Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUARTZ”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Toxicity of Carbon Nanotubes in the Lungs of Mice 7 and 90 Days After Intratracheal Instillation

Single-walled carbon nanotubes have many potential applications in the electronic, computer, and aerospace industries. Because unprocessed nanotubes could become airborne and potentially reach the lungs, their pulmonary toxicity was investigated. The three products studied were made by different methods, and contained different types and amounts of residual catalytic metals. Mice were each intratracheally instilled once with 0,0.1 or 0.5 mg of nanotubes, a carbon black negative control, or a quartz positive control, and killed for histopathological study 7 d or 90 d after the treatment. All nanotube products induced epithelioid granulomas and, in some cases, interstitial inflammation in the animals of the 7 -d groups. These lesions persisted and were worse in the 90-d groups. We found that, if nanotubes reach the lung, they can be more toxic than quartz, which is considered a serious occupational health hazard in chronic inhalation exposures.

Lam, Chiu-Wing↗

Upheaval Dome, An Analogue Site for Gale Center

We propose Upheaval Dome in southeastern Utah as an impact analogue site on Earth to Mars Science Laboratory candidate landing site Gale Crater. The genesis of Upheaval Dome was a mystery for some time--originally thought to be a salt dome. The 5 km crater was discovered to possess shocked quartz and other shock metamorphic features just a few years ago, compelling evidence that the crater was formed by impact, although the structural geology caused Shoemaker and Herkenhoff to speculate an impact origin some 25 years earlier. The lithology of the crater is sedimentary. The oldest rocks are exposed in the center of the dome, upper Permian sandstones, and progressively younger units are well exposed moving outward from the center. These are Triassic sandstones, siltstones and shales, which are intruded by clastic dikes. There are also other clay-rich strata down section, as is the case with Gale Crater. There is significant deformation in the center of the crater, with folding and steeply tilted beds, unlike the surrounding Canyonlands area, which is relatively undeformed. The rock units are well exposed at Upheaval Dome, and there are shatter cones, impactite fragments, shocked quartz grains and melt rocks present. The mineral shock features suggest that the grains were subjected to dynamic pressures> 10 GPa.

Conrad, P. G.↗

The Active Oxidation of Silicon Carbide

The high temperature oxidation of silicon carbide occurs in two very different modes. Passive oxidation forms a protective oxide film which limits further attack of the SiC: SiC(s) + 3/2 O2(g) = SiO2(s) + CO(g) Active oxidation forms a volatile oxide and may lead to extensive attack of the SiC: SiC(s) + O2(g) = SiO(g) + CO(g) Generally passive oxidation occurs at higher oxidant pressures and active oxidation occurs at lower oxidant pressures and elevated temperatures. Active oxidation is a concern for reentry, where the flight trajectory involves the latter conditions. Thus the transition points and rates of active oxidation are a major concern. Passive/active transitions have been studied by a number of investigators. An examination of the literature indicates many questions remain regarding the effect of impurity, the hysteresis of the transition (i.e. the difference between active-to-passive and passive-toactive), and the effect of total pressure. In this study we systematically investigate each of these effects. Experiments were done in both an alumina furnace tube and a quartz furnace tube. It is known that alumina tubes release impurities such as sodium and increase the kinetics in the passive region [1]. We have observed that the active-to-passive transition occurs at a lower oxygen pressure when the experiment is conducted in alumina tubes and the resultant passive silica scale contains sodium. Thus the tests in this study are conducted in quartz tubes. The hysteresis of the transition has been discussed in the detail in the original theoretical treatise of this problem for pure silicon by Wagner [2], yet there is little mention of it in subsequent literature. Essentially Wagner points out that the active-to-passive transition is governed by the criterion for a stable Si/SiO2 equilibria and the passive-to-active transition is governed by the decomposition of the SiO2 film. A series of experiments were conducted for active-to-passive and passive-to-active transitions by increasing and decreasing oxygen pressure, respectively. For pure silicon a dramatic difference was found; whereas for SiC the difference was not as great. This may be due to the oxidation of the carbon in SiC which may break down the scale [3]. The third area is the effect of total pressure. In the literature, low oxygen potentials are achieved via either low total pressure or low oxygen pressure in an O2/Ar mixture. Both types of experiments are done in this study and the differences are discussed with regard to the presence or absence of a boundary layer.

Jacobson, Nathan S.↗

Search for Fluid Inclusions in a Carbonaceous Chondrite Using a New X-Ray Micro-Tomography Technique Combined with FIB Sampling

Early solar system aqueous fluids are preserved in some H chondrites as aqueous fluid inclusions in halite (e.g., [1]). Although potential fluid inclusions are also expected in carbonaceous chondrites [2], they have not been surely confirmed. In order to search for these fluid inclusions, we have developped a new X-ray micro-tomography technique combined with FIB sampling and applied this techniqu to a carbanaceous chondrite. Experimental: A polished thin section of Sutter's Mill meteorite (CM) was observed with an optical microscope and FE-SEM (JEOL 7001F) for chosing mineral grains of carbonates (mainly calcite) and sulfides (FeS and ZnS) 20-50 microns in typical size, which may have aqueous fluid inclusions. Then, a "house" similar to a cube with a roof (20-30 microns in size) is sampled from the mineral grain by using FIB (FEI Quanta 200 3DS). Then, the house was atached to a thin W-needle by FIB and imaged by a SR-based imaging microtomography system with a Fresnel zone plate at beamline BL47XU, SPring-8, Japan. One sample was imaged at two X-ray energies, 7 and 8 keV, to identify mineral phases (dual-enegy microtomography: [3]). The size of voxel (pixel in 3D) was 50-80 nm, which gave the effective spatial resolution of approx. 200 nm. A terrestrial quartz sample with an aqueous fluid inclusion with a bubble was also examined as a test sample by the same method. Results and discussion: A fluid inclusion of 5-8 microns in quartz was clearly identified in a CT image. A bubble of approx. 4 microns was also identified as refraction contrast although the X-ray absorption difference between fluid and bubble is small. Volumes of the fluid and bubble were obtained from the 3D CT images. Fourteen grains of calcite, two grains of iron sulfide and one grain of (Zn,Fe)S were examined. Ten calcite, one iron sulfide and one (Zn,Fe)S grains have inclusions >1 micron in size (the maximum: approx. 5 microns). The shapes are spherical or irregular. Tiny inclusions (<1 micron) are also present in all the grains examined. These results show that mineral grains have more inclusions than expected from 2D observations. The X-ray absorption of the inclusions shows that they are not solid inclusions. No bubbles were observed inside, indicating that we cannot determine whether they are really aqueous fluids or merely voids. One calcite grain has an inclusion approx. 2 microns in size, which seems to have a bubble and a tiny solid daughter crystal inside (three-phase inclusion). As we know the exact 3D position of the inclusion, we will anlyze the inclusion by SIMS after freezing the sample as has been done for a halite sample [3]. The present technique is useful for finding small inclusions not only in carbonaceous chondrites but also for terrestrial materials.

Tsuchiyama, A.↗

CVB: the Constrained Vapor Bubble Capillary Experiment on the International Space Station MARANGONI FLOW REGION

The Constrained Vapor Bubble (CVB) is a wickless, grooved heat pipe and we report on a full- scale fluids experiment flown on the International Space Station (ISS). The CVB system consists of a relatively simple setup a quartz cuvette with sharp corners partially filled with either pentane or an ideal mixture of pentane and isohexane as the working fluids. Along with temperature and pressure measurements, the two-dimensional thickness profile of the menisci formed at the corners of the quartz cuvette was determined using the Light Microscopy Module (LMM). Even with the large, millimeter dimensions of the CVB, interfacial forces dominate in these exceedingly small Bond Number systems. The experiments were carried out at various power inputs. Although conceptually simple, the transport processes were found to be very complex with many different regions. At the heated end of the CVB, due to a high temperature gradient, we observed Marangoni flow at some power inputs. This region from the heated end to the central drop region is defined as a Marangoni dominated region. We present a simple analysis based on interfacial phenomena using only measurements from the ISS experiments that lead to a predictive equation for the thickness of the film near the heated end of the CVB. The average pressure gradient for flow in the film is assumed due to the measured capillary pressure at the two ends of the liquid film and that the pressure stress gradient due to cohesion self adjusts to a constant value over a distance L. The boundary conditions are the no slip condition at the wall interface and an interfacial shear stress at the liquid- vapor interface due to the Marangoni stress, which is due to the high temperature gradient. Although the heated end is extremely complex, since it includes three- dimensional variations in radiation, conduction, evaporation, condensation, fluid flow and interfacial forces, we find that using the above simplifying assumptions, a simple successful model can be developed.

heat pipes↗

3D Multifunctional Ablative Thermal Protection System

NASA is developing the Orion spacecraft to carry astronauts farther into the solar system than ever before, with human exploration of Mars as its ultimate goal. One of the technologies required to enable this advanced, Apollo-shaped capsule is a 3-dimensional quartz fiber composite for the vehicle's compression pad. During its mission, the compression pad serves first as a structural component and later as an ablative heat shield, partially consumed on Earth re-entry. This presentation will summarize the development of a new 3D quartz cyanate ester composite material, 3-Dimensional Multifunctional Ablative Thermal Protection System (3D-MAT), designed to meet the mission requirements for the Orion compression pad. Manufacturing development, aerothermal (arc-jet) testing, structural performance, and the overall status of material development for the 2018 EM-1 flight test will be discussed.

Composite↗

Application of Scanning-Imaging X-Ray Microscopy to Fluid Inclusion Candidates in Carbonates of Carbonaceous Chondrites

In order to search for such fluid inclusions in carbonaceous chondrites, a nondestructive technique using x-ray micro-absorption tomography combined with FIB sampling was developed and applied to a carbonaceous chondrite. They found fluid inclusion candidates in calcite grains, which were formed by aqueous alteration. However, they could not determine whether they are really aqueous fluids or merely voids. Phase and absorption contrast images can be simultaneously obtained in 3D by using scanning-imaging x-ray microscopy (SIXM). In refractive index, n=1-sigma+i(beta), in the real part, 1-sigma is the refractive index with decrement, sigma, which is nearly proportional to the density, and the imaginary part, beta, is the extinction coefficient, which is related to the liner attenuation coefficient, mu. Many phases, including water and organic materials as well as minerals, can be identified by SIXM, and this technique has potential availability for Hayabusa-2 sample analysis too. In this study, we examined quantitative performance of d and m values and the spatial resolution in SIXM by using standard materials, and applied this technique to carbonaceous chondrite samples. We used POM ([CH2O]n), silicon, quartz, forsterite, corundum, magnetite and nickel as standard materials for examining the sigma and mu values. A fluid inclusion in terrestrial quartz and bi-valve shell (Atrina vexillum), which are composed of calcite and organic layers with different thickness, were also used for examining the spatial resolution. The Ivuna (CI) and Sutter's Mill (CM) meteorites were used as carbonaceous chondrite samples. Rod- or cube-shaped samples 20-30 micron in size were extracted by using FIB from cross-sectional surfaces of the standard materials or polished thin sections of the chondrites, which was previously observed with SEM. Then, the sample was attached to a thin W-needle and imaged by SIXM system at beamline BL47XU, SPring-8, Japan. The slice thickness was 109.3 nm and the pixel size was mostly 100 nm.

Tsuchiyama, Akira↗

Detrital Shocked Zircon Provides First Radiometric Age Constraint of <1472 Ma for the Santa Fe Impact Structure, New Mexico, USA

Impact structures are prone to erosion, burial and tectonic deformation. The Santa Fe impact structure in New Mexico contains shatter cones and shocked quartz, but is highly tectonized and eroded; estimates of the impact age (1200-300 Ma) and size (6-13 km) are poorly constrained. Here we report the first occurrence of shock-twinned zircon identified both in modern sediments and bedrock at the Santa Fe impact structure. Zircon {112} twin lamellae are considered diagnostic evidence of shock deformation and have been identified at several impact structures including Vredefort, Sudbury, Ries, Rock Elm, and in lunar impact breccia. A total of 6619 grains from fifteen sediment samples and two rock samples were surveyed; seven shocked grains were identified (7/6619 = 0.1%). One shocked zircon was identified in a biotite schist shatter cone. Five of seven shocked zircon grains were EBSD mapped; three were analyzed with multiple SIMS spots. EBSD mapping revealed {112} deformation twin lamellae in each of the five zircon grains. U-Pb geochronology for three of the shocked zircon grains yield crystallization ages from 1715+/-22 to 1472+/-35 Ma. LA-ICPMS U-Th-Pb analysis of detrital zircon grains from five samples yielded Paleoproterozoic (1800-1600 Ma) and Mesoproterozoic (1500-1300 Ma) ages. We reveal the first confirmed shocked zircon at the Santa Fe structure. Zircon is the third shocked mineral identified at this site, in addition to xenotime and quartz]; the {112} twin lamellae indicate that exposed bedrock may have experienced shock pressures up to ~20 GPa. The 1472+/-35 Ma age determined from a shock-twinned zircon is the first reliable maximum impact age constraint based on analysis of shocked material and extends the window for the Santa Fe impact event into the Mesoproterozoic.

Montalvo, Pedro E.↗

Analysis of Observed Contamination Through SAGE III's First Year on Orbit

SAGE III is a payload on the International Space Station that conducts measurements of ozone and other atmospheric constituents through the use of a moderate resolution spectrometer with an operating wavelength range of 290 nm to 1550 nm. Because of the optically sensitive nature of the payload, a suite of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) were included to monitor the operating environment. During the rst year of operation, the SAGE III TQCMs were instrumental in detecting several periods of higher contamination and localizing their sources. A clear window made from quartz crystal covers the instrument assembly's aperture. Under nominal operating conditions, this window is only open during science gathering activities. However, if the rates of contamination accumulation are detected to be above the background rate, the window will be kept closed during science gathering to protect the optically sensitive instrument mirror. An analysis of the signal transmissions through the window for the wavelengths of 290 nm to 1550 nm has been conducted to determine any possible degradation of the window and potential in uence on science data collected to date, and established a baseline for future analysis.

Thompson, Michael P.↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz (10¯11) crystal.

M. J. MacDonald↗

Empirical Constraints on Progressive Shock Metamorphism of Magnetite from the Siljan Impact Structure, Sweden

Little is known about the microstructural behavior of magnetite during hypervelocity impact events, even though it is a widespread accessory mineral and important magnetic carrier in terrestrial and extraterrestrial rocks. We report systematic electron backscatter diffraction crystallographic analysis of shock features in magnetite, from a transect across the 52-km diameter ~380 Ma Siljan impact structure in Sweden. Magnetite grains in granitoid samples contain brittle fracturing, crystal-plasticity, and lamellar twins. Deformation twins along {111} with shear direction of <112> are consistent with spinel-law twins. Inferred bulk shock pressures for investigated samples, as constrained by planar deformation features (PDFs) in quartz and shock twins in zircon, range from 0–20 GPa; onset of shock-induced twinning in magnetite is observed at >5 GPa. These results highlight the utility of magnetite to record shock deformation in rocks that experience shock pressures >5 GPa, which may be useful in quartz-poor samples. Despite significant hydrothermal alteration, and variable transformation of host magnetite to hematite, shock effects are preserved, demonstrating that magnetite is a reliable mineral for preserving shock deformation over geologic time.

magnetite↗

Magma-Sediment Interaction Induced Alteration Mineralogy on Mars: Detectability and Analytical Method Comparison Using the Curtis Sandstone as A Terrestrial Analog

Basaltic magmatism is a ubiquitous feature of the Martian crust, and would have interacted with sediments and fluids through the geologic history of Mars to potentially produce higher temperature hydrothermal systems , and contact metamorphic rocks. On Earth, comparable hydrothermal systems represent habitable environments, which can be used as an analog for Mars. Nevertheless, evidence of aforementioned hydrothermal systems on Mars has remained elusive, despite the efforts of both orbital and in-situ analyses. Limited low grade metamorphic minerals typically indicative of hydrothermal systems (prehnite, zeolites, serpentine) have been detected in the Martian crust, though the detections are typically isolated occurrences, and do not necessarily indicate an in-place metamorphic sequence. It is possible that orbital spectroscopy alone is not capable of detecting such an alteration front, with higher resolution in-situ analyses being required to detect the changes in mineralogy and species of alteration minerals associated with magma-sediment interaction. To constrain this, we have investigated a terrestrial analog on the Colorado Plateau, USA, where a mafic dike intrudes a quartz areinite of the Jurassic Curtis Sandstone. The investigation was carried out using Mars relevant instruments: Visible to Near-Infrared (VNIR) spectroscopy analogous to orbital spectroscopy, and X-ray Diffraction (XRD) analogous to CheMin on Mars Sample Laboratory Curiosity. While quartz sandstones have not been, and are unlikely to be, detected on Mars, the relatively mineralogically uniform Curtis Sandstone serves as analog here as it avoids complications of multiple mineral systems or significant element exchange with the surrounding area.

J R Crandall↗

Microstructural Evolution of the Civet Cat Norite (72255)

The ‘Civet Cat Norite’ is a ~ 2.5 cm clast within the Apollo impact melt breccia sample 72255 collected during Apollo 17 EVA 2 at Boulder 1. The norite is primarily composed of plagioclase and orthopyroxene with fine-scale exsolution lamellae of augite. The plagioclase and orthopyroxene (OPX) coexist with minor quartz and augitic clinopyroxene (CPX), and accessory apatite, baddeleyite, chromite, ilmenite, loveringite, merrillite, rutile and zircon. The major minerals range from 1 to 4 mm in size and show a cataclastic texture indicated by banding of the light and dark phases]. The chemical composition of the orthopyroxene, augitic exsolution lamellae, and exsolved oxides suggest the norite crystallized in the lower crust of the Moon (10 – 70 km depth) and was subsequently excavated by impact(s). Shock pressure estimates for the norite range from 15 – 35 GPa based on maskeleynite formation within the plagioclase, kink banding in pyroxenes, and granular recrystallization in the accessory phosphates. Previous Rb-Sr and 40 Ar/ 39 Ar analyses recalculated with modern decay constants yield relatively young ages of 4.16 ± 0.05 Ga and 3.99 ± 0.03 Ga, respectively. However, recent U-Pb analyses of some zircon grains from within the Civet Cat yield an age of 4.45 ± 0.03 Ga. While this is the oldest age for any rock recovered from the Moon, the full age spread of zircon from the Civet Cat range from ca. 4.46 to 4.02 Ga, indicating variable Pb-loss and complicating interpretation of the primary age. Recent atom probe analyses indicate minimal Pb mobilization within the oldest zircon grain from Civet Cat, supporting the interpretation that these ancient zircon ages reflect the age of the norite, rather than an apparent antiquity caused by reverse discordance. To investigate the potential antiquity and deep crustal origin of the Civet Cat norite, we have undertaken high resolution microstructural analyses of the major, minor, and accessory minerals to characterize the primary igneous textures and secondary overprinting by impact and metamorphism. The employed analytical techniques include scanning electron microscope-based electron backscatter diffraction (EBSD) analyses, electron probe microanalyzer (EPMA) chemical analyses, and transmission electron microscopy (TEM) of pyroxene, plagioclase, quartz, zircon, and phosphates.

T M Erickson↗

Melt Inclusions in Zircon: A Window to Understanding the Structure and Evolution of the Magmatic System Beneath the Laguna del Maule Volcanic Field

Explosive silicic eruptions pose a significant threat to society, yet the development and destabilization of the underlying silicic magmatic systems are still controversial. Zircons provide simultaneous information on the trace element composition and age of silicic magmatic systems, while melt inclusions in quartz and plagioclase yield important constraints on their volatile content as well as storage depth. Melt inclusions in zircons (MIZs) combine these data from a single mineral grain, recording the age, storage depth, temperature, and composition of magmas, and thus provide unique constraints on the structure and evolution of silicic magmatic systems. We studied MIZs from the Laguna del Maule (LdM) volcanic field in the southern Andes that is among the most active Pleistocene-Holocene rhyolitic volcanic centers worldwide and a potentially hazardous system displaying inflation rates in excess of 25 cm/yr. The host zircon ages suggest that the LdM MIZ record extends to ~30 kyr before eruption, in contrast to the melt inclusions in LdM plagioclase and quartz crystals that formed only decades to centuries before eruption. The major element compositions of MIZs are minimally affected by post-entrapment crystallization, and agree well with the LdM rhyolitic whole rock data. The more evolved major element composition of rle MIZs than rdm MIZs, suggests a long-term deeper connection of the rdm crystal mush to a more primitive magma body than that of the rle. The evidence of slow H diffusion observed in MIZs suggest that their H 2 O contents are not significantly affected by diffusion of H through the host zircon. The storage depths of 1.1 to 2.8 kbars recorded by the H 2 O contents of rdm and rle MIZs are consistent with the optimal emplacement window (2.0 ± 0.5 kbar) of silicic magma reservoir growth, storage, and eruptibility based on thermomechanical modeling (Huber et al. 2019).

Kei Shimizu↗

97e Intermediate Temperature Catalytic Reforming of Bio-Oil for Distributed Hydrogen Production

With the world's energy demands rapidly increasing, it is necessary to look to sources other than fossil fuels, preferably those that minimize greenhouse emissions. One such renewable source of energy is biomass, which has the added advantage of being a near-term source of hydrogen. While there are several potential routes to produce hydrogen from biomass thermally, given the near-term technical barriers to hydrogen storage and delivery, distributed technologies such that hydrogen is produced at or near the point of use are attractive. One such route is to first produce bio-oil via fast pyrolysis of biomass close to its source to create a higher energy-density product, then ship this bio-oil to its point of use where it can be reformed to hydrogen and carbon dioxide. This route is especially well suited for smaller-scale reforming plants located at hydrogen distribution sites such as filling stations. There is also the potential for automated operation of the conversion system. A system has been developed for volatilizing bio-oil with manageable carbon deposits using ultrasonic atomization and by modifying bio-oil properties, such as viscosity, by blending or reacting bio-oil with methanol. Non-catalytic partial oxidation of bio-oil is then used to achieve significant conversion to CO with minimal aromatic hydrocarbon formation by keeping the temperature at 650 C or less and oxygen levels low. The non-catalytic reactions occur primarily in the gas phase. However, some nonvolatile components of bio-oil present as aerosols may react heterogeneously. The product gas is passed over a packed bed of precious metal catalyst where further reforming as well as water gas shift reactions are accomplished completing the conversion to hydrogen. The approach described above requires significantly lower catalyst loadings than conventional catalytic steam reforming due to the significant conversion in the non-catalytic step. The goal is to reform and selectively oxidize the bio-oil and catalyze the water gas shift reaction without catalyzing methanation or oxidation of CO and H{sub 2}, thus attaining equilibrium levels of H{sub 2}, CO, H{sub 2}O, and CO{sub 2} at the exit of the catalyst bed. Experimental Bio-oil (mixed with varied amounts of methanol to reduce the viscosity and homogenize the bio-oil) or selected bio-oil components are introduced at a measured flow rate through the top of a vertical quartz reactor which is heated using a five zone furnace. The ultrasonic nozzle used to feed the reactants allows the bio-oil to flow down the center of the reactor at a low, steady flow rate. Additionally, the fine mist created by the nozzle allows for intimate mixing with oxygen and efficient heat transfer, providing optimal conditions to achieve high conversion at relatively low temperatures in the non-catalytic step thus reducing the required catalyst loading. Generation of the fine mist is especially important for providing good contact between non-volatile bio-oil components and oxygen. Oxygen and helium are also delivered at the top of the reactor via mass flow meters with the amount of oxygen being varied to maximize the yields of H{sub 2} and CO and the amount of helium being adjusted such that the gas phase residence time in the hot zone is {approx}0.3 and {approx}0.45 s for bio-oil and methanol experiments, respectively. A catalyst bed can be located at the bottom of the reactor tube. To date, catalyst screening experiments have used Engelhard noble metal catalysts. The catalysts used for these experiments were 0.5 % rhodium, ruthenium, platinum, and palladium (all supported on alumina). Experiments were performed using pure alumina as well. Both the catalyst type and the effect of oxygen and steam on the residual hydrocarbons and accumulated carbon containing particulates were investigated. The residence time before the catalyst is varied to determine the importance of the non-catalytic step and its potential effect on the required catalyst loading. Non-catalytic experiments (primarily homogeneous cracking) use a bed of quartz placed to capture any deposits that are formed in the volatilization and cracking zones. The inner reactor effluent is quenched by a flow of 10 SLPM He which serves to sweep the products quickly ({approx}0.03 s) to a triple quadrupole molecular beam mass spectrometer (MBMS) for analysis. The MBMS serves as a universal detector and allows for real time data collection. The study of pyrolysis by MBMS has been described previously. The dilution of the reactor effluent reduces the potential problems caused by matrix effects associated with the MBMS analysis. Argon is used as an internal standard in the quantitative analysis of all the major products (CO, CO{sub 2}, H{sub 2}, H{sub 2}O, and benzene) as well as any residual carbon, which is determined by subsequent oxidation of carbon (monitored as CO{sub 2}) after shutting off the feed and maintaining the oxygen/helium flow.

08 HYDROGEN↗

TEMPERATURE MONITORING OPTIONS AVAILABLE AT THE IDAHO NATIONAL LABORATORY ADVANCED TEST REACTOR

As part of the Advanced Test Reactor National Scientific User Facility (ATR NSUF) program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced sensors for irradiation testing. To meet recent customer requests, an array of temperature monitoring options is now available to ATR users. The method selected is determined by test requirements and budget. Melt wires are the simplest and least expensive option for monitoring temperature. INL has recently verified the melting temperature of a collection of materials with melt temperatures ranging from 100 to 1000 C with a differential scanning calorimeter installed at INL’s High Temperature Test Laboratory (HTTL). INL encapsulates these melt wires in quartz or metal tubes. In the case of quartz tubes, multiple wires can be encapsulated in a single 1.6 mm diameter tube. The second option available to ATR users is a silicon carbide temperature monitor. The benefit of this option is that a single small monitor (typically 1 mm x 1 mm x 10 mm or 1 mm diameter x 10 mm length) can be used to detect peak irradiation temperatures ranging from 200 to 800 C. Equipment has been installed at INL’s HTTL to complete post-irradiation resistivity measurements on SiC monitors, a technique that has been found to yield the most accurate temperatures from these monitors. For instrumented tests, thermocouples may be used. In addition to Type-K and Type-N thermocouples, a High Temperature Irradiation Resistant ThermoCouple (HTIR-TC) was developed at the HTTL that contains commercially-available doped molybdenum paired with a niobium alloy thermoelements. Long duration high temperature tests, in furnaces and in the ATR and other MTRs, demonstrate that the HTIR-TC is accurate up to 1800 C and insensitive to thermal neutron interactions. Thus, degradation observed at temperatures above 1100 C with Type K and N thermocouples and decalibration due to transmutation with tungsten-rhenium and platinum rhodium thermocouples can be avoided. INL is also developing an Ultrasonic Thermometry (UT) capability. In addition to small size, UT’s offer several potential advantages over other temperature sensors. Measurements may be made near the melting point of the sensor material, potentially allowing monitoring of temperatures up to 3000 C. In addition, because no electrical insulation is required, shunting effects are avoided. Most attractive, however, is the ability to introduce acoustic discontinuities to the sensor, as this enables temperature measurements at several points along the sensor length. As discussed in this paper, the suite of temperature monitors offered by INL is not only available to ATR users, but also to users at other MTRs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for characterization of a spherically bent crystal for K.alpha. X-ray imaging of laser plasmas using a focusing monochromator geometry

A method is provided for characterizing spectrometric properties (e.g., peak reflectivity, reflection curve width, and Bragg angle offset) of the K.alpha. emission line reflected narrowly off angle of the direct reflection of a bent crystal and in particular of a spherically bent quartz 200 crystal by analyzing the off-angle x-ray emission from a stronger emission line reflected at angles far from normal incidence. The bent quartz crystal can therefore accurately image argon K.alpha. x-rays at near-normal incidence (Bragg angle of approximately 81 degrees). The method is useful for in-situ calibration of instruments employing the crystal as a grating by first operating the crystal as a high throughput focusing monochromator on the Rowland circle at angles far from normal incidence (Bragg angle approximately 68 degrees) to make a reflection curve with the He-like x-rays such as the He-.alpha. emission line observed from a laser-excited plasma.

36 MATERIALS SCIENCE↗

The Effect of Foaming and Silica Dissolution on Melter Feed Rheology during Conversion to Glass

As the nuclear waste glass melter feed is converted to molten glass, the feed eventually becomes a continuous glass-forming melt in which dissolving refractory constituents are suspended together with numerous gas bubbles. Knowledge of mechanical properties of the melter feed is crucial for understanding the feed-to-glass conversion as it occurs in the cold cap. We measured the viscosity during heating of the feed and correlated it with the independently determined volume fractions of dissolving quartz particles and the gas phase. The measurement was performed with a rotating spindle rheometer on the melter feed heated at 5 K/min starting at several different temperatures. The effect of quartz particles, gas bubbles, and compositional inhomogeneity on the glass-forming melt viscosity was determined by fitting a linear relationship between log viscosity and volume fractions of suspended phases to data.

Effect of solids and gases on viscosity↗