Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Retrofit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Safeguards Modeling for Advanced Nuclear Facility Design.

Future nuclear fuel cycle facilities will see a significant benefit from considering materials accountancy requirements early in the design process. The Material Protection, Accounting, and Control Technologies (MPACT) working group is demonstrating Safeguards and Security by Design (SSBD) for a notional electrochemical reprocessing facility as part of a 2020 Milestone. The idea behind SSBD is to consider regulatory requirements early in the design process to provide more optimized systems and avoid costly retrofits later in the design process. Safeguards modeling, using single analyst tools, allows the designer to efficiently consider materials accountancy approaches that meet regulatory requirements. However, safeguards modeling also allows the facility designer to go beyond current regulations and work toward accountancy designs with rapid response and lower thresholds for detection of anomalies. This type of modeling enables new safeguards approaches and may inform future regulatory changes. The Separation and Safeguards Performance Model (SSPM) has been used for materials accountancy system design and analysis. This paper steps through the process of designing a Material Control and Accountancy (MC&A) system, presents the baseline system design for an electrochemical reprocessing facility, and provides performance metrics from the modeling analysis. The most critical measurements in the electrochemical facility are the spent fuel input, electrorefiner salt, and U/TRU product output measurements. Finally, material loss scenario analysis found that measurement uncertainties (relative standard deviations) for Pu would need to be at 1% (random and systematic error components) or better in order to meet domestic detection goals or as high as 3% in order to meet international detection goals, based on a 100 metric ton per year plant size.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

NRIC Asset Suite Engineering and Operations Data Integration Plan

The National Reactor Innovation Center (NRIC), established by the U.S. Department of Energy (DOE) in August 2019, accelerates the demonstration and deployment of advanced nuclear energy through its mission to inspire stakeholders and the public, empower innovators, and deliver successful outcomes through efficient coordination of partners and resources. NRIC is a national program led by Idaho National Laboratory (INL), enabling collaborators to harness the world-class capabilities of the U.S. National Laboratory System. Committed to demonstrating advanced reactors by the end of 2025, NRIC is designed to bridge the gap between research, development, and the marketplace to help convert some of the Nation’s most promising advanced nuclear reactors into commercial applications by 2030. To meet these needs, NRIC is developing two reactor demonstration test beds at Idaho National Laboratory (INL), the Laboratory for Operation and Testing in the United States (LOTUS) and the Demonstration and Operation of Microreactor Experiments (DOME) test bed. Each test bed involves the modification of existing facilities at INL’s Materials and Fuels Complex (MFC). Retrofitting these facilities to accommodate novel reactors, as well as subsequent but similar NRIC projects, is a non-trivial engineering task and is expected to generate a significant amount of new and revised documentation. Leveraging digital engineering practices, this documentation will be managed in a purpose-built data management tool to facilitate origination, review, and approval while coordinating with the design contractor. The subsequent upload and review of documentation to INL’s existing document control system comprises a long and unnecessarily manual task. An opportunity exists to automate this upload process and save job-hours while continuing to adhere to INL/MFC document management procedures.

99 GENERAL AND MISCELLANEOUS↗

Integrated Controls for Plug Loads and Lighting Systems - Case Study: Minnesota DOT Cedar Avenue Truck Station

This case study highlights the strategies the Minnesota Department of Transportation used at Cedar Avenue Truck Station for integrating plug load and lighting systems. An integrated controls pilot project with retrofit installation was conducted from October 2019 to April 2020 and was recognized by DOE's Integrated Lighting Campaign.

integrated lighting, lighting, controls, plug load↗

An Energy Calculator for Simple Commercial Buildings

According to the EIA, simple commercial buildings account for 97% of total commercial building stock. However, most simple commercial buildings for example small- to mid-sized offices, retail, schools and warehouses do not benefit from the data-driven decision-making capabilities of whole-building energy modeling. The high cost of custom modeling limits the use of energy modeling of simple buildings for new construction or retrofit measures. Lack of tools providing helpful information on interactive savings estimates creates difficulties in meeting aggressive decarbonization and energy efficiency goals for simple building designers and utility program managers. This paper reviews a beta phase Simple Building Calculator with the ability to generate relatively accurate and interactive modeling results based on a limited but robust set of inputs. It can evaluate whole-building or single measure savings in new or existing buildings, compare measure package choices, or provide simplified performance modeling for energy codes and utility incentives. The tool combines physical (annual whole building prototype simulation) and statistical modeling techniques to predict annual energy performance. It supports a variety of building characteristics for envelope, HVAC, and lighting with parameters ranging from vintage to max tech configurations, as well as support for single-zone and simple multi-zone HVAC systems. The Simple Building Calculator was designed to provide immediate feedback for otherwise computationally intensive tasks like measure comparison, development of multiple measure package combinations, or verification that measures meet efficiency targets—all with the goal of providing a tool for quick annual energy simulation of simple commercial buildings.

Hart, Reid↗

A New Gold Mine? Achieving HVAC Energy Efficiency Through a System Metric

Washington State's Commercial Energy Code adopted a new energy metric called HVAC Total System Performance Ratio (TSPR) in 2019, a first in the codes world to regulate HVAC system efficiency. TSPR is a ratio of annual heating and cooling loads to the annual carbon emissions associated with the energy consumed by the HVAC system. TSPR provides a performance-based solution to evaluate and improve the overall HVAC design. The TSPR metric and its companion calculation tool were developed by Pacific Northwest National Laboratory (PNNL) with support from U.S. Department of Energy (DOE), Northwest Energy Efficiency Alliance (NEEA) and the City of Seattle. The new metric represents a significant shift in how HVAC design will meet code requirements. Utility programs can also leverage TSPR as a measure to determine energy savings and incentive amounts for HVAC retrofits. This paper describes the efforts by NEEA and its collaborators to prepare the market for TSPR adoption in code. This paper provides the pilot projects led by University of Washington Integrated Design Lab (IDL) to understand potential issues that could be faced by early adopters. This paper also covers how training and outreach provide engagement opportunities that can streamline code compliance, help address issues faced by early adopters and promote participation in utility programs. As Washington State works on the goals of 70% energy reduction and zero fossil-fuel greenhouse gas emission homes and buildings by the year 2031 , system level performance metrics will likely become increasingly more necessary and prevalent. This paper concludes that the HVAC TSPR requirement helps familiarize the HVAC industry with this approach and helps Washington achieve its long-term goals.

Liu, Bing↗

A High-Granularity Approach to Modeling Energy Consumption and Savings Potential in the U.S. Residential Building Stock: Preprint

Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper will describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.

building stock↗

Validation of HVAC Hardware-in-the-Loop Simulation for Advanced Control Strategies in Smart Homes: Preprint

Residences with smart thermostats can use advanced control strategies to manage their cooling/heating demand, but it is difficult to evaluate optimal control strategies for flexible heating, ventilation, and air conditioning (HVAC) systems in a traditional laboratory setting. The HVAC hardware-in-the-loop (HIL) system combines physical HVAC equipment and a physical thermostat with a simulated house to enable realistic operation of the hardware in any climate. This HIL platform allows researchers to evaluate advanced control strategies for homes with different construction or vintage types, as well as different climates and occupancy schedules. To demonstrate the capabilities of the HVAC HIL system, experimental results with a SEER 16, HSPF 9.5, 3 ton single-speed air source heat pump are validated against past field data collected from a heavily instrumented, unoccupied, retrofit house located in Sacramento, California. Three different cooling strategies are recreated in the HVAC HIL platform, including two different pre-cooling schedules that were designed to shift energy use away from the evening peak. The room temperatures, heat pump energy use, and run time show good agreement between the field data and HIL experimental results for three strategies.

cooling strategies↗

In Hot Water! The Challenges and Barriers of Decarbonizing Water Heating in Multifamily Buildings: Preprint

Domestic hot water heating is responsible for 32% of the total energy consumption in multifamily buildings and offers a significant decarbonization opportunity. An extensive market assessment was conducted to understand and document key technical and economic barriers to electrification of domestic water heating in multifamily buildings throughout the U.S. Through the program, 77 interviews were conducted to understand key market drivers and technical challenges associated with electrification of water heating systems in both retrofit and new construction scenarios. Interviewees encompassed a wide range of stakeholders in the ecosystem surrounding water heating systems, including suppliers, manufacturers, designers, owners, utilities, and developers. This paper documents key interview takeaways, including an extensive list of market barriers, technical challenges, and sought-after technology attributes that can inform pertinent design criteria for electric water heating research, development, and deployment efforts. Among economics and energy efficiency features, interviewees overwhelmingly alluded to space constraints, cold air exhaust, and lack of clear guidance regarding distributed versus centralized design selections as key challenges associated with mass adoption of electric water heating. Owners and developers seek systems with minimal footprint, which maximize rentable space and profits. Moreover, distributed heat pump solutions should balance ducting costs that mitigate cold exhaust entrainment into conditioned zones. Lastly, the market needs clear guidance regarding the selection of distributed versus central electric hot water systems.

challenges of water heating electrification↗

A Technical-Economic Assessment of Brackish Water Treatment for Fossil Power Plant Cooling with Reduced Environmental Impact

The power sector accounts for approximately 40% of freshwater use in the U.S. Reusing non-traditional water resources is critical for alleviating water stress in the western United States. The purpose of this study is to conduct a techno-economic system analysis to evaluate the potential of brackish water treatment for wet cooling towers at existing thermo-electric generating units (EGUs). It aims to address current knowledge gaps in support of non-traditional water resources planning and the electric power industry's water decision- and policy making. An engineering-economic model was developed and combined with DuPont's water application value engine (WAVE) v1.82 to evaluate the viability of retrofitting reverse osmosis-based brackish water treatment systems to individual existing EGUs and then aggregating the unit-level results to the fleet level. In the base case, brackish water treatment can reduce freshwater consumption of electric generation units by 94–100% while increasing the cost of electric generation by approximately 10% and have marginal impacts on the units' parasitic loads. When zero liquid discharge systems are applied to brackish water brine treatment, the cost of electric generation and freshwater consumption savings and energy penalty to the power plant significantly increase. These costs are even higher than dry cooling deployment in lieu of wet cooling towers. The choice of freshwater savings between brackish water desalination and dry cooling deployment depends greatly on how the concentrated brines are managed. Multiple factors must be considered when supporting decision-making in water management and planning in power sectors, which include non-traditional water quantity and quality as well as trade-offs among technical performance, economics, and environmental impacts.

Wu, Zitao↗

Convincing Clients to Make Zero a Reality: Preprint

As buildings are the largest end-users of carbon-intensive energy in the United States, it is critical that design and construction professionals implement energy-efficient and sustainable building designs and systems. Building owners seeking building energy performance improvements, either with new construction or retrofit of existing facilities, usually need the expertise of design and construction professionals to guide them through the process. These "trusted advisers" make the design decisions that ultimately result in the energy performance of the building. Members of the design and construction community have identified that clients' perception of cost associated with such designs and building upgrades have posed the most significant barrier to increased adoption. If solved, this would enable design and construction firms to better engage as trusted advisors along the lines of energy and carbon reduction of the built environment. NREL has developed a resource that helps design and construction professionals and their clients match their projects with financial incentives. A newly developed cohort of design and construction professionals, as part of the U.S. Department of Energy's Better Buildings Initiative, has brought real-world project experiences to the development process, contributing meaningful insights that have been critical to evaluating the successes of and providing direction to this much needed financial guide.

Better Buildings↗

Advancing Clean Energy Equity

This year’s Financial Innovations Roundtable (June 16-17, 2022) focused on advancing clean energy equity and was co-hosted by the University of New Hampshire's Carsey School of Public Policy and the Federal Reserve Bank of New York. Clean energy technologies are better than ever, with costs continuing to decline. Yet the low-income and under-resourced communities – particularly communities of color, Native communities, and other traditionally marginalized populations – that are disproportionately impacted by climate and severe weather-related events lag in clean energy investments. Community Development Financial Institutions (CDFIs) have a long track record of providing access to capital to low- and moderate-income communities nationwide. Green Banks, established at state and local levels, use innovative financing to attract private capital and incentivize investments in clean and renewable energy. Together, the nation's network of more than 1,300 CDFIs and 21 Green Banks have the financing expertise and deep market understanding and relationships to finance a transition to clean energy. This event explored how Green Banks and CDFIs can funnel creditworthy projects to market and efficiently raise capital for them. Building on the Carsey School White Paper, Clean Energy Project Development for Low-Income Communities: Strengthening the Ecosystem for Delivering Solar Energy and Deep Efficiency Retrofits (Hangen, 2022), the FIR sought to identify options and create opportunities for Green Banks, CDFIs, and impact investors to collaborate in offering a range of products, approaches, and tools to better serve communities and individuals who have thus far been left out of the transition to clean energy. The event had 101 participants from a variety of sectors including CDFIs, Green Banks, mission-driven clean energy organizations, government agencies, banks, and impact investment professionals.

14 SOLAR ENERGY↗

Better bang for your buck? Comparing savings realization from ESPCs and direct-funded projects

Energy savings performance contracts (ESPCs) offer an opportunity to tremendously scale decarbonization projects, given their paid-from-savings premise. However, prospective customers still question whether ESPC is worth the effort and expense. This study evaluates the savings realization rates of ESPCs compared to direct-funded projects using ENERGY STAR Portfolio Manager (ESPM) benchmarking data. It compares normalized EUIs from ESPM before and after energy conservation projects implemented via ESPC or direct funding in roughly 450 federal buildings. This documented change, ideally a savings, can then be compared to the estimated savings from the energy conservation initiative in order to generate a rough realization rate. Preliminary results indicate a notably greater savings realization rate for the ESPC buildings (median = 105% of estimated savings) than those that underwent direct-funded projects (median = 46%). Because of a shortage of good quality data and the wide range in results, the difference is only significant at the p < 0.20 level. However, the higher savings realization of ESPCs corroborates the authors’ 2014 findings using a different comparison method. With continued soft government funding and regulatory impediments for climate change mitigation in the U.S., financed, paid-from-savings project models (e.g., ESPC, PACE, EaaS and others) certainly merit more attention. This study’s results are particularly compelling (and encouraging) given the country’s likely reliance on these vehicles to address existing building retrofits.

Earni, Shankar↗

Market-Integrated Optimization of Wind-Battery-Hydrogen Hybrids for Peaking Capacity via Storage

As Integrated Energy Systems (IES) combine multiple energy and storage technologies to provide potentially more value and less risk via resource diversification, complementary overbuild, increased flexibility, and revenue-stacking, IES value is dependent on electricity market dispatch and grid interactions should play an important role in IES design and operation. This study hybridizes and retrofits wind and combustion turbine plants to study the impacts of replacing gas generation capacity with wind, battery, PEM electrolysis, hydrogen tanks and hydrogen turbines. The optimized design is co-simulated in a production cost model with different bidding strategies in order to compare performance and highlight the importance of grid-interactions. We analyze the revenue and dispatch changes as well as the price and cost implications of wind-battery-hydrogen IESs.

electrolysis↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Fort Erie Case Study - Transition from Fixed-Route to On-Demand Transit

Rural and smaller-sized communities in North America face unique mobility challenges due to their low population density, lower public transit spending per capita compared to major cities, and a high reliance on private vehicles. In recent years, communities such as Fort Erie, Ontario, have restructured or advanced their public transit systems using on-demand services. Fort Erie is a relatively sparsely populated region of 32,901 residents, spread across a land area of 166 square kilometers (64 square miles), for an average population density of 193 residents per square kilometer (500 per square mile). In October 2021, the town implemented a mobility-on-demand system integrated with smartphone software to replace its fixed-route community bus system, which consisted of four buses with three routes, each with a roughly 1-hour, one-way loop. The new service utilizes a fleet of six minivans, two of which are retrofitted with wheelchair-accessible ramps. The system may require that a passenger requesting a standard van walk up to 400 meters (a quarter mile) to their pickup location to optimize vehicle routing while providing origin-to-destination service. The on-demand system proved effective in providing service, eclipsing pre-pandemic ridership by 40%, decreasing greenhouse gas emissions per ride by 63%, and decreasing the cost to the town per ride by 29%. This report documents both the previous system and the new system in terms of routes, ridership, costs, fuel, and other notable system parameters. This work is part of an ongoing series of case studies on providing small communities with on-demand, right-sized vehicle service coupled with a smartphone application.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Cold-Climate Packaged Heat Pumps - Resistance is Futile

The U.S. currently has a large market for room/zonal space conditioning equipment focused primarily on cooling, namely packaged terminal air conditioners (PTACs), packaged terminal heat pumps (PTHPs), and room air conditioners. This equipment largely relies on electric resistance for heating, particularly when outdoor temperatures fall to 40°F or below, presenting a compelling opportunity for energy savings and carbon reductions from reverse cycle heating. This paper provides an overview of cold climate packaged heat pump technologies in the market capable of high output down to outdoor temperatures of 5°F and identifies the technological and market barriers to adoption. For state-of-the-art cold climate packaged heat pumps sold in the retrofit market, defrost meltwater management is the principal barrier to implementation. An energy use analysis is conducted on state-of-the-art cold climate packaged heat pumps for heating and cooling loads by building vintage and climate zone. Potential solutions to defrost meltwater are proposed and modeled for their impact on heating energy efficiency. A national impact assessment estimates the aggregate energy savings and carbon reductions if cold climate packaged heat pumps were to replace existing PTACs and PTHPs in the U.S. building stock. A national, two-track approach is proposed for increasing market adoption in the replacement and new construction markets.

ACEEE Summer Study, cold climate, heat pumps, ccph↗

Fast, Accurate, and Reliable Thermal Metrology to Assess the Thermal Resistivity on Small Samples of Thermal Insulation

Developing new insulation materials having a thermal resistivity greater than 69 m K/W (10 hr ft2 °F/Btu/inch) can be appealing for building envelope retrofit and construction of new buildings. Multiple institutions are involved in the development of innovative insulation materials with high thermal resistivity. However, these projects have struggled in the development of new materials due to the difficulty associated with the measurement of small sections of high thermal resistivity materials. As new materials are being developed, the size of each test specimen impacts the cost of development. Given the lack of a reliable method to measure the thermal resistivity on small samples of such materials, we evaluated experimental techniques that can be improved to satisfy the need for testing small sections of high thermal resistivity materials and developed standardized test methods to enable the rapid thermal evaluation of advanced insulation materials. This paper presents the study results and potential techniques for fast, accurate, and reliable effective thermal resistivity measurement on small samples of insulation materials.

Desjarlais, Andre Omer↗