Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Development of an Outdoor Temperature-Based Control Algorithm for Residential Mechanical Ventilation Control

Smart ventilation systems use controls to ventilate more during those periods that provide either an energy or IAQ advantage (or both) and less during periods that provide a dis advantage. Using detailed building simulations, this study addresses one of the simplest and lowest cost types of smart controllers —outdoor temperature- based control. If the outdoor temperature falls below a certain cut- off, the fan is simply turned off. T he main principle of smart ventilation used in this study is to shift ventilation from time periods with large indoor -outdoor temperature differences, to periods where these differences are smaller, and their energy impacts are expected to be less. Energy and IAQ performance are assessed relative to a base case of a continuously operated ventilation fan sized to comply with ASHRAE 62.2-2013 whole house ventilation requirements. In order to satisfy 62.2-2013, annual pollutant exposure must be equivalent between the temperature controlled and continuous fan cases. This requires ventilation to be greater than 62.2 requirements when the ventilation system operates. This is achieved by increasing the mechanical ventilation system air flow rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase I - Smart Grid Data Access Pilot Program: Utilizing STEM Education as a Catalyst for Residential Consumer Decision Making and Change

Under Phase I of the Smart Grid Data Access Pilot Program, the Gulf of Maine Research Institute (GMRI) partnered with Central Maine Power (CMP), and the Maine Mathematics and Science Alliance (MMSA) and engaged key vendors Tilson Government Services, LLC (Tilson), and Image Works to demonstrate the efficacy of PowerHouse, an interactive online learning environment linking middle school students with their home electricity consumption data provided through CMP’s Advanced Metering Infrastructure (AMI). The goal of the program is to harness the power of youth to alter home energy consumption behaviors using AMI data. Successful programs aimed at smoking cessation, recycling, and seat belt use have demonstrated the power of young people to influence household behaviors. In an era of increasing concern about energy costs, availability, and human impacts on global climate, GMRI sought to demonstrate the effectiveness of a student-focused approach to understanding and managing household energy use. We also sought to contribute to a solid foundation of science-literate students who can analyze evidence to find solutions to increasingly complex energy challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sault Tribe Building Efficiency Audits of Tribally-Owned Governmental Buildings and Residential Tribal Housing

The Tribe is working to reduce energy consumption and expense in Tribally-owned governmental buildings and low income housing sites. In 2009, the Tribe applied to the U. S. Department of Energy for funding to conduct energy audits of Tribally-owned governmental buildings. Findings from the energy audits would define the extent and types of energy efficiency improvements needed, establish a basis for energy priorities, strategies and action plans, and provide a benchmark for measuring improvements from energy efficiency implementations. In 2010, the DOE awarded a grant in the amount of $95,238 to the Tribe to fund the energy audits of nine governmental buildings and to pay for travel expenses associated with attendance and participation at the DOE annual program reviews. In 2011, the Tribe applied for and was awarded a DOE grant in the amount of $75,509 to conduct energy audits of the remaining 30 Tribally-owned governmental buildings. Repeating mobilization steps performed during the first DOE energy audits grant, the Tribe initiated the second round of governmental building energy audits by completing energy auditor procurement. The selected energy auditor successfully passed DOE debarment and Sault Tribe background clearances. The energy audits contract was awarded to U. P. Engineers and Architects, Inc. of Sault Ste. Marie, Michigan. The Tribe continued mobilizing for the energy audits by providing the energy auditor with one year of electric, gas and water utility invoice copies per building, as well as supplemental building information, such as operating hours. The Tribe also contacted building occupants to coordinate scheduling for the on-site energy audit inspections and arranged for facilities management personnel to guide the energy auditor through the buildings and answer questions regarding building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hygric Redistribution in Insulated Assemblies. Retrofitting Residential Envelopes Without Creating Moisture Issues

The Building America program has recognized that most of the current housing stock is in need of energy related retrofits. One of the best ways of reducing the space conditioning energy consumption is to improve the thermal performance of the enclosure by adding exterior board foam insulation. This report quantifies the amount of water that can become trapped in the drainage cavity of typical wall systems, and measures the effect of water trapped in the drainage cavity on the moisture content of the sheathing. This study also attempts to explain the discrepancy between hygrothermal simulations and field performance of low permeance, low R-value exterior insulation (e.g. ¾-in. foil faced polyisocyanurate) in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Selecting Solar. Insights into Residential Photovoltaic (PV) Quote Variation

This analysis leverages available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Residential Cooking Behavior in the United States: Data Collected from a Web-Based Survey

Cooking has a significant impact on indoor air quality. When cooking occurs, how foods are cooked, and the types of food that are cooked have all been shown to impact the rate at which occupants are exposed to pollutants. Home occupancy characteristics impact how concentrations in the home translate into exposures for the occupants. With the intent of expanding our understanding of cooking behavior in the U.S., we developed and advertised an online survey to collect household cooking behavior for the 24 hrs prior to taking the survey. The survey questions were designed to address gaps in knowledge needed to predict the impact of cooking on indoor concentrations of PM2.5 and other pollutants. The survey included the following questions: 1) which meals households ate at home; 2) number of household members at home during cooking; 3) the type of oil used for cooking; 4) the type of foods cooked at each meal; 5) the type of cooking devices used; and 6) the methods selected for food preparation. We also collected information on household characteristics such as their location (zip code), ethnicity, and ages of family members. We analyzed the variability in home cooking characteristics for households in different climate zones and with four different types of family compositions: 1 senior living alone, 1 adult living alone, 2 or more adults/seniors, and families with children. We used simple statistical tests to determine if the probability of certain cooking behaviors differed between these subgroups.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Looking For Value in All The Wrong Places. Toward Expanded Consideration of Green and High Performance Attributes in Non-residential Property Appraisals in the United States

Large numbers of commercial buildings have sought to improve their energy and environmental performance, with half of all leasable U.S. offices now designated at some level of “green”. All proper/es fall somewhere on the green/high-­performance spectrum (above and below average) whether or not they bear a formal label or ra/ng.1 Variations in the level of performance can either positively or negatively influence value. This component of value can be shaped by many factors, from utility costs to tenant/owner preferences that translate into income (rent levels, vacancy rates, lease-­up /mes, etc.). Occupant perceptions of indoor environmental quality are another potential influence on value. While there has been little uptake of this thinking by practicing appraisers, the increased prevalence of green/HP practices combined with concerns about appraiser competency are compelling the industry to adapt their traditional techniques to this new driver of value. However, the overly narrow focus of policymakers on appraisal of labeled or rated exemplary buildings (e.g., LEED or ENERGY STAR Certified) represents a significant missed opportunity. Any level of green or energy performance can in fact influence value, including below-­average performance (a.k.a. “brown discount”), irrespec/ve of whether or not the building has been formally rated. Another surmountable challenge is the limitations to non-­appraisers’ understanding of the appraisal process (and constraints therein). A crucial byproduct of this is unrealistic expectations of what appraisers can and will do in the marketplace. This report identifies opportunities for catalyzing improvement of the green/HP appraisal process, which apply to all involved actors—from owner, report-­ordering client, the appraiser, and the appraisal reviewer—and fostering more demand for appraisals that recognize green/HP property attributes. The intended audience is primarily the public policy community and other stakeholders outside the formal appraisal community who can contribute to the broader effort to advance professional practces. The discussion begins with a descripton of the appraisal process and the points at which green/HP consideratons can enter the analysis. A series of major barriers to better practces are identfied along with approaches to reducing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experiences of Vulnerable Residential Customer Subpopulations with Critical Peak Pricing

DOE decided to co-fund ten utilities to undertake eleven experimentally-designed Consumer Behavior Studies (CBS) that proposed to examine a wide range of the topics of interest to the electric utility industry. Each chosen utility was to design, implement and evaluate their own study in order to address questions of interest both to itself and to its applicable regulatory authority, whose approval was generally necessary for the study to proceed. The DOE Office of Energy Delivery and Electricity Reliability (OE), however, did set guidelines, both in the FOA and subsequently during the contracting period, for what would constitute an acceptable study under the Grant. To assist in ensuring these guidelines were adhered to, OE requested that LBNL act as project manager for these Consumer Behavior Studies to achieve consistency of experimental design and adherence to data collection and reporting protocols across the ten utilities. As part of its role, LBNL formed technical advisory groups (TAG) to separately assist each of the utilities by providing technical assistance in all aspects of the design, implementation and evaluation of their studies. LBNL was also given a unique opportunity to perform a comprehensive, cross-study analysis that uses the customer-level interval meter and demographic data made available by these utilities due to SGIG-imposed reporting requirements, in order to analyze critical policy issues associated with AMI-enabled rates and control/information technology. LBNL will publish the results of these analyses in a series of research reports, of which this is one, that attempt to address critical policy issues relating to a variety of topics including customer acceptance, retention and load response to time-based rates and various forms of enabling control and information technologies. This report extends the existing empirical literature on the experiences of low-income customers exposed to critical peak pricing, and provides the first glimpses into the experiences of the elderly and those who reported being chronically ill. Specifically, we analyzed two of the time-based rate consumer behavior studies, which were co-funded by the Department of Energy as part of the Smart Grid Investment Grant program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High Efficiency Water Heating Technology Development Final Report, Part II: CO 2 and Absorption-Based Residential Heat Pump Water Heater Development

The two objectives of this project were to 1.demonstrate an affordable path to an ENERGY STAR qualified electric heat pump water heater (HPWH) based on low-global warming potential (GWP) CO 2 refrigerant, and 2.demonstrate an affordable path to a gas-fired absorption-based heat pump water heater with a gas energy factor (EF) greater than 1.0. The first objective has been met, and the project has identified a promising low-cost option capable of meeting the second objective. This report documents the process followed and results obtained in addressing these objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Small Business Voucher CRADA Report: Natural Gas Powered HVAC System for Commercial and Residential Buildings

Be Power Tech is commercializing BeCool, the first integrated electricity-producing heating, ventilation, and air conditioning (HVAC) system using a non-vapor compression cycle (VCC), packaged rooftop HVAC unit that also produces base-load electricity, heating, ventilation, and air conditioning. BeCool is a distributed energy resource with energy storage that eliminates the tremendous peak electricity demand associated with commonly used electricity-powered vapor compression air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 5: Residential Furnaces and Boilers Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The high-efficiency boiler and furnace measure produces gas heating savings resulting from installation of more energy-efficient heating equipment in a residence. Such equipment, which ranges in size from 60 kBtu/hr to 300 kBtu/hr, is installed primarily in single-family homes and multifamily buildings with individual heating systems for each dwelling unit. This protocol does not cover integrated heating and water heating units which can be used in lieu of space heating only equipment.

09 BIOMASS FUELS↗

Energy Savings Analysis of the Proposed Revision of the Washington D.C. Non-Residential Energy Code

This report presents the results of an assessment of savings for the proposed Washington D.C. energy code relative to ASHRAE Standard 90.1-2010. It includes annual and life cycle savings for site energy, source energy, energy cost, and carbon dioxide emissions that would result from adoption and enforcement of the proposed code for newly constructed buildings in Washington D.C. over a five year period.

Commercial Energy Code↗

Tribal Renewable Energy Report - Final Report: Bishop Paiute Tribe Residential Solar Program. Phase 1 (DOE Award # DE-EE0006949)

The objective of the project was to provide affordable renewable energy to 22 low income reservation homeowners; provide job training to tribal members and reduce air pollution by equivalent carbon offsets. The project exceeded grant objectives installing 66kW of rooftop solar on 22 low income single family homes and providing hands-on PV rooftop solar installation training to 24 tribal individuals (four more than planned). The project was a phased installment of an on-going partnership between the Tribe and GRID that was initiated in 2013 whereby 62 rooftop solar units were installed prior to this funded effort. The reported work in this report describes the funded effort where US Department of Energy provided partial funding through grant award IE0006949 and marks the first phase of an effort matching California Solar SASH Initiative funding with DOE Office of Indian Energy Funding and brings the total for the program to 84 installed systems (running total of 271 Kw installed) and the end of the project. Tribal workforce development was a key aspect of the project and trained 24tribal members for a total 1168 cumulative on-job training hours. The solar installations and training efforts were fully completed by September of 2016 with 66.6 kW installed - 8 kW more than the original estimate stated in the grant application.

14 SOLAR ENERGY↗

Investigate Strategies to Increase Residential Energy Code Compliance Rates and Measure Results in North Carolina: Final Report

The proposed project implemented and tested methods to assess compliance with the energy code, developed educational programs and resources targeted at key compliance issues, conducted a statewide outreach and training campaign, taught building and inspection professionals about key issues of compliance with the energy code, and conducted a follow-up study to see how compliance rates changed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications - Design and Simulation Practice to Identify Charge Reduction Opportunities for Residential AC/HP Units

Based on three 5-ton, single-speed heat pumps (HPs), using R-410A, which use the same compressor, indoor blower and outdoor fan, the DOE/ORNL Heat Pump Design Model was used to conduct comparative modelling study. Regarding charge reduction opportunities, in general, we recommend: 1. Downsizing the outdoor condenser will reduce the required system charge, i.e. using smaller tube diameters or fewer tubes; reducing the evaporator inner volume is less important; to offset the reduced condenser tube side surface area, one can increase the air side surface area (fin density) or condenser air flow rate via using a more efficient fan. 2. microchannel heat exchangers are most effective in reducing the required charge, by up to 60% in the condenser and evaporator. To develop low charge systems, one should at least use a microchannel heat exchanger as the outdoor condenser. 3. TXV systems are less sensitive to charge reduction. For the drop-in application, one can decrease the charge to minimize the liquid section in the condenser, at the expense of minor performance degradation; for example, when reducing the system charge by 15% (decrease the subcooling degree to 2R), the simulation results prove that the decrease is less than 3% in the EER and less than 6% in the capacity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent Energy Optimizer for Residential Buildings

Demand-side management in the buildings is essential for meeting grid flexibility needs in a highly renewable energy scenario. Appliance load monitoring helps decision making for demand-side management by providing the information on operation status/power consumption from different appliances in the buildings. Nonintrusive load monitoring (NILM) is an attractive option for appliance load monitoring using because it has lower cost for sensors and helps mitigate privacy concerns. In this study, the team used an event detection technique followed by two different methods for event classification. The results from k-means clustering showed that the events from a single appliance are often distributed in multiple clusters. Thus, the unsupervised method of NILM using k-means clustering used in this study was not very suitable for load disaggregation. The results from NILM showed that the F1 score for event classification was 0.77 for a heat pump water heater and very low for other appliances using the rule-based classification.

24 POWER TRANSMISSION AND DISTRIBUTION↗