempirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double β -decay detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calibrating the scintillation and ionization responses of xenon recoils for high-energy dark matter searches

We report liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up to 426 keV. The experiment uses 14.1 MeV neutrons to scatter off xenon in a compact liquid xenon time projection chamber and produce quasimonoenergetic xenon recoils between 39 and 426 keV. We report the xenon recoil responses and their electric field dependence for recoil energies up to 306 keV; due to the low event statistics and the relatively mild field dependence, the yield values at higher energies are reported as the average of xenon responses for electric fields between 0.2 and 2.0 kV/cm. This result will enable xenon-based dark matter experiments to significantly increase their high-energy dark matter sensitivities by including energy regions that were previously inaccessible due to lack of calibrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of {nu}{sub e}-electron scattering cross section with a CsI(Tl) scintillating crystal array at the Kuo-Sheng nuclear power reactor

The {nu}{sub e}-e{sup -} elastic scattering cross section was measured with a CsI(Tl) scintillating crystal array having a total mass of 187 kg. The detector was exposed to an average reactor {nu}{sub e} flux of 6.4x10{sup 12} cm{sup -2} s{sup -1} at the Kuo-Sheng Nuclear Power Station. The experimental design, conceptual merits, detector hardware, data analysis, and background understanding of the experiment are presented. Using 29882/7369 kg-days of Reactor ON/OFF data, the standard model (SM) electroweak interaction was probed at the squared 4-momentum transfer range of Q{sup 2{approx}}3x10{sup -6} GeV{sup 2}. The ratio of experimental to SM cross sections of {xi}=[1.08{+-}0.21(stat){+-}0.16(sys)] was measured. Constraints on the electroweak parameters (g{sub V},g{sub A}) were placed, corresponding to a weak mixing angle measurement of sin{sup 2{theta}}{sub W}=0.251{+-}0.031(stat){+-}0.024(sys). Destructive interference in the SM {nu}{sub e}-e process was verified. Bounds on anomalous neutrino electromagnetic properties were placed: neutrino magnetic moment at {mu}{sub {nu}{sub e}}<2.2x10{sup -10} {mu}{sub B} and the neutrino charge radius at -2.1x10{sup -32} cm{sup 2}<<r{sub {nu}}{sub e}{sup 2}><3.3x10{sup -32} cm{sup 2}, both at 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulse Shape Discrimination study with Gd loaded liquid scintillator for reactor neutrino monitoring

Recently, technique of Gadolinium loaded liquid scintillator (Gd-LS) for reactor neutrino oscillation experiments has attracted attention as a monitor of reactor operation and 'nuclear Gain (GA)' for IAEA safeguards. For the practical use, R and D of the 1 ton class compact detector, which is measurable above ground, is necessary. Especially, it is important to reduce much amount of fast neutron background induced by cosmic muons with data analysis for the measurement above ground. We developed a prototype of the Gd-LS detector with 200 L of the target volume, which has Pulse Shape Discrimination (PSD) ability for the fast neutron reduction with data analysis. Usually, it is well known that it is difficult to keep high fast neutron reduction power of PSD with the large volume size such as the neutrino reactor monitor. We evaluated the PSD ability of our prototype with real fast neutrons induced by the muons in our laboratory above ground, and we could confirm to keep the high fast neutron reduction power with even our large detector size. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal Growth, Optical and Scintillation Properties of Eu 2+ -doped TlSr 2 Br 5

Crystals of undoped and Eu 2+ -doped TlSr 2 Br 5 of up to 16 mm in diameter and 50 mm in length were grown by the Vertical Bridgman technique. TlSr 2 Br 5 has the monoclinic crystal structure with space group P21/c. Its density and Z eff are 5.03 g/cm 3 and 58.6, respectively. Radioluminescence spectra of undoped and Eu 2+ -doped TlSr 2 Br 5 feature a broad emission band peaking at about 440 nm for undoped and 520 nm for Eu 2+ -doped crystals. The light yield of undoped TlSr 2 Br 5 is 42,000 ph/MeV, which increases to 55,000 ph/MeV for Eu 2+ -doped crystals. The energy resolution at 662 keV ( 137 Cs) is about 5 – 6% (FWHM). As a result, the scintillation decay of undoped and Eu 2+ -doped TlSr 2 Br 5 is of the order of 100s of nanoseconds.

Bridgman technique↗

Conceptual Design of a Scintillator-Based Fast-Ion Loss Detector for the Wendelstein 7-X Stellarator

Here, a conceptual design of a scintillator-based fast-ion loss detector (FILD) has been developed for the Wendelstein 7-X stellarator (W7-X). Simulations using the Monte Carlo codes ASCOT5 and BEAMS3D have been performed to calculate the expected flux of neutral beam injection (NBI)-generated fast hydrogen ions onto the conceptual detector probe head. These fast-ion loss fluxes have been calculated for several magnetic field configurations as well as probe insertion positions. At the maximum insertion position, both co-and counter-going losses with high incident pitch angles are observed; however, at retracted positions, only co-going fast ions reach the probe head. The FILDSIM code has been used to optimize the geometry of the detector entrance and collimating elements to achieve a wide velocity space coverage as well as a high velocity–space resolution. A synthetic FILD signal is calculated for the expected loss distribution via forward modeling using the instrument response function. The synthetic signal is found to largely retain the velocity space features of the loss distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scintillation Properties of a Cs2LiLa(Br6)90%(Cl6)10%:Ce (CLLBC) Crystal

In investigations of Ce3+-doped Cs2LiLa(Br6)90%(Cl6)10% (CLLBC) elpasolite crystals, the crystals show an excellent neutron and gamma (n/g) radiation response. The results of our studies on the scintillation properties of CLLBC viz. radioluminescence, energy resolution, light yield, decay times, and nonproportionality are discussed. The CLLBC detector can provide energy resolution as good as 4.1% at 662 keV (FWHM), which is better than that of NaI:Tl. Because the crystal contains 6Li, CLLBC can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 MeV gamma equivalent energy. This high-energy signature for the thermal neutron peak means that very effective pulse height discrimination is possible. Unfortunately, because the core-to-valence luminescence observed in other elpasolites that can be exploited for effective pulse shape discrimination (PSD) is not observed in the CLLBC, other strategies for obtaining the PSD of CLLBC are needed. The n/g discrimination capability of CLLBC detectors may be optimized by tuning the cerium doping content for maximum effect on n/g pulse shape differences. The value of adding a chlorine component to the nominal CLLB crystal is discussed. Because the crystal contains chlorine, its sensitivity to fast neutrons is better than that of Cs2LiLaBr6 (CLLB). Further, an array of three of these CLLBC detectors may be able to perform directional detection in both the neutron and gamma channels simultaneously.

36 MATERIALS SCIENCE↗

Scintillation reduction for combined Gaussian-vortex beam propagating through turbulent atmosphere

We numerically examine the spatial evolution of the structure of coherent and partially coherent laser beams (PCBs), including the optical vortices, propagating in turbulent atmospheres, The influence of beam fragmentation and wandering relative to the axis of propagation (z-axis) on the value of the scintillation index (SI) of the signal at the detector is analyzed. A method for significantly reducing the SI, by averaging the signal at the detector over a set of PCBs, is described, This novel method is to generate the PCBs by combining two laser beams - Gaussian and vortex beams, with different frequencies (the difference between these two frequencies being significantly smaller than the frequencies themselves). In this case, the SI is effectively suppressed without any high-frequency modulators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SSPM Scintillator Readout for Gamma Radiation Detection

Silicon-based photodetectors offer several benefits relative to photomultiplier tube–based scintillator systems. Solid-state photomultipliers (SSPM) can realize the gain of a photomultiplier tube (PMT) with the quantum efficiency of silicon. The advantages of the solid-state approach must be balanced with adverse trade-offs, for example from increased dark current, to optimize radiation detection sensitivity. We are designing a custom SSPM that will be optimized for green emission of thallium-doped cesium iodide (CsI(Tl)). A typical field gamma radiation detector incorporates thallium doped sodium iodide (NaI(Tl)) and a radiation converter with a PMT. A PMT’s sensitivity peaks in the blue wavelengths and is well matched to NaI(Tl). This paper presents results of photomultiplier sensitivity relative to conventional SSPMs and discusses model design improvements. Prototype fabrications are in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector

Purpose: This work presents the experimental extraction of the overall perturbation factor P{sub Q} in megavoltage electron beams for NACP-02 and Roos parallel-plate ionization chambers using a plastic scintillation detector (PSD). Methods: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6, 12, and 18 MeV clinical electron beams. The authors also measured depth-dose curves using the NACP-02 and PTW Roos chambers. Results: The authors found that the perturbation factors for the NACP-02 and Roos chambers increased substantially with depth, especially for low-energy electron beams. The experimental results were in good agreement with the results of Monte Carlo simulations reported by other investigators. The authors also found that using an effective point of measurement (EPOM) placed inside the air cavity reduced the variation of perturbation factors with depth and that the optimal EPOM appears to be energy dependent. Conclusions: A PSD can be used to experimentally extract perturbation factors for ionization chambers. The dosimetry protocol recommendations indicating that the point of measurement be placed on the inside face of the front window appear to be incorrect for parallel-plate chambers and result in errors in the R{sub 50} of approximately 0.4 mm at 6 MeV, 1.0 mm at 12 MeV, and 1.2 mm at 18 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations

Purpose: To investigate the response of plastic scintillation detectors (PSDs) in a 6 MV photon beam of various field sizes using Monte Carlo simulations. Methods: Three PSDs were simulated: A BC-400 and a BCF-12, each attached to a plastic-core optical fiber, and a BC-400 attached to an air-core optical fiber. PSD response was calculated as the detector dose per unit water dose for field sizes ranging from 10x10 down to 0.5x0.5 cm{sup 2} for both perpendicular and parallel orientations of the detectors to an incident beam. Similar calculations were performed for a CC01 compact chamber. The off-axis dose profiles were calculated in the 0.5x0.5 cm{sup 2} photon beam and were compared to the dose profile calculated for the CC01 chamber and that calculated in water without any detector. The angular dependence of the PSDs' responses in a small photon beam was studied. Results: In the perpendicular orientation, the response of the BCF-12 PSD varied by only 0.5% as the field size decreased from 10x10 to 0.5x0.5 cm{sup 2}, while the response of BC-400 PSD attached to a plastic-core fiber varied by more than 3% at the smallest field size because of its longer sensitive region. In the parallel orientation, the response of both PSDs attached to a plastic-core fiber varied by less than 0.4% for the same range of field sizes. For the PSD attached to an air-core fiber, the response varied, at most, by 2% for both orientations. Conclusions: The responses of all the PSDs investigated in this work can have a variation of only 1%-2% irrespective of field size and orientation of the detector if the length of the sensitive region is not more than 2 mm long and the optical fiber stems are prevented from pointing directly to the incident source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of depth-dependent perturbation factors for silicon diodes using a plastic scintillation detector

Purpose: This work presents the experimental extraction of the perturbation factor in megavoltage electron beams for three models of silicon diodes (IBA Dosimetry, EFD and SFD, and the PTW 60012 unshielded) using a plastic scintillation detector (PSD). Methods: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6-, 12-, and 18-MeV clinical electron beams. They also measured depth-dose curves using the IBA Dosimetry, EFD and SFD, and the PTW 60012 unshielded diodes. The authors used the depth-dose curves measured with the PSD as a perturbation-free reference to extract the perturbation factors of the diodes. Results: The authors found that the perturbation factors for the diodes increased substantially with depth, especially for low-energy electron beams. The experimental results show the same trend as published Monte Carlo simulation results for the EFD diode; however, the perturbations measured experimentally were greater. They found that using an effective point of measurement (EPOM) placed slightly away from the source reduced the variation of perturbation factors with depth and that the optimal EPOM appears to be energy dependent. Conclusions: The manufacturer recommended EPOM appears to be incorrect at low electron energy (6 MeV). In addition, the perturbation factors for diodes may be greater than predicted by Monte Carlo simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: The case of the CyberKnife

Purpose: Small-field dosimetry is challenging, and the main limitations of most dosimeters are insufficient spatial resolution, water nonequivalence, and energy dependence. The purpose of this study was to compare plastic scintillation detectors (PSDs) to several commercial stereotactic dosimeters by measuring total scatter factors and dose profiles on a CyberKnife system. Methods: Two PSDs were developed, having sensitive volumes of 0.196 and 0.785 mm{sup 3}, and compared with other detectors. The spectral discrimination method was applied to subtract Cerenkov light from the signal. Both PSDs were compared to four commercial stereotactic dosimeters by measuring total scatter factors, namely, an IBA dosimetry stereotactic field diode (SFD), a PTW 60008 silicon diode, a PTW 60012 silicon diode, and a microLion. The measured total scatter factors were further compared with those of two independent Monte Carlo studies. For the dose profiles, two commercial detectors were used for the comparison, i.e., a PTW 60012 silicon diode and Gafchromics EBT2. Total scatter factors for a CyberKnife system were measured in circular fields with diameters from 5 to 60 mm. Dose profiles were measured for the 5- and 60-mm cones. The measurements were performed in a water tank at a 1.5-cm depth and an 80-cm source-axis distance. Results: The total scatter factors measured using all the detectors agreed within 1% with the Monte Carlo values for cones of 20 mm or greater in diameter. For cones of 10-20 mm in diameter, the PTW 60008 silicon diode was the only dosimeter whose measurements did not agree within 1% with the Monte Carlo values. For smaller fields (<10 mm), each dosimeter type showed different behaviors. The silicon diodes over-responded because of their water nonequivalence; the microLion and 1.0-mm PSD under-responded because of a volume-averaging effect; and the 0.5-mm PSD was the only detector within the uncertainties of the Monte Carlo simulations for all the cones. The PSDs, the PTW 60012 silicon diode, and the Gafchromics EBT2 agreed within 2% and 0.2 mm (gamma evaluation) for the measured dose profiles except in the tail of the 60-mm cone. Conclusions: Silicon diodes can be used to accurately measure small-field dose profiles but not to measure total scatter factors, whereas PSDs can be used to accurately measure both. The authors' measurements show that the use of a 1.0-mm PSD resulted in a negligible volume-averaging effect (under-response of Almost-Equal-To 1%) down to a field size of 5 mm. Therefore, PSDs are strong candidates to become reference radiosurgery detectors for beam characterization and quality assurance measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical photon transport in powdered-phosphor scintillators. Part II. Calculation of single-scattering transport parameters

Purpose: Monte Carlo methods based on the Boltzmann transport equation (BTE) have previously been used to model light transport in powdered-phosphor scintillator screens. Physically motivated guesses or, alternatively, the complexities of Mie theory have been used by some authors to provide the necessary inputs of transport parameters. The purpose of Part II of this work is to: (i) validate predictions of modulation transform function (MTF) using the BTE and calculated values of transport parameters, against experimental data published for two Gd{sub 2}O{sub 2}S:Tb screens; (ii) investigate the impact of size-distribution and emission spectrum on Mie predictions of transport parameters; (iii) suggest simpler and novel geometrical optics-based models for these parameters and compare to the predictions of Mie theory. A computer code package called phsphr is made available that allows the MTF predictions for the screens modeled to be reproduced and novel screens to be simulated. Methods: The transport parameters of interest are the scattering efficiency (Q{sub sct}), absorption efficiency (Q{sub abs}), and the scatter anisotropy (g). Calculations of these parameters are made using the analytic method of Mie theory, for spherical grains of radii 0.1-5.0 {mu}m. The sensitivity of the transport parameters to emission wavelength is investigated using an emission spectrum representative of that of Gd{sub 2}O{sub 2}S:Tb. The impact of a grain-size distribution in the screen on the parameters is investigated using a Gaussian size-distribution ({sigma}= 1%, 5%, or 10% of mean radius). Two simple and novel alternative models to Mie theory are suggested: a geometrical optics and diffraction model (GODM) and an extension of this (GODM+). Comparisons to measured MTF are made for two commercial screens: Lanex Fast Back and Lanex Fast Front (Eastman Kodak Company, Inc.). Results: The Mie theory predictions of transport parameters were shown to be highly sensitive to both grain size and emission wavelength. For a phosphor screen structure with a distribution in grain sizes and a spectrum of emission, only the average trend of Mie theory is likely to be important. This average behavior is well predicted by the more sophisticated of the geometrical optics models (GODM+) and in approximate agreement for the simplest (GODM). The root-mean-square differences obtained between predicted MTF and experimental measurements, using all three models (GODM, GODM+, Mie), were within 0.03 for both Lanex screens in all cases. This is excellent agreement in view of the uncertainties in screen composition and optical properties. Conclusions: If Mie theory is used for calculating transport parameters for light scattering and absorption in powdered-phosphor screens, care should be taken to average out the fine-structure in the parameter predictions. However, for visible emission wavelengths ({lambda} < 1.0 {mu}m) and grain radii (a > 0.5 {mu}m), geometrical optics models for transport parameters are an alternative to Mie theory. These geometrical optics models are simpler and lead to no substantial loss in accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-298: Small Field Total Scatter Factors Using a Commercial Scintillator Detector: Calibration Parameters Are Not Independent of Field Size

Purpose: To evaluate the accuracy in total scatter factor (Sc,p) determination for small fields using commercial plastic scintillator detector (PSD). The manufacturer's spectral discrimination method to subtract Cerenkov light from the signal is discussed. Methods: Sc,p for field sizes ranging from 0.5 to 10 cm were measured using PSD Exradin (Standard Imaging) connected to two channel electrometer measuring the signals in two different spectral regions to subtract the Cerenkov signal from the PSD signal. A Pinpoint ionisation chamber 31006 (PTW) and a non-shielded semiconductor detector EFD (Scanditronix) were used for comparison. Measures were performed for a 6 MV X-ray beam. The Sc,p are measured at 10 cm depth in water for a SSD=100 cm and normalized to a 10'10 cm{sup 2} field size at the isocenter. All detectors were placed with their symmetry axis parallel to the beam axis.We followed the manufacturer's recommended calibration methodology to subtract the Cerenkov contribution to the signal as well as a modified method using smaller field sizes. The Sc,p calculated by using both calibration methodologies were compared. Results: Sc,p measured with the semiconductor and the PinPoint detectors agree, within 1.5%, for field sizes between 10'10 and 1'1 cm{sup 2}. Sc,p measured with the PSD using the manufacturer's calibration methodology were systematically 4% higher than those measured with the semiconductor detector for field sizes smaller than 5'5 cm{sup 2}. By using a modified calibration methodology for smalls fields and keeping the manufacturer calibration methodology for fields larger than 5'5cm{sup 2} field Sc,p matched semiconductor results within 2% field sizes larger than 1.5 cm. Conclusion: The calibration methodology proposed by the manufacturer is not appropriate for dose measurements in small fields. The calibration parameters are not independent of the incident radiation spectrum for this PSD. This work was partially financed by grant 2012 of Barcelona board of the AECC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗