Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,055 records · Page 59

Global SO 2 Data Record from OMPS Instruments on the JPSS Constellation

NASA’s Earth Observing System (EOS) SO 2 climate data record (CDR) started in 2004, with the launch of the Aura/Ozone Monitoring Instrument (OMI) and is now being continued with the SNPP/Ozone Mapping and Profiler Suite (OMPS) launched in 2011. Both OMI and SNPP/OMPS SO 2 CDRs are produced with the Goddard principal component analysis (PCA) spectral fitting algorithm. An advantage of the data-driven PCA retrieval technique is that it enables highly consistent retrievals from different instruments, by inherently accounting for various instrumental factors. To further extend the EOS SO 2 CDR, we are implementing the PCA SO 2 retrieval algorithm with the L1B measurements from OMPS instruments flying on the Joint Polar Satellite System (JPSS) constellation. In this presentation, we will provide an update on our progress in NOAA-20 (launched in 2017) and NOAA-21 (launched in 2022) PCA SO2 retrievals. We will focus on our new NOAA-20/OMPS PCA SO 2 EOS continuity product, to be publicly released in fall of 2023. We will present statistical analyses on the quality of NOAA-20 PCA SO 2 product, including retrieval noise, biases over background areas, and long-term stability. We will compare our PCA SO 2 retrievals from NOAA-20 with those from OMI, SNPP/OMPS, and S5P/TROPOMI (TROPOspheric Monitoring Instrument) for anthropogenic sources as well as large volcanic plumes. We will also discuss the application of a new machine learning technique that helps to further reduce the noise of NOAA-20 SO 2 retrievals. In addition, we will present preliminary PCA SO 2 retrievals from NOAA-21/OMPS, including those from direct readout implementation for aviation disaster avoidance. Finally, we will share some first results applying the PCA algorithm to NASA’s geostationary TEMPO (Tropospheric Emissions: Monitoring of Pollution) instrument to obtain hourly, high resolution SO 2 data over North America.

SO2↗

Large-Scale Magnetic Microcalorimeter: Modeling and Multiplexing

We will present performance predictions for a large-scale magnetic microcalorimeter detector array intended for a potential future X-ray astrophysics mission. The focal plane comprises three distinct array designs, necessitating over 100,000 pixels to meet the scientific objectives. Our presentation will describe the results of numerical modeling aimed at estimating the energy resolution and detector responses for each array. Additionally, we will discuss the application of microwave multiplexing technology for the comprehensive readout of the entire sensor array.

x-ray↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

Anomaly Detection for the Roman Space Telescope Wide Field Instrument’s Science Data Processing Pipeline

The Roman Space Telescope (RST) Wide Field Instrument (WFI) will be utilizing a preliminary Science Data Processing (SDP) pipeline during its Integration and Test, and to some extent during Operations, to track basic statistics and identify known features such as cosmic rays, snowballs as well as possible anomalies in raw detector data. In our detectors, these anomalies appear as jumps in the ramp of a readout and are classified as cosmic rays if they appear as a streak or snowballs if they’re more circular. The WFI employs an array of 18 H4RG-10 detectors that collect image samples. Each set of raw frames within a non-destructive exposure is packaged by the SDP pipeline into image cubes for each detector. Each cube is a time series of 4096 × 4096 accumulating pixel frames. The preliminary analysis pipeline is used to locate anomalies in these time-series accumulation frames and identify the type of anomaly, either natural phenomena or detector characteristic. To compare different methods, we’ve implemented both heuristic-based and data-driven methods to identify anomalies. For the heuristic-based approach, we identify snowballs and cosmic rays by the size and shape of outlier pixel clusters between consecutive frames. For data driven methods, we evaluated a Convolutional Neural Network (CNN) model, and more traditional methods like Principal Component Analysis (PCA). CNN is a supervised learning/classification method. Thus, we used a labeled dataset of anomalies to perform segmentation of the image and identify anomalies. We used previously identified cosmic rays and snowballs to measure the accuracy and efficiency of the mentioned approaches. In evaluating these methods, we aim to pick the best fit for the SDP pipeline’s anomaly detection in terms of both performance and runtime.

Paul Horton↗

Development of the Microcalorimeter Detector for Athena/X-IFU

The X-ray Integral Field Unit (X-IFU) will be a microcalorimeter instrument on ESA’s Athena X-ray observatory, set to launch around 2037. Athena recently underwent a reformulation exercise resulting in a simplified X-IFU architecture, with a new baseline configuration featuring fewer pixels and readout channels. Newly developed transition edge sensor pixels that are slower and have reduced magnetic field sensitivity have helped enable the new instrument design whilst maintaining flagship quality science. In this paper, we report on the status and plan for continued development of the X-IFU microcalorimeter array. We describe details of the current pixel architecture and performance specifications. We will present the design of the first full scale microcalorimeter arrays that have the necessary flight like electrical and mechanical interfaces for X-IFU. These arrays will undergo testing in a focal-plane assembly (FPA) Development Model (DM) in Europe later in 2024 and serve as a precursor to the X-IFU Engineering Model detector.

Stephen J Smith↗

Superfluid-Tight Cryogenic Receiver With Continuous Sub-Kelvin Cooling for EXCLAIM

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 – 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast integration in dark atmospheric windows. The telescope receiver is cooled to ≈ 1.7 K by immersion in a superfluid helium bath and enclosed in a superfluid-tight shell with a meta-material anti-reflection coated silicon window. In addition to the optics and the spectrometer package, the receiver contains the magnetic shielding, the cryogenic segment of the spectrometer readout, and the sub-Kelvin cooling system. A three-stage continuous adiabatic demagnetization refrigerator (CADR) keeps the detectors at 100 mK while a 4He sorption cooler provides a 900 mK thermal intercept for mechanical suspensions and coaxial cables. We present the design of the EXCLAIM receiver and report on the flight-like testing of major receiver components, including the superfluid-tight receiver window and the sub-Kelvin coolers.

continuous adiabatic demagnetization refrigerator↗

Multiplexing of Hot-Electron Nanobolometers Using Microwave SQUIDs

We have obtained the first data on the multiplexed operation of titanium hot-electron bolometers (HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far-infrared spectroscopy and mid- and near-IR calorimetry. However, the short time constant of these devices (approximately microseconds at 300-400 mK) makes time domain or audio-frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to X-band microresonators which are, in turn, coupled to a transmission line. We used a 4-element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10-MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1-dB per ??/2 responsivity was sufficient for keeping the system noise at the level of ~ 2 pA/Hz1/2. This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near- IR photons (1550 nm) with a time constant of 3.5 ?s. Follow-on work will scale the array to larger size and will address the microwave frequency signal generation and processing using a digital transceiver.

microwave readout↗

Advanced Electronics for the SONTRAC Neutron Spectrometer

Solar neutrons are the tell-tale of highly energetic processes (e.g. solar flares) at the Sun in which particle acceleration is taking place over a broad range in energy. Unlike charged radiation, neutrons escape unscathed from the ambient magnetic fields, providing a view of particle acceleration unhindered by the effects of transport. High-energy neutrons are challenging to measure with the traditional double scatter technique based on time-of-flight (ToF). This technique is limited by the finite flight path and active scintillator sizes required by small satellite platforms. The new SOlar Neutron TRACking (SONTRAC) concept, based on scintillating-fiber bundles, will provide high resolution imaging of fast neutrons at energies where the bulk of solar and magnetospheric neutrons resides. Recent development of the new SONTRAC instrument concept's advanced electronics and processing algorithms are presented.

SiPM readout↗