Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Edge magnetoplasmon dispersion and time-resolved plasmon transport in a quantum anomalous Hall insulator

A quantum anomalous Hall (QAH) insulator breaks reciprocity by combining magnetic polarization and spin-orbit coupling to generate a unidirectional transmission of signals in the absence of an external magnetic field. Such behavior makes QAH materials a good platform for the innovation of circulator technologies. However, it remains elusive as to how the wavelength of the chiral edge plasmon relates to its frequency and how the plasmon wave packet is excited in the time domain in a QAH insulator. Here, we investigate the edge magnetoplasmon (EMP) resonances in Cr-(Bi,Sb) 2 Te 3 by frequency and time domain measurements. From disk shaped samples with various dimensions, we obtain the dispersion relation of EMPs and extract the drift velocity of the chiral edge state. From the time-resolved transport measurements, we identify the velocity of the plasmon wave packet and observe a transition from the edge to bulk transport at an elevated temperature. We show that the frequency and time domain measurements are well modeled by loss from the microwave induced dissipative channels in the bulk area. Our results demonstrate that the EMP decay rate can be significantly reduced by applying a low microwave power and fabricating devices of larger diameter ≥ 100 µ m . In a R = 125 µ m sample, a nonreciprocity of 20 dB has been realized at 1.3 GHz, shining light on using QAH insulators to develop on-chip nonreciprocal devices. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new method for quantifying 64 Cu in nuclear debris samples

Quantifying 64 Cu in post-detonation nuclear debris samples can provide important diagnostic information regarding the structural materials used within a nuclear device. However, this task is challenging due to the weak gamma emissions associated with the decay of 64 Cu, its short half-life (12.701 h), and the presence of interfering fission product radioisotopes. Large quantities of debris sample are generally needed to accurately quantify 64 Cu, which can be problematic in sample-limited scenarios where other radiometric analyses are required. Herein, we present a new method for the separation of 64 Cu from solutions of mixed fission products and demonstrate the quantification of its activity through use of gas-flow proportional beta counting. Here, the new method was validated through a series of rigorous tests and was shown to improve the detection limit of 64 Cu by over two orders of magnitude, from 2.5 × 10 6 to 1.3 × 10 4 atoms/sample for 100 min measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Uranium Enrichment Safeguards

DIV of facility layout, material flows, and other information provided in the DIQ. Material accountancy through an annual PIV and a number of interim inventory verifications, including UF6 cylinder identification and counting, NDA of cylinders, and DA on a sample collection of UF6. Application of C/S technologies utilizing seals and tamper-indicating devices (TIDs) on cylinders, containers, storage rooms, and IAEA instrumentation to provide continuity of knowledge between inspection. Verification of the absence of undeclared material and operations, especially HEU production, through SNRIs, LFUA of cascade halls, and environmental swipe sampling

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nonreciprocal Supercurrents in a Field-Free Graphene Josephson Triode

Superconducting diodes are proposed non-reciprocal circuit elements that should exhibit nondissipative transport in one direction while being resistive in the opposite direction. Multiple examples of such devices have emerged in the past couple of years, however their efficiency is typically limited, and most of them require magnetic field to function. Here we present a device achieving efficiencies upwards of 90% while operating at zero field. Our samples consist of a network of three graphene Josephson junctions linked by a common superconducting island, to which we refer as a Josephson triode. The triode is tuned by applying a control current to one of the contacts, thereby breaking the time-reversal symmetry of the current flow. The triode’s utility is demonstrated by rectifying a small (tens of nA amplitude) applied square wave. Finally, we speculate that devices of this type could be realistically employed in the modern quantum circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Feedback on Forty-year Long Clean-up Operations of a Contaminated Soil for Environmental Purpose - 20026

One of the CEA facilities in France is the place of miscellaneous mapping and clean-up operations since the 1980's. The final purpose of the conducted work deals with the environmental remediation of the building. In France, the absence of a regulatory framework for the management of sites polluted by radioactive substances, especially as the lack of release thresholds, has led to develop different approaches of soil radiological characterization. The geostatistical approach is part of them. Preliminary investigations are an unavoidable step prior to clearance and remediation. First, historical analysis enables to define site perimeters to investigate as well as to precisely locate expected contaminated parts. For radioactive pollutants, the media (water, soil, air) and transfer routes participate in the definition of the investigation perimeter and thus also need to be identified through a geological study. At the same time, functional analysis leads to choose the best measurement means which could provide useful information when combined with visual inspection. An equipment well adapted to easy-to-measure radionuclides as gamma emitters, such as gamma probe or on-site gamma spectrometry, is usually selected as a non-destructive assay. Coupled with spatial positions, processed on-site radiological data can be mapped. Data processing consists in mapping and kriging before a geostatistical analysis in order to identify the zones of interest to be targeted. Selected zones are not only linked to high level count rates but also to low level ones so that a pollution-free reference is known in the area. This data processing also enables to categorize waste types according to their origin and contamination levels. An expected volume of different waste then follows as well as the waste characterization equipments. In-depth investigations, e.g. core drillings and samplings, naturally ensue to aim at remediation optimization through the assessment of environmental impact. After clean-up operations, non-destructive assays as well as destructive samplings enable to check the effective clearance. Following this methodology in the present remediation work, results of the first non-destructive assay campaign highlighted a long-lived transuranic radionuclides contamination in the concrete flagstone. Successive non-destructive assays were then performed in the defined zones of interest. Count rates measured with a surface probe were first mapped. The best localization of destructive assays, i.e. core drillings at a 1 meter depth, came from this surface mapping followed by a geostatistical analysis. The concrete flagstone was totally removed. Then, the depth of soil to remove under the flagstone was optimized from the results of radiological activities measured in core drillings samples. A new surface mapping was then drawn after this partial soil excavation. The sand and demolition rubble samples, homogeneously constituted from the flagstone fragments, were analyzed by gamma spectrometry. Meanwhile, waste drums and other containers were also measured by gamma spectrometry and passive neutron measurement devices. All these results have brought miscellaneous pieces of information. In this context, major issues appear in terms of physical constraints such as the premises tininess as well as of soil sampling techniques and in terms of measurement performances assessment and the representativeness of homogeneous samples. The choice of radiological soil and waste characterization devices is described in the light of enhanced performances by keeping in mind radiation protection requirements and a willing to always optimize waste categories (very low level waste) and volume. The improvement of the characterization methods appears through this forty-year long work while sharing the feedback of encountered difficulties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine learning coupled multi-scale modeling for redox flow batteries

The reaction distribution in macro or device-scale has been studied for redox flow batteries. The reaction distribution on electrode pore-scale structure however is not well understood, lacking especially on how the reaction distribution on the pore-scale may impact the overall performance of a flow battery. This study introduces for the first time a framework of a multi-scale model that provides understanding of the relationship between the pore-scale electrode structure reaction and the device-scale electrochemical reaction uniformity within the flow battery. A reduced order model is constructed based on 128 pore-scale simulations, which provide a quantitative relationship between the battery operation conditions (inlet velocity, current density, inlet concentration) and the surface reaction uniformity for the pore-scale sample. The multi-scale framework upscales this pore-scale surface reaction uniformity to device-scale combined uniformity. Based on the multi-scale model, a time-varying optimization of the inlet velocity is established, leading to significant reduction on pump power consumption with targeted surface reaction uniformity. The multi-scale model establishes the critical link between the micro-structure of a flow battery component and its performance at the macro-scale, therefore providing rationale for further operational or material optimization.

flow batteries, machine learning, multi-scale mode↗

Penetrator Coring Apparatus for Cometary Surfaces

Touch and go impact coring is an attractive technique for sampling cometary nuclei and asteroidal surface on account of the uncertain strength properties and low surface gravities of these objects. Initial coring experiments in low temperature (approx. 153K polycrystalline ice) and porous rock demonstrate that simultaneous with impact coring, measurements of both the penetration strength and constraints on the frictional properties of surface materials can be obtained upon core penetration and core sample extraction. The method of sampling an asteroid, to be deployed, on the now launched MUSES-C mission, employs a small gun device that fires into the asteroid and the resulted impact ejecta is collected for return to Earth. This technique is well suited for initial sampling in a very low gravity environment and deployment depends little on asteroid surface mechanical properties. Since both asteroids and comets are believed to have altered surface properties a simple sampling apparatus that preserves stratigraphic information, such as impact coring is an attractive alternate to impact ejecta collection.

Braun, David F.↗

Devices for SRF material characterization

The surface resistance Rs of superconducting materials can be obtained by measuring the quality factor of an elliptical cavity excited in a transverse magnetic mode (TM010). The value obtained has however to be taken as averaged over the whole surface. A more convenient way to obtain Rs, especially of materials which are not yet technologically ready for cavity production, is to measure small samples instead. These can be easily man ufactured at low cost, duplicated and placed in film deposition and surface analytical tools. A commonly used design for a device to measure Rs consists of a cylindrical cavity excited in a transverse electric (TE110) mode with the sample under test serving as one replaceable endplate. Such a cavity has two drawbacks. For reasonably small samples the resonant frequency will be larger than frequencies of interest concerning SRF application and it requires a reference sample of known Rs. In this article we review several devices which have been designed to overcome these limitations, reaching sub - nΩ resolution in some cases. Some of these devices also comprise a parameter space in frequency and temperature which is inaccessible to standard cavity tests, making them ideal tools to test theoretical surface resistance models.

43 PARTICLE ACCELERATORS↗

Spontaneous Valley Polarization of Itinerant Electrons

Memory or transistor devices based on an electron’s spin rather than its charge degree of freedom offer certain distinct advantages and comprise a cornerstone of spintronics. Recent years have witnessed the emergence of a new field, valleytronics, which seeks to exploit an electron’s valley index rather than its spin. An important component in this quest would be the ability to control the valley index in a convenient fashion. Here we show that the valley polarization can be switched from zero to 1 by a small reduction in density, simply tuned by a gate bias, in a two-dimensional electron system. This phenomenon, which is akin to Bloch spin ferromagnetism, arises fundamentally as a result of electron-electron interaction in an itinerant, dilute electron system. Essentially, the kinetic energy favors an equal distribution of electrons over the available valleys, whereas the interaction between electrons prefers single-valley occupancy below a critical density. The gate-bias-tuned transition we observe is accompanied by a sudden, twofold change in sample resistance, making the phenomenon of interest for potential valleytronic transistor device applications. Finally, our observation constitutes a quintessential demonstration of valleytronics in a very simple experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pressure-flow reducer for aerosol focusing devices

A pressure-flow reducer, and an aerosol focusing system incorporating such a pressure-flow reducer, for performing high-flow, atmosphere-pressure sampling while delivering a tightly focused particle beam in vacuum via an aerodynamic focusing lens stack. The pressure-flow reducer has an inlet nozzle for adjusting the sampling flow rate, a pressure-flow reduction region with a skimmer and pumping ports for reducing the pressure and flow to enable interfacing with low pressure, low flow aerosol focusing devices, and a relaxation chamber for slowing or stopping aerosol particles. In this manner, the pressure-flow reducer decouples pressure from flow, and enables aerosol sampling at atmospheric pressure and at rates greater than 1 liter per minute.

47 OTHER INSTRUMENTATION↗

Modeling and measurement of the performance of a branched conduit sampling system in a mass spectrometer leak detector

In the leak testing of a large engineering system, one may distinguish three stages, namely leakage measurement by an overall enclosure, leak location, and leakage measurement by a local enclosure. Sniffer probes attached to helium mass spectrometer leak detectors are normally designed for leak location, a qualitative inspection technique intended to pinpoint where a leak is but not to quantify its rate of discharge. The main conclusion of the present effort is that local leakage measurement by a leak detector with a sniffer probe is feasible provided one has: (1) quantitative data on the performance of the mass separator cell (a device interior to the unit where the stream of fluid in the sample line branches); and (2) a means of stabilizing the mass transfer boundary layer that is created near a local leak site when a sniffer probe is placed in its immediate vicinity. Theoretical models of the mass separator cell are provided and measurements of the machine-specific parameters in the formulas are presented. A theoretical model of a porous probe end for stabilizing the mass transfer boundary is also presented.

Russell, John M.↗

Fabrication and characterization of Al{sub 2}O{sub 3} /Si composite nanodome structures for high efficiency crystalline Si thin film solar cells

We report on our fabrication and characterization of Al{sub 2}O{sub 3}/Si composite nanodome (CND) structures, which is composed of Si nanodome structures with a conformal cladding Al{sub 2}O{sub 3} layer to evaluate its optical and electrical performance when it is applied to thin film solar cells. It has been observed that by application of Al{sub 2}O{sub 3}thin film coating using atomic layer deposition (ALD) to the Si nanodome structures, both optical and electrical performances are greatly improved. The reflectivity of less than 3% over the wavelength range of from 200 nm to 2000 nm at an incident angle from 0° to 45° is achieved when the Al{sub 2}O{sub 3} film is 90 nm thick. The ultimate efficiency of around 27% is obtained on the CND textured 2 μm-thick Si solar cells, which is compared to the efficiency of around 25.75% and 15% for the 2 μm-thick Si nanodome surface-decorated and planar samples respectively. Electrical characterization was made by using CND-decorated MOS devices to measure device’s leakage current and capacitance dispersion. It is found the electrical performance is sensitive to the thickness of the Al{sub 2}O{sub 3} film, and the performance is remarkably improved when the dielectric layer thickness is 90 nm thick. The leakage current, which is less than 4x10{sup −9} A/cm{sup 2} over voltage range of from -3 V to 3 V, is reduced by several orders of magnitude. C-V measurements also shows as small as 0.3% of variation in the capacitance over the frequency range from 10 kHz to 500 kHz, which is a strong indication of surface states being fully passivated. TEM examination of CND-decorated samples also reveals the occurrence of SiO{sub x} layer formed between the interface of Si and the Al{sub 2}O{sub 3} film, which is thin enough that ensures the presence of field-effect passivation, From our theoretical and experimental study, we believe Al{sub 2}O{sub 3} coated CND structures is a truly viable approach to achieving higher device efficiency.

36 MATERIALS SCIENCE↗

Optimizing performance and yield of vertical GaN diodes using wafer scale optical techniques

Abstract To improve the manufacturing of vertical GaN devices for power electronics applications, the effects of defects in GaN substrates need to be better understood. Many non-destructive techniques including photoluminescence, Raman spectroscopy and optical profilometry, can be used to detect defects in the substrate and epitaxial layers. Raman spectroscopy was used to identify points of high crystal stress and non-uniform conductivity in a substrate, while optical profilometry was used to identify bumps and pits in a substrate which could cause catastrophic device failures. The effect of the defects was studied using vertical P-i-N diodes with a single zone junction termination extention (JTE) edge termination and isolation, which were formed via nitrogen implantation. Diodes were fabricated on and off of sample abnormalities to study their effects. From electrical measurements, it was discovered that the devices could consistently block voltages over 1000 V (near the theoretical value of the epitaxial layer design), and the forward bias behavior could consistently produce on-resistance below 2 mΩ cm 2 , which is an excellent value considering DC biasing was used and no substrate thinning was performed. It was found that high crystal stress increased the probability of device failure from 6 to 20%, while an inhomogeneous carrier concentration had little effect on reverse bias behavior, and slightly (~ 3%) increased the on-resistance (R on ). Optical profilometry was able to detect regions of high surface roughness, bumps, and pits; in which, the majority of the defects detected were benign. However a large bump in the termination region of the JTE or a deep pit can induce a low voltage catastrophic failure, and increased crystal stress detected by the Raman correlated to the optical profilometry with associated surface topography.

42 ENGINEERING↗

Understanding peculiarities in the optoelectronic characteristics of light emitting diodes based on (In,Ga)N/GaN nanowires

We investigate the effect of the p-type top contact on the optoelectronic characteristics of light emitting diodes (LEDs) based on (In,Ga)N/GaN nanowire (NW) ensembles grown by molecular beam epitaxy on Si substrates. We compare devices fabricated with either Ni/Au or indium tin oxide (ITO) top contact. The NW-LEDs with ITO exhibit a number density of NWs emitting electroluminescence about ten times higher, significantly lower turn-on voltage and series resistance, and a relative external quantum efficiency more than one order of magnitude higher than the sample with Ni/Au. These results show that limitations in the performance of such devices reported so far can be overcome by improving the p-type top-contact.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Filtering device

An electrical filter for removing noise from a voice communications signal is reported; seven sample values of the signal are obtained continuously, updated and subjected to filtering. Filtering is accomplished by adding balanced, with respect to a mid-point sample, spaced pairs of the sampled values, and then multiplying each pair by a selected filter constant. The signal products thus obtained are summed to provide a filtered version of the original signal.

Edwards, T. R.↗

Balanced mechanical resonator for powder handling device

A system incorporating a balanced mechanical resonator and a method for vibration of a sample composed of granular material to generate motion of a powder sample inside the sample holder for obtaining improved analysis statistics, without imparting vibration to the sample holder support.

Sarrazin, Philippe C.↗

In situ SEM and ToF-SIMS analysis of IgG conjugated gold nanoparticles at aqueous surfaces

In this study, we report new results of in situ study of 5 nm goat anti-mouse IgG gold nanoparticles in a novel portable vacuum compatible microfluidic device using scanning electron microscope (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The unique feature of the liquid flow cell is that the detection window is open to the vacuum allowing direct probing of the liquid surface. The flow cell is composed of a silicon nitride (SiN) membrane and polydimethylsiloxane (PDMS), and it is fully compatible with vacuum operations for surface analysis. The aperture can be drilled through the 100 nm SiN membrane using a focused ion beam. Characteristic signals of the conjugated gold nanoparticles were successfully observed through the aperture by both energy-dispersive X-ray spectroscopy (EDX) in SEM and ToF-SIMS. Comparison was also made among wet samples, dry samples, and liquid sample in the flow cell using SEM/EDX. Stronger gold signal can be observed in our novel portable device by SEM/EDX compared with the wet or dry samples, respectively. Our results indicate that analyses of the nanoparticle components are better made in their native liquid environment. This is made possible using our unique microfluidic flow cell.

aqueous surface↗