Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Observation of a smoothly tunable Dirac point in Ge ( Bi x Sb 1 - x ) 2 Te 4

State-of-the-art topological devices require the use of topologically protected surface states to drive electronic transport. Here, we examine a tunable topological system, Ge(Bi x Sb 1-x ) 2 Te 4 , for a range of $\mathcal{x}$ values from 0 to 1, using a combination of Fourier transform scanning tunneling spectroscopy and angle-resolved photoemission spectroscopy. Our results show that the Dirac point shifts linearly with $\mathcal{x}$, crossing the Fermi energy near $\mathcal{x}$=0.7. This observation of a smoothly tunable, isolated Dirac point crossing through the topological transport regime and having strong linear dependence with substitution can be critical for future topological spintronics applications.

36 MATERIALS SCIENCE↗

SU-E-J-167: Dosimetric Consequences From Minimal Displacements in APBI with SAVI Applicators

Purpose: To determine the importance of providing proper solid immobilization in every fraction of treatment in APBI with brachytherapy. Methods: 125 patients treated with APBI brachytherapy with SAVI applicators at SFRO Boca Raton, from 2013–2015 were considered for this retrospective study. The CT scans of each patient, which were taken before each treatment, were imported in to the Oncentra treatment planning system. Then they were compared with the initial CT scan which was used for the initial plan. Deviation in displacements in reference to ribs and skin surface was measured and dosimetric evaluations respective to the initial image were performed. Results: Small deviations in displacements were observed from the SAVI applicator to the ribs and the skin surface. Dosimetric evaluations revealed, very small changes in the inter-fractionation position make significant differences in the maximum dose to critical organs. Additionally, the volume of the cavity also changed between fractions. As a Result, the maximum dose manifested variance between 10% and 32% in ribs and skin surface respectively. Conclusion: It appears that taking a CT scan before each treatment is necessary to minimize the risk of delivering undesired high doses to the critical organs. This study indicates, in 30% of the cases re-planning was necessary between treatments. We conclude that, treatment planning teams should evaluate the placement of the device by analyzing the CT images before each treatment and they must be prepared for re-planning if needed. This study also reveals the urgent need of improving the immobilization methods with APBI when treating with the SAVI applicator.

60 APPLIED LIFE SCIENCES↗

SU-F-J-54: Towards Real-Time Volumetric Imaging Using the Treatment Beam and KV Beam

Purpose: Existing real-time imaging uses dual (orthogonal) kV beam fluoroscopies and may result in significant amount of extra radiation to patients, especially for prolonged treatment cases. In addition, kV projections only provide 2D information, which is insufficient for in vivo dose reconstruction. We propose real-time volumetric imaging using prior knowledge of pre-treatment 4D images and real-time 2D transit data of treatment beam and kV beam. Methods: The pre-treatment multi-snapshot volumetric images are used to simulate 2D projections of both the treatment beam and kV beam, respectively, for each treatment field defined by the control point. During radiation delivery, the transit signals acquired by the electronic portal image device (EPID) are processed for every projection and compared with pre-calculation by cross-correlation for phase matching and thus 3D snapshot identification or real-time volumetric imaging. The data processing involves taking logarithmic ratios of EPID signals with respect to the air scan to reduce modeling uncertainties in head scatter fluence and EPID response. Simulated 2D projections are also used to pre-calculate confidence levels in phase matching. Treatment beam projections that have a low confidence level either in pre-calculation or real-time acquisition will trigger kV beams so that complementary information can be exploited. In case both the treatment beam and kV beam return low confidence in phase matching, a predicted phase based on linear regression will be generated. Results: Simulation studies indicated treatment beams provide sufficient confidence in phase matching for most cases. At times of low confidence from treatment beams, kV imaging provides sufficient confidence in phase matching due to its complementary configuration. Conclusion: The proposed real-time volumetric imaging utilizes the treatment beam and triggers kV beams for complementary information when the treatment beam along does not provide sufficient confidence for phase matching. This strategy minimizes the use of extra radiation to patients. This project is partially supported by a Varian MRA grant.

60 APPLIED LIFE SCIENCES↗

Cryogenic specimens for nanoscale characterization of solid–liquid interfaces

We report new cryogenic characterization techniques for exploring the nanoscale structure and chemistry of intact solid–liquid interfaces have recently been developed. These techniques provide high-resolution information about buried interfaces from large samples or devices that cannot be obtained by other means. These advancements were enabled by the development of instrumentation for cryogenic focused ion beam liftout, which allows intact solid–liquid interfaces to be extracted from large samples and thinned to electron-transparent thicknesses for characterization by cryogenic scanning transmission electron microscopy or atom probe tomography. Future implementation of these techniques will complement current strides in imaging of materials in fluid environments by in situ liquid-phase electron microscopy, providing a more complete understanding of the morphology, surface chemistry, and dynamic processes that occur at solid–liquid interfaces.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

He-Ion and Self-Atom Induced Damage and Surface-Morphology Changes of a Hot W Target

We report results of measurements on the evolution of the surface morphology of a hot tungsten surface due to impacting low-energy (80 12,000 eV) He ions and of simulations of damage caused by cumulative bombardment of 1 and 10 keV W self-atoms. The measurements were performed at the ORNL Multicharged Ion Research Facility (MIRF), while the simulations were done at the Kraken supercomputing facility of the University of Tennessee. At 1 keV, the simulations show strong defect-recombination effects that lead to a saturation of the total defect number after a few hundreds impacts, while sputtering leads to an imbalance of the vacancy and interstitial number. On the experimental side, surface morphology changes were investigated over a broad range of fluences for both virgin and pre-damaged W-targets. At the lowest accumulated fluences, small surface-grain features and near-surface He bubbles are observed. At the largest fluences, individual grain characteristics disappear in FIB/SEM scans, and the entire surface is covered by a multitude of near-surface bubbles with a broad range of sizes, and disordered whisker growth, while in top-down SEM imaging the surface is virtually indistinguishable from the nano-fuzz produced on linear plasma devices. These features are evident at progressively lower fluences as the He-ion energy is increased.

Meyer, Fred W↗

Investigation of abrupt degradation of drain current caused by under-gate crack in AlGaN/GaN high electron mobility transistors during high temperature operation stress

In this paper, we investigate the degradation mode and mechanism of AlGaN/GaN based high electron mobility transistors (HEMTs) during high temperature operation (HTO) stress. It demonstrates that there was abrupt degradation mode of drain current during HTO stress. The abrupt degradation is ascribed to the formation of crack under the gate which was the result of the brittle fracture of epilayer based on failure analysis. The origin of the mechanical damage under the gate is further investigated and discussed based on top-down scanning electron microscope, cross section transmission electron microscope and energy dispersive x-ray spectroscopy analysis, and stress simulation. Based on the coupled analysis of the failure physical feature and stress simulation considering the coefficient of thermal expansion (CTE) mismatch in different materials in gate metals/semiconductor system, the mechanical damage under the gate is related to mechanical stress induced by CTE mismatch in Au/Ti/Mo/GaN system and stress concentration caused by the localized structural damage at the drain side of the gate edge. These results indicate that mechanical stress induced by CTE mismatch of materials inside the device plays great important role on the reliability of AlGaN/GaN HEMTs during HTO stress.

36 MATERIALS SCIENCE↗

Atomic-Scale Manipulation and In Situ Characterization with Scanning Tunneling Microscopy

Scanning tunneling microscope (STM) has presented a revolutionary methodology to nanoscience and nanotechnology. It enables imaging of the topography of surfaces, mapping the distribution of electronic density of states, and manipulating individual atoms and molecules, all at atomic resolutions. In particular, atom manipulation capability has evolved from fabricating individual nanostructures toward the scalable production of the atomic-sized devices bottom-up. The combination of precision synthesis and in situ characterization has enabled direct visualization of many quantum phenomena and fast proof-of-principle testing of quantum device functions with immediate feedback to guide improved synthesis. Several representative examples are reviewed to demonstrate the recent development of atomic-scale manipulation, focusing on progress that addresses quantum properties by design in several technologically relevant materials systems. Integration of several atomically precisely controlled probes in a multiprobe STM system vastly extends the capability of in situ characterization to a new dimension where the charge and spin transport behaviors can be examined from mesoscopic to atomic length scale. The automation of atomic-scale manipulation and the integration with well-established lithographic processes further push this bottom-up approach to a new level that combines reproducible fabrication, extraordinary programmability, and the ability to produce large-scale arrays of quantum structures.

47 OTHER INSTRUMENTATION↗

Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the technical basis for the clinical integration of PET/MR hybrid imaging into RT treatment planning.

60 APPLIED LIFE SCIENCES↗

AlCl 3 -Dosed Si(100)-2 × 1: Adsorbates, Chlorinated Al Chains, and Incorporated Al

The adsorption of AlCl 3 on Si(100) and the effect of annealing the AlCl 3 -dosed substrate were studied to reveal key surface processes for the development of atomic-precision, acceptor-doping techniques. This investigation was performed via scanning tunneling microscopy (STM), X-ray photoelectron spectroscopy (XPS), and density functional theory (DFT) calculations. At room temperature, AlCl 3 readily adsorbed to the Si substrate dimers and dissociated to form a variety of species. Annealing the AlCl 3 -dosed substrate at temperatures below 450 °C produced unique chlorinated aluminum chains (CACs) elongated along the Si(100) dimer row direction. An atomic model for the chains is proposed with supporting DFT calculations. Al was incorporated into the Si substrate upon annealing at 450 °C and above, and Cl desorption was observed for temperatures beyond 450 °C. Al-incorporated samples were encapsulated in Si and characterized by secondary ion mass spectrometry (SIMS) depth profiling to quantify the Al atom concentration, which was found to be in excess of 10 20 cm –3 across a ~2.7 nm-thick δ-doped region. Here, the Al concentration achieved here and the processing parameters utilized promote AlCl 3 as a viable gaseous precursor for novel acceptor-doped Si materials and devices for quantum computing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic brightening and nanoscale imaging of spin-polarized helical edge modes in ZrTe 5

Efficient charge transport remains a fundamental challenge for nanoelectronic devices, as their performance is constrained by high dissipation and the impedance mismatch between high-frequency signal sources and nanoscale circuit interfaces. Although topologically protected helical edge modes offer a dissipationless and backscattering-resilient alternative, achieving nanoscale control over these modes requires direct visualization of their spatial electrodynamics, especially under high-frequency operation. Here, by utilizing cryogenic magneto-infrared scattering-type scanning near-field optical microscopy (cm-IR-sSNOM), we image spin-polarized helical edge channels in ZrTe 5 at the nanoscale, revealing magnetic-field-induced brightening as a high-frequency electrodynamic signature of robust topological edge modes. Operating at 1.8 K and under a magnetic field of up to 5 T, we observe the emergence of edge-state polarizability at infrared frequencies that is notably resilient to the magnetic gaps that typically quench d.c. and microwave edge transport. Our results reveal a topological ‘two-lane’ spatial reorganization in which an external magnetic field induces a spin-population imbalance between counterpropagating edge modes. Favoured helical branches are confined against physical boundaries to activate a net infrared near-field contrast. This electrodynamic response scales linearly with the number of atomic layers, which confirms that individual layers in ZrTe 5 preserve their discrete quantum spin Hall identities. These findings may be useful for developing topological spintronic devices, as the magnetic infrared tunability of helical edge channels provides a pathway for low-loss nanoscale interconnects and high-speed information processing.

36 MATERIALS SCIENCE↗

Mesoscale characterization of local property distributions in heterogeneous electrodes

We report the performance of electrochemical devices depends on the three-dimensional (3D) distributions of microstructural features in their electrodes. Several mature methods exist to characterize 3D microstructures over the microscale (tens of microns), which are useful in understanding homogeneous electrodes. However, methods that capture mesoscale (hundreds of microns) volumes at appropriate resolution (tens of nm) are lacking, though they are needed to understand more common, less ideal electrodes. Using serial sectioning with a Xe plasma focused ion beam combined with scanning electron microscopy (Xe PFIB-SEM), two commercial solid oxide fuel cell (SOFC) electrodes are reconstructed over volumes of 126 × 73 × 12.5 and 124 × 110 × 8 μm 3 with a resolution on the order of ≈ 50 3 nm 3 . The mesoscale distributions of microscale structural features are quantified and both microscale and mesoscale inhomogeneities are found. We analyze the origin of inhomogeneity over different length scales by comparing experimental and synthetic microstructures, generated with different particle size distributions, with such synthetic microstructures capturing well the high-frequency heterogeneity. Effective medium theory models indicate that significant mesoscale variations in local electrochemical activity are expected throughout such electrodes. Finally, these methods offer improved understanding of the performance of complex electrodes in energy conversion devices.

30 DIRECT ENERGY CONVERSION↗

The Atomic Drill Bit: Precision Controlled Atomic Fabrication of 2D Materials

The ability to deterministically fabricate nanoscale architectures with atomic precision is the central goal of nanotechnology, whereby highly localized changes in the atomic structure can be exploited to control device properties at their fundamental physical limit. Here, an automated, feedback-controlled atomic fabrication method is reported and the formation of 1D–2D heterostructures in MoS 2 is demonstrated through selective transformations along specific crystallographic orientations. The atomic-scale probe of an aberration-corrected scanning transmission electron microscope (STEM) is used, and the shape and symmetry of the scan pathway relative to the sample orientation are controlled. The focused and shaped electron beam is used to reliably create Mo 6 S 6 nanowire (MoS-NW) terminated metallic-semiconductor 1D–2D edge structures within a pristine MoS 2 monolayer with atomic precision. From these results, it is found that a triangular beam path aligned along the zig-zag sulfur terminated (ZZS) direction forms stable MoS-NW edge structures with the highest degree of fidelity without resulting in disordering of the surrounding MoS 2 monolayer. Density functional theory (DFT) calculations and ab initio molecular dynamic simulations (AIMD) are used to calculate the energetic barriers for the most stable atomic edge structures and atomic transformation pathways. These discoveries provide an automated method to improve understanding of atomic-scale transformations while opening a pathway toward more precise atomic-scale engineering of materials.

2D materials↗

Charge collection kinetics on ferroelectric polymer surface using charge gradient microscopy

Here, a charge gradient microscopy (CGM) probe was used to collect surface screening charges on poly(vinylidene fluoride-trifluoroethylene) [P(VDF-TrFE)] thin films. These charges are naturally formed on unscreened ferroelectric domains in ambient condition. The CGM data were used to map the local electric current originating from the collected surface charges on the poled ferroelectric domains in the P(VDF-TrFE) thin films. Both the direction and amount of the collected current were controlled by changing the polarity and area of the poled domains. The endurance of charge collection by rubbing the CGM tip on the polymer film was limited to 20 scan cycles, after which the current reduced to almost zero. This degradation was attributed to the increase of the chemical bonding strength between the external screening charges and the polarization charges. Once this degradation mechanism is mitigated, the CGM technique can be applied to efficient energy harvesting devices using polymer ferroelectrics.

36 MATERIALS SCIENCE↗

Interface reconstruction with emerging charge ordering in hexagonal manganite

Multiferroic materials, which simultaneously have multiple orderings, hold promise for use in the next generation of memory devices. We report a novel self-assembled MnO double layer forming at the interface between a multiferroic YMnO 3 film and a c-Al 2 O 3 substrate. The crystal structures and the valence states of this MnO double layer were studied by atomically resolved scanning transmission electron microscopy and spectroscopy, as well as density functional theory (DFT) calculations. A new type of charge ordering has been identified within this MnO layer, which also contributes to a polarization along the [001] direction. DFT calculations further establish the occurrence of multiple couplings between charge and lattice in this novel double layer, in addition to the polarization in nearby YMnO 3 single layer. The interface reconstruction reported here creates a new playground for emergent physics, such as giant ferroelectricity and strong magnetoelectric coupling, in manganite systems.

36 MATERIALS SCIENCE↗

Studying Corrosion Using Miniaturized Particle Attached Working Electrodes and the Nafion Membrane

We developed a new approach to attach particles onto a conductive layer as a working electrode (WE) in a microfluidic electrochemical cell with three electrodes. Nafion, an efficient proton transfer molecule, is used to form a thin protection layer to secure particle electrodes. Spin coating is used to develop a thin and even layer of Nafion membrane. The effects of Nafion (5 wt% 20 wt%) and spinning rates were evaluated using multiple sets of replicates. The electrochemical performance of various devices was demonstrated. Additionally, the electrochemical performance of the devices is used to select and optimize fabrication conditions. The results show that a higher spinning rate and a lower Nafion concentration (5 wt%) induce a better performance, using cerium oxide (CeO2) particles as a testing model. The WE surfaces were characterized using atomic force microscopy (AFM), scanning electron microscopy-focused ion beam (SEM-FIB), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and X-ray photoelectron spectroscopy (XPS). The comparison between the pristine and corroded WE surfaces shows that Nafion is redistributed after potential is applied. Our results verify that Nafion membrane offers a reliable means to secure particles onto electrodes. Furthermore, the electrochemical performance is reliable and reproducible. Thus, this approach provides a new way to study more complex and challenging particles, such as uranium oxide, in the future.

42 ENGINEERING↗

Synthesis of polyaniline/SnO{sub 2} nanocomposite and its improved electrochemical performance

Highlights: • Supercapacitors based on PANI/SnO{sub 2} nanocomposite were reported. • Supercapacitors using this material gave a specific capacitance of 501 F g{sup −1}. • Capacitance retention was 85.8% over 2000 charge–discharge cycles. - Abstract: SnO{sub 2} was prepared by the hydrothermal route. Aniline monomer was polymerized in the suspension of SnO{sub 2} to form inorganic–organic nanocomposite materials, in which SnO{sub 2} particles were embedded within polyaniline (PANI). Morphological and structural characterizations of the prepared samples were carried out using scanning electron microscope; transmission electron microscope; power X-ray diffraction and Fourier transform infrared spectroscopy. Their electrochemical properties were also investigated using cyclic voltammetry, galvanostatic charge–discharge and electrochemical impedance spectroscopy. The as-prepared nanocomposites had excellent properties in the capacitance, and its specific capacitance was up to 501 F g{sup −1} with a specific energy density of 66.8 W h kg{sup −1} at a power density of 960.6 W kg{sup −1}. The device fulfilled the requirement of long durability necessary for an energy storage system, since after 2000 galvanostatic charge–discharge cycles, retention of 85.8% in capacitance was observed. These results indicated that the PANI/SnO{sub 2} had a synergistic effect of the complementary properties of both components.

36 MATERIALS SCIENCE↗

Optical waveguiding properties into porous gallium nitride structures investigated by prism coupling technique

In order to modulate the refractive index and the birefringence of Gallium Nitride (GaN), we have developed a chemical etching method to perform porous structures. The aim of this research is to demonstrate that optical properties of GaN can be tuned by controlling the pores density. GaN films are prepared on sapphire by metal organic chemical vapor deposition and the microstructure is characterized by transmission electron microscopy, and scanning electron microscope analysis. Optical waveguide experiment is demonstrated here to determine the key properties as the ordinary (n{sub 0}) and extraordinary (n{sub e}) refractive indices of etched structures. We report here the dispersion of refractive index for porous GaN and compare it to the bulk material. We observe that the refractive index decreases when the porous density p is increased: results obtained at 0.975 μm have shown that the ordinary index n{sub 0} is 2.293 for a bulk layer and n{sub 0} is 2.285 for a pores density of 20%. This value corresponds to GaN layer with a pore size of 30 nm and inter-distance of 100 nm. The control of the refractive index into GaN is therefore fundamental for the design of active and passive optical devices.

36 MATERIALS SCIENCE↗